Document w6q04meyqjjq6QNmYvyqnJ23

244 CHAPTER 18 1959 Guide Table 5.... Btuh Capacities and Cfm of Individual Ducts in Perimeter Systems Used in Crasvl-Space cr Basement Ccnstructicn (Ccndudsdi Section C For 6-Inch Individual Round Pipe and for Baseboard Diffuser* Only Bonnet Pressure 0.15 in. Static __________________ Bonnet Temperature /70 F No. of Bbowi Actual length of Pipe from Bonne! fo Diffuser--foot 5 to 15 20 25 30 35 40 45 50 55 60 65 70 75 80 o- Btuh Cfm 8570 8000 7450 6910 6420 5960 5560 5150 4800 4450 4160 109.0 107.2 105.5 103.7 102.0 100.4 98.8 97.5 96.1 94.8 93.5 1 Btuh Cfm 8700 8100 7550 7000 6520 6060 5630 5250 4860 4530 4220 3930 105.5 104.0 102.3 100.7 99.2 97.6 96.2 95.0 93.6 92.3 91.1 90.0 2 Btuh am 8890 8270 7700 7160 6660 6200 5750 5350 4980 4620 4300 4000 3700 102.8 101.3 99.8 98.2 96.7 95.3 94.0 92.7 91.5 90.2 89.0 87.8 86.5 3 Btuh am 8440 7870 7320 6820 6350 5880 5460 5070 4700 4350 4020 3710 3440 98.4 96.8 95.3 93.9 92.5 91.3 90.0 89.0 88.0 86.9 85.8 84.7 83.5 4 Btuh am 8690 8080 7500 6980 6500 6030 5580 5180 4800 4450 4120 3820 3520 3250 95.8 94.4 93.0 91.6 90.3 89.0 87.8 86.7 85.7 84.6 83.7 82.6 81-6 80.5 5 Btuh Cfm 8940 8320 7740 7200 6680 6190 5720 5320 4920 4550 4220 3890 3600 3350 3100 93.4 92.2 91.0 89.8 88.5 87.3 86.2 84.8 83.8 82.8 81.7 80.8 79.9 79.0 78.0 6 Btuh Cfm 8580 7960 7380 6850 6350 5880 5440 5040 4660 4320 4000 3670 3400 3150 2930 90.0 89.8 87.6 86.5 85.5 .84.2 83.1 82.0 80.9 80.0 79.0 78.0 77.3 76.5 76.0 The Equivelait Length Vslora used end included in cnlcuUting this table are: Diffuser end Boot 100 ft; Plenum T*ke-off -- ft; Bach Elbow 14 ft. Tor edditiosal 14 ft equivalent Length of boot end diffuser count one additional elbow. Ait cfm values are based on etandard air. needed. Sectioo A la for 5-in. duct, Section B is for 6-in. duct using side-wall or floor diffusers, and Section C is for 6-in. duct using baseboard diffusers. Perimeter Extended-Plenum Systems in Crawl- Space or Basement Construction The considerations involved in the design of extendedplenum systems are essentially the same as those of the in dividual pipe system. A simplified design procedure is sum marized as follows: 1. Calculate the heat loss of each room or area using the method explained in Chapter 12. Consider the basement or crawl space as a part of the structure and calculate its heat loss. Information m Manual 3* supplements that contained in Chapter 12, particularly with respect to crawl-space heat losses. 2. Determine the required furnace-bonnet capacity from the heat loss of the building. 3. Locate the diffusers on the plan. Allow at least one dif fuser for each exposed wall in each room or area of building, and preferably beneath window areas. For residential installa tions limit each diffuser to a mayimtim of 7,000 Btuh. 4. Determine the required Btuh delivery of each diffuser. Where more than one diffuser is used per room, proportion the heat loss equally among all diffusers. 5. Measure the length of each duct and count number of elbows from the extended plenum to the diffuser. Note whether top or aide plenum take-offs are to be used. From Table 6, determine the duct size needed. (Note: Use that section of Table 6, Sections A to F, which applies both to the type of plenum take-off and diffuser to be used.) 6. The cfm values in Table 6 are used with Table 7 for sizing the extended-plenum system. No one extended plenum should exceed 35 ft in length, Design of Return Duct System for Perimeter In stallations With perimeter systems designed in accordance with the foregoing amplified procedures, there is a circulating head of only 0.05 in. water available on the return side of the system. It is therefore necessary that the return ducts be adequately sized and be as short and straight as practicable. The return grilles may be centrally Located, and the ducts may be located in the attic or other unheated .spaces pro vided they are adequately insulated. Return air may be taken from basements and crawl spaces, but should not be taken from confined spaces in which the furnace is located. 