AA DIRECTOR'S REVIEW MEETING SOLID AROCLOR EXPANSION - ANNISTON
CEA-2080
9:00 A.H. -- November 25, 1969 -- Room 303 -- "C" Building -- G.O.
I. Introduction..................................................................................J. E. Smlth/H. L. Hllllem*
II. Objectives ............................................................... ...................................... .. ..W. E. Vo
III. Summary of Process and Equipment............................................ .....R. A. Yates
IV. Current Status
j
A. Construction........................................................................................... j..R. S.Yates
B. Manning.................................................................................... H. L. Williama/W. E. Voss
C. Training Program.............................................................................
W. E. Voss
D. Overall Timing....................................................................R. S. Yates/W. E. Voss
V. Start-Up Plan......................................................................................................... W. E. Voss
VI. Project Risk Review of PFA..................................................................R. S. Yates/W. E. Voss
0355990
TOWOLDMONOQ48374
0355990.01 TOWOLDMONOQ48375
SOUP AROCLOR EXPANSION - ANNISTON
sba-mq
START-UP OBJECTIVES
1. Demonstrate the safe operation of the expanded Solid Aroclor facility to produce 20.0 M lbs/year of "In specification" Aroclor 5460.
\ $ iftjj
ij -1
2. Effectively define any problems which occur In meeting objective Number 1, and resolve with the proper group (Mfg., CEP, Malnt., etc.).
' ",
3. Demonstrate the ability of the expanded facility to meet standard manufacturing cost.
A. Start-up cost do not exceed budget.
'
ii
5. Determine the ability of the expanded facility to produce Aroclor
1
5460 that can be PDA approved (0.4% PCB).
, ..
a
0355991
.1
I
TOWOLDMONOQ48376
0355991.01 TOWOLDMONOQ48377
SOLID AROCLOR EXPANSION AW11ISIOH - CEA 2080
PROJECT SCHEDULE
1. Completion of Utility and Thermlnol Circulating Systems.
1/2/7.0
2. Start-Up of Thermlnol Circulating Systems.
1/5/70
3. Complete Construction on Process Equipment.
1/15/70
4. Check Out Process Equipment and Calibrate Instruments.
1/15/70 - 1/30/70
5. Start-Up New Facility for Production of Aroclor 5460.
2/2/70
6. Complete Demonstration of Design Yields and Bracket III Capacity (See attached 1970 Sales Requirements).
2/28/70
7. Complete Demonstration of Dealgn Capacity (20 M lbs./yr. rate).
3/15/70
PROJECT DEMONSTRATION
Process simulation or check-out of this equipment Is limited to sctual production of Aroclor 5460.
Project demonstration will consist of Introducing Santowax R Into the weigh tank with a thorough check of equipment operation and Instrument accuracy.
From the weigh tank, one chlorlnator will be charged, chlorination accomplished and all features of the equipment checked out before the second chlorlnator la put Into service.
The 5060 batch produced In .the first chlorlnator will be tranaferred to and held In the blow tank while the aecond chlorlnator la being cycled through a batch. During thla holding period, the blow tank equipment testing can be started.
f i
r
u *I--
1
tl
S'*
0365W2
TOWOLDMONOQ48378
Project Demonstration (Contd.)
2
When both chlorlnators have produced a batch of 5060and the blow tank haa been checked out with the double batch the materialwill be tranaferred to the atlll for refining to 5460.
Throughout thla teatlng period all equipment and lnatrumentatlon will be obaerved utilising round-the-clock technical eupervlalon aa will routine operator attention. All equipment must perform well In each step of the process before the next step la attempted.
It la estimated that four (6) chlorlnator batches and two (2) atlll batches will be processed In the system before all corrections and modifications are made.
' At such time as all supervision and CED personnel agree that the equipment Is In operating condition, the facility will be operated, at Bracket 3 capacity.
Special Note must be given to the fact that forecasted sales requirements and Inventory capability do not permit operation at design capacity (20.0 H lbs/yr.) for a full month In early 1970. Therefore, achievement of design capacity will be a judgment factor utilising all personnel Involved In the start-up
and short period production rates.
f. Li |`
.
