Document waNRO43w6BzQpmJJ5bgG3XxQ
Silo Scalcnts as a Source of Polychlorobiplicnyl (PCB) Coiilnniiiiatiou of Animal Feed byR. F.Sknentny,* R. W. Hcmken* and II. W. Dorouch*
Univenity of Kentucky, Lexington, Kentucky 40506
The physical and chemical properties of poly chlorinated biphenyls (PCB's) are ideal for use in a wide range of industrial and commercial materials such as plastics, polymer films, wafer-proofing compounds and putty, asphaltic materials, printing inks, waxes and synthetic adhesive (1,2). Because of the numerous applications of PCB's, they are widely distributed in the environment and have reportedly contaminated a number of wildlife species (3,4,5). It has been point ed out that residues of PCB's may Interfere with the detection and analysis of certain organochlorine pesticides (5). Recently, Armour and Burke (6) have successfully dealt with this problem and described a silicic acid column method for separating PCB's from DDT and its analogs. The extensive distribution of . PCD residues in the environment and their potential hazard havo stimulated increased interest in these compounds.
Polychlorinated biphenyls were used in the formulation of some paints and sealents which are used on silo walls. Since there is no level of PCD's con sidered safe in milk at the present time, it is important to have information on the potential contami nation of silage by contact with silo walls sealed with materials containing PCB's. Several dairy farmers in Kentucky were recently prevented from shipping milk because of significant levels of PCB residues in their milk. In addition, several other dairy farmers were notified that samples of their milk contained trace levels of PCD's and they would be prevented from shipping their milk if the levels were not maintained or reduced. One of the silos involved in the above mentioned actions had been coated 9 years earlier with a soalent containing PCD's*
\ *-
Our study was initiated to determine the level and
Department of' Entomology ^Department of Animal Sciences
\` \
bull'll* ot Entlronnirnul Ceniaminttloo I Tftilcalaif, V#l.t, N*. i, l*M, publlJifd bj Sprinfer-VcrU| New York Inc.
MONS
distribution of PCB contamination in corn silage from several silos thought to be coated with sealents con 't* taining PCB's. Samples of silo wall chips 4lso were ` examinod for PCB residues, and limited laboratory tests were conducted on the solubility of PCB's in water and in a water extract of silage.
Experimental
c... Materials. A sample of Aroclor 1254 for experi mentalise was obtained from the Kentucky Department of Health. A standard hexane solution of this material
was prepared for gas chromatographic analysis so that 1 microliter of solution contained 1 nanogram of Aroclor
1254 .
Apparatus. A Varian Aerograph series 1700 gas chromatograpTT'equipped with an electron capture detec tor and a glass column, 10* x 1/8", containing 4% SE 30 and 61 OP 1 (lfl mixture) on Anakron ABS 80/90 mesh was used for these studies. Operating conditions were as
follows: nitrogen 35 ml/minute, column temperature,
i 195*C; injector temperature, 200*C; detector tempera ' ture, 200C* standing current, 1.28 x 10" AMPS. The i ' recorder speed was 10 inches per hour.
t Extraction and Cleanup of Samples. A 25-g
sample of corn silage was^homogenTzed for 3 minutes *
V
with 300 ml of a hexane-isopropyl alcohol (8:1) mixture, , The homogenate was filtered and the filtrate transferr
ed to a separatory funnel. The alcohol was'removed
from this mixture by washing with 300 ml of a 2% NnCl
solution. The corn silage sample was homogenized a
second time with 150 ml of benzene, filtered and the
, benzene was added to the hexane., This mixture waa
concentrated to approximately 2 ml and added to a
florisil column (2). The column, 22 mm I.D., was
packed with 25 g of activated florisil, with approxi
mately one inch of anhydrous sodium sulfate added to
the column. The PCB's were eluted with 200 ml of
.
hexane. The hexane was concentrated to 10 ml for gas
chromatographic analysis. It was established that DDT
and its analogs were not present in sufficient quanti
ties to interfere with the quantitation of the PCB's.
