Document vB9kO1VRn3xrrNJzm8XeD7VDq

FILE NAME Reynolds Metals RM DATE 1975 Oct 1 DOC RM014 DOCUMENT DESCRIPTION Internal Inspection Results with Cover Memo for Sampling Program Procedures 4 INTRACOMPANY GN P 7 T feBy ews sSe COR ESPONDENCE aw et Pe) ag. co . RHr ADE ty FRR ee ot INTRACOMPANY CORRESPONDENCE . SE Rev. 1-6B a a FROM -- -- -- COPY R. E. Bento-n GOB G. L. Suffredini - Sherwin M. Collavo R. D. Bird Dr. R. D. Gamble 19 Sherwin Dr. J. M. MacMillan - EXO DATE & SUBJECT October 1 , 1975 SHERWIN INDUSTRIAL HYGIENE SAMPLING PROGRAM Dear Lou Enclosed please find the protocol for an Industrial Hygiene sampling program to be instituted at Sherwin at your request Sampling information and analytical procedures are set forth so that your staff can carry out the program on an house basis Details of the analytical techniques have already been sent to your Laboratory Director Bob Bird As soon as the plant has acquired the necessary sampling equipment as specified in the sampling data sheets either Mac Cole or I will be glad to come to Sherwin and assist in a training program At that time the logistics of the sampling program and the regime to be followed can be worked out Please note that Mr. Featherston has not been copied on this report since I felt it more appropriate for you to discuss your plans for such a program with him REB dlm Enclosures Ronald E. Benton B.002034 e v 7 we +" Ww a Substance Alumina dust total - nuisance dust Standard hr time weighted average 15 mg Excursion limit 22.5 m Analytical Procedure Gravimetric Initial and final weights are obtained on conditioned 0.8 micron PVC membrane filters Filters should be conditioned in an area where the weight change due to humidity will be kept at a minimum Sampling Procedure - Samples are to be collected by personal sampling pump using a polystyrene cassette holder containing a preweighed 0.8 micron PVC filter cassette face cap on and small plug removed The filter cassette holder is attached to the rubber tubing by an adaptor A flow rate of 2 liters per minute is to be used it should be checked and adjusted as needed throughout the sampling period of 2 hours duration Additional samples should also be collected in order to fully evaluate the eight hour time weighted average exposure for each job category The sampling device is attached to the worker's collar for the purpose of collecting a breathing zone sample With each batch of samples one filter should be submitted for analysis which has been subjected to exactly the same handling as the samples except that air has not been drawn through it Label this as a blank - B.002035 Substance Alumina dust respirable - nuisance dust Standard hr time weighted average 5 mg Excursion limit 10 m Analytical Procedure Gravimetric Initial and final weights are obtained on conditioned 0.8 micron PVC membrane filters Filters should be con- dtioned in an area where the weight change due to humidity will be kept at a minimum Sampling Procedure Samples are to be collected by personal sampling pump using a polystyrene cassette holder containing a preweighed 0.8 ~ micron PVC filter The polystyrene cassette holder is inserted into a standard 10 mm nylon cyclone with a sampling rate of 1.7 liters per minute Sampling rate 1.7 1pm should be checked and adjusted throughout the sampling period Samples should be collected for two hour periods Additional samples should also be collected in order to fully evaluate the eight hour time weighted average exposure for each job category The sampling device is attached to the worker's collar for the purpose of collecting a breathing zone sample samples With each batch of ore filter should be submitted for analysis which has been subjected to exactly the same handling as the samples except that air has not been drawn through it Label this as a blank - B.002036 B.002036 a ll Substance Asbestos Standard hr time weighted average 5 fibers per cc of air greater than 5 microns in length Excursion limit 10 fibers per cc Analytical Procedure Samples should be sent to the Industrial Hygiene Department in Richmond Sampling Procedure Samples are collected using a personal sampling pump plus Millipore type AA membrane filters These filters will come packaged in filter cassette holders from the company The cassette face cap is removed for open face sampling A flow rate of 2 1pm is used it should be checked and adjusted as needed throughout the sampling period A minimum of six minute samples should be collected in order to document an exposure to asbestos fibers The sampling device is attached to the worker's collar for the purpose of collecting a breathing zone sample With each batch of samples one filter should be submitted for analysis which has been subjected to exactly the same handling as the samples except that