Document wDx4v3qQw0qRMKOKpND8z1d5B
ROM
GEORGE H. FARRAH ENVIRONMENTAL HEALTH LABORATORY ALCOA. TECHNICAL CENTER
TO
/ L-j. INDUSTRIAL HYGIENISTS
PLAINTIFF'S
EXHIBIT A L-553
April 17, 1972
REi INDUSTRIAL HYGIENE NEWSLETTER - ASBESTOS DUST EXPOSURES
Mr. R. P. Carter's Newsletter dated December 23, 1971, concerning the QSHA emergency standard for asbestos has led to many requests for
advice in determining compliance with the new Federal standards. This
letter attempts to point out the more likely areas of exposure to asbestos dust, general reduction of worker exposures and includes
sampling and analytical methods to determine if you are in compliance with any promulgated 06HA standard referring to asbestos.
The principal asbestos-containing materials of concern (apart from building insulation and pipe covering) are Molten Metal Marinite (Johns-Manvilie), asbestos shorts and insulating block used in smelting cells and furnaces of all types. Marinite constitutes a problem from the point of delivery of s'heet stock, through storage and handling, all
machining operations, removal of used material, to disposal of wastes. Asbestos shorts, as currently used, may present dust problems during transfer and mixing of the dry material in preparation of mortar, and in removal of old linings. According to Mr. H.M. Short, practically all the insulating (back-up) block used in smelting cells and in all types of furnaces contains 8% asbestos. This means that the operations of removing old lining from furnaces and cells, and even the relining, can create asbestos dust exposures. Asbestos is also used in other forms, such as paper and rope, and in a variety of applications - but principally as high temperature gasket. Wherever asbestos is routinely used, and in whatever form, we must take a careful look at exposures, not only of those handling the material, but of other workers in the vicinity. As mentioned in the December 23 Newsletter, this concern applies as well to the demolition of asbestos-covered structures, pipes, etc.
In starting an asbestos dust control program, the first step should be the listing of all forms and applications of asbestos-containing materials. This information should be readily available from the Process Materials List which all plants should have prepared and which they should maintain as current information. Next, all operations involving asbestos should be critically inspected. In many cases, it will not be necessary to collect samples and count fibers to recognize that concentrations are too high. If inspection of the operation shows a visible dust cloud, or if there is a layer of asbestos dust on surrounding surfaces, control measures must be instituted at once. Many of these measures are specified in the Federal Register of Tuesday, December 7, 1971; there are also some useful suggestions in the copies of Insulation Hygiene Progress Reports which were attached to the December 23, 1971, letter.
Most shops in which Marinite is processed have exhaust ducts attached
to lathes, table and bandsaws, routing machines, etc. Power hand tools
are similarly equipped and connected to the exhaust system. Some of
these do a fairly good job of capturing dust, others^are of little
value. To be effective, enclosures must be virtually complete, with
ALCOA
APC 001215
Industrial Hygienists April 17, 1972 Page 2
high capacity exhaust systems. Furthermore, exhaust systems must be connected to collection systems which meet the performance standards set forth in the Federal Register, December 7, 1971, page 23208, Section 1910.93a and pages 23242-23243, Sections 61.23 and 61.24. There should be no visible emissions from discharge of the collection system. This discharge should be to the outside and directed away from any windows that may be opened, to avoid any pos sibility of dust being blown back into the workroom. Where the collector discharge is directed against the side of a building and has resulted in a readily visible brown deposit, collection efficiency may well be questioned. Assistance with your control problems can be obtained from the Pittsburgh Environmental Engineering Division.
The handling of dry asbestos shorts may be avoided by purchase of this material in plastic bags equipped with hose connections which permit wetting of the contents before the bag is opened. Wet-digging of old trough and furnace linings, where this is permissible, will reduce the generation of dust. If wet removal and replacement of lining is done in the open, provis'ion should be made for adequate clean-up, including flushing away of fines, so that dust will not blow about as the work area dries. In all cases, clean-up must be done by means of vacuum cleaners and not by dry sweeping. Asbestos wastes should be collected and disposed of in sealed bags as required by the existing standard.
In removing old furnace and cell linings, wetting the exposed surfaces to minimize dust should be employed wherever practical. Again, the Pittsburgh Environmental Engineering Division should be consulted on the practicality of exhaust from the working area, especially during lining removal.
After installation of all appropriate control measures, even though there is no visible dust, an air sampling program will be necessary to determine whether respiratory protection may be discontinued. If levels of dust are above the standard permitted, the actual levels will establish the type of respiratory protection required.. The emergency standard for asbestos dust published in the Federal Register of December 7, 1971, established the approved method for counting the fibers in a sample. When this level was proposed as a permanent standard in the Federal Register of January 12, 1972, (Attachment #1) some of the details of sampling were also spelled out, along with requirements for warning signs, environmental sampling, and medical examinations. Early in February, NI06H published a criteria document on asbestos dust recommending a still lower fiber count as the standard. The detailed method for sampling, counting and calculating the fiber concentrations which was contained in this document is given in Attachment #2. Attachment #3 is a copy of OSHA Sampling Data Sheet #2 which contains additional helpful information. Regardless of the concentration which is established as the final standard, these sampling and analytical procedures will apply.