Therefore, separation of the 2 groups of materials on
1 a silicic acid column was not necessary.
v The extraction and cleanup of the silo wall chips were similar to that employed for silage except that a
5-g sample of silo wall chips was ground in a mortar with 25 ml of the Isopropyl alcohol-hexane mixture and
then a second time with 25 ml of benzene. The column cleanup was the Bame as above.
i.if i W: i
MO NS 0833 72
Collection of Samples. Silage samples were removed"from"the top of silos that ranged from 12 to 16
feet in diameter. At certain distances from the silo
wall, towards the center, a silage sample was collected. ,A sample representing each distance from the wall con
sisted of a composite of silage from 6 sampling site9. Small chips from each silo wall were taken from 6 points of the exposed wall. All samples were kept frozen until analyzed.
SoIubillty Experlmenta. An attempt was made to
determine the amount of PClPs that would dissolve in water or in a water extract of silage. For this purpose 5 g of the silo wall chips obtained from farm C were placed in flasks with 45 ml of water or with 45 ml of a water extract of silage in the other. The silage extract was prepared by homogenizing 50 g of a silage sample, previously shown to be free of PCD residues, with 200 ml of water. The filtered water from the silage had a pH of 4.3. The flasks were
incubated at 37*C with shaking for intervals up to 72 hours. For analysis, 15-ml aliquots were filtered through Whatman No. 5 filter paper to remove the suspended particles. The samples were extracted with hexane, passed through a bed of anhydrous sodium sulfate and concentrated to 10 ml.
Determination of PCB Residues. Aroclor 1254 is a
mlxturo"'o? chiorina ted~l>Ipfienyls which produced 17
peaks when analyzed by gas chromatography (Fig. 1).
.
Since pure standards of each peak wore not available,
a problem relative to how to quantify the residues of
PCD'8 in silage and silo wall samples existed. However,
thin problem was not too great in this particular Btudy
because the relative peak heights were the same in
Aroclor 1254, in silo wall chippings and in the silage
(Fig. 1, Table 1). Because of this, only peaks J and
M were used for quantification. The standards were
injected frequently into the gas chromatograph during
the analysis and in amounts which approximated the
levels of residues in the samples. Owing to inter
fering materials, peaks A, B, C and O, P, Q (Fig. 1)
were not always evident in the silago samples.
.p `
Results and Discussion . " - ~-
Gad' chromatographic analysis of silo wail chips
from the farms Included in this study demonstrated that
they did contain Aroclor 1254 residues (Fig. 1). Scan II in Fig. 1 is representative of the results obtained
from the silo,chips and is identical to scan I which is a technical sample of Aroclor 1254. The data shown in
Fig. 1 were obtained using a 10 ft column. However, a
\ .\
'
\i
Figure 1. Gas chromatographic analysis of (I) a technical sample of Aroclor 1254 and (II) of an extract of silo wall chips from farm B. See methods section for operating parameters, ,
412
A
MONS 003374
ft column yielded Identical results except that . peaks B, C and H, 1 were not resolved completely. The farm A silo contained very email amounts of PCD residues, having an average concentration of only 10 .ppm. Farm B contained 10,000 ppm residues of PCB and ' farm C approximately 2,000 ppm.
In the silage, the greatest amounts of residues were in material collected within the first 6 inches of the wall (Tablo 2). The relative peak heights given in Table 1 show that the PCB's in the silage were similar to Aroclor and that the number of peaks were identical. The residue declined rapidly as the distance from the wall increased and none were detected in samples taken 4 to 6 ft from the silo wall. Silage samples taken at 0 to 2 inches from the wall contained extremely high residues and may have resulted, in part, from small flakes of the sealent in the silage. One sample collected 0-1 inch from the wall of silo C, for example, contained 60 ppm residues of PCB's. However, samples taken at the 2-to 4-inch distance also contained high levels of PCD residues which indicated that the con tamination of the silage was not caused entirely by mechanical means.
A decrease in residues was noted in silage samples taken from farm C after a 6 month period. Perhaps the lower levels of PCB residues detected in the second sampling reflect a loss of the PCB as a result of theif movement with the liquids which had drained from the sampling area.
