CHAPTER 18
1959 Guide
Table 5.... Btuh Capacities and Cfm of Individual Ducts in Perimeter Systems Used in Crasvl-Space cr Basement Ccnstructicn (Ccndudsdi
Section C For 6-Inch Individual Round Pipe and for Baseboard Diffuser* Only
Bonnet Pressure 0.15 in. Static
__________________
Bonnet Temperature /70 F
No. of Bbowi
Actual length of Pipe from Bonne! fo Diffuser--foot 5 to 15 20 25 30 35 40 45 50 55 60 65 70 75 80
o- Btuh Cfm
8570 8000 7450 6910 6420 5960 5560 5150 4800 4450 4160 109.0 107.2 105.5 103.7 102.0 100.4 98.8 97.5 96.1 94.8 93.5
1 Btuh Cfm
8700 8100 7550 7000 6520 6060 5630 5250 4860 4530 4220 3930 105.5 104.0 102.3 100.7 99.2 97.6 96.2 95.0 93.6 92.3 91.1 90.0
2 Btuh am
8890 8270 7700 7160 6660 6200 5750 5350 4980 4620 4300 4000 3700 102.8 101.3 99.8 98.2 96.7 95.3 94.0 92.7 91.5 90.2 89.0 87.8 86.5
3 Btuh am
8440 7870 7320 6820 6350 5880 5460 5070 4700 4350 4020 3710 3440 98.4 96.8 95.3 93.9 92.5 91.3 90.0 89.0 88.0 86.9 85.8 84.7 83.5
4 Btuh am
8690 8080 7500 6980 6500 6030 5580 5180 4800 4450 4120 3820 3520 3250 95.8 94.4 93.0 91.6 90.3 89.0 87.8 86.7 85.7 84.6 83.7 82.6 81-6 80.5
5 Btuh Cfm
8940 8320 7740 7200 6680 6190 5720 5320 4920 4550 4220 3890 3600 3350 3100 93.4 92.2 91.0 89.8 88.5 87.3 86.2 84.8 83.8 82.8 81.7 80.8 79.9 79.0 78.0
6 Btuh Cfm
8580 7960 7380 6850 6350 5880 5440 5040 4660 4320 4000 3670 3400 3150 2930 90.0 89.8 87.6 86.5 85.5 .84.2 83.1 82.0 80.9 80.0 79.0 78.0 77.3 76.5 76.0
The Equivelait Length Vslora used end included in cnlcuUting this table are: Diffuser end Boot 100 ft; Plenum T*ke-off -- ft; Bach Elbow 14 ft. Tor edditiosal 14 ft equivalent Length of boot end diffuser count one additional elbow.
Ait cfm values are based on etandard air.
needed. Sectioo A la for 5-in. duct, Section B is for 6-in. duct using side-wall or floor diffusers, and Section C is for 6-in. duct using baseboard diffusers.
Perimeter Extended-Plenum Systems in Crawl-
Space or Basement Construction
The considerations involved in the design of extendedplenum systems are essentially the same as those of the in dividual pipe system. A simplified design procedure is sum marized as follows:
1. Calculate the heat loss of each room or area using the method explained in Chapter 12. Consider the basement or crawl space as a part of the structure and calculate its heat loss. Information m Manual 3* supplements that contained in Chapter 12, particularly with respect to crawl-space heat losses.
2. Determine the required furnace-bonnet capacity from the heat loss of the building.
3. Locate the diffusers on the plan. Allow at least one dif fuser for each exposed wall in each room or area of building, and preferably beneath window areas. For residential installa tions limit each diffuser to a mayimtim of 7,000 Btuh.
4. Determine the required Btuh delivery of each diffuser. Where more than one diffuser is used per room, proportion the heat loss equally among all diffusers.
5. Measure the length of each duct and count number of elbows from the extended plenum to the diffuser. Note whether top or aide plenum take-offs are to be used. From Table 6, determine the duct size needed. (Note: Use that section of Table 6, Sections A to F, which applies both to the type of plenum take-off and diffuser to be used.)
6. The cfm values in Table 6 are used with Table 7 for sizing the extended-plenum system. No one extended plenum should exceed 35 ft in length,
Design of Return Duct System for Perimeter In stallations
With perimeter systems designed in accordance with the foregoing amplified procedures, there is a circulating head
of only 0.05 in. water available on the return side of the system. It is therefore necessary that the return ducts be adequately sized and be as short and straight as practicable. The return grilles may be centrally Located, and the ducts may be located in the attic or other unheated .spaces pro vided they are adequately insulated. Return air may be taken from basements and crawl spaces, but should not be taken from confined spaces in which the furnace is located.
1116 following simplified procedure* may be used:
1. Lay out the return-air duct system. Measure the length and count the number of 90 deg turns in each return duct.
2. Total the heat lose of the area served by each return duet. 3. Determine the required duct free area from the length of duct, the number of 90 deg turns, and the heat loss wmg Table 8. Also determine the free area of the return grille from Tables.
