ASBESTOS EXPOSURE What are the risks of low-level asbestos exposure? Perhaps it's time policy makers investigated the evidence before committing more time and money to removal efforts. Introduction By William E. Bailey he core issue in any discussion of wards the potential risk factor for much Tasbestos abatement is its necessity. lower level exposures. The Environmental Protection Cetrulo has been active in asbestos litiga Agency's (EPA) regulations and stitoandsainrdcse shortly after he joined Bums and are driving the current flurry oLf eavcintisvoitny in 1976. In fact, I believe it was as among property owners and managers (and a result of my suggestion to him that he their lawyers and bankers) to determine explore this fast-growing area of legal exper which of their buildings fall within the tise. For the past several years, he has been regulations and must comply. the Asbestos Claims Facility's coordinating Larry Cetrulo, a partner in the Boston firm counsel in Boston. More recently, he has of Bums and Levinson, contends that been drawn into the property damage claims medical, scientific and epidemiological data area and the new wave of litigation that do not support the regulations and that we poses a m^jor threat to asbestos product are hell bent to spend billions of dollars manufacturers at a time when many are ex removing asbestos in public and private hausting their available insurance coverages buildings where the actual risk factors for in bodily injury cases. occupants and visitors is so negligible as to Cetrulo's article will encourage some and be virtually zero. Cetrulo bases his argu infuriate others. He has struck a sensitive ments on recent studies comparing the nerve with his arguments and his conclu known data on the carcinogenicity of various sions. AI will continue to provide a forum asbestos fiber types in occupational settings for all sides of all issues, including "Is this and then attempting to extrapolate back all much ado about nothing?" For example, if a contractor has completed 50 percent of a project, bat has been paid 75 percent of the con tract price, there would likely be a deficiency in the contract balance if the contractor defaults. However, if the owner has paid the appropriate amount for the performance of the work (50 percent of the contract price, in this case), it's less likely there will be a deficiency. In determining whether a deficiency exists, the owner has to take into account the cost of the bond premium and the added cost charged by the contractor for having posted collateral with the surety company. With respect to material and labor payment bonds, the principles of analysis are similar. If the contractor has performed work but has not paid his laborers or material suppliers, a deficiency could exist which would require response by the surety com pany. However, there are methods of protecting against such problems. In many states, if a project owner obtains a sworn statement from the contractor with each pay request that all bills for labor and materials have been paid, he may be protected against paying the contractor and then later having to pay for materials and labor for which the contractor has not made payment. The owner could also require the contractor and any suppliers to execute lien waivers in return for progress payments. Since materials do not comprise a large part of an asbestos abatement project con tract price, the likelihood of unpaid material claims is reduced. Also, laborers will generally not work for extended periods without pay. There is another factor involved with asbestos abatement projects that can assist in the analysis of whether bonds are required by an owner or consultant. While many general con struction projects are of long duration, asbestos abatement projects are typic ally of a shorter duration, meaning that performance will be completed more quickly. This can have several important effects. First, the short duration of the project means that a contractor has less chance of "getting into trouble" financially on the proj ect. Furthermore, the short duration of the project means that there is less time for price escalations in labor and/or materials. Often, the increase in the cost to complete a project upon a contractor s defaulting is attribut able to price increases that have DECEMBER--ASBESTOS ISSUES SB occurred within the prolonged period ' is no fixed contract price other than of time that elapsed from the original the cost of labor and materials per signing of the contract and beginning unit of work performed, the penal; of performance of the work to the sum of the bond cannot be readily date of default. determined. It would be difficult'in In addition, it must be recognized many circumstances to obtain a bond that many asbestos abatement proj oh such a project. Although the unit ects are performed on a time and price of work can increase, the loss to materials basis. Since payment is only: the owner cannot be calculated, since made for work that has been per the number of units has not been formed and materials that have been ` agreed upon. purchased and placed upon the job, . Traditions die slowly. The require the utility of a bond in such circum ment of performance and payment stances is questionable. Where there (eonttniMd on pago 64) CIRCLE READER SERVICE CARD NO. 4 41 ALCOAO 000007944 By Lawrence 6. Cetrulo, John B. Savoca and Randolph L. Smith he question of whether low-level in the "EPA Study of Asbestos- cause lung cancer or mesothelioma. Tasbestos exposure, such as the Containing Materials in Public exposure encountered by occu Buildings--A Report to Congress," US pants of asbestos-containing buildingsE,PA (February 1988): Numerous studies have been under taken in an effort to determine the relative carcinogenicity of different presents a material risk of causing "No safe threshold has been asbestos fiber sizes. There is now asbestos-related disease has become established for asbestos. Effects at low scientific evidence to suggest that a major legal and public policy issue. levels of non-occupational exposure long, thin asbestos fibers present the The view that there is no known have been estimated by extrapolation greatest risk of producing canter, threshold level for asbestos exposure from higher levels although the validity with shorter fibers being less, or not below which disease will not occur of this approach has not been em at all, carcinogenic. has, to date, dominated public debate pirically demonstrated."4 A recent editorial by J.M.G Davis. and resulted in a wave of litigation, The EPA's efforts to protect the Ph.D., and Dr. J. Corbett McDonald. regulations and fear. Concern over the public and the environment have been (British Journal of Industrial lack of an informed public policy in understandably focused on public Medicine, August 1988) reviews the this area is now being expressed by health issues rather than on the scientific literature and suggests that the business community ("Scary complex scientific issues involved. the most dangerous fibers are those Asbestos," The Wall Street Journal, However, since the Asbestos Health with a length greater than eight Oct. 12, 1987, and "Why Throw Update was released, a great deal of microns and a diameter of less than Money at Asbestos?" Fortune, June 6, literature has been published on the .25 microns. Davis reports that fibers 1988). medical, scientific and public policy less than five microns in length may Central to the current debate are issues involved. It is important to be innocuous in lung tissue. This questions of whether all asbestos identify and highlight some of this finding is significant, since the great fiber types are capable of causing recent scientific and medical informa majority of fibers normally found in disease at low exposure levels and whether risk of disease at low ex posure levels can be extrapolated validly from epidemiologic data for It may be impossible to prove conclusively that at low occupationally exposed populations. The genesis of the debate is found in the 1985 EPA report "Airborne Asbestos Health Assessment Update," leveis asbestos exposure does not create any increased risk of cancer." by William J. Nicholson, Ph.D. The Update contained two critical find ings including, "Animal studies confirm the human epidemiological tion to hopefully encourage further ambient air, both indoors and out results and indicate that all major study and debate on these crucial doors, are less than five microns in asbestos varieties produce lung issues. length. cancer and mesothelioma, with only Fiber type is also thought by some limited differences in carcinogenic SIGNIFICANCE OF FIBER SIZE experts to be a significant factor in potency," and "Extrapolations of AND TYPE the carcinogenicity of asbestos. It has risks of asbestos cancers for occupa-. Prior to the introduction of strin been suggested that the propensity of tional circumstances can be made, gent safety standards for occupational a particular fiber type to be inhaled although numerical estimates in a exposure to asbestos dust, asbestos and retained in the lung is related to specific exposure circumstance have workers in some industries and job the ability of the fiber to produce a large (approximately tenfold) categories were at times exposed to cancer. The two major asbestos fiber uncertainty."1 very high levels of airborne asbestos types, serpentine and amphibole. may Relying in part on the Update, the fibers. It is now known that this type differ markedly in their propensity to EPA states in the preamble to its final of high-level occupational exposure be inhaled and retained in the lung. Asbestos Hazard Emergency Act can cause asbestosis, lung cancer (in Serpentine asbestos, such as chryso- (AHERA) rule that its analysis of risk smokers) and mesothelioma. It is tile, is characterized by long, silky, ".. shows that asbestos in schools widely accepted, however, that low- curly fibers. The aerodynamic proper could present a risk of concern and level exposure to asbestos, such as ties of these fibers may prevent them that the measures required by this building occupant exposure, does not from being