Document wKNvgY3bkR4q9qok7n4RrvjmJ

MONSANTO CHEMICAL COMPANY ANNISTON, ALABAMA February 14, 1958 REPORT OF PLANT INSPECTION MADE 8.19.58 To: W. R, Canbron Jack Clegorn T. H. Collier D. B. Curry W. J. Dougherty E. L. Dover W. B, Dunlap A. J, Finley H. L. Cray L. E. Hamer B. M. Hathorn R. L. Hedworth R. L, Lumpkin R. B. Mehley J. A. Mullendore R. A. Pelletier H. L. Phillip. J. Harris Powell M. M. Silver *J. H. Starr Beldon Twyaon M. J. Willlams P. W. Wilson B. D. Ward CC: D. B. Hotner C. M. Edelblut J, H. Gould R, C. Sprague C* A. Sweete MONS 035301 MONSANTO CHEMICAL COMPANY ANNISTON, ALABAMA. SAFETY AND HOUSEKEEPING INSPECTION COMMITTEE REPORT - 2-12-58 I. OBJECTIVES; Th objectives of the February Safety end Plantkeeping Committee were as follows: 1. To regenerate "Safety Consciousness" among the Anniston Plant employees. a) By reviewing the six reportable and near -tales accidents we have had since January 1st with employees during the Inspection tdur. b) By asking the employees contacted to name a hazardous procedure they have practiced or observed, 2. To determine employee knowledge of artificial respiration. 3. To observe the stethod used In the plant to handle compressed gases (Ng, COg, etc.). 4. To Inspect the generel housekeeping In the plant. U. RESULTS & RECOMMENDATIONS 1. Safety Consciousness. The reportable and near-mlsa accidents were reviewed with 37 employees. All appeared to be sincerely concerned about the Increase and were very helpful In pointing out practices and/or situations which they considered unsafe. (See section on unsafe practices). The Bound.ttee recommends that supervision continue the review of Anniston accidents with their employees and point out that unless the trend Is stopped, a lost-time accident Is sura to follow. Employees should be requested to analyte each Job, anticipate the hazards, and to take steps to eliminate the hazards or protect themselves. This should be done promptly In regular or special safety meetings. 2. Artificial Respiration Plant knowledge of artificial respiration is very Inadequate. The Committee found only 4 employees, out of 37 contacted, who appeared to heve adequate knowledge of the latest artificial respiration techniques. Two employees heve never received training. The remaining 31 employees felt they needed refresher training. Sixty percent said they were not familiar with the Hallson Lift Method. , MONS 035302 / 2- The Committee strongly recommends that training in artificial respiration be given all plant employees as soon as possible. Recommend training film, practice sessions, and posters. 3. Pea of Compressed Oaa The Committee found eeveral glaring examples of unsafe practices In the use of compressed gases (CO2, No, etc.). Many cylinders mere observed standing on end without being eecurely chained. There were no etandard pressure reducing valves provided for the cylinders end In some cases, the gas was being used without any knowledge of the pressure being delivered to the pipeline or equipment. It is strongly recommended that Supervision take a critical look at the procedures being folloved and take prompt corrective action. Employees should be instructed in the dangers of mishandling compressed gases. 4. Oeneral Recommendations a) Many steam and water leaks were observed. These leaks not only represent a loss In money, but also may Injure people through burns or creating slick surfaces by wetting or Ice formation. Maintenance and Production supervision should be more diligent In their efforts to eliminate leaks. b) More effort la needed throughout the plant tp prevent lea formation on steps and walk-ways. Also some letties were observed In work areas which were a menace. Mott of the Ice formation 'was caused by leaks or the purposeful bleeding of water and steam tracers to prevent freezing. Corrective action . ehould be taken to stop the leaks and change the location of bleeders so that ice Is not formed in critical areas.' c) Some mishandling of gas masks was observed In the Nlran area. The Committee recommends that refresher training be given employees In the care and use of gas masks, and a procedure be developed for the use and Inspection of emergency