Document wDwVVZdkG5zbxg6Owkd4wnaxJ
RAPCQ AUTOMOTIVE SALES, INC.
2100 NORTH WOODWARD, SUITE 315 BLOOMFIELD HILLS, MICHIGAN 4QD13
TQ j
Chardon Rubber Co. Chardon, Ohio Attn: BobGuy
"
February 29, 1984
DATE
Fisher Specs.
HT *
__
Attached for your review are the latest Fisher Body Specs. FBMS 2-8 and 1-30 re: PVC extrusions and moldings.
Thank you,
-
cc: D. W, Sullivan and Specs.,,,cc: R. Zndaraic & 2-8 FBMS /'
BY
Roger Bruce
HI IP The Oiiw.^n Boifd Inc,. ti 270bOV
71213
instructions TO StNOC?'
IWSTBUCT IONS TO ReCCIVLR:
CHARDO 00579
BFG TECHNICAL DOCUMENT
AUG 0 3 1982
THE BF GOODRICH COMPANY CHEMICAL GROUP
REPORT
1-------r_...... ....................... AA .UUTTtr-CGRW
A.
|
S, PAZUR
---------------t1. .CC4JICM
ALTC -
----------
B/41S
, 1 Cl. A ' F
, ----------------
7-30-B2
. ........... .........
II I ...........
' 0O<", (JbO0uuKv, Rf!*;f*F. fpFf'f"r,vfH. i'i LI'. k
111-50-141
rko'.i' a ral> bv
J. SIMMONS
LOG A T ION
CLEVELAND
P Z ,,< A C 1 o
3791
,'i K '7 'A FJ C , i. k A l___ _ N iJ .
TfWj *'b
'S'if k J C T -
CHARDON RUBBER - H^S TESTING OF FORD BODY SIDE MOLDING
...I ,i
11
.... . ....------- --g
:
Introduction:
Chardon Rubber submitted samples of the Ford slider window profile for H^S
sulfide stain testing of the Geon 83463 Trans 002 topcoat.
L
Cone!usion:
The profile exhibited no change when tested for sulfide staining, and therefore passes the Ford requirement.
Future Work:
No further work is planned.
Results and Discussion:
Profile sections ware tested to Ford Test Method FLTM AN2-1 "Resistance of Plastic Materials to Hydrogen Sulfide Staining," as specified in Ford Material Specification ESB-M4D284-C. The test specifies a minimum rating
of 5 (no change) on the AATCC Chart for color change after exposure. The profile showed no detectable color change, and therefore, passes the require ment.
| !
j
ASP:fl
cc: G. A. Small P.F.V. Lloyd F. C. DeWolf R. J. Meyer/Int'l. CTF - ALTC
,;B. Wadey/P. J. Weaver ' s. Washko /C-t^osS
A/ `I
A."S. Pazur
(WT'Mhi'j.
IN J.A.
CHARDO 00580
373 Washington Si-reef Chordon. Ohto 44024 (216) 285-2161
June 2, 1983
Mylar Locking Strip Information 8 Cost Considerations
Mylar supplier contact
Dorrie Process, Norwalk, Conn. 06852 Warren Hicks - 203-846-2087
Mylar Type
- V-3060H 1 mil PVC top coated, 1 mil metalized mylar 6 mil "rigid" PVC
Mylar Cost
- $4.06/54" yd. (5/1/83], 333 ft. yield/yd. when slit .470 wide allowing 3% slitter scrap.
Mylar Slitting Supplier -Euclid Spiral Paper Tube Co., Apple Creek, Ohio 44606
contact
- Len Buckner 216-698-4711
slitting cost - $. 25/lb + 25.50 set up
gen'l info. -
mylar is to slit .470" wide in rolls as long as possible to 3,000 ft.
Processing information: Line to run at 25'/min. net yield. Scrap rate approximated at 20% Part length (finished) to be: Ram - 143" +1/4 -3/8 Ranger - 118" +1/4"
"Parts are to annealed for 1 hr. @ 212 Cut length on extrusion line to allow for shrinkage of approximately 5% when annealed. Parts are to be packaged in returnable containers. Technical assistance for processing is available from: Prototype Extrusions Rotterdam, N.Y. 12303 Contact: Rod Bakos 518-372-0404
Compounds to be used are:
Chardon Rubber Co. - 609140 Black B.F. Goodrich - 86195 Trans 001 clear
This information is to be updated and additional information added as necessary.
CHARDO 00581