inhaled deep into the rule are necessary to protect the cause asbestosis. The current issue of periphery of the lung. Furthermore, public and the environment."2 The scientific and legal debate is whether the failure of chrvsotile to persist in EPA also stated, "With respect to the such low-level asbestos exposure the lung may be due to its chemical potency of asbestos, EPA has decided presents a material risk of producing properties which allow the fibers to that for the purposes of this rule, lung cancer or mesothelioma. There be readily broken down into short there is no need to resolve the is now a growing body of medical fibrils and removed from the lung by divergence of opinion.''3 literature that suggests that different the bronchial cilia or by enzymatic The EPA's position on risk assess asbestos fiber sizes and fiber types digestion by the macrophages. ment has recently been summarized have vastly different potentials to In contrast, amphibole asbestos. ALCOAO 000007945 ASBESTOS ISSUES 88--DECEMBER Shelburne Laboratories, Inc. Bulk, Air, Water Testing Silica Testing Transmission Electron Microscopy Scanning Electron Microscopy X-Ray Diffraction X-Ray Spectrometry Light Microscopy For Further Information Contact: Dr. Robert J. Emerson, President or Lucie Jean, Laboratory Manager 802-985-3379 P.O. Box 458 Falls Road Shelburne Vermont 05482 NIOSH PAT Tests EPA Round Robin Accreditation: AIHA, EPA Serving Clients Across the, U.S. Member: NAC/ACIL* ASTM, AALA CIRCLE READER SERVICE CARD NO.~io5 Insurance & Risk Management for the Abatement and Environmental Industry True Occurrence Coverage Commercial General Liability via Best Rated nationally licensed insurer. Asbestos Special Liability via Risk Retention Group company federally qualified in all 50 states. Both programs reinsured by A+ Best Rated U.S. insurers & Lloyds, London. CGL limits to $5,000,000 per occurrence. ASL limits to $5,000,000 per occurrence. .. Treasury-Listed Bonding Contact: Barry Smith Carol Leos Mark Mangum DONOVAN & BAKER, INC 440 Louisiana, Suite 2110 Houston, TX 77002 (713) 224-5551 (IAX) .(713) 223-2615 CIRCLE READER SERVICE CARD NO.64 ALCOAO000007946 such as crocidolite, is characterized by straight, rigid and pointy fibers. The aerodynamic properties of these fibers permit them to be inhaled deep into the periphery of the lung. The rigid pointy structure of amphibole fibers may enable them to penetrate the lung tissue and then pass to the pleura, or lining, of the lung. Finally, the chemical properties of the nique of extrapolation is fraught with difficulties and the validity of theo retical low-level asbestos exposure risk assessments derived from linear extrapolation is a matter of dispute. Extrapolation is a two-step process. First, a dose/response relationship is estimated based upon existing epi demiological data derived from highlevel exposure groups. A dose, response % has been suggested that the propensity of a particular fiber type to be inhaled and retained in the lung is related to the ability of the fiber to produce cancer." amphiboles may enable the fibers to withstand decomposition and be retained in the lung for long periods of time. There is now growing evidence that pure chrysotile does not cause mesothelioma unless at extremely high levels of exposure.5 This evidence includes studies that have found a very low incidence of mesothelioma in workers occupa tionally exposed only to chrysotile. The results of tissue analysis have shown that the lungs of people who have died of mesothelioma contain no more chrysotile than the lungs of people who have died of non-asbestos associated diseases. The data, with respect to fiber type, is significant since the vast majority of asbestos used in buildings in the United States has been chrysotile asbestos. Concern about low-level exposure to asbestos in buildings may be misplaced if low-level exposure to chrysotile does not cause mesothelioma and the asbestos fibers normally found in the ambient air in buildings are too short to cause this disease. RISK ASSESSMENT Presently, the risk of contracting lung cancer or mesothelioma associated with low-level exposure to asbestos can only be assessed indirectly, since low-level exposure is far below the exposure levels at which it has been possible to detect such risks in occu pational settings. Attempts have been made to estimate the risks associated with low-level, non-occupational exposures by extrapolating epidemio logical data from studies of high-level occupational exposures. This tech relationship can be established by demonstrating that increasingly high levels of asbestos exposure are statistically associated with an in creased incidence of cancer. Second, using the dose'response relationship estimated from high-level exposures, the risk for lower exposures is estab lished by linear extrapolation down to the origin. In theory, these extrapola tions should be supported by existing scientific and medical evidence. There are two arguments against the use of linear extrapolation for determining low-level exposure risk. First, there may be