Document vVo7Orgrmj68EXOMpM1xBnkBR
Company: DOW CHEMICAL Process: POLY-B
Node: 5 Page: 1
+---------------------------------------------------------------------------------------------------------------------
Node: 5 D-2002 TO R-2001 LIQUID LINE
. rameter: Flow
Intention: 20gpm
+-------------------
|GUIDEWORD (DEVIATION | POSSIBLE CAUSES | CONSEQUENCES
T
No
No Flow SUBJECT LINE
OVER FILL D-2002
BLOCKED
WRECK D-2002
SUBJECT LINE
INTERNALS
PLUGGED
HIGHER REACTOR
NO SPRAY INTO
PRESSURE
D-2002
FOUL EXCHANGER
TRAIN SHUTDOWN
COMPRESSOR TRIP
| RECOMMENDATIONS | BY
HIGH LEVEL ALARM *
HIGH DIFF.ALARM ON BOTH PACKING SECTIONS
*
OPERATOR TRAINING RF
WRITE OPER. PROCEDURES
MONITOR LEVEL
RF *
SEE NODE 3 LESS FLOW
GC
MINIMIZE HORIZ. PIPING
GC
More
More Flow FLUSH LINE LEAKING/OPEN MALFUNCTION OF D-2002 SPRAY CONTROL POOR TRAINING/ OPERATOR ERROR
HIGH CAT. CONC. IN BOTTOM OF REACTOR
LOW % SOLIDS IN REACTOR
WRITE OPER. PROCEDURES
RF
CONSIDER MONITORING FLUSH HEADER FLOW
GC
CONSIDER RESTRICTOR IN FLUSH HDR. LINE
GC
SEE NODE 3 LESS FLOW
GC
Reverse Reverse REACTOR O.H.
SAME AS NO FLOW
WRITE PROCEDURES RF
Flow
VAPOR LINE
BLOCKED/PLUGGED
+-------------- +-------------- +--------------------------- +----------------------------- +--------------------------- +
DO A 121094 CONFIDENTIAL
Company: DOW CHEMICAL Process: POLY-B
Node: 5 Page: 2
+-------------------------------------------------------------------------------------------------------------------------------------------------------------------- +
Node: 5 D-2002 TO R-2001 LIQUID LINE
I
rameter: Temperature
Intention:
|
+------------------------------------_--_------------------f------
|GUIDEWORD|DEVIATION| POSSIBLE CAUSES I CONSEQUENCES | RECOMMENDATIONS |BY j
+------------- +-------------- +--------------------------- +-----------------------------+--------------------------- +---- +
More
Higher
Temp
+------------- +-------------- +--------------------------- +-----------------------------+--------------------------- +---- +
A 12109^ C0NFI0ENTTA:
Company: DOW CHEMICAL Process: POLY-B
Node: 5 Page: 3
------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Node: 5 D-2002 TO R-2001 LIQUID LINE
rameter: Contamination
Intention: RUST/WATER FREE
H---------------- -------------1------------------- --------------H--------------------------------| ----------------------------|------------------------------------------- 1-
|GUIDEWORD|DEVIATION| POSSIBLE CAUSES | CONSEQUENCES ( RECOMMENDATIONS (BY j
More
More Cont IMPROPER CLEANING PRODUCT QUALITY PROCEDURES(RUST KILL REACTOR IN LINE/VESSEL)
WRITE ISOLATE/ CLEAN/COMMISION PROCEDURE
RF
D0 A 121096 CONFIDENTIAL
Company: DOW CHEMICAL Process: POLY-B
Node: 5 Page: 4
H------------ ---- -------------- --- -- ------------------------
------------------------------------------------------------------------- -------------- ------------------
----------------- ------------------------1-
Node: 5 D-2002 TO R-2001 LIQUID LINE
rameter: Level
Intention: NO LEVEL
------------------------+---------------------------------------- ----H------------------------------- ----+-------------------~~+" H
|GUIDEWORD|DEVIATION| POSSIBLE CAUSES | CONSEQUENCES | RECOMMENDATIONS |BY |
H---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------~--"----" --H----------------h
No No Level
More
More
Level +--------------------
SEE NO FLOW
SEE NO FLOW NODE * 5
DO A 121097 CONFIDENTIAL