X i
V It
* ,
< ! `
0355993
.4 *
TOWOLDMONOQ48379
SOUP AROCLOR EXPANSION ANNISTON - CEA 2080
1970 February March April May
FORECASTED SALES REQUIREMENTS
5460 1,095,000 1,159,000 1,132,000 1,245,000
Mcltt.t_____________________
2080 Daalgn
23
Caoacltv
2,467,000
1,235,000
1,666,700
2,467,000
1,235,000
1,666,700
2,467,000
1,235,000
1,666,700
2,467,000
1,235,000
1,666,700
TOTAL 1970- 12,200,000
14,820,000
20,000,000
TOWOLDMONOQ48380
<\
RISK ANALYSIS
I I
4
0355994*01
ti
1
I TOWOLDMONOQ48381
?
POTKHTIAL PROBLEM ANALYSIS
BMWIW - JfflWWH
CEA-2080
SPECIFIC POTENTIAL PROBLEMS I. RAW MATERIALS
1. Santowax R a. High percent Quatraphenyla b. High percent Biphenyl c. High percent water d. Availability
2. Chlorine a. Quality b. Availability
3. FeCU a. Quality - percent water b. Availability
4. Lime a. Quality - percent water b. Availability
u. fflWRmmw tm
1. Welsh Tank a. Incorrect weight b. . Inadequate Catalyat c. Poor or no agitation d. Water leak Into tank
PROBLEM
70 10 50 10 10 6 50 10
10 2 10 10
50 3 10 10
10 6 10 10
10 5 40 6 10 4 10 6
1
i
i | f , , 700 500 ; 60 500
?! 20 100
S
150 7
100
60 100
50 240
40 60
4. fHi.!
\ i.
0355995
TOWOLDMONOQ48382
Potential Problem Analysis Solid Arodor Expansion - CEA-2080
2
_____hotto. ?9TBBTiAf) mwmmsi&i_______________________________________ sums______ m II. CHLORINATION AREA (Contd.l
1. Welsh Tank (Contd.)
Fire . Sampling hazard 8* Pump failure h. Line pluggage
10 10 100 10 10 100 10 10 100 20 5 100
ChlortMtws a* Liquid chlorine Into chlorlnator b. Fire c. Circulating pump failure d. Demister pluggage or failure a* Overcharge f. Poor or no temperature control 8- Poor or no chlorine flow control h. Out of spec chlorination level 1. Plugged lines J. Chlorine flow failure k. Soft point determination i. Thermlnol leaks Into batch ms Overpressurize
10 7 70 10 10 100 30 10 300 50 6 300 60 4 240 60 6 240 50 4 200 40 8 320 30 7 210 10 7 70 10 7 70 30 10 300 10 8 80
0355996
TOWOLDMONOQ48383
Potential Problem Analysis Solid Aroclor Expansion - CKA-2080
3
SPECIFIC POTENTIAL PROBLEMSPROBLEM ii. wmimw tm (contd.)
SERIOUS
TOTAL
3. Blow Tank 1, Overcharge b. Thermlnol leaks c Temperature control d. Insufficient air e. Ejector plugged f. Pump failure 8* Insufficient HC1 removal h. Overpressurize 1. Water In product
J. Off-Spec. Material
k. 5060 production capability i. Rework off-spec, material
20 10 10 10 20 20 20 20 70 10 100 50
|j
1
7 140 8 80 5 50 6 60 7 140 4 80 5 150 7 140 2 140 3 30 5 500 6 300
Off-Gas Svatem a. Contaminate blow tank b. Temperature control-condenser c. Water d. Overpressurize e Plug Condenser f. Plug return line g. Pump failure h. Off-gaa line capacity 1. Off-gas line pluggage
J. Thermlnol leaks
20 7 140 30 6 180 10 6 60 30 5 150 30 6 180 30 5 150 20 4 80 20 8 160 40 6 320 20 8 160
035599?