masks. d) In general, the appearance of the plant was good, it le recommended that a special effort be made between now and March 25th, when Anniston will be host for the Organic Division Plant Manager's Meeting, to bring the plant to a high level of good housekeeping, 5. Unsafe Practices Observed or Related by Employees The following unsafe practices or hazards were observed by the Committee or related by the employees contacted during the Inspection tour. s) Measuring and sampling of Biphenyl storage tanks Is hazardous. It Is nscessary for a man to climb over a handrail and piping then stand on unguarded curvature of tank at sampling nozzle. b) Steam leaks around the benzene storage tank area create a hazard. MONS 035303 -3- c) On* nan fait that It was very hazardous for two nan to carry C02 cylinders up stairwell*. d) Ice on platform and steps was nentloned several tines. e) Mechanical people felt that the present procedure for Issuing clothing to mechanics in the Rlran area should be reviewed. They pointed out that on several occasions clothing had not been available or was dirty and possibly contaminated. They were reluctant to usa gloves which had been dirtied on a previous job by soneone else. f) Several employees felt It was unsafe for Rlran employees to wear their over shoes Into the locker room. They pointed out the possibility of bringing toxic material Into the room and subsequently contaminating men who were walking around barefooted. g) The second floor, Aroclor Department, becomes slick whan It rains In the open windows. h) Several employees mentioned equipment which was hazardous to get to or repair, such as pumps located in tight placet, valves on high lines, ate. They suggested consideration b* given to providing adequate ladders, platforms, mechanical hoists, ate, to reduce the hazards. 1) It was suggested that Rlran safety procedures be reviewed again with mechanical and department employees. j) Employees were observed handling dangerous chesdcals without adequate eye protection. k) Employees have been observed Jumping off the loading platform on the east side of the Biphenyl Department. l) A Lab employee felt that It was unsafe to analyse Rlran samples throughout the . lab at par peasant practice. Be suggested that all samples be run In one specific designated area. m) The method used to feed Mterlal Into the shop built band-saw Is very dangerous. n) The "Ho Smoking" sign over the door at the paint shop Is being violated. An . ash tray containing dgarats butts was found Inside the shop on the table. o) A plant guard stated that some car* leaving the parking lot exit through the . entrance end. in. spicinc monos fiiTlP.H HONS 035304 Shipping Office File cases located on the floor underneath deak at the north wall. should he removed to the vault* k These caaea Maintenance Superintendent's Office The walls and door need cleaning. There Is a lamp cord which should be replaced. Secretary's Office Floor at north wall should be repaired. Printing Room The two-door cabinet needs to be cleaned Inside and stationery should be removed from the top of the various cabinets and tables. Repeat item. Laboratory The floor Is In very poor condition and In need of cleaning. SHOP AREA Shop The general appearance of the shop was good. Carpenter Shop a) There la a steam or hot water heater leaking water Just outside the paint shop door. The water made the concrete floor very slick, b) Several paint buckets were stacked along the south wall - appearance poor. Faint Shop Paint shop In need of general cleaning. 2nd Floor Northeast corner of the print room Is very dirty - needs general clean-up. 3rd floor e) Southwest side cluttered with rolls of wire and stacked desks. In need of general clean-up. b) There Is a hole In the floor near the southwest corner of building. This hole Is covered with an Instrument which creates a stumbling haiard. 