1116 following simplified procedure* may be used: 1. Lay out the return-air duct system. Measure the length and count the number of 90 deg turns in each return duct. 2. Total the heat lose of the area served by each return duet. 3. Determine the required duct free area from the length of duct, the number of 90 deg turns, and the heat loss wmg Table 8. Also determine the free area of the return grille from Tables. Other Perimeter Systems Each of the foregoing procedures can be used with ap proved furnaces that are capable of delivering their rated cfm air volume against a total pressure of 0.20 in. water external to the furnace. This available pressure is usually dis tributed on the basis of three-fourths (0.15 in. water) on the supply side and one-fourth (0.05 in. water) on the return side. Other systems, such as perimeter crawl-space plenum systems, may be designed by procedures outlined in Manual 4. In addition, procedures for designing 4-in. diameter duct systems are contained* in Manual 10 of the National Warm Air Heating and Air Conditioning Association, Other systems of a proprietary nature but utilizing the perimeter concept of diffuser placement are in common use. These systems should be designed and installed in strict accordance with the manufacturer's recommendations. Such systems usually utilize smaller ducts (4 in. or less) and higher pressures (above 050 in. water). They also may re- Warm Air Heating Systems 245 Table 6.... Heating Capacities and Cfm of Branch Ducts in ExtendedPlenum Perimeter Systems $<lion A. Side Takeoff to 5-fctch Bound Pipe far Side-woD, Hoar, end Baseboard Diffusers Extended-Plenum Pressure 0.16 in. Static at 160 F Furnace-Plenum Pressure 0.16 in. Static at 170 F Acfuaf lec^fb from Exfended-Pfeoua fo Diffuse*--Feel 5 10 15 20 25 30 35 40 45 so 55 60 0 Btuh 8960 8100 7310 6550 5900 5310 4800 4330 3900 3510 3170 2850 Cfm 97.2 93.1 89.4 86.0 83.0 81.2 77.7 75.5 73.1 71.1 69.3 67.8 1 Btuh 8070 7290 6580 5950 5400 .4880 4400 3980' 3550 3200 2900 2620 am 88.4 85.2 82.2 79.3 76.9 74.6 72.5 70.7 68.9 67.1 65.7 64.2 2 Btuh 7340 6650 6020 5460 4950 4500 4070 3680 3300 2980 2680 2410 am 81.1 78.6 76.0 73.9 71.9 70.0 68.2 66.6 64.1 63.7 62.3 61.0 3 Btuh 6810 6180 5600 5070 4610 4200 3800 3420 3080 2770 2480 2230 Cfm 75.0 73.0 71.0 69.2 67.3 65.8 64.4 63.1 61.7 60.2 59.0 58.2 4 Btuh 6350 5750 5210 4740 4300 3900 3530 3180 2870 2570 2300 2070 am 70.4 68.8 67.0 65.4 64.0 62.5 61.1 60.0 58.8 57.7 56.7 55.9 5 Btuh 5970 5400 4900 4440 4040 3670 3330 2990 2770 2410 2160 1930 am 65.2 64.8 63.2 62.0 60.7 59.4 58.3 57.4 56.2 55.3 54.4 53.7 6 Btuh 5660 5120 4630 4190 3800 3430 3100 2800 2520 2270 2040 1800 am 63.0 61.5 60.2 59.1 58.0 56.9 55.9 55.1 54.0 53.0 62.2 51.8 Note: Wbeie any ol tbe first three runt from the extended-pienum exceeds 9) ft end 3 elbow*, coast 3 extra elbow* for th*t run. The Equivalent Length Values used and included in calculating this table are: Diffuser and Boot -- 39 ft; Each Elbow * 13 ft; Side Take-off -- 20 ft. Tapered Extended-Plenum Starting Collar. Sadion B. Top Take-off to 5-tndi Round Pipe for Side-wall, Floor, and Bateboard Diffusers Extended-Plenum Pressure 0.16 in. iSiafte at 160 F Furnace-Plenum Pressure 0.15 in. Static at 17OF No. of Shows Actual length from Extondod-Phnua to Diffuse*--feet . 5 10 15 20 25 30 35 40 45 50 55 60 0 Btuh '7070 6400 5800 5260 4800 4350 3940 3550 3190 2870 2580 2310 am 77.8 75.6 73.4 71.4 69.5 68.0 66.4 64.8 63.4 62.0 60.6 59.5 1 Btuh 6570 5970 5400 4890 4430 4010 3640 3290 2950 2650 2380 2140 Cfm 72.6 70.8 68.9 67.2 65.6 64.2 62.8 61.5 60.3 59.0 58.0 57.0 2 Btuh 6180 5610 5080 4590 4160 3770 3410 3080 2770 2480 2210 2000 am 68.4 66.8 65.2 63.7 62.3 61.1 60.0 68.7 57.6 56.4 55.3 54.4 3 Btuh 5800 , 5250 4750 4310 3900 3540 3200 2890 2600 2340 2100 1870 Cfm 64.4 63.1 61.8 60.5 59.3 58.3 57.1 56.3 55.5 54.7 53.9 53.2 4 Btuh 5490 4960 4500 4080 3700 3340 3020 2720 2440 2200 - 1970 1750 Cfm 61.2 60.0 58.8 57.8 56.7 55.8 54.9 54.1 53.3 52.6 51.9 51.1 5 Btuh 5200 4710 4280 3870 3510 3180 2880 2580 2310 2060 1830 1640 am 58.5 57.5 56.5 55.5 54.5 53.7 52.9 52.1 51.4 50-7 50.0 49.5 6 Btuh 5000 4520 5100 3700 3350 3010 2700 2440 2160 1910 1700 1551 Cfm 56.0 55.0 54.0 53.4 52.4 51.7 51.0 50.5 59.7- 49.1 48.6 48.1 Note: Where may of the first three runs from tbe extended-plenum exceed* 20 ft and 3 elbows, count 3 extra elbows for that run. Tbe Equivalent Length Value* used and included in calculating this table are: Diffuser and Boot * 39 ft; Eaeh Elbow TM 12 ft; Top Take-off -- 90 ft. Tapered EitoaM.Plmnm Starting Collar. quire special streamlined, low resistance fittings and special diffusers. Some systems also employ higher bonnet tempera tures. When either higher bonnet pressures or temperatures, or both, are to be used, care must be taken to ascertain that the furnace employed is capable of meeting the required conditions. INSIDE WALL DELIVERY SYSTEMS The concept of warm-air perimeter heating is relatively new.'The older methods of introducing warm air into spaces use other outlet locations. One of the most common of these has been the use of register locations on a warm or inside