Document wgjEN1eMLKLEmnmKgE8gYr7VQ

284. CHAPTER 12' 1952 Guide 14. U-Table Summer Coefficients of Heat. Transmission of Flat Roofs Covered With Built-Up Roofing* > ~-Btu-per (hour) (square foot) (F deg difference between the air on the two sides) '` 1 ~-----ft's-----------------------------------------------------------------Insulation on Top op Deck {Covered With Built-Up Roofing) TtpE'.oF; Roof Deck Ceiling not shown Thickness of Roof Deck (Inches) . NoCeiling-- , . Underside of Roof Exposed Furred Ceiling with Air Space, Metal Lath and Plaster A No' In sula' tion Insulating' Board? Thickness, In. i 1' u 2 No In-, sula- tion Insulating Boardd .Thickness, In. i u 2' Flat Metal -Roof Deck -4 Ply Felt : Roof Ditto " + } in. 81ag. 0.73 0.35 0.23 0.17 0:13 0.40 0.25 0.18 0.14 0.12 0.54 0.30 0.20 0.16 0.13 0.34 0.22 0.16 0.13 0.11 Precast Cement Tile ----- 4 Ply Felt Roof it Ditto .4* in. Slag H ' .1 .0.67 0.33 0.22 0.17 0.13 0.38 0.24 0.18 0.14 0.12 0.50 0.28 0.20 0.15 0.12 0.32 0.21 0.17 0.13 0.11 Concrete ' - f5>w. LfC' ~7 --J 4 Ply Felt Roof . 2 0.65 0.33 0.22 0.16 0.13 0.37 0.24 0.18 0.14 0.12 4 0.59 0.31 0.21 0.16 0.13 0.36 0.23 0.17 0.13 0.12 6 0.54 0.30 0.20 0.16 0.13 0.33 0.22 0.17 0.13 0.11 Ditto - 2 .. . 0.49 0.28 0.20 0.15 .0.12 0.31 0.21 0.16 0.13 0.11 4... 0.46 0.27 0.19 0.15 0.12 0.30 0.21 0.16 0.13 0.11 + 4 in. Slkg 6 0.42 0.26 0.19 0.14 0.12 0:29 0.20 0.16 0.13 0.10 Gypsum and Wood Fiberb on 1* Gypsum Board ---------- N---------^ e---^ 4 Ply Felt Roof Ditto + i m. Slag. 24' 31 24 31 0.34 0.23 0.17 6.13 0.12 6.25 0.18 0.14 0.12 0.097 0.28- 0.20 0.15 0.12 0.11 0.21 0.16 0.13 0.11 0.094 0.29 0.20 ,0.16 0.13 0.11 0.22 0.16 0.13 0.11 0.093 0.25 0.18 0.14 0.12 0.10 0.19 0.15 0.13 0.10 0.090 Wood _L\---- __ _ 4 Ply Felt Roof ! 0.43 u 0.33 2 -0:29 3 0.22 1 -. Ditto H 4* 4 in. Slag 2 3 0.35 0.29 0.26 0.20 0.26 6.19 0.15 0.12 0.'29 0.22 0.17 0.13 0.11 0.24 0.20 0,16 0.13 0.11 0.22 0.16 0.13 .0.11 0.09 0.17 0^23 0.17 0.14 0.11 0.25 0.20 0.15 0.12 0.10 0.21 0.19 0.14 0.12 0.10 0.20 0.15 0.12 0.10 0.09 -0.16 0.^0 6:15 0.13 0:11 0.18 0.14 0.12 0.097 0,16 .0.13 0.11 0.094 0.13 0.12 0.10 0.085 0.18 0.14 0.12 0.10 0.17 0.13 0.11 0.093 0.15 0.13 0.10 0.090 0.13 0.11 0.09 0.081 The summer coefficients are considered temporary, and have been calculated 'with an outdoor wind velocity of 8 mph. For summer an inside surface conductance of 1.2 ha* been used instead of the regular 1.65 value. In all of these roofs a 4 ply felt roof has been assumed I in. thick, thermal conductivity = 1.33. Fitch and slag have been assumed as an additional thickness of 1 in. which has been assigned thermal con ductivity = 1.0. In both cases thermal conductivity refers to one.inch thickness. . b 87i percent gypsum, 124 percent wood fiber. Thickness indicated includes 4 in. gypsum board. This is a poured roof. c Nominal thickness of wood is specified, but actual thickness was used in calculations.' d If corkboard insulation is used, the coefficient U may be decreased 10 percent. sky which is not included in the Mackey and Wright method. The tem perature differentials for roofs were based on an inside surface conductance of 1.65 because the charts prepared by Mackey and .Wright1* used this Cooling Load '285 value, and it was not considered practicable to repeat their work .using a different film coefficient. An examination of the values given in their paper indicates, that the temperature differential would be changed very little even if a value 1.20 were used instead of 1.65. But to