Monsanto Chemical Company Anniston Method No. 14-17-40 .'SUBJECT: 'loftenin-" Point of ''olid Aroclors METHOD: Ball and Ring
This method is a modification of theA.O.T.H, standard method of test for softening point of bituminous materials, seria^ designation: E 28-397, The method differs from the standard method in that the rings are larger than specified. A two ring support is also used in order that two tests may be made simultaneously.
Apparatus
The apparatus consists of the fo living: (a) Two tapered brass rinrs, 5/8" inside dia. at bottom, 11/16" inside diameter at top and 1/4" deep: thickness of wall 3/52", (b) Two steel balls, 3/8" diameter weighing 3.45 to 3.55 grams each, (c) A 800 ml. Griffin low form leaker, (d) A ring support for the two rings having a brass plate exactly -me inch be low the plate supporting the ring, (e) A 300*0. A.D.T.M. low distilla tion thermometer graduated 1C.
'
Preparation of the Sample
-
The sample shall be melted and stirred thoroughly, avoiding overheating
or incorporating air bubbles in the mass and then ooi.red into the rinr
so as to leave a slight excess on cooling. Since the Aroclors shrink
considerably on cooling, the rinr should be well filled, nearly to over
flowing. A little of the excess should be drawn over the top of the ring
at several points so as to prevent the cooled Aroclor from dropping out
of the ring. In the same ivay,, the second ring is filled with a standard
Aroclor of known softening point. The standard Aroclor should have a
softening within at least 10 to 15of the Aroclor being tested.
.
The rings, while being filled should rest on a clean can lid or on a brass plate which has been amalgamated to prevent the Aroclor from ad hering to it. The* Aroclor in the rin^s should be fully cooled and hardened before proceding with the test.
Procedure
Add cool solution (employ via ter for softening point between 0-80*C, glycerin for between 80-200*0., mineral oil for above 200*C.) to the beaker until the surface of the solution is 2" above the plate holding the rings when the ring support is suspended in the beaker. Place the ring3 containing the Aroclor to be tested and the standard Aroclor on the ring support. Place a ball on. the center of the upper surface of
the Aroclor in each ring. Suspend the' thermometer so that the bottom of the bulb is level \vith the bottom of the rings and just midway be
tween the two rings.
dS\N 330862
STLCOPCB4077506
Softening roint of Solid Aroc2.ar3 ~ 2 -
Place beaker and apparatus on a 6 inch round hot nlate and heat at such a rate that the temperature is raised 5*C. each minute,,
The temperature recorded by the thermometer at the instant the Aroclar touches the bottom piste is reported as the softening point,, The heat ing Is continued until both /croclors have dropped to the bottom 'late* No corrections are made for emergent stem.
Notes
.- -
lo The standard Aroclor is run along with the sample under test in order to compensate for variations in rate of heating, dilution of glycerin* and thermometer variations.
.2 The softening point of the standard sample is determined by making several determinations using fresh glycerin and carefully checking the rise in temperature of the glycerin so that it is as near as possible to 5*C. per minute.
3. The glycerin may be used repeatedly for the tests after removal of the Aroclor.
4. Benzol is used for cleaning the rings and balls.
5. hater can be used instead of glycerin for softening points up to 90*C.
6. For softening points above 100*C, well boiled glycerin should be used. The usual glycerin is not satisfactory above 125 to 130*0* it boils with loss of water while the temperature remains practi cally constant. It is well to have a supply of high-boiling glycerin on hand to be used only for softening points above 100C.
7. Air bubbles on the rings and balls during the test should be avoided aa far as possible.
8. The rate of rise of temperature of the glycerin shell be uniform for each minute after the first 3 minutes of heating and not averaged over the period of the test.