Document vV5jK0x6wvozjkMnxDnz9Yv7E

276 CHAPTER 18 1965 Guide And Data Book AIR REQUIRE) FOR COMBUSTION Air requirements for combustion of solid and liquid fuels are ordinarily expressed in'pounds. On the other hand, simi lar requirements for gaseous fuels are usually stated on a cubic foot basis. For solid and. gaseous fuels this method of treatment corresponds to. the standards of measurement commonly employed bythesetwo industries. -The weight of-air required for stoichiometric combustion per pound of:6olid or-liquid fuel may be calculated after substitution of the proper percentages by weight of the vari ous elements obtained from an-ultimate analysis of the fuel in Equation 2. For'gaseous fuels see Equation 3 for volume of air required. Solid or Liquid Fuel*: - Pounds air required per pound fuel Table 6 .... Approximate Air Requirements for * - Stoichiometric Combustion of Fuels4 Type 0/ Ak Jtcqwcred for Stolduoamtne Coabettion Af^roovote Lb per U* Cu Ft per Unit* "%"' Fuel Feel (twplwiu Solid Btu per lb Btu per lb X 0.00073 X 0.0097 liquid Btu per lb Btu per lb X 0.00071 X 06094 Gas Btu per lb Btu per cu ft ' X 0.00067 X 0.0089 3 3 5 Fuels contain- ing more than 30% water Results low for gasoline and kerosine Gases' of 300` Btu per cu ft or less For Oateou* Fuel*: ' - 4 VUuea Is table takes (ram pm *7# ct Gamut Furli, IMS. puhlahod by Amoiean Goa Anodati**. a Usita for --^ sad fuel* is pounds, (or rax is ftthk (ooC Cubic feet air required per cubic foot gas, ` - 2.39 (CO '+ H,) + 9.53 CH, + 16.68 C*H, + 2382 C*H + 30.97 CHU + 11.91 C*H + 1469 C*H< + 7.15.H*S - 4.78 O* +.30.47 Uluminants (3) Gaseous fuels may contain a wide variety of components classified as UlttmiiumU, which are not separated by the usual methods of gas analysis. The principal illuminants in addition to'ethylene (CsHO and acetylene (C*H*) which are included in Equation 3, with the air required per cubic foot of gas are: propylene, 21.44; butylene, 2888; pentene, 35.73; benzene, 35.73; toluene, 42.88; and xylene, 50.02. Since toluene and xylene are normally scrubbed from the gas* before distribution, they may be disregarded in computing air required for-a fuel gas. An approximate value of 30.47 (as shown in Equation 3) may, therefore, be employed. If ethylene and acetylene are included as iUvminantt, it is sug-. gested that the value 19.65 be used. If it is desired to make the gas calculations on a weight basis the equation is expressed as follows: Pounds air required per pound fuel - 2.47 CO + 3464 H, + 1767 CH + 16.12 C*H, + 15.70 C.H, -f 15.49 CH,, + 1360 C*H, + 1481 C*Hi + 6.10 H*S -- 462 O* (4) Where approximate results only are desired, values ap pearing in Table 6 may be substituted for Equations 2, 3, and 4; or the air-required for perfect combustion may be. estimated by assuming that 0.9' cu ft air is required per 100 Btu-of fueL- , Where extreme precision.is involved it is suggested that the reader refer to sdentific literature published on the sub ject of combustion and related topics by the various indus tries concerned.'If approximate values for theoretical air requirements suffice, or if complete information on the fud ' is not available, the following values should also be found hdpful: | 1. Solid FueL (Pounds air per pound fuel): Anthracite, 96; Semi-Bituminous, 116; Bituminous 106; Lignite 66; Coke 118. 2. Fuel OH (Pounds air per gallon): Commercial Standard No. 1,102.6; No. 2,105.5; No. 5,112; No. 6,1I4.2.1 * - 3. Gasecm* Fuel* (Cubic feet of air per cubic foot): Natural, IOjO; Mixed Natural and Manufactured, 86; Manufactured, 4.7, Propane, 238, Butane, 316. COMBUSTION EFF1GENCY FROM THE. FLUE-GAS ANALYSIS Excess Air A commonly employed index of efficiency of combustion is the relation existing between the amount of air theoreti- pally required for perfect combustion and the amount of air actually supplied. Since the difference between air supplied for combustion and theoretical air required is characterized as excess air, its percentage may be calculated as follows: - Percent excess air Air supplied - Theoretical air\ ^ Theoretical air / ^ - The amount of dry air supplied per pound of fud burned may be obtained from Equation 6 which has reasonable precision for most solid and liquid fuels. Values for CO*, CO pnH N* are percentages by volume from the flue-gas analysis, C is the weight of- carbon burned per pound of fuel, corrected for carbon in the ash. Pounds dry air supplied per pound of fuel -- --364Ni-- (CO, +. CO) * - Because excess dr calculations are almost invariably made from Orsat analysis results,- and theoretical air,requirements are not always known, .another convenient method of ex pressing the relation of Equation 5 is as follows:- 100(0, - CO/2) Percent excess au-NtX ^ _ (Q, _ ^ (7) As measurement standards for gaseous fuels are almost universally expressed in cubic feet, Equation 8 may be used for computing air on a percentage basis for gases. Percentair (U - CCW X 100 7 CO, (8) Fuels ond Combustion 277 Table 7 Approximate Maximum Theoretical (Stotdtio* mctrjc) CO, Values, and CO, Values for Various Fuels with Different Percentages of Excess Air Typo of Fuel Percent CO* ct Gfreo tbkWofldik twetl Air Vaiuos Percent CO* 20% 40% % Anthracite Bituminous Coal No. 1 and 2 Fuel Oil No. 6 Fuel Oil Natural Gas Carburetted Water Gas Coke Oven Gas Gas (Natural and Carburetted Water Gas) Propane Gas (Commercial) Butane Gas (Commercial) 21.0 