Document wDwVVZdkG5zbxg6Owkd4wnaxJ

RAPCQ AUTOMOTIVE SALES, INC. 2100 NORTH WOODWARD, SUITE 315 BLOOMFIELD HILLS, MICHIGAN 4QD13 TQ j Chardon Rubber Co. Chardon, Ohio Attn: BobGuy " February 29, 1984 DATE Fisher Specs. HT * __ Attached for your review are the latest Fisher Body Specs. FBMS 2-8 and 1-30 re: PVC extrusions and moldings. Thank you, - cc: D. W, Sullivan and Specs.,,,cc: R. Zndaraic & 2-8 FBMS /' BY Roger Bruce HI IP The Oiiw.^n Boifd Inc,. ti 270bOV 71213 instructions TO StNOC?' IWSTBUCT IONS TO ReCCIVLR: CHARDO 00579 BFG TECHNICAL DOCUMENT AUG 0 3 1982 THE BF GOODRICH COMPANY CHEMICAL GROUP REPORT 1-------r_...... ....................... AA .UUTTtr-CGRW A. | S, PAZUR ---------------t1. .CC4JICM ALTC - ---------- B/41S , 1 Cl. A ' F , ---------------- 7-30-B2 . ........... ......... II I ........... ' 0O<", (JbO0uuKv, Rf!*;f*F. fpFf'f"r,vfH. i'i LI'. k 111-50-141 rko'.i' a ral> bv J. SIMMONS LOG A T ION CLEVELAND P Z ,,< A C 1 o 3791 ,'i K '7 'A FJ C , i. k A l___ _ N iJ . TfWj *'b 'S'if k J C T - CHARDON RUBBER - H^S TESTING OF FORD BODY SIDE MOLDING ...I ,i 11 .... . ....------- --g : Introduction: Chardon Rubber submitted samples of the Ford slider window profile for H^S sulfide stain testing of the Geon 83463 Trans 002 topcoat. L Cone!usion: The profile exhibited no change when tested for sulfide staining, and therefore passes the Ford requirement. Future Work: No further work is planned. Results and Discussion: Profile sections ware tested to Ford Test Method FLTM AN2-1 "Resistance of Plastic Materials to Hydrogen Sulfide Staining," as specified in Ford Material Specification ESB-M4D284-C. The test specifies a minimum rating of 5 (no change) on the AATCC Chart for color change after exposure. The profile showed no detectable color change, and therefore, passes the require ment. | ! j ASP:fl cc: G. A. Small P.F.V. Lloyd F. C. DeWolf R. J. Meyer/Int'l. CTF - ALTC ,;B. Wadey/P. J. Weaver ' s. Washko /C-t^osS A/ `I A."S. Pazur (WT'Mhi'j. IN J.A. CHARDO 00580 373 Washington Si-reef Chordon. Ohto 44024 (216) 285-2161 June 2, 1983 Mylar Locking Strip Information 8 Cost Considerations Mylar supplier contact Dorrie Process, Norwalk, Conn. 06852 Warren Hicks - 203-846-2087 Mylar Type - V-3060H 1 mil PVC top coated, 1 mil metalized mylar 6 mil "rigid" PVC Mylar Cost - $4.06/54" yd. (5/1/83], 333 ft. yield/yd. when slit .470 wide allowing 3% slitter scrap. Mylar Slitting Supplier -Euclid Spiral Paper Tube Co., Apple Creek, Ohio 44606 contact - Len Buckner 216-698-4711 slitting cost - $. 25/lb + 25.50 set up gen'l info. - mylar is to slit .470" wide in rolls as long as possible to 3,000 ft. Processing information: Line to run at 25'/min. net yield. Scrap rate approximated at 20% Part length (finished) to be: Ram - 143" +1/4 -3/8 Ranger - 118" +1/4" "Parts are to annealed for 1 hr. @ 212 Cut length on extrusion line to allow for shrinkage of approximately 5% when annealed. Parts are to be packaged in returnable containers. Technical assistance for processing is available from: Prototype Extrusions Rotterdam, N.Y. 12303 Contact: Rod Bakos 518-372-0404 Compounds to be used are: Chardon Rubber Co. - 609140 Black B.F. Goodrich - 86195 Trans 001 clear This information is to be updated and additional information added as necessary. CHARDO 00581