APC 001216
Industrial Hygienists April 17, 1972 Page 3
Sampling to determine worker exposures will be the responsibility of
each plant and suitable equipment must be purchased, if it is not
already available. The decision to evaluate samples in-house or to send them to a commercial laboratory will depend upon availability of personnel and equipment, and the volume of work anticipated. While our Environmental Health Laboratory will be equipped to make these evaluations for the Technical Center, the anticipated demand would be too great if we were to offer our services, company-wide.
Collection of samples is most conveniently done with pre-loaded filters and a small, battery powered pump of about 2 liters per minute capacity, such as the following:
Pre-loaded Filters
Millipore Field Monitors, Cat. No. MAWP 037 AO " Price .per carton of 50
(available from Millipore Corp., Bedford, Mass. 01730)
$30.00
Battery Powered Pump
1. MSA Portable Pump Assembly, Model G, Cat. No. 456058 (Requires MSA Battery Charger Assembly, Model G Pump, Cat. No. 456059)
$160.00 $ 40.00
Mine Safety Appliances Co. 201 North Braddock Avenue Pittsburgh, Pa. 15208
or
2. NEI Micronair Personal Air Sampler, Cat. No. 3900-10, complete with Nicad battery and charger
$195.00
National Environmental Instruments, Inc. 1865 Post Road Warwick, R.I. 02888
Counting the fibers collected on the filters requires the use of a microscope equipped for phase contrast illumination, and a good quality microscope lamp, preferably one capable of providing Ktthler illumina tion. To adape a given microscope for this work, the manufacturer should be consulted because the optical parts of different manufacturers may not be interchangeable. A Bausch said Lomb CTA-10 conventional microscope would require these accessories: special condenser, telescope, filters, phase annulus, and objective totaling $344.00. A suitable microscope lamp may cost about $100.00. If a microscope is to be purchased especially for this work, consideration should be given to the American Optical N51MP Series 50 Phase Teaching Microscope with 4X scanning objective, 10X phase and 45X phase objectives, said built-in
APC 001217
Industrial Hygienists April 17, 1972 Page 4
illuminator. It appears to be a satisfactory instrument and sells for $448.00, without carrying case.
Examination of Molten Metal Marinite dust by phase contrast and bv bright field illumination showed little difference since the fibers are stained brown - probably by iron oxide - due to heat treatment vdiich Marinite receives to convert it to the Molten Metal type. This was confirmed by discussion with the Product Manager for Marinite, Johns-Manvilie Corporation, who stated that the only type of asbestos used in Molten Metal Marinite is the brownish amosite. At this time, it appears that exposures to Molten Metal Marinite fibers can be evaluated by bright field counting with a conventional microscope. Therefore, this can be used to get preliminary data on Marinite dust concentrations, until equipment for the standard method required by 06HA is obtained. This is hot the case for other forms of asbestos, which will require phase contrast microscopy at the outset.
Sending samples to commercial laboratories for counting may be advantageous in some cases, but may also present difficulties in locating laboratories qualified to perform this service. Walter C. McCrone Associates, Inc., Chicago, 111., is probably the best known organization in the field of consultative microscopy and is preparing to offer this service at a charge of $25.00 to $30.00 per sample.
Mr. Robert P. Carter has supplied a corrected list for the respirators approved by the Bureau of Mines to replace that attached to his December 23, 1971, letter re "Emergency Standard for Exposure to Asbestos Dust." A copy of this corrected list is Attachment #4.
If after reviewing this letter and all attached materials you have questions or special problems concerning methods of sampling and counting, please contact me.
GEORGE H. FARRAH
GHFrmh
Attachments
cc, no att: Chairmen, Environmental Health Steering Committees
V-^W. Rieke, Pgh. - 2
tSL. V. Cralley/T. B. Bonney, Pgh. - 7
W. B. Garyotis, Pgh. - 2 R. H. Watson, Pgh. - 7 R. B. Kempton, Rea Magnet
APC 001218
DISTRIBUTION
Arkansas Badin Chillicothe Cleveland Cressona Corona Davenport Lafayette Lancaster Lebanon Logans Ferry Marshall Massena Mobile Pt. Comfort Richmond Rockdale Tennessee Tifton Vancouver Vernon Warrick Wenatchee
INDUSTRIAL HYGIENISTS
EHSC CHAIRMEN
J*L. Laudenberg Earle Morgan J. Schachtele L. L. Grubb E.J. Schafer R.H. Allen K.W. Williams L.S. Chambers H.E. Hillstrom R. Andrew W.D. Helmick J. W. Warnock W.S. Barr Albert Steele C.F. Scott R.E. Beachem A,G. Clayton . J.C. Vergho
L.L. H.L. R.L. J.A.
Haisch Chandler Parsons Thompson
J.W. Wells R.C. Hinkle J.J. Thimons L.J. 0Connell N.O. Kraft R.H. Allen D.L. Schaffer J.B. Dolan R.S. Howell R. Andrew J. Hicks L.E. Norris R.W. Knapp R.V. Newsome C.L. Green R.H. Cunneen G.W. Hutton H.W. Brooks H.E. Chandler P. F. Woodward J. R. Jones R.J. Knox J.A. Thompson
e~P1. Ui--' '
j
(: r/c.
