Document vV2goz2gn9KV8vjka06XYGa1Z

Burner {Oil), Accessories Preferred Utilities Manufacturing Corp. 33 WEST 60th STREET NEW YORK, N. Y. BOSTON SALES OFFICE 839 BEACON ST. The "PREFERRED UTILITIES" are Air Conditioning Controls Anti-Hum Valve Anti-Syphon Valve Bake Ovens CO, Analyzer Combustion Chambers Commercial Ranges Commercial Range Burner Condensate Control Double Tapped Bushings Draft-A-J ustors Draft Gauges Economizer Flame Mirror Floatless Low Water Cut-Off Flush Fill Bores Foot Valves Heavy Fuel Oil Metering Valve Heavy Fuel Oil Strainer Heavy Fuel Oil Thermometers Heavy Fuel Oil Valve Ignition Torches Industrial Furnace Insulating Cement Joint Seal Multiple Boiler Control Nitralloy Nozzles Observation Ports Oil Pipe Dope 100% Automatic Damper Pressure and Vacuum Gauges Recording Thermometers Refractories and Cements Smoke Control Stack Thermometers Steam Line Oil Heaters Suction Line Extension Flange Suction Line Valves Syphon Breakers Tank Sludge and Transfer Pump Three Wire Armored Cable Vent Protectors Vented Fill Caps Water Level Control Yacht Hot Water Heater PREFERRED DRAFT-A-JUSTORS Listed as standard by the Underwriters' Laboratories, Inc. Hundreds of thousands in use. Holds the draft constant in the fire box. Scientific draft control for the smallest to the largest jobs. Stove, domestic, Small Draft A-Juster and commercial sizes from 4 in. to 24 in. in diameter. Industrial sizes from 30 ft x 30 ft to 5 ft X 12 ft. Large Draft A-Jusler THE PREFERRED FLOATLESS LOW WATER CUT-OFF Listed as standard by The Underwriters' Laboratories, Inc. Conforms to A.S.M.E. Boiler Construction Code. Law Water Electrode Assembly FEATURES OF THE PREFERRED FLOATLESS LOW WATER CUT-OFF Unaffected By Sludge. Fully Electric. Positive Snap Action. Simple To Install. Priced Right. No Parts To Replace After It Has Acted. Instantly Returns Automatic Heating Equipment To Operation When Safe Water Line Is Restored. 970 Cooling Towers The Cooling Tower Company, Inc. 15 John Street, New York, N. Y. Representatives in Principal Cities Manufacturers of Atmospheric Cooling Towers, Spracoolers, Forced Draft and Induced Draft Cooling Towers, Spray Nozzle Cooling Systems, Spirodome and Impact Type Spray Nozzles, Louvered Spray Fences, and Indoor Type Cooling Towers. Atmospheric Cooling Towers Mechanical Draft Cooling Towers The amount of water circulated per square foot of active horizon tal area (area of one deck) affects the final temperature to which an atmospheric cooling tower will cool. Frame--Steel or timber diagonally braced for wind thrust, with load safety factor of 4. Our towers have passed the acid test of all recent cyclones. We fabricate, erect, and guarantee forced and induced draft cooling towers of any capacity from one ton up, for in door or outdoor use. Special Balke type filling provides for thorough mixing of air and water, resulting in efficient cooling. Spray Nozzle Systems Walkway and Ladder--Provide easy access to distributors. " Distributing System--Sprinkler type of patented construction. Guaranteed free from plugging. Secondary Distributors--Prevent un necessary icing of tower during winter use. Decks--Patented sections; rigid align ment; warping or distortion prevented; uniform distribution of water; properly spaced. .Louvres--Wood or corrugated metal. Securely fastented; rigid construction. Collecting Basin--8 in. deep, extends 1 ft outside tower footings; fitted with discharge flange, suction head and strainer. We make two types of spray noz zles--Impact spray nozzle which throws a flat, fan-shaped spray cloud--Spiro dome spray nozzle producing a high conical spray cloud suitable for general installations. Either type may fit requirements and our Engineering Department will submit proposals covering the best type for a particular purpose. Outstanding features of our spray pond systems are: Lumber--California redwood or Louisiana cypress. Substructure--Designed and furnished on request. (1) Non-clogging nozzles. (2) Freedom from interruption of opera tion. (3) Automatic drain and flushout valve. Guarantee--A curve guarantee for our standard atmospheric towers to show temperature reductions effected at various loadings per square foot of active horizon tal area. All curves based on wet bulb tem peratures taken with sling psychrometer. (4) Well designed spray fence for protec tion against spray dirt. Indoor Cooling Towers Type A Spracoolers For use where cost will not permit a standard deck type cooling tower and space will not allow a spray pond to be installed. Wood or steel con struction, light in weight, equipped with an efficient nozzle distributing system. For indoor Installations of one to forty tons capacity. Available in commercial type or quiet rating. Steel shell, Balke type wood filling, drift eliminators, float valve, access door. Easy to erect, economi cal to operate. Low pumping head. Ship ped complete or knocked down. 971 /