air has not been drawn through it Label this as a blank B.002037 Substance Bauxite dust total - nuisance dust Standard hr time weighted average Excursion limit 22.5 mg 15 mg Analytical Procedure Gravimetric Initial and final weights are obtained on conditioned 0.8 micron PVC membrane filters Filters should be conditioned ina area where the weight change due to humidity will be kept at a minimum Sampling Procedure Samples are to be collected by personal sampling pump using a polystyrene cassette holder containing a preweighed 0.8 micron PVC filter cassette face cap on and small plug removed The filter cassette holder is attached to the rubber tubing by an adaptor A flow rate of 2 minute is to be used it should be checked and as needed throughout the sampling period of 2 liters per adjusted hours duration Additional samples should be collected in order to fully evaluate the eight hour time weighted average exposure for each job category The sampling device is attached to the worker's collar for the purpose of collecting a breathing zone sample With each batch of samples one filter should be submitted for analysis which has been subjected to exactly the same handling as the samples except that air has not been drawn through it Label this as a blank B.002038 Substance Bauxite dust respirable - nuisance dust Standard hr time weighted average Excursion limit 10 mg Analytical Procedure 5 mg Gravimetric Initial and final weights are obtained on conditioned 0.8 micron PVC membrane filters Filters should be conditioned in an area where the weight change due to humidity will be kept at a minimum Sampling Procedure Samples are to be collected by personal sampling pump using a polystyrene cassette holder containing a preweighed 0.8 micron PVC filter The polystyrene cassette holder is inserted into a standard 10 mm nylon cyclone with a sampling rate of 1.7 liters per minute Sampling rate 1.7 1pm should be checked and adjusted throughout the sampling period Samples should be collected for four hour periods Additional samples should also be collected in order to fully evaluate the eight hour time weighted average exposure for each job category The sampling device is attached to the worker's collar for the purpose of collecting a breathing zone sample With each batch of samples one filter should be submitted for analysis which has been subjected to exactly the same handling as the samples except that air has not been drawn through it Label this as a blank B.002039 Substance Caustic sodium hydroxide Standard hr time weighted average Excursion limit 4 mg 2 mg Analytical Procedure Atomic Absorption Spectroscopy Detection limit 0.02 ml Na Sampling Procedure Samples are to be collected by personal sampling pump using a polystyrene cassette holder containing a preweighed 0.45 micron Millipore membrane filter type HA cassette face cap on and small plug removed The cassette filter holder is attached to the rubber tubing by a cassette adaptor A flow rate of approximately 2 1pm is used it should be checked and adjusted as needed throughout the sampling period The sampling period should be of an 8 hour duration This will allow the collection of enough caustic to be detected by the analytical technique Additional samples should also be collected in order to fully evaluate the 8 hour time weighted average exposure for each job category The sampling device is attached to the worker's collar for the purpose of collecting a breathing zone sample With each batch of samples one filter should be submitted for analysis which has been subjected to exactly the same handling as the samples except that air has not been drawn through it Label this as a blank B.002040 Substance Crystalline silica free silica Standard Respirable dust = 10 mg % quartz + 2 Excursion limit variable Analytical Procedure ray diffraction Initial and final weights are obtained on preconditioned 0.8 micron PVC membrane filters Filters should be conditioned in an area where the weight change due to fluctuations in the humidity will be kept at a minimum Sampling Procedure Samples are to be collected by personal sampling pump using a polystyrene cassette holder containing a preweighed 0.8 micron PVC filter The polystyrene cassette holder is inserted into a standard 10 mm nylon cyclone with a sampling rate of 1.7 liters per minute Sampling rate 1.7 1pm should be checked and adjusted throughout the sampling period Samples should be collected for four hour periods Additional samples should also be collected in order to fully evaluate the eight hour time weighted average exposure for each job category The sampling device is attached to the worker's collar for the purpose of collecting a breathing zone sample With each batch of samples one filter should be submitted for analysis which has been