TOWOLDMONOQ48384
Potential Problem Analyst* Solid Aroclor Expansion - CEA-2080
4
------ BEBCffK MBIMi PfiPBLE^S_______ _PROBLEM III. STILL AREA
1. Still a. Insufficient vacuum b. Overcharge c. Cyclone Operation poor d. Lime addition equipment failure e. Incorrect lime charge f. Poor lime mixing g. No. yield Improvement h. Montar draw-off 1. Pump failure j. Condenser design k. Condenser pluggage 1. Thermlnol leak m. Condenser temp, control n. Pump replacement Still Heater a. Coll rupture b. Gas explosion c. Coll pluggage d. Temperature control e. Coll flow Instrument f. Coll replacement g. Heater capacity h. Sucking coll
SERIOUS TOTAL
50 60 20 40 30 70 80 60 40 20 20 20 20 40
20 40 20 10 90 50 30 60
9 4 4 3 6 2 8 6 9 8 S 8 5 4
S 9 8 8 3 3 6 7
M
450
i; v.
240
80 %
120
180 ;|
140
640 h 360
360
160
160
160
100
160
160 360 160
80 270 150 180 420
0355998
TOWOLDMONOQ48385
Potential Problem Analyst* Solid Atoelor Expansion CEA-2080
1 .........
' "
srnms ECTffllAkJygBlftMSproblem
........ .
serious
III. STILL AREA (Contd.) 3. Still Receiver
a. Level control
b. Vacuum problems
Ce Pump failure d. Plugged lines
6e Temperature control
f. Off-spec. Material
g. Water 4. Still Jet
Pluggage
b. Capacity
Ce Corrosion d. Catch tank temp, control
* Leak In Barometric leg f. Drain knockout tank
S* Level Indication (lack of) h. Jet breakage
1. Steam quality
5
................................... i ------------ '.i-
total
'
: 30 6 180 10 6 60 20 4 80 20 4 80 20 4 80 30 6 180 10 7 70
50 5 250 30 8 240 30 8 240 20 5 100 30 5 150 20 5 100 20 5 100 20 5 100 20 5 100
MAIN THBRMINOL SYSTEM a. Pump failures b. Distribution Ce Temperature control d. Heater capacity Thermlnol leaks
40 9 360 30 8 240 30 4 120 20 8 160 20 8 160
0355009
TOWOLDMONOQ48386
Potential Problem Analysis Solid Aroelor Expansion - CEA-2080
____________ SPECIFIC POTENTIAL PROBLEMS_____ ___ V. a. Inability to achieve Plant Standards
VI. MANPOWER a. Labor hog
VII. SAFETY a. Thermal burns b. Use of torches c. Montar draw-out
'
VIII. HC1 AREA a. Absorber capacity b. Drowning Jet capacity c. Waste treatment capacity
IX. mums a. Steam b. Water c. Air d. Electricity
'
f
6i
PROBiffii__ SSUS&S___ IM
30 8 240
30 9 270
30 9 270 1 20 9 180 30 9 270-1
80 5 400 10 8 80 50 8 400
10 8 80 10 8 80 50 8 400 10 8 80
0356000
TOWOLDMONOQ48387
POTENTIAL PROBIEMS
LIKELY CAUSES
I. RAH MATERIALS
PREVENTION lake Preventive Action
or Accent Risk
PROTECTION Set Contingent Action
or Accent Risk
PROVIDE FOR INFORMATION
1. Santowax R
a. Quatraphenyl in SW R
1) Process control at S/R column
2) Pump wrong S/R to Aroclor
1) TSD Study-Process Knowledge
2) Operator training
1) Adjust 5060 softening point
2) Biphenyl Dept, blend S/R
b. Biphenyl in S/R 1) Process control 1) Operator training-
at Biphenyl stil
understanding of
need
1) Sell as 5060
2) Analyze Biphenyl still feed and Santo. C and control <0.31 Biphenyl in S/C
2) S/R analysis to proceed Santowax R charge
1) Analyze prior to use at S/R
2) Plot trends
1) FDA Specs
'
2) Plot trends
d. Availability
1) Insufficient S/R 1) Increase S/R capacity capacity
1) Debottleneck S/R capability
1) Increased capacity required in 3rd Qtr. 1971
II. CHLORINATION AREA
1. Heidi Tank b. Inadequate
