Document wKzNEnNDX6j0KLqD2ErOqjX66
VI#
|#CSCIENTIFIC ILrVsCaRPQRATIQN
P.O. BOX 449, S. NORWALK, CT. 0B856, 203/B3B-4537
PRICE LIST July 1, 1974
201-2120
201-1120 201-2121 201-1121
MIRAN-II GAS ANALYZERS
MIRAN-II Infrared Gas Analyzer With Twenty Meter Gas Cell:
Analytical and Reference Measurements for Long Term Stability, Linear Absorbance Readout, Continuously Variable Zero and Span Controls, Meter Readout, Connector for Recorder Output, Variable Path Gas Cell (3/4 to 20 Meters), Evacuable and Pressurizable to 10 Atmospheres, NaCl Windows...................................................................$4,900.00
MIRAN-II Infrared Gas Analyzer With Twenty Meter Gas Cell:
Same as 201-2120, except No Reference Measurement..................................................................... $4, 800.00
MIRAN-II Infrared Gas Analyzer With One Meter Gas Cell:
Analytical and Reference Measurements for Long Term Stability, Linear Absorbance Readout, Continuously Variable Zero and Span Controls, Meter Readout and Connector for Recorder Output, One Meter Gas Cell, Pathlength 1.0 Meters or 0.5 Meters................................................ $3,800.00
MIRAN-II Infrared Gas Analyzer With One Meter Gas Cell:
Same as 201-2121, except No Reference Measurement..................................................................... $3,700.00
NOTE: Substitution of AgBr Windows Instead of NaCl Windows.................................................................. $ 160,00
UCC 094158
201-2130
201-1130
200-0101 200-0102 200-0103 200-6600 200-6610
-2-
GENERAL PURPOSE ANALYZERS
MIRAN-II General Purpose Infrared Analyzer: Analytical and Reference Measurements for Long Term Stability, Linear Absorbance Readout, Continuously Variable Zero and Span Controls, Meter Readout and Connector for Recorder Output, Sampling Compartment Covered by Rugged Aluminum Casting, Sealed and Purgeable. Sampling Platform Compatible with any MIRAN-I Accessories......................................................................$3,250. 00
MIRAN-II General Purpose Infrared Analyzer: Same as 201-2130, except No Reference Measurement......................................................................$3,150. 00
ACCESSORIES
High Set Point Alarm: Integral to Analyzer, Provides Relay Closure under Alarm Condition, No Audio or Visual Indicator............................................................................ $ 200. 00
Cell Slide Mount.......................................................... $ 100. 00
Control Box Extension Cable (4 Feet) for Remote Mounting of Controls...................................................$ 50. 00
Flow-Through Internal Reflection Cell: Stainless Steel Construction, 1/4" O.D. Inlet and Outlet Ports, Including Mounting Block, Less Reflector Plate...................................................$ 400. 00
Heated Flow-Through Internal Reflection Cell: Same as 200-6600 with Heating Cartridge, Temperature to 200C and Temperature Controller..........................................................................$ 625. 00
UCC 09415
-3-
200-6620
200-6601 200-6602 200-6603 200-6604 200-6605
206-2120
Minimum Volume Flow-Through ATR Cell: Stainless Steel Body, 1/8" O.D. Inlet and Outlet, Including Mounting Block, But Not Including Reflector Plate............................. $
400.00
KRS-5 Plate, 52 x 8 x 1 1/2 mm., for use
with 200-6600 Cell..................................................... $ 100.00
Ge Plate, 52 x 8 x 1 1/2 mm., for use with lUc* -
200-6600 Cell.......................
$
Si Plate, 52 x 8 x 1 1/2 mm., for use with 200-6600 Cell.................................................................. $ 125.00
ZnSe Plate, 52 x 8 x 1 1/2 mm., for use with 200-6600 Cell............ ..................................................... $ 150:00
Saphire Plate, 52 x 8 x 1 1/2 mm., for use with 200-6600 Cell.......................................................$ 600.00
MULTI-SAMPLE POINT AMBIENT AIR MONITORS
MIRAN-II Infrared Sensing Head: Analytical Wavelength: To be specified. Reference Wavelength: To be specified.
Twenty Meter Variable Path Gas Cell. Calibration Curves for Specific Analysis.
Leeds & Northrup Speedomax H Multi-Point Recorder.
Six Sample Inlet Ports Controlled by Nylon Solenoid Valves.
Cycle Time One Minute Per Point, Six Minutes Total.
Manual Bypass Valve for Calibration Checks. Switches to Eliminate Individual Valves from
Automatic Cycle or to Continuously Monitor a Single Sample Point. Sample Pump Capable of Pulling Samples 200 Feet Through 1/2" I.D. Tubing. Internal Plumbing: Nylon, Teflon, Stainless Steel. (Plumbing from Sample Point to Instrument Location is Not Included.)
