Document vyj9NnvYaVypY4Vr5LYgJwp6Z

Determination of HC1 in Aroclor 1111 Scope This method measures HCl concentrations from 0.01 meq/lOOg. to 6.0 meq/lOOg. Principle This method is intended for the determination of acidity attributable to HCl in the Aroclor 1111. it involves a total acid titration with standardized NaOll. Reagents 1. Toluene, ASTM Grade 2. Sodium Hydroxide, 0.1N. 3. Hydrochloric Acid, 0.1N. .4 Nitrogen ' Apparatus 1. 2-Burets, graduated in 0.1 ml divisions 2. Separatory funnels, 250 ml. 3. ISO ml, coarse, ASTM 40-60, Pyrex glass sintered funn .4 Erlenmeyer Flasks, 250 ml. 5. No. 13-1/2 Rubber stopper with one hole $. Pan Balance 7. Small glass funnels 9. Cotton HONS 021721 Procedure 1. Add by buret 10.0 ml. 0.1N NaOH to the separatory funnel. 2. Add 100 ml toluene to the separatory funnel. 3. Get total tare weight on funnel, toluene, and NaOH. 4. Pour or drain (not pi pet) approx. 50 gm of Aroclor into the glass sintered funnel which is placed in the separatory funnel. 5. Place rubber stopper over glass sintered funnel and force the Aroclor thru the filter with nitrogen. 6. Reweigh separatory funnel to get the wc ight of the sample. 7. Extract sample with the NaOH layer. S. Filter extract through cotton plug into the Erlenmeyer flask. 9. Nash organic layer with 50 ml. distilled h20. 10. Filter extract again and repeat H,0 wash and filter. 11. Add methyl red indicator. 12. If solution is red, titrate with 0.1N NaOH to siethy 1 red end-point. 13. It solution is yellow, titrate with 0.1N HC1 to methyl red end-point. HONS 0Z17ZZ Calculations if 0.1N HC1 is used: meq/lOOg acid (10.0 - ml 0.In HCl used) (N) U00) ' sample weight if O.lN NaOH is used: meg/lOOg acid (10.0 + ml O.lN NaOH used) (N) (100) sample weight Notes The sample cannot be drawn with a pipet because the vacuum will draw off the HC1. A qualitative test for HCl can be used with this procedure also. Alkacid test paper can be exposed to the fumes above the sample. Trace amounts of HCl can be detected by this method, down to 0.1 meq/lOOg. Sample must be kept above 54*C. Otherwise, solids will form. MONS 011723