Document vVqkK81rkR1kegEd7r5Lr404m
GLIDDEN-DURKEE
PROM* Mr. R. H. Ruzicka
Nov. 15, 1972
CITY* Strongsville, DPJRC
SUBJECT* LEAD-FREE DRIER SYSTEMS BOUSE PAINT
FORt - ->Mr. S. T. BoweXl
cc:
Mr. R. P. Shong Mr. F. G. Hidalgo
Mr. C. W. Wright - UCB
Mr. w. M. Tome
Mr. J. E. Southwick
Mr. R. W. Green
Dr. H. J. Kiefer - UCB Mr. G. Tj . Bechtel - u c b
Mr. H. (} Beck - UCB
Mr. E. B. Euchner
Six month check - TM-110B addendum.
The 6 month drier check was run only in the environmental room at 50 F. end 70% R.H. Loss of dry vras proportional for both the standard and lead-free systems indicating good shelf stability.
Paints with Mooney feeder drier #30 were wet after 34 hours in the environmental room, while paints with E-399 (Troykyd perma-Dry) dried in relation to their initial dry time rates. Further testing of Mooney #30 will be discontinued. Paint will be checked again after one year.
RHR/ab
Roy H. Ruzicka
GLD007138