Ucc 094160
-4-
206-2120 continued
206-1120
212-2120
212-1120
System Housed in a NEMA-12 General Purpose Enclosure (Supplied with Legs for Free Standing Installation), except for the
Sample Pump which is mounted externally. Particulate Filter for each Sample Line...$11,250.00
Multi-Sample Point Ambient Air Monitor: Same as 206-2120, except No Reference
Measurement...................................................................... $11,150.00
Multi-Sample Point Ambient Air Monitor: MIRAN-II Infrared Sensing Head:
Analytical Wavelength: To be specified. Reference Wavelength: To be specified. Twenty Meter Variable Path Gas Cell. Calibration Curves for Specific Analysis. Leeds & Northrup Speedomax H Multi-Point Recorder. Twelve Sample Inlet Ports Controlled by Nylon Solenoid Valves. Cycle Time One Minute Per Point, Twelve Minutes Total. Plumbing System Same as 206-2120..................... $12,500.00
Multi-Sample Point Ambient Air Monitor: Same as 212-2120, except No Reference Measurement............ ......................................................... $12,400.00
NOTE: Substitution of AgBr Windows Instead of NaCl Windows on Twenty Meter Cell............ $
160.00
ACCESSORIES TO AMBIENT AIR MONITOR
206-0111 206-0112
Indicating High Set Point Alarm: Calibrated and Adjustable Full Scale, Manual Reset, Red & Green Indicating Lights, Terminals to Drive Additional Audio or Visual Signal.
Includes 200-0101 Integral Alarm..................... $ 325.00
Positive Pressure Sample Pump:
Pimp Located on Inlet of Gas Cell, Stainless Steel Internal Construction (Air Control Model G-3). Cycle Time Increased to Two Minutes per Sample Point............ ........................... $
500.00
UCC 094161
220-2120 220-2121
-5-
CARBON DIOXIDE ANALYZERS
Low Level C02 Analyzer: MIRAN-II Infrared Sensing Head:
Analytical Wavelength: 4.26 microns. Reference Wavelength: 3.99 microns. Continuously Variable Zero and Span Controls. External Optical Path Sealed and Purgeable. Variable Path Gas Cell (3/4 to 20 Meters). Evacuable and Pressurizable to 10 Atmospheres. Minimum Detectable .05 ppm (One Atmosphere). Maximum - 1/2 percent. Range - Variable, Controlled by Pathlength and Span Adjustments.............................................$4,850.00
Ambient C00 Analyzer: MIRAN-II Infrared Sensing Head:
Analytical Wavelength: 4.26 microns. Reference Wavelength: 3.99 microns. Continuously Variable Zero and Span Controls. External Optical Path Sealed and Purgeable. One Meter Gas Cell. Sensitivity - One ppm at Standard Temperature and Pressure............................................................... $3,750.00
kirk
NOTE: MIRAN-II Analyzers are set up to operate on 115 volts, 50 or 60 cycles. They can be easily modified for 230 volt, 50 or 60 cycle operation. Specify if 230 volt wiring is desired. The output of the MIRAN-II is 0 to 2 volts D.C.
kirk
The above prices are F.O.B. South Norwalk, Connecticut and are subject to change without notice.
UCC 094162
SPARE PARTS LIST
MIRAN-II ANALYZER
63-0002
63-0003 63-0008 63-0032 65-0059 65-0003 65-0004 999-6027 999-6028 999-6045 999-1147
Source Assembly Pre-Amplifier (Excluding Detector & Lens) Detector
Detector Lens, AgBr
Main Circuit Board - Sinjfie Channel Main Circuit Board - Difi:erence Output Motor Start Board Transistor 2N4918 Transistor NJE3055 Transistor E271 Fuse, 1 Amp
TWENTY METER VARIABLE PATH GAS CELL
5669 5670 63-0033
AgBr Window with Holder NaCl Window with Holder Focusing Lens, AgBr Cell Rework - Recoat and Realign Mirrors
Service)
(Factory
AMBIENT AIR MONITORING SYSTEM
999-7132 999-7133 999-7134
999-7024 999-7002 999-3507
65-0036
65-0037 999-7023
65-0039 999-1471 999-1474
999-1475 999-1477
999-1147 999-1470
Chart Paper (Leeds & Northrup #660182) Print Mechanism Assembly - 6 Pt. (L & N #324435) Print Mechanism Assembly - 12 Pt. (L & N #036292)
Solenoid Valve Vacuum Pump Replacement Cartridge for Particulate Filter
Solenoid Drive Board - 6 Pt. Solenoid Drive Board - 12 Pt. Input Relays (L & N #036292) High Point Alarm Board Lock-in Relay Fuse, 3 Amp Slow Blow (Pump) Fuse, 1 Amp Slow Blow (Recorder) Fuse, 15 Amp (Heater) Fuse, 1 Amp (Solenoid Drive System) Light 656 (Alarm Indicators)
$ 45.00 5250.00
$100.00
$ 75.00 $500.00 $500.00 $ 75,00 $ 3.00 $ 4.CO $ 3.00 $ .15
$190.00
$110.00
$150.00
$150.00
$ 4.50 $ 7.00 $ 7.00 $ 30.00 $ 80.00 $ 25.00 $125.00 $200.00 $ 7.50 $150.00 $ 9.00 $ .25 S .25
5 .25
$ .15 $ .50
The above prices are F.O.B. South Norwalk, Connecticut and are subject to change without notice.
7/1/74
UCC 094163