APC 001219
Attachment #1
466 PROPOSED RULE MAKING
regulated by this order than from otter (2) Inventories at the beginning and
order plants during the month.
end of the month of the following
DEPARTMENT OF LABOR
Proposal No. 9. Amend I 1036.42(b) (2) products: to read "Other source milk In bulk fluid (I) Fluid milk products; and
Occupational Safely and Health
form exclusive of that specified hi (II) Products listed In 11036.410: ) (1),
Administration
I 1036.41(e)(6)'.
except those received In packaged form
Proposal No. 10. Amend I 1036.43 I%~ from another plant, showing separately
129 CFR Part 19101
terplant movements.
such Inventories in bulk form and In STANDARD FOR EXPOSURE TO
Add In ( 1036.43(c)(3) (1). (U), and
(ill), the words "of bottling grade milk' after the phrase "constitute regular sources of supply".
Proposed by Borden, Inc.: Proposal No. 11. Add to 1 1036.45 a pro vision to read as follows: Subtract from the remaining pounds of skim milk In Class n, the pounds of skim milk In other source milk (exoept that received In the form of a fluid milk product) that is added to, or used to pro duce, any product specified in ( 1036.41
(b). Proposed by Town and Country Dairy,
Garvins Dairy, Sweet Home Dairy, and Halms Modem Dairy:
Proposal No. 12. Amend order No. 36 to provide that the following oountles In the State of Ohio: Belmont, Jefferson,
Harrison, Monroe, and part of Guernsey now In the marketing area; plus the West Virginia counties of Hancock, Brooke. Ohio, and Marshall be included In Zone 1 as defined by the proposal of Milk, Inc. (Proposal No. 1); or alterna tively that the above dairies are to be put
in the present Cleveland-Erle District rather than the Pittsburgh District.
Proposed by the Dairy Division, Con sumer and Marketing Service:
Proposal No. 13. Revise { 1036.11(a) (1) to read as follows:
packaged form;
*
Proposal No. 16. Revise 11036.41(c) (6) (vll) to read as follows:
6 1036.41 Quaff of utilization.
(c)
i
(6>
'
(vll) Less 1.5 percent of the quantity of
bulk fluid milk products and bulk cream
transferred to other plants which!does
not exceed such quantity to which! per
centages are applied in subdivisions (1),
til), (lv), (v) and <vl> of this subpara
graph;
Proposal No. 17. Make whatever
changes are necessary In the order to
eliminate the possibility of a handler be
ing charged under the order at the Class
I price for milk that already has been
classified and priced as Class I milk un
der a Federal order.
Proposal No. It. Reposition, for clari
fication of the order, the provisions which
establish that the Class I price for other
source milk when adjusted for location
of the shipping plant, shall not be less
than the Class in price.
'
Proposal No. 19. Make whatever
changes are necessary In the order to
ASBESTOS DUST
Notice of Proposed Rule Making
Section 6(0 of the WUllams-Stelger
Occupational Safety and Health Act of
1970 (84 Stat. 1596 ; 29 UjS.C. 655) pro
vides that upon the publication of an
emergency temporary standard In the
Federal Register the Secretary of Labor
shall
a rule making proceed
ing In accordance with section 6(b)
erf the Act, and that the emergency
standard as published shall also serve
as a proponed rule for the proceeding. An
emergency temporary standard concern
ing exposure to asbestos dust was pub
lished In the Fedesal Rxcistex on De
cember 7, 1971 (36 FJL 23207). Accord
ingly, pursuant to section 6 (b) and (c)
of the Wflliams-Stelger Occupational
Safety and Health Act of 1970 (84 Stat.
1593. 1596; 29 UB.C. 655). 29 CFR
1910.4, and Secretary of Labor's Order
No. 12-71 (36 Fit. 8754). It la hereby
proposed to amend 29 CFR Part 1910 as
set forth below. The proposals Include
the emergency temporary standard and
additional proposed rules on subsidiary
issues.
Interested persons are invited to sub
mit, both orally and In writing, data,
views, and arguments concerning these
1036.11 Pool plant.
provide for a uniform "equivalent price" proposals.
section to read as follows:
Written data, views, and arguments
may be mailed to the Office of Safety and
(a) A distributing plant that has:
8 1036.54 Equivalent price.
Health Standards, Room 305. 400 First
(1) Route disposition except filled If for any reason a price or pricing Street NW, Washington. DC 20210. with
milk, during the month of not less than component required for this part for in 30 days after the publication of this
50 percent (40 percent for each month of April through August) of the total re ceipts of fluid milk products, except filled milk, that are approved by a duly constituted health authority for fluid
computing class prices or for other pur poses Is not available in the manner de scribed In this part, the market admin istrator shall use a price or pricing com ponent determined by the Secretary to be equivalent to the price or pricing com
notice in the Federal Rxcistex. The data, views, and arguments will be available
for public inspection and copying at the Office of Safety and Health Standards, except as to matters the disclosure of which is prohibited by law.
consumption and that are physically re ponent that Is required.
