Document wKkNj8YL5vvGOKe9EbMamqngE

r*ROGRL$S REPORT TECH SIC AL SERVICES DEPT. - W.G. KRUMMRtCH PLANT W.G. KRCMM RICH PLANT joe no. _91370:1716 r.iJ REPORT NO, RESEARCH GENERAL OFFICE DAT E pcJ H.C. CARDER [ | J.M. CONNAUGHTON [ | T.W. OALTON fjl W.G.Kramper ii. J .R. Savage ti D.E. Harris (K| P.E. MEISl ER f.X V. Brawley *[ ] W.. PAP AG EORG E n jj^j H.. PATRICK u *PC|J.R. McClain n *Bcl D.C . Armstronf n *(^j D. UANNA (J P.W. EDWARDS G C8R.E. Soden fjtC.E. ANAONOSTOPOLUS [7} H.L. MINCKL ER fr] J.E. SMITH ITIIO (jt| W.. KELLOGG *tX) L.C. FUHRMEISTCR Oc H.L. Hubbard (2 A. MULLENDORE O H.W. Bucknei: Q L.E. KLEIN *(xJ Efltunnmgsosnion e .unsoTi.r P.G.Benignus J . Mol1oy *&) R.G. Moody klJ.J. Luecken 1:1 n n MO MCCCIVK OH .It lie TI ON .... .......... XT J.G. Bryant, title: AROCLOR: PROCESS IMPROVEMENT PLAN personnel: d. r, Middleton (J. R. Savage) problem: Report status of present work and present future plans. summary: The status of the previous Process Improvement Plan published 7/29/64, is as follows: Long Range Target UQ, 66)_____ Status Rate 39. OM #/yr. Yields (Bi#) 98.0% Theory Manufacturing $5.985/cwt Cost Quality 0.40 ppm Thermal Chemical Chlorides (TCC) 36.OM #/yr. only need 26.4 through 1969. 98.5$ of theory through June, 1965. $5.859/owt through June, 1965. Present average 0.50 ppm TCC. New target les3 than 0.15 ppm. Presently targeted quality improvements are: Recommend facilities required to make Aroclor 1242 with a Thermal Chemical Chloride (TCC) of less than 0.15 opm Cl by January 1966 and determine how to consistently ship.P/raiols with a power factor of loss than 5% at 100C and 60 cycles by June 1966. The capacity of Dept. 246 (Aroclor) is sufficient to meet forecasted sales plus 25# through 1969. The capacity of Dept. A-246 (Pyronols) will be increased to meet forecasted sales by up-grading the blending facilities (6/66) and providing storage for TCB, 1260 PPO, and 1254 PPO (1/67). To meet forecasted sales in Dept. B-246 (Pydraul), storage for one of the two product (Pydraul 200 and 280) will be provided by using the present TCB underground storage when it becomes available In 1/67. MOMS 057628 CONFIDENTIAL INFORMATION Thia document la (tie properly of Monsanto Company and the recipient Is responsible for its safekeeping and disposition. It comsina confidential infoimation of Monsanto Company which must not be reproduced, revealed to unauthorized parsons or tent outside the company without proper authorisation. Either retain in secure files or destroy. 91370:1716 Pg. 2 9/17/63 High speed drumming facilities will enable a reduction of 1 man, $10,000/yr. in 1/67. A work force evaluation will be made by 1/67 to determine feasibility of further reductions. D. R. Middleton /Jd HONS 057629 91570:1716(1) Fg. 1 9/17/65 DETAILS Synopsis of Process The Aroclor Process consists of the following steps: Chlorination Batoh chlorination of biphenyl (Biff) with Snlft Oas (contains approximately 86 mole % Cla)at 150C produces crude Aroclor. The by-product Is hydrogen chlorine (H<)1) gas. Blowing Crude Aroclor, from chlorlnators, is blown with air to remove excess HC1 before distillation. Distillation Crude Aroclor which has been air blown Is continuously fed to the stills. These stills are straight-take-over type with no fractionation. Earth Treatment & Filtration The distilled Aroolor Is earth (Attapulgus) treated, filtered, and transferred to storage. Blending & Loading The finished produot from the storage tanks is loaded into cans, drums, tank trailers, and tank cars, or used for making blends (Electrical and Non- Electrlcal). The principal Aroclors which are produced at WOK are 