Document w12DDEr13wpLNMLeMwbDxYQo
REYNOLDS METALS COMPANY RICHMONO. VIRGINIA 23261
October 9, 1986
-Editor OCCUPATIONAL HAZARDS 1111 Chester Avenue Cleveland, Ohio 66116
Dear Sir:
Your article, "Shopper's Guide to Hand and Body Protection, " in the September issue, recommended the use of aluminum or asbestos hoods, sleeves, leggings, coats, and full body suits for workers exposed to intense heat sources. Due to the potential for exposure to asbestos fibers while using asbestos clothing, hoods, etc., I question the safety of your recommendation.
In the December 1982 issue of the Journal of the American Industrial Hugiene Association, Samini and Williams reported that employee exposures to asbestos fibers while wearing asbestos gloves were as high as 2.6 fibers/cc TWA concentration. In addition, significant numbers of asbestos fibers were detected on the worktable (9953 to 13,108 fibers >5\i) and on the hands after removing the gloves (761 to 3860 fibers).
This problem would, of coarse, be compounded by the use of hoods, sleeves, leggings, coats, or full body suits.
Currently, there are several substitutes for asbestos gloves (Zetex, Nomex, Kevlar) which have been showg to provide protection against sustained temperatures of up to 590 C. These same materials should also be quite effective as leggings, hoods, or full body suits. A new product, polybenzimidazole (PBI) developed by. Celanese for NASA, appears to offer an excellent substitute for asbestos full body suits.
In any event, the inherent risks associated with the use of asbestos clothing precludes its application within Reynolds Metals Company.
REB/mjm
Ronald E. Benton Technical Manager Industrial Hygiene
TX TINER RMC0064051