8SRVICE BUILDING a) Coats were hung on hooks near the showers In the white locker room. The coata should be hung In lockers. MONS 035305 -3- b) There le e painters platform located on top of lockere In the colored locker rooa. Thle platform ahould be removed. LABOR SHOP General appearance good - aome clean-up la needed around the outalda of the building. MURIATIC ACID AREA a) The area around the coke acrubber and acid atorage tanka la In poor condition. General clean-up needed. BIIMIEMYL a) Ground area on aaat aide of Biphenyl Department In poor condition. Needs clean-up. b) Steam and water leaks should be repaired. c) Patch west wall of meter room whan It rains. room to prevent water collecting In the d) The safety shower outside the hydrogen compressor room will not work. e) Biphenyl lunchroom needs some cleaning. Trash can should be provided In this room for lunch waste paper. f) Biphenyl lab bench area dirty. Meeds general clean-up. g) The pipe rack area outside the Biphenyl pipe shop Is cluttered. Items should be arranged more neatly. h) Remove fan and celling vent from third floor platform. Repeat item. 1) Several small product spills wars observed on the floors throughout the Biphenyl Department. Leaks should be repaired and material cleaned up. AROCLORS a) Floor Is covered In placet with tarry product. Should ba sanded down. t>) Clean off the tops of the hoods located In the ground floor area. c) Clean up Jat platform. There are still parts of Jett scattered around. d) Consideration should be given to replacing the 55-gallon brlck-fllled stoves with standard gat heaters. a) Bote racks should be provided In strategic locatlona. f) There was a.lever-pak lid wired to the forward flow sight glass on the #1 Aroclor still. This lid was used as a wind guard for a gat torch. This make-shift guard should ba replaced by one fabricated In the shop. MQNS 035306 -6- g) Repair steam leak*. BADTOWAX DEPT. a) Extend the Jet exhaust as that condensate doea not drip within the platform area. CHLORIDE PLANT a) Remove CO^ cylinders lying on ground east of the Chlorine storage tank. (These cylinders were left over from a shop job) b) The Chlorine maintenance shop appears to be clean, but the Items stored therein should be arranged In a more orderly fashion, vto-- c) Clean off the top of the Meetinghouse compressor located outside the rectifier room. d) Grinder face shield, etc. should not be stored In ground floor room of rectifier bldg. Repeat Item. ^0-wC. HELPER SHACK Area around welder's shack Is cluttered. Should be tidied up. MB 1. Area south of Rlran In vicinity of water tenk should be graded and seeded. 2. Hose house south of Nlran should be equipped and painted. 3. Metal warning signs should be posted on fence surrounding sub-station southwest of Rlran. A. Cable south of Rlran should be properly stored. DIRAD PLANT 1. Area In vicinity of Incinerator should be policed. 2. Hose racks should be Installed. Hose presently colled on floor. 3. Fire extinguisher locations should be properly marked. 4. M.H. on Thlo Acid .tank not bolted down. 5. Ceneral policing of all operating levels required. Rags, paper, pipe, etc. scattered about. 6. Ice should be removed from grating, pipes, etc. MONS 035307 -7- 7. Sump covers should be replaced behind cubicle*. 8. Roadway west of building scattered with wood, hose, paper, etc. - In very poor shape. 9. Sample bottle* on floor In control room. TSP BUILDING 1. Trash In elevator pit. 2. Light panel wiring on west wall exposed. Door should be put back on. 3. Sliding door on north wall should be removed. 4. Yard north of building should be picked up. BUILDING 41 - OLD BOILER ROW 1. Stove located under Hayes instruments should be relocated to center of building. 2. Floor should be swept. Hlecellaneous piping, etc. scrapped. BOILER ROOM 1. No handle on boiler room doors. 2. Ocneral policing of floor necessary. 3. Fusee should be removed from panel In southeast corner. PROCESS BUILDING HO. 2 1. Temporary wiring should be removed so that starter on east wall southand building can be closed. 2. Junk at foot of stairs tb second level. 3. Junk south of elevator on second level, 4. Loading area shouth of building requires policing. STORAGE AREA EAST OF PROCESS BUILDING NO. 2 1, Entire area requires straightening up. 2. Caps off fire hydrant. HONS 035308 INSPECTION COMMITTEE C. M. Edelblut - Chairman VI. R. Cambron R. E. Sprague (for T. W, Collier) Ben Hard (for H. J. Ingram) Beldon Twymon P. H. Wilson MONS 035309