Document vV6QwBVLwnLEXg1nwZ4kqrbmw

DATE: SUBJECT: FROM: THRU: TO: UNITED STATES ENVIRONMENTAL PROTECTION AGENCY REGIONS 77 WEST JACKSON BOULEVARD CHICAGO, ILLINOIS 60604 OCT O8 2019 CLEAN AIR ACT INSPECTION REPORT Sims Metal Management, Chicago, Illinois Vicky Mei, Environmental Engineer AECAB (IL/IN) Nathan Frank, Section Chief AECAB (IL/IN) File BASIC INFORMATION Facility Name: Sims Metal Management Facility Location: 2500 S. Paulina Street, Chicago, Illinois Date of Inspection: September 20, 2019 EPA Inspector: 1. Vicky Mei, Environmental Engineer Other Attendees 1. Debbie Hays, Central Region SHEC Director, Sims Metal Management (Sims) 2. Richard Trzupek, Principal Consultant, Trinity Consultants 3. David Dempsy, Managing Consultant, Trinity Consultants 4. George Malamis, General Manager, Sims 5. Sam Flores, Plant Manager, Sims 6. Eric Ehlers, Director of Field Operations, Mostardi-Platt 7. Jeremy Carlson, Mostardi-Platt 8. Dan Kossack, Mostardi-Platt 9. Jeff Gross, Mostardi-Platt 10. Rick Sollars, Mostardi-Platt Contact Email Address: Debbie.Hays@simsmm.com Purpose of Inspection: Emissions Test Observation Facility Type: Metal Shredding and Recycling Arrival Time: 7:45 AM Departure Time: 3:30 PM Inspection Type: D Unannounced Inspection l3l Announced Inspection OPENING CONFERENCE l3l Credentials Presented l3l CBI warning to facility provided The following information was obtained verbally from Sims, Trinity Consultants, or MostardiPlatt staff unless otherwise noted. Process Description: Sims utilizes a harnmerrnill shredder to shred sheet iron and end-of-life vehicles (ELV) and sort the shredded metals for recycling. For the purposes of the stack test required by Sims Administrative Compliance Order, dated December 17, 2018, Sims installed a temporary enclosure around the under-mill oscillator (UMO) with overlapping rubber sheeting around the UMO, metal sheeting above the mill, and vacuum pulling emissions through the enclosure to ducting with emission testing probes for sample collection and monitoring of particulate matter, volatile organic compounds (VOC), and metals from the mill. Since the initial test on September 5, 2019, Sims added sheeting to an opening along the foundation wall on the south side of the shredder. Any captured particles and objects in the air were discharged through the ducting to a pod with openings that were covered by expanded metal, a mesh filter, and water from a misting hose on the outside of the exhaust point. The fan was operated at 50 hertz during all three stack test runs. Staff Inten,iew: Sampling and testing occasionally stopped between about zero to three times per run to clean out and/or replace the probes when particles clogged the probes. 300 tons of ELV and sheet metal were consumed during each run. The total hydrocarbon (THC) ranges were very rough estimates, provided at a glance by Mostardi-Platt staff. Page 2 of 4 Run Estimated start time Estimated end time Estimated THC range Estimated flow rate #1 8:54 AM 10:37 AM 20 - 200 ppm, with a I000+ ppm spike near the end of the run 40,000 - 45,000 standard cubic feet ner minute (scfm) #2 11:27AM 1:14 PM 17 - 180 ppm 47,000 scfm #3 1:45 PM 3:29PM Sporadic spikes in emissions occurred during run. 47,000 scfm TOUR INFORMATION EPA toured the facility: Yes Data Collected aud Ohservatious: Visible emissions and emissions imaged via the FLIR camera were seen during all three runs. A significant spike in THC concentration occurred near the end of Run #1, as seen in Video #12 (see Appendix A). During Run #2, significantly more emissions were uncaptured, as seen via FLIR camera, (see Videos #13-21 of Appendix A). Videos captured during Run #3 showed sporadic spikes in emissions imaged via the FLIR camera. During Run #3, the wind was blowing west, and the southeast view of the mill provided a better vantage point for observations. Photos and/or Videos: were taken during the inspection. Field Measurements: were taken during this inspection. Field Measurements, using EPA Methods 1, 2, 3, 4, 5, 25, and 29 were performed by Mostardi Platt technicians during the course of the emissions testing. SIGNATURES Report Author: Section Chief: Page 3 of 4 Facility Name: Sims Metal Management Facility Location: 2500 S. Paulina Street, Chicago, Illinois Date of Inspection: September 20, 2019 APPENDICES AND ATTACHMENTS 1. Appendix A: Digital Image Log Page 4 of 4 Facility Name: Sims Metal Management Facility Location: 2500 S. Paulina Street, Chicago, Illinois Date of Inspection: September 20, 2019 APPENDIX A: DIGITAL IMAGE LOG l. Inspector Name: Vickv Mei 3. Company/Facility Name: Sims Metal Management 5. Number of Images: 38 2. Date(s) oflnspection: Seotember 20, 2019 4. Address, City, State: 2500 S. Paulina Street, Chicago, Illinois 6. Archival Record Location: Two USBs, labelled "Sims 09/20/2019 FLIR videos(]) and photos" and "Sims 09/20/2019 FLIR videos(2)" Digital Photos Image Number File Name Date and Time (CST) Run 9/20/2019 1 P920000 l .JPG 9:32AM #1 9/20/2019 2 P9200002.JPG 9:33 AM #1 9/20/2019 3 P9200003.JPG 9:33 AM #1 9/20/2019 4 P9200004.JPG 9:33 AM #1 Descriotion of Image Visible emissions from top of mill (northwest view); photo taken in between FLIR camera videos #5 and #6. Visible emission from the middle sorter chute (northwest view). Visible emission from the middle sorter chute (northwest view). Visible emissions from top of mill (northwest view). FLIR Videos Incorrect date and ti.me camera settuw but accurate reIali.ve time increments* Image Number 1 2 File Name MOV 2558.mn4 MOV 2559.mo4 3 MOV 2560.mo4 4 MOV 2561.mn4 5 MOV 2562.mn4 Date and Time (CST) * Run Descriotion of lma!le 12/31/1999 23:42 #1 Prematurelv ended video (east view). 1/1/2000 0:37 #1 Entire orocess (east view). Prematurely ended video; digital video only; inlet 1/1/2000 feed to mill (east view); some emissions and 0:41 #1 oeriodic VOC olumes. 1/1/2000 Inlet feed to mill (east view); some emissions and 0:45 #1 oeriodic VOC olumes. 1/1/2000 Inlet feed to mill (east view); some emissions and 0:56 #1 neriodic VOC nlumes. Appendices Page 1 of 3 Facility Name: Sims Metal Management Facility Location: 2500 S. Paulina Street, Chicago, Illinois Date of Inspection: September 20, 2019 Top of mill enclosure (northwest view); periodic 1/112000 VOC plumes from mill; visible steam from middle 6 MOV 2563.mn4 1 :04 #1 sorter chute onening. 1/1/2000 7 MOV 2564.mn4 1 :13 #1 Ton of mill enclosure (northwest view). 1/1/2000 8 MOV 2565.mn4 1:26 #] Ton of mill enclosure (northwest view). Top of mill enclosure (northwest view); with 1/1/2000 inverted polarity auto camera mode and high- 9 MOV 2566.mn4 1:29 #1 sensitivity mode. 1/1/2000 10 MOV 2567.mn4 1:31 #1 Ton of mill enclosure <northwest view). Top of mill enclosure (northwest view); 1/1/2000 alternating between auto camera mode and high- 11 MOV 2568.mn4 1:37 #1 sensitivitv mode. End of sorter chute; emissions seen; during near 1/1/2000 the end of Run #1 and may be during the 1000+ 12 MOV 2569.mn4 1:47 #1 nnm THC snike. 1/1/2000 Top of mill (northeast view); significants amounts 13 MOV 2570.mn4 3:12 #2 of emissions seen. 1/1/2000 Top of mill (northeast view); significants amounts 14 MOV 2571.mn4 3:29 #2 of emissions seen. 1/1/2000 Top of mill (northeast view); significants amounts 15 MOV 2572.mn4 3:37 #2 of emissions seen. 1/1/2000 16 MOV 2573.mn4 3:47 #2 Top of mill (northwest view). 1/1/2000 Top of mill (northwest view); significant amounts 17 MOV 2574.mn4 3:51 #2 of emissions seen. 1/1/2000 18 MOV 2575.mn4 4:02 #2 Top of mill (northwest view); emissions seen. 1/1/2000 19 MOV 2576.mn4 4:15 #2 Ton of mill (northeast view); emissions seen. 1/1/2000 20 MOV 2577.mn4 4:20 #2 Ton of mill (northeast view); emissions seen. 1/1/2000 21 MOV 2578.mn4 4:26 #2 Ton of mill (northeast view); emissions seen. 1/1/2000 Pod discharge point, sorter chutes, top of mill (east 22 MOV 2579.mn4 4:29 #2 view). 1/1/2000 23 MOV 2580.mn4 4:39 #2 Inlet feed to mill (east view); neriodic emissions. 1/1/2000 24 MOV 2581.mn4 5:38 #3 Inlet feed to mill (east view). 1/1/2000 25 MOV 2582.mn4 5:42 #3 Ton of mill and sorter chutes (northeast view). Appendices Page 2 of 3 Facility Name: Sims Metal Management Facility Location: 2500 S. Paulina Street, Chicago, Illinois Date of Inspection: September 20, 2019 26 27 28 29 30 . 31 32 33 34 MOV 2583.mn4 MOV 2584.mo4 MOV 2585.mn4 MOV 2586.mn4 MOV 2587.mo4 MOV 2588.mn4 MOV 2589.mo4 MOV 2590.mn4 MOY 2591.mn4 1/1/2000 5:44 1/1/2000 5:52 1/1/2000 5:58 1/1/2000 6:03 1/1/2000 6:10 1/1/2000 6:13 1/1/2000 6:17 1/1/2000 6:24 1/1/2000 6:29 Top of mill and sorter chutes (northeast view from #3 further south). #3 Too of mill (northwest view). Top of mill (northwest view); wind was blowing #3 west; noor view. Top of mill, sorter chutes, sorted metals outlets (northwest view); wind was blowing west; poor #3 view. #3 Accidental blank video with lens cao on. #3 Too of mill and sorter chutes (northeast view). Pod discharge point, sorter chutes, top of mill (east #3 view). Inlet chute to mill (southeast view); wind blowing #3 west; emissions seen. Inlet chute to mill (southeast view); wind blowing #3 west; emissions seen. Appendices Page 3 of 3