deficiencies in the exposure data used to derive a dose/ response relationship for asbestos at high exposure levels. Second, and perhaps more importantly, it is argued that there is no generally accepted theory to justify extrapolation of any dose/response relationship established at high exposure levels back to low exposure levels. These arguments have been used to cast doubt on low exposure level risk assessments derived from extrapola tion. In any event, to the extent that any credibility can be given to lowlevel risk assessments derived from extrapolation, some argue that based upon the most recent data, such risks are extraordinarily low. For example, a recent report by Sir Richard Doll and University of London Professor Julian Feto estimates that a theoretical risk of only one excess death from environmental asbestos exposure occurs per year in the entire United Kingdom.7 8 The concept of an exposure "thresh old" is very important in low-level exposure risk assessment. Linear ex trapolation of low-level risk assumes that there is no safe threshold of asbestos exposure below which there will not be an associated increased risk of cancer. Scientific data has recently been published that suggests there may be a safe threshold for asbestos exposure. With respect to lung cancer, it has long been argued that excess lung cancer associated with asbestos exposure occurs only when the level of asbestos exposure is high enough to produce asbestosis. While this view is still a matter of controversy among experts, a recent study supports an asbestos exposure threshold for lung cancer.9 Although mesothelioma is generally believed to be more likely than lung cancer to be associated with relatively low levels of asbestos exposure, there is some evidence of a threshold of asbestos exposure below which there will not be an increased incidence of mesothelioma. For example. Dr. Andrew Churg has reported that examination of lung tissues of people from the general population and of residents of asbestos mining towns in Canada reveal the presence of signifi cant quantities of asbestos fibers without the production of disease.1" Moreover, a comparison of meso thelioma rates in men and women is revealing on the issue of an exposure threshold for mesothelioma. Although mesothelioma rates have increased in men due to occupational exposure, there has been no corresponding increase in women, suggesting that the background level of mesothelioma has remained constant despite envi ronmental exposure.11 This finding suggests that there is no linear dose'response relationship for mesothelioma at low-level asbestos exposures and that a "safe" threshold for asbestos exposure may exist. PUBLIC POLICY As the focus of public policy regard ing asbestos exposure turns from occupational exposure to exposures in schools and commercial buildings, policy decisions should be made with regard to scientific evidence. The EPA's risk analysis for low-level asbes tos exposure has led to a wave of legislative and administrative findings and regulations pertaining to asbestos in buildings. It is important that this risk analysis consider the most recent scientific studies concerning exposure (continued on pag* 49] DECEMBER-AS8ESTOS ISSUES "88 45 ALCOAO 000007947 vital when abatement procedures are undertaken. The accepted method for measuring these airborne fibers is to draw contaminated air through a filter that traps the asbes tos on its surface. The average fiber concentration is then calculated by dividing the number of trapped fibers by the volume of air pulled through the filter. EQUIPMENT REPORT FOCUS: AIR MONITORING EQUIPMENT, METHODS AND REGULATIONS By William R. Gates A ir monitoring for asbestos is only as good as the organiza- ^^^tion of resulting data and the communication of the results to those affected. This important aspect of the air monitoring program is man dated by OSHA 29 CFR 1926.58, and is the most misunderstood and neglected section of the regulation. This article is the result of my writing many air monitoring manuals for various companies involved in the asbestos abatement industry. A description of the proper use of monitoring equipment is followed by an explanation of proper reporting and recordkeeping Knowing the amount of harmful airborne asbestos in a given area is THE CASSETTE The accepted National Institute for Occupational Safety and Health (NIOSH), the research arm of the Occupational Safety and Health Administration, method of measur ing the asbestos concentration in air is the NIOSH 7400 method. This requires the use of a 25 millimeter diameter filter housed in a threepiece polypropylene holder or cassette. The filter is made of cellulose, the same material that forms the cell walls in plants. Asbestos fibers are impacted on and collected from this cellulose filter. Tb view the fibers in the laboratory, a liquid that dissolves the cellulose material is applied to the filter, then placed under the microscope. The design of the present-day cassette is the result of many years of development with successive improvements brought about