' It was clear from the laboratory experiments that PCB's from the silo wall chips would contaminate distilled water and a silage extract in which they were placed. The silage extract contained 0.42 ppm after 72
v, hours (Table 3). These data suggest that the PCB's contaminate silage by being dissolved in the silage liquor which, in turn, moves from the wall, and down ward, spreading the PCB's over a wide area. This con tamination may be enhanced by the action of automatic feeding dovices working inside the silo which mix highly contaminated silage near the wall with that near the center
In some top feeding silos a layer of silage 3 to 6 inches thick sometimes remains against the walls of the silo and docs not mix with the rest of the silage. As shown in this study, the silage nearest the walls contained the greatest residues of PCB's and if that portion of silage was discarded, it is very unlikely that contamination of the silage would be sufficient
cause contamination of the milk and meat of animals.
\
/\
'Tsr
TABLE X
Relative GLC Peak.Heights of the Major Components in Aroclor 1254, in Sealents from Silo Walls and in Contaminated Silage
SamDle
AD
Peak heloht relative to Peak E E F G H ii
K LM
Aroclor
.21 .49 1.00 .45 .76 .22 .35 .93 .63 .37 .70
Sealent
.20 .43 1.00 .50 .77 .27 .42 1.07 .78 ,4S .92
Silaoe
.30 .64 1.00 .67 .87 .20 .34 1.19
.89 .56 1.02
*See Figure 1.
.
TABLE 2
. Levels of PCB Residues In Com Silage and Silo Wall Chips taken from Dairy Farms where FCB Residues In the Milk had been Reported
PCB Residues. PPM^
Farm
Inches from silo wall
0-2
2-4
6-12
12-24
A
10
0.00
0.00
0.00
0.00
B
10,000 - 24.31
4.02 : .27
.15
C
2,000
31.43 .07 .10
Cc
2 000_______ 15.04
3.40
.13
^Samples collected 3 months after com was placed In sUo.
"limit of sensitivity - 0.02 ppm.
cSamples`collected 6 months after com was placed in silo.
.10 0
36-48 0.00
.13 0 0
48-72 0.00
0 0
0
TABLE 3
.
Level of PCB Residues in Distilled Water and in an Aqueous Extract of Corn Silage at Various Intervals
after the Addition of Silo Wall Chips from Farm C
Hours of
PPM Residues in
Incubation*Distilled water
Silage extract
24
0.02
0.16
48 .03 .25
72_______________.06_____________________.42
aSilo chips incubated, with shaking, at 37*C.
Unlike farms B and C, the silo wall chips from farm
A contained only small amounts of PCB's and the silage was free of these residues. Since PCB residues had been reported in the milk of cows on farm A, it was obvious that there was another source of contamination. Further search for the PCB source on farm A revealed that the feed troughs were the contributing sources. These troughs had been coated with a sealent containing Aroolor 1254, and chips from the bottom of the troughs
contained 8,000 ppm of residues. Care will be required to prevent accidental contamination of animal feed due to the large number of materials that contain PCB's and
the potential of silage and other feed to pickup PCB
residues.,
In all samples analysed, except one, the various components of the Aroclor 1254 mixture appeared to move into and contaminate the silage in an equal manner.
This indicated that there was little or no selectivity in solubility of movement of the compounds that make up the Aroclor material in the silo walls. With the one exception mentioned above, peaks E, G and L (Fig. 1)
were present at twice the amount of the rest. This occurred in the sample from farm B taken 36-48 inches from the silo wall and the total residues levels wore very small. It is possible that the mobility of the components of Aroclor 1254 may vary to some degree. Obviously, more information concerning the compounds in the Aroclor mixture, and other PCB-containing products, must be obtained before their toxicological significanccs as residues In milk and other food
products can be completely assessed. \
References
1 Gustafson, C. G. Environ. Science and Tectf.* 4,
814-819 (1970).
~
\
It
\/
411
r1'
>: '4
2. Reynolds, L. M. Bull. Environ. Contam. Toxicol., ,4, 128-143 (1969) .
3. Risebrough, R. W., Reichle, P., Herman, 5. G., Peakall, D. B., and Kirven, M, N. Nature 220, 1098-1102 (1968).
4. Risebrough, R. W., Reichle, P., and Olcott, H. S. Bull. Environ. Contain. Toxicol. 4, 192-201 (1969).
5. Kocman, J. H., Ten Noever Debrauw, M. C., and DeVos, R. H. Nature 221, 1126-1126 (1969).
6. Armour, J. A., and Burke, J. A. JAOAC S3, 761-760 (1970).
\
i i
i
A
!\
<16
I
muns oajj?a