Catalyst
2. Chlorinators c. Pump Failure
1) Operator error
1) Accept risk
2) Catalyst quality 2) Accept risk
3) Poor mixing
3) Accept risk
1) Operator training 2) Visual inspection 3) Agitator shutdown slsrm
Study Catalyst' Quality and effects on process
1) Overloaded motor 1) Non-overloaded motor
2) Grounded motor
2) Accept risk
3) Seal failure
3) Accept risk
4) Errosioo/Corrosic l 4) 316 SS pump
1) Alarm-Shut chlorine valve
2) Alarm-Shut chlorine valve
3) Jacketed pump face-Opr. and mechanic training
4) Std. chlorinetor pump
Observe pumps and seals for wear at regular intervals
to o **
TOWOLDMONOQ48388
POTENTIAL PROBLEMS
LIKELY CAUSES
PREVENTION Take Preventive Action or _______ Accept Risk____________
PROTECTION Set Contingent Action
or Accept Risk_______
PROVIDE FOR INFORMATION
II. CHL0R1. AREA
2. di1nHnfril
d. Demister plug- 1) Overcharged
gage or failure
chlorinator
2) Burpped chlori nator
3) Lack of heat
4) Water in system
1) Weigh charge-blow tank level
1) Accept risk
2) Operator training-Proper 2) Accept risk
chlorine addition, chlo
rine flow, control failur^
3) Accept risk
3) Tracing on demister
4) Do not charge wet batch 4) Accept risk
Study need for chlorinator level indicator
5) Plugged drain lin^ 5) Removed cup in new design 5) Accept risk
6) Drain line fell off
7) Corrosion
6) Accept risk 7) 316 SS wire
6) Visual inspection 7) Accept ride
e. Overcharge
1) Heigh tank oper.
1) Monthly check scales Interlock prevent pump ing in S/R while pimping out S/R to chlorinator
1) Heigh tank overcharge alarms
Study need for chlorinator level indicator
2) Incomplete pump 2) Accept risk out of chlor.
2) Blow tank level in dication
f. Poor Cblorinator 1) Circ. pump con
1) Accept risk
Temp. Control
dition or failure
|2) Product cooler or 2) Jacketed w/Thermlnol lines plugged
1) Pump shutdown stops Cl, flow and alarms
2) Hi temp, stops CI2 flow|
and alarms
3) Therminol cool 3) Accept risk ing system fails
Therminol low flow alarms
4) Temp. Control loop failure
5) Main Therminol distrib. system
hot for circ. lines
4) Accept ride 5) Accept ride
Hi-Lo Therminol temp. alarms
Redundant temp, in dication Therm, low flow alarm
0356002
*
TOWOLDMONOQ48389
POTENTIAL PROBLEMS
LIKELY CAUSES
PREVENTION Take Preventive Action or
Accent Risk
PROTECTION Set Contingent Action
or Accent Risk
PROVIDE FOR INFORMATION
II. CHLORI. AEEA
2. Cll1r<ul-lir
g. Poor CI2 Flow Control
1) S/R or 5060 back in 1) Accept risk line
2) CI2 tar In line to 2) Accept risk vaporizer
1) Steam trace and thermon
fron aanual valve to
chlorinator
.
CO2 blow upstream fron
Orifice
2) Work with vendor
3) Flow control loop failure
3) Accept risk
3) Accept risk
4) Failed distributors 4) Monel distributors
4) Periodic inspection
5) Pressure Control loop failure
5) Accept risk
5) Accept risk
h. Chlorination Level
1) Undercharge of chlorinator
1) Continuous Sp.Gr. Monitoring
1) Operator training and monitoring of operation
2) Circulation poor
2) Continuous Sp.Gr. Monitoring
3) Cl2 Flow high
3) Continuous Sp.Gr. Monitoring
4) Stepper-Timer
4) Operator checks
i. Plugged Lines
1) Hot theminol system 1) See IV. a. and b. failure
2) Over chlorination 2) See II. 2. h.
3) Pump failure
3) See II. 2. c.
