Document wgQ2Xdba4ZnrQ9DLNJbZYX1oD

Vista Chemical Company 15990 N. Barker's Landing Rd. Post Office Box 19029 Houston,Texas 77224 Phone (713) 531-3200 ^ Q Co rAWr June 26, 1986 Mr, Steve Smith State of California Division of Occupational Safety and Health Administration 1625 Shattuck Avenue, Room 302 Berkeley, CA 94709 VISTA I Dear Mr. Smith: Enclosed are Material Safety Data Sheets for the Vista products. Light Aromatic Concentrate and Heavy Ends EDC/VCM, as you have requested. Please call me at 713-531-3445 if you have further questions regarding this matter. Sincerely, ThomasG. Grumbles, C.I.H. Environmental Quality Manager ajo/9 ! VVV 000015261 TO: Safety Directors Jte.A'L FROM: DATE: Interoffice Communication $UBJ: T. G. Grumbles June 26, 1986 PLANT NOISE SURVEYS - HOUSTON ASSISTANCE The Houston office can provide the plant services necessary to satisfy the noise survey needs of the plants. Specifically, we can provide the survey design for dosimetry and noise conturing, and in most cases provide the manpower to accomplish the surveys. I am currently attempting to obtain approval for capital funds to purchase dosimeters. I need to determine survey needs for the next year and the equipment the plants currently have. Please provide me with the following by July 18. 1. Anticipated Survey Needs: A. Dosimetry - process units, etc. B. Conturing - updating areas with changed processes, modified equipment, or full contour, etc. C. Current equipment - dosimeter and sound level meter type and number you now have. Please call me if you have questions on the above. Thomas G. Grumbles ajo/9 cc Plant Managers VVV 00G015262 To: Tom Grumbles, 206 Environmental, Timberway Interoffice Communication From: Date: Subject: K. L. Fogg, LCLAB Plant, Westlake February 25, 1986 NOISE SURVEYS - NOISE DOSIMETRY VISTA I have discussed the problem of noise surveys and noise dosimetry s with the Safety Directors of the Vista Chemical Plants. As you know, those services were provided by Conoco before the separation of Conoco and Vista Chemical Company. The Safety Directors agreed that a continuing need for this service exists and will continue to exist. The general consensus is that the resources and equip ment are not available in the plants to satisfy that need. There was general agreement that each plant would support the concept of this service being provided by your organization. The alter native to this would be to have those services provided by a contract consultant which would result in significant expenditures. As we discussed, I would like you to pursue the possibility of your organization providing this service to the plants. v,: K. L. Fogg cc: R. D. Gamblin - Timberway J. Friend, A. Sather - Aberdeen T. Huffman, L. Mauerman - Baltimore J. Mayer, M. Tonkovich - Hammond R. T. Ferrell, J. A. DeBernardi, Sid Pitts - LCCP H. Garrison, R. Gantz - Oklahoma City PVC R. Conrad, Steve Ashby - LCVCM R. W. Seymour - LCLAB