1242, 1248, 1254, and 1260. The last two digits Indicate the weight plus % chlorine contained In the chlorinated biphenyl mixture (Aroclor). QUALITY Aroclor The two main quality measures of Electrical Grade Aroclor are resistivity and stability. Presently the major portion of quality work 1b aimed at improving Aroclor 1242 stability to less than 015 ppm 01 by the Thermal Chemical Chloride (TCC) method. HONS 057630 91370:1716(1) Pg. 2 9/17/&5 The questions to answer concerning Aroclor stability are: 1. What factors effect stability of Aroclor? a) Raw Material Impurities b) Chlorination Techniques cl Distillation Techniques d) Earth Treatment and Filtration 2. What combination of factors are necessary to produce desired quality at the. least cost? . a) Impurity free raw materials b; Chlorination Technique: temperature, feed rate, catalyst, geometry of chlorinator, etc. ' c) Distillation Techniques: stripping and/or rectifying d) Earth Treatment and Filtration e) Chemical Treatment Chlorination: Chlorination techniques (in present WGK Plant Equipment) affect the amount of over and under chlorinated Bibut not necessarily the final stability of the product. The variables which have been measured were: amount of catalyst, method of catalyst addition, chlorinator, chlorination rate, chlorination temperature. The first three were the most significant variables. Distillation: Laboratory distillations, in which low & high boiling fractions (chemical nature of these are not known) were removed from plant crude, produced Aroclor with less than 0.2 ppm TCC. Due to variability of plant crudes the size of the fractions varied from 1-3/6 for low boilers and 10-15% for high boilers. It may or may not be feasible to recycle these fractions to noh-electrlcal Aroclor production. . Future Aroclor Quality Work 1) .Organic Research is presently running continuous distillation tests to determine column design and operating conditions needed to refine present WGK and Anniston Plant crudes to less than 0.15 ppm TCC. Start: 6/65 EDC: 9/30/65 2) Run plant test using revaporlzed CI2. Start: 8/65 EDC: 10/65 HONS 057631 91370:^716(1) Pg. 3 9/17/65 Future Aroclor Quality Work (continued) 3) Investigate Earth Treatment. On two different tests, material earth treated in plant was 0.1 ppm Cl higher than laboratory treated material. Current work at Anniston will be followed. . Start: 9/65 EDC: 10/1/65 By: TSD , PR & D . *1) Preliminary evaluation of Chemical Treatment of ^rude Aroclor to remove unstables. Start: 7/26/65 EDC: 9/30/65 By: PR & D 5) Vapor Phase chlorination for 1242, Start: 10/65 EDC: 12/65 By: TSD 6) By 12/1/66 recommend facilities needed to produce Aroclor 1242 at various TCC levels between 0.5 and 0.1 ppm. , Pyranols The quality of VIOK pyranols (Transformer Blends) must be improved to meet the market's power factor requirements. The target is to consistently ship material with a power factor of less than 5% at 100C and 60 cycles, and have little or no deterlatlon during transit. Future work in this area is as follows: 1) Initiate studies to define the power factor problem. Start: 4th Q of 65 EDC: 6/66 By: TSD 2) From above information take appropriate action. Start: 6/66 EDC: 6/67 By: TSD 3) Studies to determine effect of exposure to various metals is presently underway. EDC: 10/65 HONS 057632 91570:1716(1) Pg. 4 9/17/65 CAPACITY Dept. 2-46 - Aroelor Capacity of Dept. 246 (92# On-Stream Time) Demonstrated I9G6 Forecaat* 1969 Forecast* 1965 Extrapolated Potential Yearly' 27.W 31.6 fl# 29.9n# 56.OW# Monthly 2.3ft# 2.64H# 2.6ft# 3.0ft# Monthly pluo 2.9ft# 5.5 ft# 25# Surge Capacity H.J Day'a forecast dated 