Document wgkjZEGB3JQrZEYRbDor0oJgJ

568, CHAPTER 31 1948 Guide parts of the room, or they may. be cast into panels to imitate oak or other wood designs. With flat, plate panels it is common practice to use a frame of plaster, wood, metal or composition to allow for expansion. These plates may be heated, with either hot water or steam and connected as in an ordinary radiator system. See Figs. 5 and 6. 5. By electric healed metal plates or panels. These plates or panels are either placed in insulated recesses of walls or ceilings or fastened to the construction, as found desirable. They should not have a surface temperature much above 200 F. Some have a much higher surface temperature but a lower temperature gives a more comfortable condition andjs more efficient. 6. By electrically heated tapestry mounted on screens and on the wall. For this purpose the screen is woven with an electric continuous conductor. Such screens are useful to plug in at any position for emergency local heating without taking care of a large room or office. Pdnel'iHeating and Radiant Beating 569. heating systems should, in general, be operated continuously since the panels have large thermal capacities. Where panels are heated by high ' temperature radiation from a heat source directed toward them, this qualification- does not apply. 1. Assume the location and the approximate size of.the healing- panel. Heating panels may be located in ceilings or floors or walls. .Ceiling panels have the advantage that their heat emission is not affected by tapestry or furniture and that they' can be used', to a limited extent, as cooling panels during the summer months. 'If usedin low rooms, however, they may produce an undesirable heating effect upon the'head. Floor panels have the advantage that they can be easily installed and that much of the radiated heat is delivered to the lower portions of the.walls; they have the disadvantage that their heat emission is rather uncertain, since it may be affected by rugs, carpets, furniture, machinery, etc. It is best to make the panels as large as practicable; for example, if the floor or ceiling is used as the heating panel, it is best to use the entire floor or the entire ceiling, or both. Heating a room by means of panels, is very similar to lighting a room. Heat radiation is exactly like light radiation, except that it has a longer wave length. If a room is lighted Fig. 5. Pillar Type Radiant Heat Panel ; Note. .If all of.a heating panel is installed at one end of a large room there may be a marked difference between the equivalent temperature on the two side's of the body. , It is usually desirable, therefore, that the heat be distributed at different parts of the walls and ceilings so that no uncomfortable effect will be felt from unequal heating. CALCULATION PRINCIPLES Part I--Panel Heating The term panel heating, involving both radiation and convection, is applied in this chapter to a system in which the heat is transmitted from panel surfaces to both air and surrounding surfaces, as is the case under indoor conditions. Panel heating systems for buildings may be designed as illustrated and described in the following design of a panel heating system for the room shown in. Fig.. 7. The design is based on continuous heating.. Panel by means of a large number.of.small units distributed uniformly over the ceiling, the room is lighted more uniformly than if it is lighted by means of a single unit of equal, capacity. Similarly, if the entire ceiling is the heating panel, the room is heated more "uniformly than if only a fractional part of the ceiling is used as the heating panel. In the following example, the entire ceiling will be used as the heating panel. 2. Select the desired mean temperature of the dir in the room. In a panel-heated room, the mean air temperature is a few degrees lower than the mean temperature of the surfaces of the enclosing walls, floor, and ceiling. In a room heated by introduction of warm air or by means of radiators, convectors, or other similar heating appliances, located within the room, the mean temperature of the air is a few degrees higher than the mean temperature of the surfaces of the enclosing walls, floor, and ceiling. Under, ordinary conditions, in a panel-heated room, the mean tem perature of the air ranges from approximately 65 F to 72 F. In the .following example, 68 F is selected as the mean air temperature. '3. Determine as accurately as practicable, the mean temperature of the inside surfaces of the enclosing walls, floor, and ceiling. The two inside walls are assumed to separate rooms, which are filled with 68 F air,, so that both surfaces of each wall are in close contact with 68 F air. The surface tem-