1. Theminol leaks into Product
4) Downtime
4) Proper line drainage and
heating provided
1) Jacketed piping
1) No Jacket over welds
2) Natl, of constructio i2) Stainless steel
3) Hater in Santowaz 3) Accept risk
4) Accept risk
1) Accept risk 2) Accept risk 3) Process control in S/R
Dept. Preventive Maint.
0356003
(A ..... ------
TOWOLDMONOQ48390
POTENTIAL PROBLEMS
LIKELY CAUSES
PREVENTION Take Preventive. Action or
Accent Risk
PROTECTION Set Contingent Action
or Accent Risk
II. CHLORI. AREA
3. Blow Tank
k. 5060 Production 1) Off Spec. 5060
capability
in blow tank
United
1) Accept risk
1. Rework of offSpec. Material
1) Poor process control 1) Operator training-improved process control
1) Quality control in S/R
Dept. Provide line to #2 blow tank 1) Provide ability to return to blow tank for rework
6. Off-Gas Svsten
i. Off-Gas Line Pluggage
1) Overcharged chlori. 1) See II. 2. e.
2) Demister Plug
2) See II. 2. d.
3) Line size
3) Accept risk
3) Install larger line
III. STILL AREA
1. Still a. Insufficient
Vacuua
b. Overcharge
1) Pump packing leaks 2) 3-May valve
1) Proven packing material and method
2) Accept risk
1) Spare pump 2) Operator training
3) Condenser Design
3) Proven design
3) Accept risk
4) Jet design
4) Accept risk
4) Accept risk
5) Knock-Out Pot
6) Condenser Tenp. Control
7) Receiver Overcharge
8) Cyclone design
5) Tangential Entry Plate Coils 5) Accept risk
Heating & Cooling
6) Accept risk
6) Accept risk
7) Level indication 8) Accept risk
7) Operator inspect when in doubt
8) Accept risk
1) Level switch failure 1) Accept risk
1) Operator stick assure
PROVIDE FOR INFORMATION
V009510
^ *' / -w?;L_A-- ...
TOWOLDMONOQ48391
POIEHTIAL FROBIEMS
III. STILL AREA
LIKELY CAUSES
FREVEHTIOH Take Preventive Action or
Accent Risk
1. Still
g. Ho Yield Improve 1) Santovax quality ment 2) Receiver too small
1) Biphenyl & TSD efforts 2) Accept risk
3) Still pump NPSH
3) Sump on still pot
4) Beater hold up
4) Sump on still pot
h. Montar Draw-Off Problems
1) Still bottom nozzle 1) Adequate size design
2) Long draw off line
3) Large Ho. of drums to handle
2) Therminol jacketed lines sloped
3) Improved yield
1. Pump Failure
1) Long shaft
1) Accept risk
2) Lime pluggage
2) Accept risk
2. Still Heater b. Gas Explosion
e. Coll Flow In strument
h. Sucking Coll
1) Failure of safe guard system
2) Operating error
3) Gas leak
1) Pluggage
1) Accept risk
2) Operator training 3) Accept risk 1) Accept ride
1) Plugged vent valve 1) Therminol heated vent nozzle and valve
PROTECTION Set Contingent Action
or Accent Risk
PROVIDE FOR mFORKATION
1) Accept risk rework
2) Pump out receiver during batch
3) Accept risk
4) Accept risk
1) Accept risk
2) Accept risk
3) Provide increased roller conveyor capacity
1) Spare pump
2) Lower yield and don't distill as far down
Justify Sandvik Belt
1) Accept risk with proper maintenance
2) Gas test before Ignition
3) Gas test before ignition
1) Coil outlet temperature Hi shutdown
1) Operator Rod Out
035600$
- .. : .... -'vJ-A. _ ___
TOWOLDMONOQ48392
POTENTIAL PROBLEMS
LIKELY CAUSES
PREVENTION Take Preventive Action or
Accent Ride
PROTECTION
Set Contingent Action or Accent Risk
PROVIDE FOR INFORMATION
lit. STILL AREA
A. Still Jet
a. Pluggage
1) Knockout Tank
1) See III. l.a.