Oral data, views, and arguments will
ceived at such plant or diverted as pro ducer milk pursuant to ( 1036.16 to a supply plant qualified under paragraph (b) or (c) of this section or a nonpool plant; and
Proposal No. 14. Review the provisions of { 1036.11(c) to determine whether
Proposal No. 20. Make such changes as may be necessary to make the entire marketing agreement and the order con form with any amendments thereto that may result from this hearing.
Copies of this notice of hearing and the
order may be procured from the Market
Administrator, 7503 Brookpark Road, Cleveland, OH 44129 or from the Hear
be received by Hearing Examiner Arthur Goldberg, at a bearing beginning at 10
a.m. on March 14. 1972. in Conference Room B, Departmental Auditorium, 14th Street and Constitution Avenue NW, Washington. DC. Persons desiring to ap pear at the hearing must file with the Office of Safety and Health Standards a
notice of Intention to appear, no later than March 3. 1972. The notice must
they should apply only to plants primar ing Clerk, Room 112-A, Administration state the name and address of the per
ily engaged In the transfer of minr to Building, UJ3. Department of Agricul son to appear, the capacity In which he
distributing plants qualified under para graph (a) of this section.
ture, Washington. D.C. 20250 or may be there Inspected.
will appear, and the approximate amount of time required for his presentation. The notice must also include, or be ac
Proposal No. 15. Revise ( 1036.30(a) (2) Signed at Washington. D.C, on Janu companied by. a statement of the posi
to read as follows:
ary 7, 1972.
tion to be taken with regard to the pro
8 1036.30 Report of receipts and stilialion.
(a)
John C. Blum.
Depittp Administrator, Regulators Programs.
[FB Doe. 72-468 Filed 1-11-72:8:49 tm]
posed rules.
The oral proceedings shall be reported verbatim, and transcripts shall be avail able for inspection to any Interested per son on such conditions as the presiding
BOOM. UeiSJO, VOL 37, MO. 7--WIONKOAT, .JANUARY 12, 1972
APC 001220
PROPOSED RULE MAKING
467
hearing examiner may prescribe. The hearing examiner shall regulate the
Subdue*
paragraph are not feasible or do not re Mppcf Mf/M* duce the concentration of asbestos dust
course of the oral proceedings, dispose of procedural requests, objections, and
Amorphous* including natural diatomecoous earth.--............
similar matters, regulate the conduct of
below the limits prescribed In paragraph
20
SOmg/lP
(a) of this section, the employer shall require the use of respiratory protective
those present at the hearing by appro*
%BlOi devices. The selection of respiratory pro
prlate means, and shall exclude to the extent practicable Irrelevant. Immaterial, and unduly repetitious data or argu ments. The hearing examiner shall have discretion to keep the record of the hear ing open for a reasonable, stated time to receive written recommendations, and
BUJcaUft (lest than 1% cry* tallne riba): Mica.................................... Soapstone............................ Talc................................... Portland cement..... Qraphit* (natural)................. Coat dust (respirable traction lass than 0% 81(h)..
tective devices shall be limited to those
specified in paragraph (c) of this section.
20 20 20
(11) The employer shall require that each employee test his respiratory pro
B0 U
tective device before each use in order to Insure a proper fit according to the
2-4rag/M* manufacturer's instructions. The em
additional data, views, and arguments from any person who has participated in the oral proceeding. Upon completion of the oral proceedings, the transcript
For more than 6% 8IO*. Inert or Nuisance Dust:
Respirable fraction........
..
lOmg/M1 ployer shall further provide for effective training or supervision of employees In
%OH-2 the testing of respiratory protective de
15 Smg/M* vices for fit before their use.
thereof, together with written submis
Total dust............................
50 lAmg/M* (c) Allowable respirators. (1) When
sions on the proposed rules, exhibits filed
the 8-hour time-weighted average con
during the hearing, and any posthearing data, views, arguments, and recommen
Non: Conversion factore-
mppcfXSB
particles per coble mater
particles per c.c.
centration of asbestos dust Is projected to exceed 5 fibers longer than 5 microns
dations shall be certified by the hearing i Militant of particles per cable foot of air, based on per milliliter, but not to exceed 25 such
examiner to the Assistant Secretary of Labor for Occupational Safety and Health for his decision. The Assistant Secretary may adopt the proposals with or without changes, or determine not to
Implnger samples counted by Ugbt*fleld technics. * The percentage of crystalline silica to tbe formula
b the amount determined from air-borne samples, except in those instances in which other methods navebeen shown to bo applicable.
i As determined by tbe membrane filter method at 430 X phase contrast magnification.
fibers, and when a concentration over a period of 15 minutes exceeds 10 fibers longer than 5 microns per milliliter, but
does not exceed 50 such fibers, a re usable or single use filter type respira
Issue a rule. Under the authority of section 6(1)) (1)
Both concentration and percent quarts for the application of tfab limit an to be determined from the fraction passing a riaeolector with tbe following
tor, operating with negative pressure during the Inhalation phase of breath
and section 7(b) of the Act, the Assist characteristics:
ing. approved by the Uj8. Bureau ol
ant Secretary of Labor for Occupational
Mines under the provisions of 30 CFR
Safety and Health will request the recommendations of an advisory com
Aerodynamic diameter (unit density sphere)
Percent paring elector
Part 14 (Bureau of Mines Schedule 21B). shall be used.
mittee with regard to the proposed rules.
