Document vmVeoMKYB1ypNzbOp6wOkdb9

Heaters, Unit Modine Manufacturing Co. 17th and Holburn Streets, Racine, Wisconsin Branches in All Principal Cities MODINE UNIT HEATERS Application--Not only successfully used for industrial, garage and similar space-heating applications, but ideally suited also to show-rooms, stores, oil stations, churches, school rooms, resi- Center opening 15 patented provision for direct suspension from Steam Supply Branch Upper Header is a copper pipe Tabes brazed into header at 1350 degrees F Red-brass tubes round for strength Resist corrosion even better than copper At this point Velocity Generator .straightens oat air stream from fan Copper Fins Fins metallically bonded to tubes Lower Header is a copper pipe Bronze Outlet Casting structurally but assure far more effective, economical distribution of heat: (I) The Expansion Bend given each tube of the condenser before entering lower header, provides for free expansion, thus eliminat ing expansion strain from being transferred to header tanks. (2) Velocity Generator for redirecting and controlling the heated air stream, assures greater possible throw consistent with comfortable heating. (3) Direct Pipe Suspension greatly facili tates horizontal redirection of the heated air stream, permitting full 360 deg rotatability. Also means far easier instal lation, at less cost--no brackets, pipe rods or straps being necessary. Write for Unit Heater Catalog 635. . MODINE COPPER CONVECTORS A convector comparatively light yet unusually sturdy in construction. Avail able in a wide range of sizes and four general types--Concealed, Recessed, Floor Cabinet and Wall Cabinet. For steam, vapor or vacuum systems; line also in cludes a hot water type copper radiator designed specifically for hot water systems. Write for Catalog 135. - Bach tube of condenser, before entering lower header, bends in a way which provides for* free expansion. dential recreation rooms, etc. They have also effected important economies in the drying of paint, leather, enamels, paper, wood, etc., by speeding up and bettering the drying process. Description--Exclusive features that not only make the Modine a better unit MODINE UNIT HEATERS MODINE COPPER-CAST RADIATORS A combination of copper and cast-iron, that combines converted and radiated heat for greatest comfort and economy! Modine Copper-Cast heats faster than cast-iron because of the copper convection unit, and cools much slower than unas sisted convectors, thus maintaining a more even temperature than either. Write for Catalog 135. CAPACITIES AND DIMENSIONS (In Inches) Model No. Over all Width Height Depth Less Motor E.D.R. C.F.lU.. Motor R.P.M. 76 126 152 181 204 238 275 352 440 542 710 903 1163 1545 2015 JJ14 16. 18 18 18 18 1% 22 23 i26% 30% 3036 9% 13 15 15 15 15 18 18 18 U 22 26 26 52>/t 56<A 5V 6 8 8 8 8 9 9 9 9 9 SR ii "1 76 126 152 181 204 238 275 352 440 542 710 903 1163 1545 2015 187^ 456 540 770 735 731 1052 1425 1320 1710 2230 3000 4050 5400 6540 1550 1590 1590 1140 1140 1140 1140 1140 1140 1125 1120 1125 1110 1125 1110 All above models are available with variable speed motors. Units for hot water application also available. MODINE HUMIDITIONER \ The^Humiditiener, a low cost domestic air conditioner used in conjunction with a radiator heating system. It humidifies, cleans, circulates heated air; can . be furnished -with cooling coil for Hiving quarter cooling. The Humiditioner is ordinarily installed in the basement, suspended from the ceiling where it takes up no floor space; gives benefits of air conditioning without sacrificing virtues of radiator heating. Write for Catalog 135. _ OTHER MODINE PRODUCTS Modine also offers complete lines of Blast Heaters, Cooling Coils and Unit Coolers. Data gladly furnished on request. 912 Healers, Unit The Unit Heater and Cooler Co. Wausau, Wisconsin Offices in Principal Cities MANUFACTURERS OF THE GRID UNIT GRID UNIT HEATER DATA Delivers More Warm Air to Floor and Working Zone `Varies with type of motor. Model No. Dimension* A B C D' Face Area Sq. Ft. Motor Volume at Hp. R.P.M. Fan Capacities 5 Lb. Press. 60 Air B.T.U. Final Temp. Approx, '--..Pipe Sizes Shipping Weight Supply Outlet 1015 ip/. 1514 9 14% 1020 ip/. 20'/, 9 H'/j .52 .69 1200 15 1214 ip/. 171/2 1.04 1500 22 18 i i'/i 20 1.67 1520 27 18 1114 20 2.2 2000 27 23'/, ll Vi 211/2 2.8 2025 32 23'/, H'/2 21% 3.6 2500 32 2S'/2 1114 28 4.5 2530 36 28'/2 11V4 28 5.3 3000 38 33 13% 29 6.5 1/30 1/30 1/20 1/30 1/10 1/20 1/8 1/20 1/6 . 1/10 1/6 1/10 1/2 1/4. 1/2 1/4 11/2 1/2 1600 1500 1700 1150 1750 1150 1750 1150 1150 850 1150 850 1150 850 1150 850 1(50 850 220 285 711 515 1450 1015 1700 1288 2500 1835 2875 2380 4200 3375 4650 3350 8(00 6350 19450 24200 46000 . 34900 77500 65500 104000 83500 148000 113000 177000 158500 225000 197000 282000 226000 394000 341000 119 122 109 118 113 118 114 117 - 115 120 108 113 115 121 104 109 90 100 y.* %' 120 ,, I1/.' 210 114' 250 IV4' 320 2* 370 2" 440 2* 500 V 725 i'h*. %' w 1'/," 1'/,1'/,' 1'/.* w w 1'/.' 1'/.' Grid Unit Heaters--Reduce fuel cost and maintenance expense--no damage possible to Grid due to electrolytic action as it cannot take place in Grid Units. Long Life--Efficient Service--Good for 250 lb. working pressure. Manifolds or Headers and Steam Chamber--Cast High Test Iron. Fin Surface--Aluminum alloy cast metal to metal bond with steam chamber. Lower outlet temperatures and greater volume delivers warm air to working zone of room, thus eliminating heat losses at ceiling and avoiding stratification. 913