Boilers and Radiators Continental Heater Corporation Dunkirk, N. Y. MANUFACTURERS OF CAST IRON BOILERS AND RADIATORS Boiler No. 4 5 6 7 8 CONTENTO BOILERS Steam Rating Sq. Ft. 240 320 400 500 600 Water Rating Sq. Ft. 400 535 670 825 990 Overall Length Inches 20 23V, 27 30>/. 34 Grate Area Sq.Ft. .94 1.22 1.55 1.92 2.25 . CONTINENTAL SQUARE BOILERS Boiler No. 74 75 76 77 78 79 Steam Rating Sq.Ft. 450 650 825 1000 1175 1300 Water Overall Rating - Length Sq.Ft. `Inches 750 1075 1375 1600 1925 2150 24 28 32 37 41 46 Grate Area Sq. Ft. 1.5 2.0 2.5 3.0 3.5 4.0 Contento For installation on same floor with radiators or in basement Water line 46 in. Flow tapping 56 in. Four. five, six and seven section have 2--2in. flow and returns; eight and nine section have 3-2M inflow and returns. . Continental Square. Water tube design. Burns any kind of fuel CONTINENTAL RADIATORS Each individual section is rigidly tested and inspected. After assembly each radiator receives a second test and inspection. Continental radiators are dependable. CONTINENTAL CLASSIC RADIATORS Width wFour Tube.................. Sq. Ft. per Section.... rSix Tube.. ............... Sq. Ft. per Section__ 38" 4/4 38" 6 32' 3'/2 32' 5 26" 23/4 26" 4 20" 2>/4 m'23" 20" 3 VAEight Tube................. 12" 20" 17"\ 14* Sq. Ft. per Section___ 3 Classic in Name Classic in Appearance CONTINENTAL PLAIN RADIATION Width One Column............... 5" 38" 32* 26" 23" 20" Two Column.............. 1W 38" 32" 26" 23" 20" Three Column........... 9* - 38" 32" 26" 22" 18" Four Column ............ \\%w 38* 32" 26" 22" 18" Five Column.............. 13V,' 22" 18" 14" Wall Radiators are assembled with screw nipples 386 Continental Heater Corporation Boilers and Radiators Continental Low Water Line Boilers Smokeless and Regular Types Interior View Superior Features Extremely low water line, that of largest boiler being only 47 inches. Fired short way of grates, making firing easy. Water tubes in fire box come in direct contact with flames. Good cir culation within boiler and large volume of water insures steady water line on fan systems. Made in regular and smokeless types. Will burn any kind of fuel including oil. Every boiler set up and rigidly tested before ship* ment. CONTINENTAL LOW WATER LINE BOILER DATA {Ratings.have never been changed) Smokeless Boiler Number Regular Senes. . Boiler Number . Steam Rating Water Bating Grate Area Flow and . Return 2 Each Inches. of Boiler Inches Depth Inches Chimney Chimney Area Height Inches Feet 20 Series Water Line 38 Inches--Height of Flow 43 Inches 25 700 1.150 3.88 26 900 1,500 4.85 27 1.100 1,850 5.82 28 1,300 2,200 6.80 3 3 35 42 3399i/#2 . 8x<2 12x12 43 49 39$ 12x12 3 56 - 39 12x12 40 40 40 40 30 Series Water Line 43 Inches--Height of Flow 48 Inches 530 630 35 1,200 36 . 1,600 2,000 2,650 5.83 7.29 4 4 35 42 54V, 54ft 12x12 12x12 40 40 730 830 37 2,000 3,300 , 8.75 38 2,400 . 4,000 10.21 4 4 49 56 5544>$A 12x12 12x12 40 40 930 39 2,800 4,650 11.67 4 63 12x16 40 1030 1130 310 311 * 3,200 3,600 5,300 6,000 13.13 14.59 4 4 70 77 54$ , 12x16 12x16 45 45 1230 312 4,000 6,650 16.05 4 84 54<h - 16x16 45 640 740 840 940 1040 1140 1240 1340 1440 1540 1640 1740 1840 40 Series Water Line 47 Inches--Height of Flow 54 Inches 46 47 48 49 410 411 412 413 414 415 , 416 417 418 . 2,500 3,200 3,900 4,600 5,300 6,000 6,700 7,400 8,100 8,800 . 9,500 10,200 10.900 4.150 5,300 6,450 7,600 8,750 9,900 11,100 12,250 13,400 14,550 15,700 16,850 18,000 9.72 11.66 13,60 15.54 17.48 19.43 21.35 23.32 25.27 27.22 29.17 31.12 33.07 5 42 5 49 5 56 5 63 5 70 5 77 5. 84 5 91 5 98 5 105 5 112 5 .119 *5 - 126 79 79 79 79 79 79 79 79 79 79 79 79 . 79 12x16 12x16 16x16 16x20 . 16x20 20x20 20x20 24x24 24x24 24x28 28x28 28x28 28x32 50 50 50 55 55 55 60 65 -65 65 70 70 70 *One additional 4-in. flow. **Two additional 4-in. flows. Double series boilers 2,600 to 22,300 sq. ft. 387