INTERNAL CORRESPONDENCE
UNION CARBIDE CORPORATION TECHNICAL CENTER
P.O. BOX 8361, SOUTH CHARLESTON, WV 25303
To[N8TMH. E. Rucker o,v,s,on 512/2009
Location Area
Copv" B> H> Avashia> m.D. _ 512/23 J. W. Barna - 2009/6 W. L. Browning - 2009 R. E. Coyner - 2009 C. P. Maxwell - 701/2 B. R. McMakin - 2009
Dste June 12, 1987 rwnaongDepc. EM&TS - HS&EA
Area Subiect
Industrial Hygiene Asbestos Exposure Monitoring
'
\
Attached are the results of asbestos exposure monitoring for three days on insulators at the Institute Plant while removing asbestos on a 3-inch steam line and a 4-inch product line at the #1 dock area in an enclosure. The area enclosed was 5.5 x 6.5 x 200 feet or 7150 ft^. HEPA exhaust was 120,000 ft-3 per hour which is equivalent to 16 air changes per hour. The area enclosed was along the roadway and the dike wall between the #1 and #2 docks. The area was barricaded while enclosure was in place.
Seven out of eight personal exposure samples exceeded the 0.2 fiber/cc permissible exposure level standard and the eighth exceeded the 0.1 fiber/cc action level standard. We encourage you to use supplied air respirators as much as possible in the asbestos abatement procedures. Please communicate to your employees the need for the utmost care and precaution while removing asbestos.
Employees wore two pair of coveralls, headcovers, boots, gloves and A0 R57-A half-face HEPA cartridge respirators. No street clothes were worn. They showered before lunch and at the end of the workday before leaving plant.
UCC 011334
ASBESTOS EXPOSURE MONITORING
-2-
June 12, 1987
Please inform '
_.
,, . ___ ..
of their exposure monitoring results as soon as possible. Have them
sign and date this report and return to M. A. Patel at Building 701-330.
If you have any questions or if we can be of further assistance, please call us on extension 4779 or 3750.
WORK BY:
APPROVED BY:
VE$:HJK:MAP:rab 2384P
. fsi
Manhar Ai Patel
UCC 011335
Date 5-6-87 5-6-87 5-7-87 5-7-87 5-7-87 5-7-87 5-8-87
5-8-87
Sample Type/ Employee Name
e
\
ASBESTOS EXPOSURE MONITORING
Comp. Ref. W2216 W2217 W2218
Sample Time
7hr lmin 7hr Omin 7hr 4min 6hr 58min 6hr 58min 7hr lmin 6hr 46min
6hr 43min
Air Cone. Fibers/cc
0.495 0.547 0.402
0.496 0.231 0.280 0.157
0.503
twa8 Fibers/cc
0.433 0.478 0.355 0.432
0.201 0.246 0.132
0.422
COMMENTS
Stripped, bagged and vacuumed appx. 200 feet of 3 and 4-inch lines in enclosure at #1 Dock area.
Stripped, bagged and vacuumed appx. 200 feet of 3 and 4-inch lines in enclosure at #1 Dock a^ea.
Stripped, bagged and vacuumed appx. '120 feet of 3 and 4-inch lines in enclosure at l<#1 Dock area.
Stripped, bagged and vacuumed appx. 120 feet of 3 and 4-inch lines in enclosure at #1 Dock area.
Stripped, bagged and vacuumed appx. 120 feet of 3 and 4-inch lines in enclosure at #1 Dock area.
Stripped, bagged and vacuumed appx. 120 feet of 3 and 4-inch lines in enclosure at #1 Dock area.
Stripped, bagged and vacuumed approx. 80 feet of 3 and 4-inch lines in enclosure then cleaned lines at #1 Dock area.
Stripped, bagged and vacuumed approx. 80 feet of 3 and 4-inch lines in enclosure then cleaned lines at #1 Dock area.
UCC 011336
ASBESTOS EXPOSURE MONITORING (Continued)
Comp. Ref. W2216 W2217 W2218
Date 5-8-87
5-8-87
Sample Type/ Employee Name AREA
AREA
Sample Time
Air Cone.
TWAg
Fibers/cc Fibers/cc
COMMENTS
6 hr 32min 0.003
0.003
Inlet to HEPA Filtering system for enclosure at #1 Dock area<
6 hr 43min 0.009
0.007
Outlet' to HEPA Filtering .. exhaust for enclosure at #1
lOock area.