by addressing problems found during field use. The addition of the 2-inch extension cowl to help prevent filter damage in open-face sampling and the addition of carbon-treated plastic to help ensure even distribu tion of the fibers are but two of the many improvements. The cowl, though seemingly troublesome, pro tects the filter from the bumps, moisture and generally hostile en vironment of an asbestos abatement area. Carbon is added to render the cassette, especially the cowl, con ductive so as to eliminate the buildup of static electricity. Other wise, static charges would attract asbestos fibers and other airborne debris, causing uneven airflow through the cowl and uneven fiber distribution on the filter. The actual sampling is done "openfaced," meaning that the cassette's end cap is removed, exposing the entire filter surface so that air can be drawn uniformly through it. Uniform fiber distribution is im portant because only 100 small areas, called "fields," are usually ASBESTOS ISSUES '88--DECEMBER ALCOA0000007948 LOW-LEVEL EXPOSURE (continued tram page 45) threshold, fiber size and type and low-dose risk assessment. As is well known in the science of epidemiology, it is often difficult, and sometimes impossible, to prove a negative. It may be impossible to prove conclusively that at low levels asbestos exposure does not create any increased risk of cancer. However, a failure to conclusively prove an exact threshold level of asbestos exposure below which there is no increased risk of cancer may not constitute a rational basis for public policy decisions with such significant economic impact. In their article in the British Journal of Industrial Medicine, Davis and McDonald concluded, "We cannot say, and it may be impossible to prove or disprove that at very low levels of asbestos exposure the cancer risk is zero. ... Rational decisions will depend on questions of cost, benefit and the appreciation of risk. It will be for society, not science, to decide what priority should be given to the re duction of unsubstantiated and undetectable risks, even from such dreaded effects as mesothelioma and lung cancer.'12 Current scientific and medical evidence suggests that the hazards of low-level asbestos exposure may have been overstated. Rational public policy should take into account the new evidence that short asbestos fibers may not be carcinogenic, that pure chrysotile exposure may not produce mesothelioma and that the risk associated with low-level expo sure, if any, may be so low as to be undetectable. Lawrence G. Cetrulo, Esq. is a partner with the law firm of Bums & Levinson, Boston. Cetrulo received his bachelor's degree from Harvard University and his law degree from the Northeastern University School of Law. He is a member of the Boston Bar Association, Massachusetts Bar Association, American Bar Associa tion, Defense Research Institute and the Massachusetts Association of Defense Attorneys. Cetrulo has specialized in product liability, malpractice, general liability insurance coverage and commercial litigation. He has spent the past several years in asbestos-related tort litigation defense work. John B. Savoca is an associate with Bums and Levinson. He received his bachelor's degree from Harvard University and his law degree from Harvard Law School. Savoca special izes in toxic tort defense litigation. Randolph L. Smith received his bachelor's degree from Harvard University and his law degree from The State University of New York at Buffalo School of Law. Smith is an associate with Burns & Levinson and specializes in toxic tort and property damage defense work. He is a member of the Massachusetts and New York State Bar Associations REFERENCES 1. U.S. Environmental Protection Agency. Airborne Asbestos Health Assessment Up date. Special report by William J. Nicholson, Ph.D. 600 8-84-003F. December 1985. 2. U.S. Environmental Protection Agencv. October 30, 1987. 40CFR Part 763. Asbestos-Containing Materials in Schools: Final Rule and Xotice. Fed. Reg. Vol. 32. No. 210, Rules and Regulations, p. 41829. 3. U.S Environmental Protection Agency. October 30, 1987 40CFR Part 763. Asbestos-Containing Materials in Schools: Final Rule and Xotice Fed. Reg. Vol. 52, No. 210. Rules and Regulations, p. 41844. 4. U.S. Environmental Protection Agency February 1988 Asbestos-Containing Materials in Public Buildings. .4 Report to Congress. 5. Churg, A., M.D. "Chrysotile. Tremolite and Malignant Mesothelioma in Man" Chest 93 (March 1988): 621-628 6 Doll, R, Peto. J. "Asbestos. Effects on Health ofExposure to .Asbestos" London Her Majesty's Stationary Office. 1966 7. Weill, H., Hughes, JM. "Asbestos as a Public Health Risk: Disease and Policy. Ann. Rev. Public Health 7(1986). 171-192. 8. Hughes, JM. Weill, H."Asbestos Expr,sureQuantitative Assessment of Risk " American Rev. Respiratory Disease (1986): 5-13. 9. Browne. K.. M.D. "A Threshold for Asbestos-Related Lung Cancer," British Journal of Industrial Medicine 1986 10. Churg, A., M.D "Lung Asbestos Content in Long-Term Residents of a Chrysotile Mining Town," American Rev. Respiratory Disease 134 (1986) 125-127 11. McDonald, JC. "Health Implications of Environmental Health Perspectives." Environmental Health Perspectives 62 (1985): 319-328. 