Document vV5a2gKKYpvE39rKEav7qo43Z
To:
S. C. Hillman
From: J. R. Ganc Date: November 30, 1990
VCM CONCENTRATIONS FOR DIFFERENT SOURCES
The
following
figures
represent
the
the
VCM
concentrations in and around our plant as determined by
the air dispersion models I have been running recently.
The units on the contours are ug/m3, and the coordinates
of the X and Y axis are in meters. The table represents
the highest concentrations found at the rececptors
located at 10 intervals around the fenceline.
The
fenceline marked on the graphs represents the real estate
that we specifically have fenced or otherwise blocked off
(e.g. the fire pond and the front parking lot do not fall
within the fenceline). Mississippi highway no. 25 is
about 130 meters north of the north boundary.
These graphs represent the concentrations of VCM that
result when the plant is producing slurry that has a VCM
concentration of 100 ppm.
These model runs are also
different from those performed by Scott Environmental;
I fixed some mistakes in their original work and modified
the treatment of the ponds and the sphere into what I
thought was a more representative form.
ph R. Ganc cc: RBN, FGJ