b. Capacity c. Corrosion
2) System Air Leaks
2) Accept Risk
3) Product Temperature 3) Accept Risk too high
1) Jet Design
1) Accept Risk
1) HC1 in system
1) Accept Risk
2) Overheated bottoms liberate HC1
2) Accept Risk
2) Test for leaks and repair
. 3) Monitor condenser temp, control system
1) Accept Risk
1) Prevent water in system
2) Instrument maintenance operator training
IV. MAIN THERMINOL SYSTEM
a. Pump Failure
1) Low level in system 1) Horizontal pump eliminate leaks level indication
1) Accept risk
b. Distribution
2) Seal failures 1) Piping Sizing
2) Seal guard system
1) Improved design better temperature indication
2) Accept risk 1) Piping modifications
V. HOUSEKEEPING
a. Inability to Maintain Plant Standards
1) Therminol leaks 2) Product leaks
1) Improved design using 316 SS
2) Equipment arrangement
1) Proper emphasis on housekeeping
3) Operating errors
3) Operator training
0356006
4) System pluggage
4) Improved therminol distrib.
jacketed lines, better
system drainage 5) ^tUig stations properly
6) Sample funnels returned to
weigh task.
1
----------
TOWOLDMONOQ48393
POTENTIAL PROBLEMS
VI. MANPOWER HOG
LIKELY CAUSES
1) Manual Operating functions
2) Housekeeping probleas
PREVENTION Take Preventive Action or
Accent Risk
1) Instrumentation on levels. flows, temperatures, gravities, control room layout improvements.
PROTECTION Set Contingent Action
or Accent Risk
1) Proper instrument maintenance
2) Improved equipment design and layout. Provide propel housekeeping equipment
2) Increased emphasis on housekeeping
PROVIDE FOR INFORMATION
Continuing Manpower study to reduce oper ating load by modifications or new design
3) Plugged lines
3). Jacketed piping, improved therminol distribution, insulation and tracing
3) Accept risk
VII. SAFETY
a. Thermal Burns
1) Uninsulated piping ' 1) Adequate Insulation on
and vessels
hazardous areas
2) Sucking coil
2) Heating on vent valve
3) Leaks
3) Accept risk
4) Lighting gas heatei 4) Operator training
c. Montar Draw-Out 1) Fuses
1) Fume Collection System
2) Sticking rollers
2) Proper maintenance and housekeeping
1) Safety awareness by all concerned
2) Personal Protective equipment
3) Proper maintenance
4) Follow procedures
1) Personnel protection equipment
Safety Audit after three months operation
3) Overfilling drums
3) Accept risk
3) Operator training
4) Insufficient rolle 4) Provide for navimum
conveyor
number of drums
0356007
TOWOLDMONOQ48394
POTENTIAL F&OBLD6
LIKELY CAUSES
VIZI. HC1 AREA a. Absorber Capacit 1) Increased BC1 load
c. Haste Treatment
1) Increased load
PREVENTION Take Preventive Action or
Accent Risk
1) larger drowning jet Automatic drowning operation
1) Accept risk
PROTECTION Set Contingent Action
or Accent Risk
PROVIDE FOR INFORMATION
1) Further CED effort in Muriatic Acid area
1) Provide additional neutralization facilities
TSD Study and Definition in HC1 Area
IX. UTILITIES c. Air
1) Insufficient air for new instru ments
2) Dryer capacity
1) All available instrument air compressors and dryers in good operating con dition
1) Purchase additional air capacity
Study improved central air system
0356008
= " .V.- , V SUP .Si ' -J5 *-
TOWOLDMONOQ48395
STAIT-OP
0356008*01
TOWOLDMONOQ48396
SOLIP AROCLOREXPANSION ANNISTON - CEA 2080
The start-up expenses for the Solid Aroclor Expansion are estlnated at $93,310. The detailed'budgets for the Preparation and Operation Phaaea are Included In this section. This budget has only recently been prepared and Is not approved.