12. Davis, JMG, McDonald, JC. "Lou-Level Exposure to Asbestos: Is There a Cancer Risk?" British Journal of Industrial Medicine (1988): 505-508. OWIKSCRUB Pads Save Time, Save Labor Costs Contractors reach for Qwik Scrub Pads because they're flexible and big, making a cleaning snap of hard-to-reach comers, corrugated decking and other tough surfaces. Because they're strong, they won't disintegrate like the small, wimpy pads. And because they're man-sized, they prevent bruised knuckles. Qwik Scrub's patented protective coating and open weave reduce the danger of glove-bag puncture, increase particle ad hesion, and simplify wash-up. When you're faced with a tough asbestos removaljob, reach for Qwik Scrub--the time and money saver. IgfvVurmUlr Pcsililnaaliftlmr,Patent Pending For mart Information or the name ofyour local distributor, call (3011785-727f. DECEMBER-ASBESTOS ISSUES '88 CIRCLE READER SERVICE CARD NO. 23 69 ALCOAOOOOOQ7949 ADVERTISERS' INDEX FOR FURTHER FREE INFORMATION FROM OUR ADVERTISERS Page No.AdvertiserCircle No. 47 ........... ACTl Glove-bag.......................................... 12 14 .... Aerospace America ........................... 104 61 ... . Aerospace America................................. 63 68.............AirFiltronix............................................... 56 59 ..... Air Systems, Int'l................................... 97 63 Air Systems, int'l.................................... lOO 19.............Amrep..................................................... lOl 27...............Asbestos Abatement Association...... 25 13............. Asbestos Consulting 8t Training Systems.. 24 9.............. Asbestos Disposal Agency.................. 91 49............ BGI......................................................... 11 33.............. Clayton Environmental Consultants.......... 93 35............ Construction Wholesale, Inc................ 92 11.............. Critical Industries, Inc................................... 15 39.............. CRSI....................................................... 103 63 ......... Dawson Associates............................. 99 43 ....... Donovan & Baker, Inc......................... 64 54...........Eagle Plastics, Inc.......................................... lO 66.............. EAP. Inc................................................. 60 71.............. ENCON.................................................. 51 41...............Environmental Risk InsuranceCompany.. 94 61 ...........ERM Group........................................... 13 Page No.AdvertiserCircle No. 65 ........... ESSTEK............................................. 59.............. Fay Goldblatt Laboratories. Inc. 69 ............ General Maintenance, Inc. 53.............. Global Consumer Services, Inc. 51............... Grayling Industries. Inc........ 31....... ' >. Guzeler................................. .. 2. . Hako Minuteman.................... 67 .......... Hall-Kimbrell Environmental Services 70 . ~ ... Institute for Environmental Education 72 . ......... i-TEM. Ltd...................... 66 .... . MAECORP. JPC........................... 15............... Micro Analytical Laboratories 18...............Mid American......................... 57.............. Nikro Industries............... 5................ North Safety Equipment ... 3.. 7. ... Ogden Allied Abatement & Decontamination Services............. 7................ Poly-America................................ 22.............. Professional Environmental Contractors 43.............. Shelburne Labs................................ 64.............. SourceFinders............................... 59.............. Specialty Vacuum, Inc................... 36-37......... Vacuum Engineering..................... 98 55 23 95 53 57 54 16 18 90 61 17 102 52 53 9 22 65 1C5 96 14 8 The Advertisers' Index is published as a service. The publisher does not assume any liability tor errors or omissions. We'd Like To Give You A Piece OfOur Minds!! THE INSTITUTE FOR ENVIRON MENTAL EDUCATION OFFERS THE FOLLOWING COURSES: The Institute's courses are EPA accredited and are approveJ by most jurisdictions chat presently require separate appro* jl Each course is offered monthly at the Institute in Boston, or at a location that best suits your needs- Our on-site training does nor require a minimum number of participants. AHERA CONTRACTOR/ SUPERVISOR: Asbestos Abatement Procedures and Practices AHERA WORKERS: Asbestos Abatement Procedures and Practices AHERA Asbestos Inspectors Training AHERA Asbestos Management Planners Training AHERA Operations and Mainte nance Training PLUS, Annual Refresher Training for all the above courses Please call us at (617) 935-7370 to receive a course schedule or for additional information. INSTITUTE FOR ENVIRONMENTAL EDUCATION 208 West Cummings Park, Boston (Wobum), MA 01801 (617) 935-7370 70 CIRCLE READER SERVICE CARD NO. 18 ASBESTOS ISSUES '88--DECEMBER ALCOA0000007950