obtain the heat flovy .rates through roofs, more accurate values will be obtained if the overall heat, trans mission coefficient is calculated using 1.2 as the inside film conductance of s heat transfer in summer. The roof coefficients of transmission for summer shown in Table 14 are based bn surface conductances /cro of 4.0 for an outside roof surface and 1.20 for ah inside ceiling surface.' The outside conductance 4.0 is used for . summer because it corresponds to a wind velocity of approximately 7.5 mph averaged for rough and smooth surfaces, and is more representative of summer wind velocities. Also, the lower wind velocity should be used in order to be on the safe side in determining the sol-air temperature. The inside conductance 1.20 is used because the convective portion of the film conductance factor, of downward heat flow from a. horizontal`surface is appreciably less than the winter conductance, which-applies when heat is flowing upward. ' ' j\ .. . ; Since there is little difference in wall transmission coefficients for summer, based on the conductances of 4.0 and 1.65, and the winter coefficients, based on 6.0 and T:65,-it is recommended that the overall coefficient Ujfor walls, be taken directly from the tables in Chaptei! 9iirwhich they are based on an outside film conductance of 6.0, corresponding to a 15 mph wind velocity. Advantages of Equivalent Temperature Differential Method The advantages' of the equivalent temperature differential* method of determining the total heat transmission are given in following paragraphs, and areapparent from Examples lO to 12. : 1. The total sensible heat flow is obtained by multiplying the overall heat trans mission coefficient, U, and the equivalent temperature .differential indicated in Tables 12 and 13. . 2. The temperature differentials listed for few representative types of con struction maybe used on all classes of walls and roofs, even though the overall heat transmission coefficient is-different, provided the structure has thermal and.physical properties similar to one of those listed in Tables 12 and 13. 3; Adjustments can be- made, according to instructions given in the footnotes, _ for room and outdoor conditions different from those on which the tables are based. * Examples of Use of Equivalent Temperature Tables Example 10: Given: A roof is constructed of 6 in. of stone concrete with 2 in. of insulating board and tar felt roofing jf in. thick, and is exposed to the sun. The loca tion is the central part of the United States. Find the rate of heat flow into building at 2:00 p.m. during July for an outdoor design temperature 95 F, and an inside tem perature 80 F. Solution: From .Table-12 in 2 p.m. column for 6 in. concrete plus 2 in. insulation, find the total equivalent temperature differential 34 deg. The overall heat trans mission coefficient for summer is taken from,Table 14 and is found to be 0.13. The heat flow rate equals 34 X 0.13 = 4.42 Btu per (hr) (sq ft). Example 11: For the conditions of ExampldiO, find;the rate of heat flow into build ing at 2:00 p.m. during July for design temperatures of 105 F (outdoor) and 78 F (in door). Daily range of temperature 30 deg, i.e., outdoor temperature minimum .of 75 F which,occurs.at 4;00;or 5:00 a.m.; this.being 30 deg less than the maximum. ; -7 Solution.:. Make.correction in equivalent. temperature differential in accordance ` with Note 5 in Table 12 as follows: ' .. The correction' for 27 deg design temperature difference is (27 -- 15) = + 12.