Document vBVEGNkyQZNL6YKNwegmbondR

Heating Systems Orr & Sembower, Inc. Established 1885 Morgantown Road, Reading, Pa. PACKAGED automatic boilers Powermasier boilers are modern, compact, self-contained, completely automatic units with an outstanding record for highly dependable and efficient performance. Standard sizes range from 15 hp to 500 hp for steam generation to 250 psi and for hot water to 30 psi. Powermasters are designed and built to ASME Boiler Code requirements, approved by Underwriters' Laboratories, Inc. and fully guaranteed by Orr & Sembower, Inc. All units are thoroughly factory tested under fire and sup plied with a complete test report. As delivered, Powermasters are fully equipped and completely wired for quick installation and operation. Thousands of .Powermasters are now serving industrial plants, dairies, hospitals, laundries, schools, institutions, and public buildings all over the U. S. and in many other countries. Low-Cost, Compact Installation--No foundation or costly breeching and stack are required. All necessary fittings supplied for readily completing fuel, water, elec tric, Bteam and vent connections. Fuel Economy--Guaranteed 83 per cent minimum efficiency with No. 6 oil. Effi ciency actually increases at less than full load. Automatic control prevents fuel waste with fluctuating steam load. Clean, Quiet Operation--Complete, efficient combustion at all loads assures smoke less operation. Piped-in fuels and leak-tight construction aid cleanliness. Completely Automatic Operation--Full complement of finest up-to-date operating and safety controls provides maximum operating dependability and protection with least possible attention from operator. Maintenance-Saving Accessibility--Water and fire sides completely accessible for easy cleaning and inspection without disturbing burner or accessories. Three-Pass Gas Travel-Successive parallel passes maintain most efficient flue gas velocity, provide maximum maintenance convenience, and eliminate complex front end baffling. Staggered Tubes--Freedom from ineffectual boiler water eddies assures quicker heating, faster steaming, and high quality dry steam. Scrubbing action of rising water prevents corrosive gas deposits on tube surfaces. Forced Draft--Provides more accurate control of combustion air supply; permits use of smaller lower-cost fan and motor; requires less fan maintenance--no hot products of combustion pass through fan. Modulating Combustion Control--Insures proper fuel-air mixture for most efficient firing at all loads. Instantly responds to load swings from 20 per cent to 100 per cent of firing capacity, assuring constant steam pressure and temperature. VORIFLOW Burners--Air-atomizing oil burner and pre-mix gas burner, designed and built by O & S, provide complete, clean combustion over full firing range. Simple, sturdy construction and absence of moving parts minimize maintenance. Combina tion burner permits quick change from one fuel to another. 1478 Heating Systems Boflers. steel Kewanee-Ross Corporation Division of American Radiator & Standard Sanitary Corporation KEWANEE, ILLINOIS Branches in Principal Cities Consult local telephone book for telephone numbers. Appleton, Wisconsin Atlanta, Georgia Baltimore, Maryland Birmingham, Alabama Boston, Massachusetts Butte, Montana Chattanooga, Tennessee Chicago, Illinois Cincinnati, Ohio Cleveland, Ohio Columbus, Ohio Dallas, Texas Denver, Colorado Des Moines, Iowa Detroit, Michigan El Paso, Texas Erie, Pennsylvania Grand Rapids, Michigan Gbb&n Bat, Wisconsin Greensboro, North Carolina Greenville, South Carolina Houston, Texas Indianapolis, Indiana Kansas Crrr, Missouri Kewanee, Illinois Los Angeles, California Louisville, Kentucky Cape Elizabeth,- Maine Memphis, Tennessee Milwaukee, Wisconsin Minneapolis, Minnesota . New Haven, Connecticut New Orleans, Louisiana New York, New York Oklahoma City, Oklahoma Omaha, Nebraska Philadelphia, Pennsylvania. Pittsburgh, Pennsylvania Portland, Oregon - Richmond, Virginia Roanoke, Virginia Saginaw, Michigan St. Louis, Missouri Salt Lake City, Utah San Antonio, Texas San Francisco, California Schenectady, New York Seattle, Washington Spokane, Washington Tampa, Florida Toledo, Ohio Tulsa, Oklahoma Washington, D. C. WrcHiTA, Kansas Wilkes-Barre, Pennsylvania ue&iber KEWANEE PRESENTS A PRINCIPLE OF RATING TO AID ENGINEERS IN SIZING BOILERS KEWANEE Reserve plus RATING guarantees dependability--high efficiency-- low cost--long boiler life because it means operating at nominal capacity. Engineers everywhere know that operating a boiler continuously at maximum capacity lowers efficiency, increases operating and maintenance costs, shortens boiler life and is conducive to expensive breakdown. The proper sizing of a boiler for a specific job is all important. The Kewanee Reserve Plus Rating Plan presents a safe way of judging boilers for proper sizing. Here are the principles of the Kewanee Reserve Plus Plan: 1. Compare like examples when judging boilers. Know whether ratings are based on maximum capacity or nominal ca pacity. 2. Nominal rated boilers with built-in reserve safely provide for fluctuating loads -- emergencies -- expansion -- permit "cruising speed" operation. 3. Kewanee Reserve Plus Rating certifies 50 per cent or more extra power for pick-up and additional capacity. This means the boiler can be operated at "cruising speed" for greater efficiency, low maintenance, dependability and longer boiler life. 4. Kewanee Reserve Plus Rating is based on the approved code of the Steel Boiler Institute. 1479