SUMMARY Preparation------------------------
Per cent of Approved Capital-------------- ----- 8.5
Actual and Estlnated Expenditure In 1969 - Preparation--....................................-........... $20,230
Estimated Expenditure In 1970 Preparation and Operation ------------------------------ $73,080
j |
fi >, i 1i
",
0356009
TOWOLDMONOQ48397
Manufacturing Wages Manufacturing O.H. Salaries Salary O.H. Supplies Clothing & laundry Travel Stationery-Printing Mechanical Expense Meetings & Conferences
TOTALS
SOI.TP A<1C11 KTPAMSIOH ANNISTON - CEA 2080
JOB BO. 916.56
PREPARATION PHASE_________________ START-UP BUDGET
1st Qtr. 2nd Qtr. 3rd Qtr. Oct. Nov.
1969
1969
1969
1969 1969
Dec. 1969
----
--
-- -
--
---
"
--
--
867
895 1,690
20 2,000 7,500
155 158 308 4 360 1,350
--
70 - 100 2,000
---
"-
-
164 150 189 - 750 500
-- - - - 200 500
1,186
1,203
2,257
300 24 3,410 12,150
Jan. 1970 4,000
700 7,500 1,350 2,000
150 200 200 5,000 450 21,550
TOTAL 4,000
700 20,472
3,685 4,170
150 1,953
900 5,000
750 41,780
0356010
TOWOLDMONOQ48398
PREPARATION PHASE START-UP BUDGET
' iaam, pbmp
'
MANUFACTURING WACES Training for 12 men AO overtime houra
$4,000
. Operating peraonnel for the expanded plant will be thoae now operating In tha Aroclor Department. Theae operatora are familiar-with the proceaa and the general type of equipment being Installed on CRA 2080. Due to their continuing operating dutlea up to the time of atart-up of CEA 2080, all training muat be performed on overtime.
SALARIES
$20,472
Through October 1969, only the required portion of the manufacturing representative's salary has been charged to the Preparation Phaaa. Late In November one technical man will be picked up to begin detailed preparation of the start-up manual. In December and January tha budgat provides for full time utilization and training of four (4) shift supervisors, the start-up aupervlsor, and the manufacturing repre sentative.
gVPfUfig
Houaekeeplng Equipment Safety Equipment Safety Slgna Utility Lockera and Cablneta Training Supplies Other Miscellaneous purchases
$4,170
TRAVEL
$1,953
Trips for the Manufacturing Representative to visit CED. Attendance of concerned peraonnel at the Director'a Review Meeting requires the large budgeted amount In November.
MECHANICAL EXPENSE
Inetrument Check-Out and Calibration IPO's
$5,000
I : L ' `i ' .< f>
!
fl
0356011
TOWOLDMONOQ48399
Raw Materials Steam Salaries Salary O.H. Factory Supplies laboratory Production Research Mechanical Expense Performance Volume
TOTALS
sm.Ti> aannflR EXPAHSIOH AHHISTOH - CEA 2080
OPERATIOH PHASE - START-PP BPDCEX
COST ABOVE 1970 SOUP AROCLOK COST STAKDARD
February 1970
5,100
1,000
6,000
March 1970
-
2,500
Total
--
5,100 1,000 8,500
1,080
450 1,530
1,000
500
1,500
1,200
600
1,800
1,000 15,000
10,000
1,000 25,000
6.100
6.100
37,480
14,050
51,530
2109M 0
TOWOLDMON0048400
OPERATION PHASE - 3TART-PP BUDGET EXPENSE DETAILS
BASISs Begin producing Aroclor 5460
Schedule Production-Bracket 3
New facility will produce - Feb. 9OX Bkt. 3
Mar. 100% Bkt. 3
Yield on Raw Materials -
Feb. 73%
Mar. 80%
2/2/70 1,235,000 1,115,000 1,235,000
YTO VAMOSE.
Peb. 1970s 1,115,000 ($6.09 - $5.64) 100
$5,018
PERFORMANCE VOLUME
Feb. 1970s (1,235,000 - 1.115.000) $5.09 100
MKHAMKAt HMfflgB
Feb. 1970s Appropriation Request Approval for Start-Vp Modifications
Mar. 1970s Additional Correction Expense
$6,108 $15,000 $10,000
4
I
4
II
.1; $ I I
1
'l
'ij
s|
0356013
TOWOLDMONOQ48401