5/12/65 multiplied by 1.2 - - The potential capaolty of Dept. 246 is sufficient to meet the needs of future forecasted eales. The department bottlenecks are: Produot Bottleneck 1242 Distillation 1248) 1254) 1260) ' Chlorine Availability The Ole bottleneck oan be relieved by oleanlng or replacing the snlft gas line from the Cla Dept. lfie distillation bottleneck oan be relieved by furnace burner alterations and demonstration of high oapaolty still pump with 3" furnaoe ooll. The only active work In the oapaolty area Is the above demonstration. EDC 11/65. Dept. A-246 - Pyronals Oapaolty of Dept. A-246 1260 PPO 1254 PPO A1#B*B Total for Year Avg. Monthly Avg. Monthly 4 25# Present Capaolty 1966 1969 Debottlenecked 1965 Extrapolated Foreoaft Foreoast Capacity 6.32ft# 6.1 ft# 7*. 5 ft# 4.6lft# 4.3 ft# 4.5 ft#' l.o4ft# 1.15B# 1.15ft# 11.97ft# 11.55ft# 13.15ft# 25.on# 1.0 W#(Max.) 0.96ft# -- 1.20ft# 1.1 ft# 1.5THIS 2. on# MQNS 057633 91370:1716(1) Pg. 5 9/17/65 For flexibility in Dept. A-246 it 1b desirable to have sufficient capacity to meet 25!* surges and sufficient storage for 200,000# of each 1254 and 1260 PPO. The present capacity of A-246 is 1.0M# (when making the 3 blends). No storage is available for these blends. A design premise has been submitted for facilities to increase capacity to 2.0H#/month. ($25, - 30,000). This Increase can't be realized until the following Btorage is available: New 20,000 gallon tank for 1254 PPO New 20,000 gallon tank for 1260 PPO New 20,000 gallon tank for TCB (R/M) Estimated cost of these storage facilities is $105,000. Design premise will be out 9/65. Installed January 1967. Dept. B-246 - Fydrauls A-200 ' Capacity of B-246 ' 1966 " I967 1969 Demonstrated Forecast Forecast Forecast Capacity 4 .7 M# 5.22H# 5.26 W# 6.0 fl# Future Capacity A-280 0.7 M# 1.0 W# 1.5 M Total Yearly Total Monthly 5.4 14# O.45W# 6.22W# 0.52H# 6.75 W# 0.56 H# 6.014# .5014# Meet Forecasted Sales Monthly 4- 25J* 0.56M# 0.65M# 0.70514# - Presently A-200 is the principal blend which is made in the No. 1 Mix Tank. The capacity is limited by sales, because the product is Btored in the Mix Tank. The blending capacity will be increased to at least 1.0M#/month (if Bales are available) as part of the $25-30,000 up-grading Job for A-246. As A-286 sales materialize storage for one of these blends will be needed to attain flexibility. For short range No. 6 underground storage (present TCB) oan be used following installation in New TCB Storage.(January 67). Presently there are no long range (thru 1969) plans for Pydrauls storage. YIELDS The raw, materials for manufacturing Aroclor are Chlorine Snirt Oas and Biphenyl. The Snift Oas usage is not measured, it is calculated. The Biphenyl yields are bb follows: 1964 BijZf Yield 1965 B10 Yield (through June) 1965 Standard Bi(2f Yield 96.57!* 98.5!* 95.5% HONS 057634 91370:1716(1) Pg. 6 9/17/65 The B10 yield losses are as follows: Chlorinator Off-Gas (Collected in Brink and discarded) Still Bottoms Still Vacumm System Unknown TOTAL 0.4# 0.5# 0.1# 0.4# l'.lt# On the average, the Aroclor produced is about 50# Cla, therefore the Cla loss 1b alBO approximately 1,4#. In a 29H# year the yield losses, based on raw mater ial costs, amount to the following: Cla hi.0 TOTAL $4,300 6,400 $10,700 The chlorinated B10 and B10 which 1b collected in the Brink ($3,200/yr.) are presently not recycled because Its effect on stability is not known. The still bottoms are profitably sold as Montar. Presently no extensive 1 future work is planned In this area. HC1 off-gas recovered by Dept. 217 and F-21 Is 83.4# of theory, through June 1965. The loss amounts to about $45,000/year of Muriatic Acid credit. COSTS Dept. 246 - Aroclor - Baals Jan-July 1965 Cost/100# Aroclor Cost for 29ffl#/year Materlal Costs Cla 810 Mlsc. HC1 (Credit) Handling Sub-Total 2.0Q0 3.088 0.015 0.730 0.033 (-) 4.496 . 