at work, 4 fibres/ctii* for 25 years, or 10 fibres/cm' for 10 years. The British Occupa tional Hygiene Society Hygiene Standards Sub-committee on Asbestos expressed the view that a proper and reasonable objective would be to reduce exposures to below this level and thereby reduce the risk of contracting asbestosis to less than I per cent of those who have a lifetime's exposure to the dust. For such workers, who may possibly work for 50 years, the long term average concentration to which they Bre exposed would need to be less than 2 fibres/cm*. For others, who will be exposed to asbestos dust in air for shorter periods, the long term average concentration need not be so low, as long as their exposure will amount to less than 100 fibre years/cm*.
The possibility was considered that short periods of very high concentration for a few weeks or less might be disproportionately important in determining the risk of asbestosis. However, the evidence for this was not conclusive and the committee were satisfied that the risk can be satisfactorily expressed with respect to an average concentration over 3 months and can safely be kept below 1 per cent by ensuring that a man's accumulated exposure does not rise above 100 fibre yeais/crn*.
The exposure measured by making fibre counts on membrane filter samples can be converted into exposure measured with an impinger, the American method, by examining the results of side-by-side comparisons of the two instruments. Such comparisons made by the United Stales Public Health Service in asbestos textile plants have shown that an accumulated exposure of 100 fibre years/cm* corresponds to 15 million particle years/ft' by standard impinger methods (Ayer, Lynch and Fanney, 1965). The present American Threshold Limit Value is a concentration of 5 million particles/ft* (mp/ft*) which, if it persisted, would result in an accumulated exposure of 250 million particle years/ft' over 50 years.
These American hygiene standards, called Threshold limit Values, are a system for summarising published information on air contaminants in a convenient form for the day-to-day practice of industrial hygiene. The present American standard for 8-hr averages is thus 17 times higher than the British standard for 3 monthly averages. However, there is a published intention to revise the American standard in view of recent knowledge.
However, the difference between the American and British standard is not pri marily due to conflicting evidence on the adverse affects of asbestos. It is because of a different attitude now adopted over the degree of protection which ought to be given against asbestosis.
The American Threshold Limit Value of 5 mp/ftJ was recommended by Drcessen and his co-workers in 1938 after studying 541 employees in 4 asbestos textile plants where massive exposures to chrysolile occurred (Drfssen et at., 1938). Only 3 doubtful cases of pneumoconiosis were found at the time of the study in those exposed to dust concentrations under 5 mp/ft', whereas numerous well-marked cases were found above 5 mp/ft*.
A conference held in 1965 on the biological effects of asbestos called attention to the very real probability that the 5 mp/ft' limit recommended by Dreessen is inade quate to give complete working-lifetime protection against all forms of asbestos (Schall, 1965). Medical data on which the limits had been based were inadequate; more than half of the asbestos workers studied by Dreessen and his co-workers were under 30 years of age and thus had insufficient exposure time for much asbestosis to
develop. Of th 5 years and on time" study; w: in the over-all
The British after studying i the ACCiHI Tl Limits, 1968) | while taking in and considerat of the health e> that the 5 mp/ years, a period
In accordai below which al average concert often consists recommended, length are cour by Impinger o 12 fibres/cm'. of asbestos disc
The intcndi to them should given the most to take advant;
The standa
person's arcun ycars/cm*. It i:
clinical signs o these standard!
associated with The standai
over 3 months equals 2. fibrts: this value and s higher than 2 fimum 12 fibres/i
compliance. Th standards from Inspectorate in judgment on cc mum for even : probability lha
There is a dusts from ma