(2) When the 8-hour time-weighted
The committee will be provided with copies of these proposals, together with all pertinent factual information which is, or may become, available to the As
2 2.5 3.1 5.0 10
00 75 50
average concentration of asbestos dust is projected to exceed 25 fibers longer
25 0
than 5 microns per milliliter but not to exceed 250 such fibers, and when a con
sistant Secretary, including any infor
centration over a period of 15 minutes
mation submitted by the National Insti tute for Occupational Safety and
Tbe measurements under this note refer to the use of an AEC Instrument. If tbe respirable fraction of coal dust Is determined with a MRS the figure corresponding
exceeds 50 fibers longer than 5 microns per milliliter but does not exceed 500
Health. The advisory committee will be to that of 2.4 Mg/M* in tbe table for ooal dust Is 4.6 Mg/M* such fibers, a powered filter' positive
asked to submit to the Assistant Secre tary written recommendations regarding
these proposed rules within 45 days after
2. A new i 1910.93a is proposed to be 'added to Part 1910, reading as follows:
pressure respirator approved by the U.8. Bureau of Mines under the provisions of 30 CFR Part 14 (Bureau of Mines Sched
the publication of this notice. The g 1910.93a Aabealo* dust.
ule 21B) shall be used.
recommendations will be available for (a) 8-hour time-weighted average. (3) When the 8-hour time-weighted
public Inspection and copying. No other advisory committee will be consulted with regard to these proposed rules.
Part 1910 of Title 29 of the Code of Federal Regulations is proposed to be amended as follows:
1910.93 [Amended]
1. Table G-3 In { 1910.93 (36 FJt. 15104. August 13, 1971) Is proposed to be amended by deleting the following:
Asbestos--12 fibers per milliliter greater than S microns in length or * * * 2 Mppcf.
TremoJtte 6 Mppcf.
If so amended. Table 0-3 would read as follows:
Ta1.z 0-3--Mineral Dusts
The 8-hour time-weighted average air borne concentration of asbestos dust to which employees are exposed shall not exceed 5 fibers longer than 5 microns per milliliter, as determined by the mem
brane filter method at 400-450 x (mag
nification) (4 millimeter objective) phase contrast Illumination. Concentra tions above 5 fibers per milliliter, but not
to exceed 10 fibers per milliliter, may be permitted up to a total of 15 minutes in an hour, but for not more than 5 hours in an 8-hour day.
(b) Methods of compliance--(1) Engineering methods. Engineering methods, such as, but not limited to, en closure, vacuum sweeping, and local ex
haust ventilation, shall be used to meet the exposure limits prescribed In para
average concentration of asbestos dust is projected to exceed 250 fibers longer than 5 microns per milliliter a type "C" positive pressure supplied-alr respirator approved by the U.S. Bureau of Mines under the provisions of 30 CFR Fart 12 (Bureau of Mines Schedule 19B) shall be used.
(4) The employer shall establish a respirator program in accordance with the requirements of American National Standard Practice for Respiratory Pro tection Z88.2--1969.
(5) The respirators provided each em ployee shall be properly inspected, cleaned, repaired, and stored.
(d) Particular operations and prod ucts. (1) When an employer has employ ees who are exposed to asbestos dust re
Substance
Mppcf
Mj/JP
graph (a) of this section. Where such sulting from the operations or the use engineering methods are not feasible, or of tools described in the remaining sub-
Silica: Crystalline: Quarts (respirable)
do not reduce the concentrations below paragraphs of this paragraph (d), the the limits prescribed In paragraph (a) employer shall comply with the require 260* lOmg/M1 of this section, respiratory protective de ments of this paragraph. The require
Quarts (total dust)
%810i+2 vices shall be provided and used In ac ments of this paragraph shall apply at ................. mg/M cordance with subparagraph (2) of this all times, and. In addition, the require
Cristoballte: TJse H the Talus calculated from tbs count or mam formula* for
%8lOf+2 paragraph.
ments of paragraph (b> of this section
(2) Other methods. (1) When Hie may also apply, according to the terms
limits of exposure to asbestos dust pre thereof.
quarts. Tndymlte: Use H tbs rains
calculated tram the for* zuulaa for quarter
scribed in paragraph (a) of this section (2) All hand- or power-operated tools are exceeded, and engineering controls which produce asbestos dust such as, but required by subparagraph (1) of this not limited to, saws, scorers, abrasive
FEDERAL REGISTER, VOL 37, NO. 7--WEDNESDAY, JANUARY 12, 1972
APC 001221
468 PROPOSED RULE MAKING
wheels, and drills, shall be provided with local exhaust ventilation and dust col* lectors in accordance with the American National Standard Fundamentals Gov erning the Design and Operation of Lo cal Exhaust Systems; ANSI Z9.2--1071.
(3) Employees exposed to the spray ing of asbestos, to the demolition of pipes, structures, or equipment covered or Insulated with asbestos, or to the demolition of insulating strippings, shall be provided with respiratory protective devices in accordance with paragraph (c> (3) of this section.
(4) Asbestos cement, mortar, coatings,
grout, and plaster shall be mixed in
closed bags or other closed containers. (5) Asbestos waste and scrap shall be
collected and disposed of in sealed bags or other closed containers.
