Document wDjRnVD35ga3ogLVpmZN4Y2d4
Heating Systems Specialties
Yamall-Waring Company
Manufacturers of
Steam Specialties
7600 Queen Street, Philadelphia 18, Pa.
YARWAY IMPULSE STEAM TRAPS
Construction:--The Yarway Impulse Steam Trap is lihique in that there is only one moving part, the simple valve F. This trap is made of bar stock throughout, no castings used. For pressures up to 400 lb, body and .bonnet of cold rolled steel, cadmium plated; cap of tobin bronze, valve and seat of heat treated stainless steel. For pressures 400 to 600 lb, trap is all stainless steel.
Operation--Movement of valve (F) is governed by changes in pressure in control chamber (K). At lower temperatures, con densate- bypassing, continuously through orifice in center of valve reduces chamber pressure below inlet pressure and valve opens, allowing free discharge of air and condensate through seat. As condensate approaches steam temperature, low cham ber pressure causes vaporizing and the
increased volume builds up pressure in control chamber, closing valve (F).
List Prices, Weights and Dimensions
No. 60 Series--up to 400 lb. and No. 120 Series--up to 600 lb.
Advantages
Light Weight--Yarway traps need no support--H in. trap weighs only 1% lb. 2 in. trap weighs 8% lb.
Small Size--Can be installed in cramped quarters--% in. trap measures 2% in. long--2 in. trap, 4% in. long.
Will not air bind. Require no priming. Insure quick heating. Operate on exclusive Impulse principle (U.5. Patents No. 2,051,782and 2,127,649.) Low Price--Often cheaper than repair ing old traps. Factory set to operate at all pressures up to 400 lb (or 600 lb) without change oi valve seat. Send for descriptive Bulletin T-1739.
Size
Vi* No*. 60 or 120 Vi* No*. 61 or 121l; No*. 63 or 123 Wi* No*. 64 or 124 V/i* Nos. 66 or 126 2' Nos. 67 or 127
Trap Complete
$15.00 22.00 31.00 48.00 68.00 90X0
Weight Pounds
M/4 2 2Vl ' 4 5V. Wi
Length Inches
2Vt 3 3Ve W4 4*/* 4%
Yarway Fine-Screen Strainers offer better protection against rust, scale and dirt for all steam equipment.
Made in six standard sizes from } in. to 3 in. Cadmium plated, inside and out. High grade Monel woven-wire screens, Many thousands in use. Write for Bulletin
S-201.
YARWAY EXPANSION JOINTS
All-steel welded construction; light but strong. Chromium covered sliding sleeves.
Cylinder guide and stuffing box integral, assuring perfect alignment. Internal
limit stops. Gun-pakt and Gland-pakt types: Gun-pakt (illustrated) fitted with screw guns which permit addition
of plastic packing while joint is under pressure. Sizes 2 in. to 24 in., single end or double end, flanged or welding ends; 150, 300 and 400 lb pressures. Also all-brass joints, in. to 2 in. For additional details send for Bulletin
EJ-1911.
1232
Heating Systems Valves, Air
Anderson Products
INC.
Cambridge 39, Massachusetts
Vent-Rite Air and Vacuum Venting Valves for Radiators Vent-Rite No. 66 Control Valves Vent-Rite Unit Heater Valves
For Profitable, Efficient Venting Valve Installations . . . Specify Vent-Rite
The elimination of valve trouble caused by unavoidable accumulation of dirt can immediately be effected by use of Vent-Rite Air and Vacuum Venting Valves. Every VentRite Valve can be quickly and easily taken apart, cleaned, reassembled and adjusted, and restored to its original working condition.
In rare cases where a part may have become damaged, the valve may be sent to the factory for complete recon ditioning. Only Vent-Rite Valves offer these advantages. '..It is easy to obtain the correct venting rate in each rddiator in a system, regardless of size or location, because
every Vent-Rite Valve has an exceptionally wide and complete range of venting rates. Adjustment of the vent ing rate at the individual valves is easily accomplished through a streamlined, convenient adjusting device. You can be sure of Balanced Radiation ... of even, uniform dis tribution of heat. .
Vent-Rite Air and Vacuum -Valves are built for both oneand two-pipe systems in a wide range of types, sizes, out lets, and venting capacities. (The Vent-Rite Line in cludes Non-Vacuum Valves Nos. 1, 51, 3, 5A & 55, and Vacuum Valves Nos. 2, 62, 4, 6A & 66.)
No.2
THE VENT-VAC SYSTEM Even temperatures are provided with the Vent-Vac System by continuing the distribution of steam between firing periods, he.steam is available through the use of heat left in the boiler and is distributed to the points where heat loss is greatest. To insure fast, uniform distribution of steam during the firing periods, it breaks the vacuum used between firing periods. This breaking of the vacuum occurs at a predetermined point, within the limits of the control, before the start of every firing cycle, provided the heat transfer from boiler to radiation has Jbeen completed. Vent-Rite Vacuum Valves are used iffconjunction with a Vent-Rite Control
Unit.' The system is simple, economical, and amazingly effective. Vent-Rite Control Units not only create vacuum in the system between firing periods, but also limit the amount of vacuum that can be created to the point beyond which the distribution of excessively expanded vapor would be inefficient.
REPAIRABLE
All Vent-Rite Valves are Repairable
VENT-RITE CONTROL VALVE Vent-Rite Control
Valve No. 66 is the heart of the Vent-Vac System of steam
control for automatically fired one-pipe systems. It takes
the place of a main line vent, limits the amount of vacuum
created, and breaks the vacuum at a pre-determined point,
within the limits of the control, before the start of every
firing cycle, provided the heat transfer from boiler to
No. 68
radiation.has been completed. It is entirely mechanical. With the Vent-Vac System, using a No. 66 Control Valve,
Vent-Rite Pioneered
a system is vacuum between firing periods, non-vacuum during the firing, combining the best of both systems and-
assuring Balanced Radiation . . . assuring even distribution
CONTROLLED VENTING BALANCED RADIATION
of heat to give more comfortable rooms for better living. REPAIRABLE VALVES
Send for Bulletins.
VENT-VAC SYSTEM
1233