Document we2vzR4Mg9JR3VZz7dQz0BGD

iVlFR'S PRGC rile E26211 Voi. 1 Sec. Gen.. *Page 1 GENERAL Issued: 11-5-73 Revised: 8-4-86 PRODUCT COVERED: Underground Feeder and Branch Circuit Cable: Single and multiconductor, Type UF; multiconductor Type UF-B LISTING MARK COMPOSITION: One of the following Listing Marks shall be used depending on the conductor material employed. Insulated Copper or Copper-Clad Aluminum Conductors Insulated Aluminum Conductors LISTED UNDERGROUND FEEDER CABLE LISTED ALUMINUM UNDERGROUND FEEDER CABL. GENERAL CONSTRUCTION: Except as noted elsewhere in this Procedure under the heading "DESCRIPTION," the cable described in this Procedure is constructed in accordance with the requirements of the Standard for Thermoplastic Insulated Underground Feeder and Branch-Circuit Cables. 0028 SC-ELEC-05760 File E262I1 Vol. 1 Sec. Gen. Page 2 Issued: 11-5-73 Revised: 5-1-89 TEST EQUIPMENT PROVIDED BY MANUFACTURER: . As described in the Standard for Thermoplastic-Insulated Underground Feeder and Branch-Circuit Cables. TEST TO BE CONDUCTED BY MANUFACTURER: ' As described in the Standard for Thermoplastic-Insulated Underground Feeder and Branch-Circuit Cables. MARKING: The wires and cables described in this procedure shall be marked in accordance with the requirements of the Standard for Thermoplastic-Insulated Underground Feeder and Branch-Circuit Cables, except as modified elsewhere in this Procedure. ' Sunlight Resistant Cable - This manufacturer is authorized to mark on Types UF and UF-B cable, by means of surface or imprinting on the jacket, the legend "Sunlight Resistant" and a tag mark bearing the same legend if this manufacturer employs a PVC compound which appears on the latest issue of ^Underwriters Laboratories Inc., Bulletin, Subjects 83, 493, 854, 127? and 1569. If the individual conductors are of copper-clad aluminum, the size of the conductor wherever it appears (on tags, reels or the surface of the product), shall be followed by "AL (CU-CLAD)". . COMPOUND IDENTIFICATION BY MANUFACTURER: While in the process of manufacture, prior to the application of labels, the wires described in this Procedure shall be identified with a tag or shop order so that the Laboratories' representative can determine what compound has been used for insulation. Either a factory code available to the representative or the actual compound designation may be used. MANUFACTURER'S IDENTIFICATION: One of the following methods of identifying the manufacturer may be used: 1. One black and one white marker threads, or 2. -Manufacturer's name, trade name or "E26211" surface marked or indent printed. 0030