(6) Accumulation of asbestos dust
shall be removed, as soon as practicable,
and only by vacuum cleaners.
<e) Warning signs--il> Posting. Warning signs shall be provided and displayed at each location where asbestos dust hazards are present. Signs shall be posted at least 50 feet In each direction from the location where the hazard Is present, and at intervals of not more than 100 feet along each edge of the area where the hazard is present.
(2) Sign specifications. The warning signs shall conform to the requirements for 20" x 14" vertical format signs speci fied In 9 1910.145(d) (2), and to this par agraph. The signs shall display the fol lowing legend in the white panel, with letter sizes and styles of a visibility at least equal to that specified in the nota tion In the following column to the right:
Legend: Asbestos _______
Dust Hazard____
Follow theae____________ Safety and Health
Rules.
1. Avoid breathing dust.
2. Wear your respirator.
S. Do not remain in area unless your work
Notation 1" Sans Serif
Gothic or Block. *,' Sans Serif Gothic or Block. Vi Oothlc
% Bans Serif
Gothic or Block %" Gothic.
>4' ` Oothlc
Vi" Oothlc.
requires It. Asbestos dust may
cause asbeetosta, a severe lung disease, and Is Implicated in the development of certain cancers. Con trol of exposure to asbestos dust helps protect against these
14 point Oothlc.
(3) Spacing. Spacing between lines shall be at least equal to the height of the upper of any two lines, except that the spacing between "Following these" and "Safety and Health Rules" shall be at least
(f) Monitoring--(1) Personal. Em ployees engaged In the particular opera tions or using the particular tools speci fied In paragraph (d) of this section, or exposed to concentrations of asbestos
dust in excess of the limits specified In paragraph (c) (3) of this section shall be monitored In accordance with this paragraph.
(I) Method. Dust samples shall be col lected from within the normal breathing zone of the employees in their normal working posture Employees wearing res piratory protective devices shall have the sample taken from a point located on the exterior of the respirator facepiece.
(II) Procedure. The sampling proce dure shall be such as to permit the de terminations required by paragraph (a) of this section.
(ill) Sampling duration. The sampling duration shall be for a period of not less than 15 consecutive minutes.
(lv i Sampling frequency Sampling
periods shall be of such number and pattern as to represent accurately the exposure of the employees over their
working period. i2> Environmental. Environmental
monitoring shall be conducted in all
areas In Which employees are exposed to concentrations of asbestos dust in excess of the limits specified in paragraph (a) of this section
(1) Method. Asbestos dust samples shall be collected from areas which are representative of the concentration of airborne asbestos dust which may reach the breathing zone of exposed employees.
(ii) Procedure Sampling procedure
shall be such as to permit the determina tions required by paragraph 'a> of this section.
fiiii Sampling duration. Sampling du
ration shall be for a period of not less than 15 consecutive minutes.
(iv) Sampling frequency. Sampling periods shall be of such number and pattern as to represent accurately the exposure of the employees over their working period.
(g) Medical examinations. The em
ployer shall provide, or make available at his cost, appropriate medical exami nations on a periodic basis to any em ployee who is exposed to asbestos dust in excess of the limits specified in para graph (a) of this section.
<h) Records. 1> Every employer shall maintain records of the personal and environmental monitoring, and of the medical examinations, required by para graphs (f) and (g) of this section. Such records shall be maintained for at least 20 years.
(2> Hie records of monitoring shall be made available for Inspection and copying to the Secretary of Labor and to his designated representatives.
(3) The records of medical examina tions shall be made available only to the Secretary of Labor, to the Secretary of
Health, Education and Welfare, to desig nated representatives of either of them, and. at the request of the employee or former employee examined, to his physician.
3. A new i 1910.19 is proposed to be added to Subpart B, reading as follows:
S 1910.19 Asbestos dust.
Section 1910.93a shall apply to the ex posure of every employee to asbestos dust
In every employment and place of em ployment covered by 11910.12, 1910.13, 1910.14. 1910.15. or 1910.16 of this Sub part B. In lieu of any different standard on exposure to asbestos dust which would otherwise be applicable by virtue of any of those sections
(Sec. 6. 84 Stat. 1693. 2S DS C 888. 39 CFR 1910.4: Secretary of bailor's Order No. 13-71. SSPJt.8784)
Signed at Washington D.C.. this 6th day of January 1972.
Q C Guznthxx, Assistant Secretary of Labor.
|FRD<w 73-403 Filed 1-11 73:8:48 am|
DEPARTMENT OF HEALTH, EDUCATION, AND WELFARE
Food and Drug Administration
[ 21 CFR Part 19 1
CERTAIN CHEESES
Proposed Identity Standards Regarding Labeling Requirements
Notice is given that a petition has been filed by the National Cheese Institute. Inc., 110 North Franklin Street, Chicago. HI. 60606. proposing that Identity stand ards for certain specified cheeses be amended to require that ill the full name of the food appear on the principal display panel of the label in type of uni form size, styIp. and color 2> wherever any word or statement emphaslring the name of any ingredient appears on the label (other than in circumstances de scribed below so conspicuously as to t: easily seen under customary conditions of purchase, the full name of the food lmmedlatelv and conspicuously precedes or follows such word or statement In type of at least the same size as the type of such word or statement and (3) op tional ingredients be listed conspicuously, either on the principal display panel of the label or on a single appropriate in formation panel in accordance with specifications that are consistent with similar specifications for many other food products
