CHAPTER 6
1946 Guide
Table 6. Coefficients of Transmission (U) of Frame Walls with Insulation Between Framing^ b
Coefficients ore expressed in Btu per (.hour) (square foot) (Fahrenheit .degree difference in temperature between the air on the two sides), and are based on an outside wind velocity of 15 mpk.
COEFFICIENT WITH NO
INSULATION
BETWEEN
FRAMING
COEFFICIENT WITH INSULATION BETWEEN FRAMING
Mineral Wool ob Vegetable Fibers in Blanket or Bat Fork0 (Thickness below)
1 IN.
2 IN.
3 IN.
3% IN. Mineral Wool
A B c D
O.II 0.12 0.13 0.14 0.15
0.078 0.083
0.088 ' 0.092
0.097
0.063 0.067 0.070 0.072 0.075
0.054
0.056 0.058 0.061 0.062
0.051 0.053 0.055 0.057 0.059
33 34 35
36 37
0.16 '
0.17 0.18 0.19 0.20
0.10
0.10 0.11 0.11 0.12
0.078 0.080 0.082 0.084 0.086
0.064 0.066 0.067 0.069 0.070
0.060 0.062 0.063
0.065 0.066
38
39 40 41 42
" 0.21 0.22 0.23
0.24 0.25
0.12 0.12 0.12 0.12 0.13
0.088 0.089
0.091 0.093 0.094
0.072 0.073 0.074 0.075 0.076
0.067 0.068 0.069 0.070 . -0.073
43 44 45 46 .47
0.20 0.13
0.27 0.14 0.28 . 0.14 0.29 0.14 0.30 0.14
0.096 0.097 0.098 0.10 0.10
0.077
0.078 0.079 0.080 0.080
' 0.072 0.073 0.073 0.075
0.075
48 49
50 51 52
0.31 0.14
0.10
0.081
^ 0.076
.53
0.32 0.15 0.33 0.15
0.10 0.10
, 0.082 0.083
' 0.077 0.077
54 55
'
. ..0.34 0.15
0.10
0.083
0.078
56
0.35 0.15
0.11
0.084
0.078
57
0M 0.15 027 0.16. 0.38 0.16 0.39 0.16 0.40 0.16
0.11
0.085
0.079
58
0.11
0.085
0.080
59
0.11 \ 0.086
0.080
60
0.11
0.086
0.081
61
0.11
0.087- -
0.082
62
0.41 0.42
0.43 0.44
0.16 0.16 0.17 0.17
0.11 0.11 0.11 0.11
0.087
0.088 0.088 0.089
0.082 0.082 0.082 0.083
63 64 65 66 .
This table may be used for determining the coefficients of transmission of frame constructions with
the types and thicknesses of insulation indicated in Columns A to D inclusive between framing. Columns
A, B and C may be used for walls, ceilings or roofs with only one air space between framing but are not.
applicable to ceilings with no flooring above.- (See Table 11.) Column D is applicable to walls only.
Example: Find the coefficient of transmission of a frame wall consisting of wood siding, in. insulating
board sheathing, studs,(gypsum lath and plaster, with 2 in. blanket insulation between studs.' -According
to Table 5. a^wall of this construction with no insulation between studs has a coefficient of 0.19 (Wall No.
4D). Referring to Column B above, it will be found that a wall of this value with 2 in. blanket insulation
between the studs has a coefficient of 0.034;
...
Coefficients corrected for 2x4 framing, 16 in. on centers--15 per cent of surface area.
Based on one air space between framing. '
*No air space.
. rr**it Transmission Coefficients of Building Materials
129 .
Table 7. Coefficients of Transmission (U) of Masonry Walls
Coefficients are expressed in Btu per (hour) (square foot) (Fahrenheit degree difference in temperature between the air on the two sides), and are based on an outside wind velocity of 16 mph.
Based on 4 in. hard brick and remainder common brick. The 8 in. and 10 in. tile figures are based on two cells in the direction of heat flow. The 12 in. tile is based on three cells in the direction of heat flow. -The 16 in. tile consists of one 10 in. and one 6 in. tile each having two cells in the direction of heat flow.
Limestone or sandstone. *These figures may be used with sufficient accuracy for concrete walls with stucco exterior finish.
Expanded slag, burned clay or pumice. '
/Thickness of plaster assumed % in.
Thickness of plaster assumed in.
Based on 2 in. furring strips; one air space.