1. ' opacification No. 1984 - dtrndrrd Therm:-1 Insulation for Pipe, Valves, Fittings and Equipment, i.ev f9 - is hereby mrde . part of thfc specific: tion.
2. - aohfit, orimer. Code HD. for this project will be Qisonite Primer
3. ny variation of thickness or class of insul tion or finishes contained herein 're to be taken up with this office.
4. Horizontal trnks insul; ted with Fo^aglra shall hrve Herw Density Vibr:cork installed between the support r.nd trnk.
5. It is recommended tht each shipment of Brerthing Plastic, Code HC, be tested by the field inspector, for approval by using the right angle test as taken from "Test Procedure for Testing Finishes for
Thermal Insulation (Codes IX and IX) - Standard Specification 1984.
6. >\ll hot bare surfaces thro are exposed to body contact, and where the temperature of the surf: ce is rbove 140F shall be insulated for protection.
7* Where dripping from cordons:tion Is objectionable, insul te lines 1W - H3-, "i& finish.
8, Where Clrss HI. is herein specified. Class HIF may be substituted.
> Where Ml/. + ..'1H is herein specified. Class M1F of an equal thickness of thB combination of the I>i<: N1H mry be used.
10. Class Nil*', Calcium iilic'te, block nd sectional pipe insulation
temperature range - 1>0 to 1200'F. shrll consist of stable, cellular, calcine, fire clay base insul ting materiel. It shall hrve good mechanical strength with low shrink; ge. With "K" <- t >00F, not over 0.>8. .mterirl is manuf: ctured by Owens* Illinois Glrss Company and the uuberoid Comp` ny.
Exceptions to Ctmdrrd^Therorl Insul.-tion Upecificr tion Ho. 1984:
11. Where Code KiH ie herein specified ''Tonschek", m# r.ufa ctured by the Philip Corey Co., is an acceptable tr teri.l.
12. dealers for Foamglas and cork:
Code Hit Code HP Code HP Code ::p
Alteon3" * i
Type ; Type k (Typo i.
tode N'
rormglas pipe covering
(Tyr ~ M-' iv brier tion of for-mgl; s fittings.
Cork pipe covering &Foamg.'_as Pipe Covering
Work rnd Foamglrs equipment insulation.
specieiefition '^CO Jfceea
DUP 0838111
2
14* All Foamgles insulated tanks located outdoors should be finished with 1/S" thick Inaul-Mnatic No. 4010 plus one layer of type nDM Inaul-knstic 1/32** thick, or two gallons per hundred square feet* Over this apply a layer of Brutura*
17* Removable covers shown on the attached Behests 8-29758, 8-29759, and E-29760 where applied outdoors should be sprayed with EE Finish* Where special covers are required they shall be as follows: Where special types of flange covers are required they shall be installed 03 per sketches 8-29738, 8-29739 end 8-29760, they are required as follows. Where removable covers are used and subject t? being wet by rain, hosing, etc. all batt joints are to be buttered with insulating cement. The cement must be covered with Code Nd.
16* Removable equipment, flanges or heads larger than 18* diameter shall be lagged with sheet metal.
*
.Specification Ho, 2960 oheet 43 4/26/31