Accordingly ,t is proposed that Part I9beamendea
1 In 9 19 750ifi by revising subpara graph 16) and adding subparagraphs (7> and (8). as follows-
19.750 Pasteurized process cheese: identity: label statement of optional ingredients.
(6) The full name of the food shall appear an the principal display panel of the label In type of uniform size, style, and color
(7) Wherever any word or statement emphasizing the name of any Ingredient appears on the label (other than as speci fied in subparagraph i8> of this, para graph) so conspicuously as to be easily seen under customary conditions of pur chase, the full name of the food shall
FEDEEAl REGISTER, VOL 37, NO. 7--WEDNESDAY, JANUARY 13, 1972
APC 001222
MEASUREMENT of-ASBESTOS FIBERS
Attachment #2
The sample should be collected on a 37-nillimetcr Millipore type AA*
filter mounted in an open-face filter holder.. The holder should be
fastened to the worker's lapel and air drawn through the filter by
means of a battery-powered personal sampler pump similar to those
approved by NIOSH under the provisions of 30 CFR 74. The filters are
contained in plastic filter holders and are supported on pads which
/also aid in controlling the distribution of air through the filter.
To yield a more uniform sample deposit, the filter-holder face-caps
should be removed. Sampling flow rates from 1.0 liter per minute (1pm)
up to the maximum flow rate of the personal sampler, pump (usually not
over 2.5 1pm) and sampling time from 15 minutes to eight hours are
acceptable provided the following restraints are considered:
(a) In order to obtain an accurate estimate cf the number of
fibers the statistical error resulting from the random
distribution of the fibers must be kept to an acceptably
low level. Since fiber counts follow a Poisson distribu
tion, a count of 100 fibers in a sample would have a
standard deviation of 1U0 or 10 fibers or + 10%. Thus
the 95% confidence limits would be approximately 2 standard
deviations or + 20%. Since the 37 mm filter has an effec-
2
tive collecting area of 855 mm and the projected field area of the Porton reticle is 0.005 mm2 , each field rep
resents 1/171000 of the sample. Based on this ratio the
following number of fields must be counted to measure the
various limits in various sampling times: .
'
Mention of commercial products does not constitute endorsement by
the Public Health Service or U. S. Department of Health, Education . and Welfare.
VI1I-4
APC 001223
Sampling Time Minutes
10 15 30 90 90 240 240 480
Flow Rate 1pm
2 2 2 1 2 1 2 1
Number of Fields for 100 Fibers 0.2 fibers/ml 2.0 fibers/ml 10 fibers/ml
4350 2860 1430 1000
500 260 180 180
435 286 143 100
50 26 18 18
91 58
29 20 10
7 4 4
00 Do not count a field containing over 20 fibers because In addition to the fibers being counted, there are also
present a number of grains, which interfere with the accuracy of the coqnt.
Based on these restraints, l.e., number of fields to be counted and maximum number of fibers per field, acceptable sampling parameters for the various limits are underlined in the above table.
The following conclusions may be drawn from this analysis: (1) The short-term limit should be for a period of at least IS minutes and preferably 30 minutes. (2) The 2.0 fiber/cc limit may be evaluated over periods of from 90 to 480 minutes.
As many fields as required to yield at least 100 fibers should be counted. In general the minimum number of fields should be 20 and the maximum 100. Mounting Sample
The mounting medium used in this method is prepared by dissolving -0.05 g of membrane filter per ml of 1:1 solution of dimethyl phthalate
VIII-5
APC 001224
>
and diethyl oxalate. The index of refraction of the medium thus prepared
is ND = 1.47.
To prepare a sample for microscopic examination, a drop of the
mounting medium is placed on a freshly cleaned, standard (25 mm X 75 mm),
microscopic slide. A wedge-shaped piece with arc length of about 1 cm is
excised from the filter with a scalpel and forceps and placed dust-side-up
on the drop of mounting solution. A No. 1-1/2 coverslip, carefully cleaned
( ' '? .
with lens tissue, is placed over the filter wedge. Slight pressure on
the coverslip achieves contact between it and the mounting medium. The
ample may be examined as soon as the mount is transparent. The optical
homogeneity of the resulting mount is nearly perfect, with only a slight
background granularity under phase contrast, which disappears within
one day. The sample should be counted within two days after mounting.
Evaluation
'
The filter samples mounted in the manner previously described are
evaluated in terms of the concentration of asbestos fibers greater
than 5 m in length. A microscope equipped with phase-contrast optics
sad a 4-mm 'Tiigh-dry" achromatic objective is suitable for this deter
mination. 10X eyepieces, one of which contains a Porton or other
suitable reticle at the level-of the field-limiting diaphragm, should
he used. The left half of the Porton reticle field serves to define
the counting area of the field. Twenty fields located at random on the
ample are counted and total asbestos fibers longer than 5 um are
recorded. Any particle having an aspect ratio of three or greater is considered a fiber.
