Document vVXVLbbeGBz9Vavr0rzKG33dZ
Boilers and Radiators
Continental Heater Corporation
Dunkirk, N. Y.
MANUFACTURERS OF CAST IRON BOILERS AND RADIATORS
Boiler No.
4 5 6 7 8
CONTENTO BOILERS
Steam Rating Sq. Ft.
240 320 400 500 600
Water Rating Sq. Ft.
400 535 670 825 990
Overall Length Inches
20 23V, 27 30>/. 34
Grate Area
Sq.Ft.
.94 1.22 1.55
1.92 2.25
.
CONTINENTAL SQUARE BOILERS
Boiler No.
74 75 76 77 78 79
Steam Rating Sq.Ft.
450 650 825 1000 1175 1300
Water Overall Rating - Length Sq.Ft. `Inches
750
1075
1375 1600
1925 2150
24 28 32 37 41
46
Grate Area Sq. Ft.
1.5 2.0 2.5 3.0 3.5 4.0
Contento For installation on same floor with radiators or in
basement
Water line 46 in. Flow tapping 56 in. Four. five, six and seven section have 2--2in. flow
and returns; eight and nine section have 3-2M inflow and returns.
. Continental Square. Water
tube design. Burns any kind of fuel
CONTINENTAL RADIATORS
Each individual section is rigidly tested and inspected. After assembly each radiator receives a second test and inspection.
Continental radiators are dependable.
CONTINENTAL CLASSIC RADIATORS
Width
wFour Tube..................
Sq. Ft. per Section....
rSix Tube.. ...............
Sq. Ft. per Section__
38" 4/4
38" 6
32' 3'/2
32' 5
26" 23/4
26" 4
20" 2>/4
m'23" 20" 3
VAEight Tube................. 12" 20" 17"\ 14*
Sq. Ft. per Section___
3
Classic in Name Classic in Appearance
CONTINENTAL PLAIN RADIATION
Width One Column............... 5" 38" 32* 26" 23" 20" Two Column.............. 1W 38" 32" 26" 23" 20" Three Column........... 9* - 38" 32" 26" 22" 18" Four Column ............ \\%w 38* 32" 26" 22" 18" Five Column.............. 13V,' 22" 18" 14"
Wall Radiators are assembled with
screw nipples
386
Continental Heater Corporation
Boilers and Radiators
Continental Low Water Line Boilers
Smokeless and Regular Types
Interior View
Superior Features
Extremely low water line, that of largest boiler being only 47 inches. Fired short way of grates, making firing easy. Water tubes in fire box come in direct contact with flames. Good cir culation within boiler and large volume of water insures steady water line on fan systems. Made in regular and smokeless types. Will burn any kind of fuel including oil. Every boiler set up and rigidly tested before ship* ment.
CONTINENTAL LOW WATER LINE BOILER DATA {Ratings.have never been changed)
Smokeless
Boiler Number
Regular
Senes. . Boiler
Number .
Steam Rating
Water Bating
Grate Area
Flow and
. Return 2 Each Inches.
of Boiler Inches
Depth Inches
Chimney Chimney
Area Height
Inches
Feet
20 Series Water Line 38 Inches--Height of Flow 43 Inches
25
700 1.150
3.88
26
900 1,500
4.85
27
1.100
1,850
5.82
28
1,300
2,200
6.80
3 3
35 42
3399i/#2
. 8x<2 12x12
43
49
39$
12x12
3
56 -
39
12x12
40 40 40
40
30 Series Water Line 43 Inches--Height of Flow 48 Inches
530 630
35 1,200 36 . 1,600
2,000 2,650
5.83 7.29
4 4
35 42
54V, 54ft
12x12 12x12
40 40
730 830
37
2,000
3,300 , 8.75
38
2,400 . 4,000
10.21
4 4
49 56
5544>$A
12x12 12x12
40 40
930
39
2,800
4,650
11.67
4 63
12x16
40
1030 1130
310 311 *
3,200 3,600
5,300 6,000
13.13 14.59
4 4
70 77
54$ ,
12x16 12x16
45 45
1230
312
4,000
6,650
16.05
4
84
54<h -
16x16
45
640
740 840 940 1040
1140 1240
1340
1440 1540 1640
1740 1840
40 Series Water Line 47 Inches--Height of Flow 54 Inches
46 47 48 49 410 411
412 413 414 415 , 416 417 418
.
2,500 3,200
3,900 4,600
5,300
6,000 6,700
7,400 8,100 8,800
. 9,500 10,200 10.900
4.150 5,300
6,450 7,600 8,750 9,900 11,100
12,250
13,400 14,550 15,700 16,850
18,000
9.72 11.66 13,60
15.54 17.48 19.43 21.35
23.32 25.27 27.22
29.17 31.12
33.07
5 42 5 49 5 56 5 63 5 70 5 77 5. 84 5 91 5 98 5 105 5 112 5 .119 *5 - 126
79 79 79 79 79 79 79 79 79 79 79 79
. 79
12x16 12x16 16x16 16x20 . 16x20
20x20 20x20 24x24 24x24 24x28 28x28 28x28 28x32
50 50
50 55 55 55 60
65 -65 65
70
70 70
*One additional 4-in. flow. **Two additional 4-in. flows. Double series boilers 2,600 to 22,300 sq. ft.
387