20.2 18.2 15.0 16.5 12.1 17.2 11.2 15.3 13.9 14.1 17.5 15.0 13.0 16.8 14.4 12.6 15.1 12.9 11.3 12.3 10.5 9.1 13.6 11.6 10.1 9.9 8.4 7.3 14.2 12.1 10.6 9.2 7.8 6.8 12.5 10.5 9.1 11.4 9.6 8.4 11.6 9.8 8.5 where U = ultimate carbon dioxide, percent of flue gases resulting from stoichiometric combustion. COt ** carbon dioxide content of flue gases, percent. P -- dry products from stoichiometric combustion, 'cubic feet per cubic foot of gas burned. A - air theoretically required for complete combustion, cubic feet per cubic foot of gas burned. As the ratio of P/A is approximately 0.9 for most- city, gases, a value of 90 may be substituted for 100(P/A)' in Equation 8 for rough calculation. ! Carbon-hydrogen ratios of different fuels vary consider ably, hence the maximum or ultimate CO, attainable also varies. Theoretical marimnm CO, values may be ^alc-nlateiH from a flue-gas analysis by use of Equation 9. Maximum theoretical % CO, % CO, in flue gas sample X 100 m /O, in same sample\ \) -Approximate maximum CO, values for stoichiometric com bustion of several common types of fuel are shown in Table 7 together with values of CO, that will be attained with different amounts of excess air. Desirable values to be attained in practice depend upon the fuel, the method of firing,' and other considerations. In general, fuels bunted in such as gas, oil, and pulverized coal, can be burned with a lower amount of excess air than fuels burned on grates. To produce heat efficiently by burning any common fuel, a number of basic requirements must be met: (1) adequate heat absorbing surface is necessary in the appliance, (2) heat transfer surfaces must be clean on both fire water or air tides, (3) a minimum amount of excess air must be present, (4) air .employed for combustion and combustible gases must be properly mixed, and (5) flue-gas losses must be reduced to a safe minimum If insufficient heating surface is employed, or if heat trans fer surfaces are covered with soot, ash, or scale, flue losses will ^eraUy be excessive due to the'lakge amount of wennihle b4t escaping to the chimney. Tdo'much excess air dilutes flue gases excessively and increases sensible flue gas loss. On the other hand, a deficiency of excess air will in all' prob ability cause incomplete combustion, and consequent escape of some unburned combustible gases from the appliance. Highest combustion efficiency is obtained when sufficient excess air is supplied and properly mixed with the com bustible gases. Even with appliances connected to an effec tive flue every reasonable precaution should be taken to in sure as complete combustion as possible at all times. This is of vital importance in unvented equipment such as a gas space heater, for example. It is considered good practice to supply from 20 to 50 percent excess air, the exact amount depending on the kind of fuel burned and especially on the type of equipment in which it is utilized. Flue Gas Analysis As radiation, convection, and conduction losses from com mon types of central heating appliances are largely em ployed in heating occupied spaces, flue-gas losses logically become the item of principal concern. Another reason for their importance is the fact that they are usually larger than all other heat losses combined. These important considera tions and others indicate not only the desirability but ab solute necessity of a reasonably accurate method for deter mining flue losses even if only approximate operating efficiencies are to be computed. Customary procedure in arriving at flue-gas losses is to make an analysis of a representative sample of flue gases and to measure their temperature. This information will enable the observer to compute the amount of flue gases produced, the excess air, the actual quantity of air supplied for com bustion, and the flue losses. While the analysis of flue has been well described in several governmental and other scientific publications, the subject is of such importance that it warrants brief repetition here. Carbon dioxide and oxygen content are of principal interest in determining flue losses. Either or both of these values may be employed in such cal culations. While the former constituent is probably most commonly employed, special considerations may make the latter of greater interest. Fortunately, both can be deter mined readily by use of an Orsat gas analysis apparatus, a device of reasonably simple construction and design. For field testing and burner adjustment, simple portable devices are available for determining carbon dioxide only. See Chap ter 16 regarding operation of the Orsat apparatus. The weight of dry flue gas per pound of fuel burned is widely used in combustion loss calculations. For 6olid fuels this item may be determined by application of Equation 10. Pounds dry flue gas per pound fuel lico, + 80, + 7(CO + Nt) 3(COi + CO) X C (10) Values for CO*, O*, CO, and N, are percentages by volume from the flue gas analysis, and C is the weight of carbon burned per pound of fuel, corrected for carbon in the Total dry gas volumes of flue gases resulting from the combustion of one cubic foot of gaseous fuels for various percentages of CO, may be determined by application of Equation 11: Cubic feet dry flue gases per cubic foot fuel gas Cubic feet CO* produced per cubic foot of gas burned X 100 (11) Percent CO* by analysis After obtaining the quantity of flue gases from Equations'