^ VXII-6-
APC 001225
The following formulae are used to determine the number of fibers/nl:
(1) Filter area (mm2) Field area (mn^)
K
(2) Average net count X K fibers/ml Air volume -sampled (ml)
For example, assume the following: area of the filter used was . 855 mm^ counting area of one field under the Porton reticle was 0.005 mm2
average net count per field of 20 fields was 10 fibers; and sample was
l
collected at 2 liters per minute for 90 minutes: Then:
855mm2 - 171,000 (K) 0.005 mm2
10 fibers x 171,000 9.5 fibers/ml 2,000 ml/min x 90 min
Calibration of Personal Sampler
The accuracy of an analysis can be no greater than the accuracy of the
volume of air which is measured. Therefore, the accurate calibration of a sampling device is essential to the correct interpretation of an instru
ment's indication. The frequency of calibration is somewhat dependent on the use, care, and handling to which the pump is subjected. Pumps should be calibrated if they have been subjected to misuse or if they have just been repaired or received from a manufacturer. If hard usage is given the instrument, more frequent calibration may be necessary.
Ordinarily, pumps should be calibrated in the laboratory both before they are used in the field and after they have been used to collect a large number of field samples. The accuracy of calibration is dependent on the type of instrument used as a reference. The choice of calibration instrument will depend largely upon where the calibration is to be ..performed. For laboratory testing, a 1-liter burette or wef test meter should be used. In the field, a rotameter is the most convenient
VIII-7
APC 001226
Instrument used. The actual set-up will be the same for all of these Instruments. The calibration Instrument will be connected in sequence to the filter unit which will be followed by the personal sampler pump. In this way, the calibration instrument will be at atmospheric pressure. , Connections between units can be made using the same type of tubing used in the personal sampling unit. Each pump must be calibrated separately for each type of filter used,' if, for example, it has been decided to use a filter with a different pore size. The burette should be set up
*> ,
so that the flow is toward the narrow end of the unit. Care must be exercised in the assembly procedure to insure adequate
seals at the joints and that the length of connecting tubing be kept at a minimum. Calibration should be done under the same conditions of pressure, temperature and density as will be encountered. The rotameter should be used only in the field as a check if the diaphragm or piston pumps are not equipped with pulsation dampeners. The pulsating flow resulting from these type pumps causes the rotameter to give results which are not as accurate as that obtained with a burette or wet-test meter. Calibration can be accomplished with any of the other standard calibrating instruments, such as spirometer, Marriott's bottle, or dr.gas meter. The burette and wet-test meter were selected because of their accuracy,, availability, and ease of operation.
Method based on a modification of the mejnbrane filter method described by Edwards & Lynch ''The Measurement of exposure to Airborne Mineral Fibers." Presented at the
American Ind. Hyg. Conference, Denver 1969.
x.* v."" *- *; *** .
VTII-8
APC 001227
Attachment #3
1 8330 OSHA SAMPLING DATA SHEETS FOR FIVE TOXIC SUBSTANCES RELEASED
Back reference!: f 1071; 6647.93; 6647.93a.
The Occupational Safety and Health Administration has released sampling data sheets for the five toxic sub stances on which its "Target Health Hazards" program will focus. The data sheets cover sampling equip ment and procedures for carbon mon oxide, asbestos, crystalline silica, lead and its inorganic compounds (except lead arsenate), and raw cotton dust. Criteria for violations of employee exposure to excessive concentrations of each substance are also described.
The sampling data sheets are repro duced below.
8-liour time-weighted average*: 5 fibers per milliliter greater than 5 microns in length. Excursion limit*: 10 fibers per milliliter, up to 15 minutes in an hour for up to 5 hours per 8-hour day. Unprotected or improperly protected worker exposures
Analytical Method: Fibers counted at 400-450 magnification, using phase contrast illumination, with sample mounted in high-viscosity solution of membrane filter material.
Sampling Equipment:
Personal sampling pump plus Millipore type AA filter (37mm, 0.8 , pore size). Face cap is removed and filter used open face during sampling. Sampling rate: 21/m.
Sample Size:
Minimum period of 15 minutes for evalua tion of excursion limit. Several samples of up to 4 hours for evaluation of 8-hour average. Samples with a visible deposit may be too heavy to count. Compare with a clean filter. Heavy concentrations of visible dust in the air (100 to 500 fibers/ml) may require short sampling periods of only 5 minutes, or less.
Blanks:
With each batch of samples submit two fil ters which are subjected to exactly the same handling as for the samples except that no air is drawn through them. Label these as blanks.
Shipping:
The cassettes in which the samples are col lected should be shipped in a suitable con tainer, designed to prevent damage in transit.
Imminent Danger Situations: Generally not applicable.
OSHA SAMPLING DATA SHEET #2
Substance: Asbestos.
Standard: 29 CFR 19I0.93a(a) of December 7. 1971
1 8330
Serious Violation: 5.1 or more fibers per ml, greater than 5 . in length, for an unprotected or improperly protected worker, for an 8-hour timeweighted average, except for certain proven excursions as noted in the emergency stand ard, which may raise the 8-hour timeweighted average to 5.8 fibers per mL
Nonscrious Violation: Not applicable.
De Minimis Violation: Not applicable.
1972, Commerce Clearing House, Inc.
APC 001228