Document wgkB65dNqrMydQyXwzpLgG8kB
Detection of Folyehlorlnated Biphenyls (FCB'c) In Adipose Tissue
The acetonitrile partition, described in the attached method, requires a minor modification to insure a quantitative recovery of tho PCB's.
At tho end of' the acetonitrile partition, the petroleum ether extract should be concentrated to 25 ml and transferred to the florisil column after the column has teen washed with 150 ml of petroleum ether. (Discard wash as soon as the petroleum ether extract is placed on the column).
If multiple unknown peaks are present on the final chromatogram,
PCB's may bo present.
HONS 075836
CSiantitation of Polychlorinated Biphenyls (PCB's) in Adipose Tissue
The attached chromatograms indicate the method which should be
used for quantitation. As shown, 12 peaks from sample 1 were matched
(same retention time) with 12 peaks from the PCB 1242 standard, and
the peals height of each one was meosured.
.
The sum of the heights of the identifiable peaks from the sample
was divided by the sum of the heights of the corresponding peaks from
tho 5 nanogram standard. Since the injection represented 1 mg. of
sample, the concentration of PCB 1242 was 1-9 ppm in this sample.
You may or may not be able to match as many peaks as are shown
on the attached chromatograms. For proper quantitation, however, you
should use as many peaks as can be properly matched.
HONS 0 7583 7
07583a