606,000 896,000 , . 4'550 ( -)211,000 9,560 $1,300,000 MOMS 05763S 91570:1716(1) Pg. 7 9/17/65 COSTS (Cont'd) Direct Conversion Steam Labor Salaries Supplies Laboratory TSD Prod. Process Res. Mech. Expense Others Sub-Total CoBt/100# Aroclor 0,098 0.223 0.042 0.080 0.082 0.069 0.08l 0.337 .097 1.109 Coat for 29M#/yr 28,700 64,600 12,200 23.200 23,800 20,000 23,500 92,800 28.200 $321,000 Indirect Dep FIE Sub-Total 0.122 0.152 0.274 35,400 44,100 $79,500 TOTAL PRODUCT COST 5.879 $1,700,000 In 1966 TSD and Prod. Prooess Res. costs should decrease after answers to quality (stability) problems are found. In the first quarter of 1967 when blending facilities (Dept. A & B-246) are Installed there will be a work force evaluation and possibly a reduction. Extrapolated labor costs for Dept. A & B-246 In 1965 are: Dept. A-246 (Pyranol) $14,850/12,000,000# Dept. B-246 (Pydraul) $14,900/4,370,000# In the first quarter of 1967 high speed durmming facilities should also be Installed (TSD Job No. M5007) which will enable work force reduction of one man ($10,000/year savings). STREAM AND AIR POLLUTION The principal stream pollutants from Dept. 246 are B10, chlorinated B10, and HC1. None of these are presently considered a problem. In the future approximately 150#/day of B10 chlorinated B10 can be removed from the sewers by sending all off-gas brink collections to the toxic dump. The principal air pollutant is HC1 gas. This can be minimized by drowning the blow tank vapors and gases with the existing water Jet. HONS 057t>36 91370:1716(1) Pg. 8 9/17/65 ACKNOWLEDGEMENTS Much of the Information and ideas in this plan were obtained from D. E. Harris V. Brawley, J. J, Luecken, W. G. Kramper, and others. /Jd D. R. Middleton HONS 057637 *tkjry '* PT,''T(W ~;q. CS.'SCPIVS 519 Aroclor: Improve Electrical Grade C,,uaIIty 3229 Aroclor: l:vtall 3" col?. In '* . 2 still furnace 1IST C? CVP.HZNT AID PROPOSED I03S SAvurc-s CAPITAL "vj COMPLETION yjyy.yn^r^s ^>g '"SCtT,*"*CA- * SUCCESS --Sim*rA^ 7ACT0R Protect Market Position ? 6 1/66 10055 (2v?.l.; Increase still capacity None coil to be comratable with new low maintenance still pump V* 10/65 50* 3287 3362 Aroclor: Improve lr,r.'*i:T2 and o.lending ^."llities Capacity (to minimum or 2. Capacity increase needed to meet sales, Possible work force reduction Meet sales in first half of 1965 $25 $30,000 None 2 6/66 9055 1/2 10/65 10055 M50O7 fa UOVid: high $!0,0C0 savings from labor reduction 1 ? 3/67 80* Provide Irv.:capacity to $105,000 k 1/67 . 90* for .125 " '!> mne:- sales, flexibility 0 and TC'3 M503*1 V'M O Aroclo- . -'c noof above !?.! ' ' /! mg dock A.roo - and ,;'2 j :.n Aroclor; Provide exhaust fan for r>rv-"--'.: ng Area Prc'enr, shiur-1' 't delays; s.'.ve $.1,200/jr demurrage '-'p-'cv'' oua':''1. ' ions y.o oof5 ' 'a savings Safety - Pxane inhalation 1/4 7* 50* 1/66 50* O u> LIST OF CURRENT AND PROPOSED JOSS (Cont'd) . -i --.. ?g. 2 9/17/65 rT*TrT>Ti5^ OHISC^VS SAVINGS BENEFITS Pyranols: Investigate high power factor problems . Needed to meet the industries future requirement Aroclor: Increase safety of sSJ.I! but toms dronolns ooeratlcn Safety Pyranols: Determine suitable material for shipment of Transformer Siends * $10-520,000/year customer reimbursement CAPITAL TSD TIT'S TO COMPLETION NAN-MONTHS EDC SUCCESS Ptv.SgAj'' '3, CCMM FACTOR 1/2 1/3 1/66 9055 10/66 90/ : >;. .fcaJSU TcilerirIs Sect!on *nt i.y working on. - `'r f 4- ; Vr . HONS 057639