Other Perimeter Systems
Each of the foregoing procedures can be used with ap proved furnaces that are capable of delivering their rated cfm air volume against a total pressure of 0.20 in. water external to the furnace. This available pressure is usually dis tributed on the basis of three-fourths (0.15 in. water) on the supply side and one-fourth (0.05 in. water) on the return side. Other systems, such as perimeter crawl-space plenum systems, may be designed by procedures outlined in Manual 4. In addition, procedures for designing 4-in. diameter duct systems are contained* in Manual 10 of the National Warm Air Heating and Air Conditioning Association,
Other systems of a proprietary nature but utilizing the perimeter concept of diffuser placement are in common use. These systems should be designed and installed in strict accordance with the manufacturer's recommendations. Such systems usually utilize smaller ducts (4 in. or less) and higher pressures (above 050 in. water). They also may re-
Warm Air Heating Systems
245
Table 6.... Heating Capacities and Cfm of Branch Ducts in ExtendedPlenum Perimeter Systems
$<lion A. Side Takeoff to 5-fctch Bound Pipe far Side-woD, Hoar, end Baseboard Diffusers
Extended-Plenum Pressure 0.16 in. Static at 160 F
Furnace-Plenum Pressure 0.16 in. Static at 170 F
Acfuaf lec^fb from Exfended-Pfeoua fo Diffuse*--Feel
5 10 15 20 25 30 35 40 45 so 55 60
0
Btuh
8960
8100
7310
6550
5900
5310
4800
4330
3900
3510
3170
2850
Cfm
97.2
93.1
89.4
86.0
83.0
81.2
77.7
75.5
73.1
71.1
69.3
67.8
1
Btuh
8070
7290
6580
5950
5400 .4880
4400
3980' 3550
3200
2900
2620
am
88.4
85.2
82.2
79.3
76.9
74.6
72.5
70.7
68.9
67.1
65.7
64.2
2
Btuh
7340
6650
6020
5460
4950
4500
4070
3680
3300
2980
2680
2410
am
81.1
78.6
76.0
73.9
71.9
70.0
68.2
66.6
64.1
63.7
62.3
61.0
3
Btuh
6810
6180
5600
5070
4610
4200
3800
3420
3080
2770
2480
2230
Cfm
75.0
73.0
71.0
69.2
67.3
65.8
64.4
63.1
61.7
60.2
59.0
58.2
4
Btuh
6350
5750
5210
4740
4300
3900
3530
3180
2870
2570
2300
2070
am
70.4
68.8
67.0
65.4
64.0
62.5
61.1
60.0
58.8
57.7
56.7
55.9
5
Btuh
5970
5400
4900
4440
4040
3670
3330
2990
2770
2410
2160
1930
am
65.2
64.8
63.2
62.0
60.7
59.4
58.3
57.4
56.2
55.3
54.4
53.7
6
Btuh
5660
5120
4630
4190
3800
3430
3100
2800
2520
2270
2040
1800
am
63.0
61.5
60.2
59.1
58.0
56.9
55.9
55.1
54.0
53.0
62.2
51.8
Note: Wbeie any ol tbe first three runt from the extended-pienum exceeds 9) ft end 3 elbow*, coast 3 extra elbow* for th*t run. The Equivalent Length Values used and included in calculating this table are: Diffuser and Boot -- 39 ft; Each Elbow * 13 ft; Side Take-off -- 20 ft. Tapered Extended-Plenum Starting Collar.
Sadion B. Top Take-off to 5-tndi Round Pipe for Side-wall, Floor, and Bateboard Diffusers
Extended-Plenum Pressure 0.16 in. iSiafte at 160 F
Furnace-Plenum Pressure 0.15 in. Static at 17OF
No. of Shows
Actual length from Extondod-Phnua to Diffuse*--feet . 5 10 15 20 25 30 35 40 45 50 55 60
0
Btuh
'7070
6400
5800
5260
4800
4350
3940
3550
3190
2870
2580
2310
am
77.8
75.6
73.4
71.4
69.5
68.0
66.4
64.8
63.4
62.0
60.6
59.5
1
Btuh
6570
5970
5400
4890
4430
4010
3640
3290
2950
2650
2380
2140
Cfm
72.6
70.8
68.9
67.2
65.6
64.2
62.8
61.5
60.3
59.0
58.0
57.0
2
Btuh
6180
5610
5080
4590
4160
3770
3410
3080
2770
2480
2210
2000
am
68.4
66.8
65.2
63.7
62.3
61.1
60.0
68.7
57.6
56.4
55.3
54.4
3
Btuh
5800 , 5250
4750
4310
3900
3540
3200
2890
2600
2340
2100
1870
Cfm
64.4
63.1
61.8
60.5
59.3
58.3
57.1
56.3
55.5
54.7
53.9
53.2
4
Btuh
5490
4960
4500
4080
3700
3340
3020
2720
2440
2200 - 1970
1750
Cfm
61.2
60.0
58.8
57.8
56.7
55.8
54.9
54.1
53.3
52.6
51.9
51.1
5
Btuh
5200
4710
4280
3870
3510
3180
2880
2580
2310
2060
1830
1640
am
58.5
57.5
56.5
55.5
54.5
53.7
52.9
52.1
51.4
50-7
50.0
49.5
6
Btuh
5000
4520
5100
3700
3350
3010
2700
2440
2160
1910
1700
1551
Cfm
56.0
55.0
54.0
53.4
52.4
51.7
51.0
50.5
59.7- 49.1
48.6
48.1
Note: Where may of the first three runs from tbe extended-plenum exceed* 20 ft and 3 elbows, count 3 extra elbows for that run. Tbe Equivalent Length Value* used and included in calculating this table are: Diffuser and Boot * 39 ft; Eaeh Elbow TM 12 ft; Top Take-off -- 90 ft. Tapered EitoaM.Plmnm Starting Collar.
quire special streamlined, low resistance fittings and special diffusers. Some systems also employ higher bonnet tempera tures. When either higher bonnet pressures or temperatures, or both, are to be used, care must be taken to ascertain that the furnace employed is capable of meeting the required conditions.
INSIDE WALL DELIVERY SYSTEMS
The concept of warm-air perimeter heating is relatively new.'The older methods of introducing warm air into spaces use other outlet locations. One of the most common of these has been the use of register locations on a warm or inside