subjected to exactly the same handling as through it the samples Label this except that as a blank air has not been drawn B.002041 Substance Hydrogen sulfide Standard hr time weighted average Excursion limit 22.5 m Analytical Procedure 15 mg Absorption spectroscopy Sampling Procedure Samples are to be collected by personal sampling pump using a midget impinger containing 10 ml of the absorbing solution and 5 ml of 95 ethanol controls foaming for approximately two hours The flow rate should be 1.5 1pm through the impinger with a sampling period of two hours If this time interval does not collect enough H2S for the analytical procedure the sampling time may be extended as necessary If a four hour sample does not collect enough H2S to be measured it may be assumed that the 8 hour time weighted average MESA standard will not be exceeded Additional samples should also be collected in order to fully evaluate the 8 hour time weighted average exposure for each job category The sampling device is attached to the worker's belt An absorption tube with a plug of glass wool is loosely inserted between the exit arm of the impinger and the pump in order to protect the pump from splash or water condensation With each batch of samples one impinger should be submitted for analysis which has been subjected to exactly the same handling as the samples except that air has not been drawn through it Label this as a blank B.002042 ae im ne, a ate Substance Lime calcium oxide Standard hr time weighted average 5 m Excursion limit 10 m Analytical Technique Atomic Absorption Spectroscopy Detection limit 0.07 ml Ca Sampling Procedure Samples are to be collected by personal sampling pump using a polystyrene cassette holder containing a preweighed 0.45 micron Millipore membrane filter type HA cassette face cap on and small plug removed The cassette filter holder is attached to the rubber tubing by a cassette adaptor A flow rate of approximately 2 1pm is used it should be checked and adjusted as needed throughout the sampling period The sampling period should be of a four hour duration This will allow the collection of enough lime to be detected by the analytical technique Additional samples should also be collected in order to fully evaluate the 8 hour time weighted average exposure for each job category The sampling device is attached to the worker's collar for the purpose of collecting a breathing zone sample With each batch of samples one filter should be submitted for analysis which has been subjected to exactly the same handling as the samples except that air has not been drawn through it Label this as a blank B.002043 Substance Noise Standard hr time weighted average Excursion limit none 90 dBA Sampling Procedure Noise exposure determinations are to be made using Dupont audiodosimeters these have already been acquired by the plant Dosimeter measurements integrate noise exposure over the entire work shift Consequently the sampling duration should be of an entire eight work shift The microphone is attached to the collar of the worker just below the ear and the dosimeter is placed in the shirt pocket or clipped to the belt Exposure levels are determined by inserting the memory cell into the audiodosimeter readout and reading the level as a percentage of the permissible exposure B.002044 B.002044 Yea, Substance Solvents e.g. varsol xylene thinners etc. Standard Variable depending upon solvent of concern Analytical Procedure Samples should be sent to the Industrial Hygiene Department in Richmond Sampling Procedure Samples are to be collected by a personal sampling pump using an activated charcoal filled glass tube Immediately before sampling the ends of the tube should be broken so as to provide an opening approximately one half of the internal diameter of the tube The smaller section of charcoal is used as a back and should be positioned nearest the sampling pump A flow rate of approximately 1 1pm is used it should be checked and adjusted as needed throughout the sampling period The sampling period should be of a 2 to 4 hour duration Additional samples should also be collected in order to fully evaluate the eight hour time weighted sampling vertical average exposure for each job category The device is attached to the worker's collar in a position for the purpose of collecting a breathing zone sample With each batch of samples one charcoal tube should be submitted for analysis which has been subjected to exactly the same handling as the samples except that air has not been drawn through it Label this as a blank B.002045 aeaft we s wo WELDING FUMES At the present time there is no specific MESA standard regarding welding fumes However such a standard has been incorporated into the 1974 Threshold Limit Value Value Book and will eventually be included as a MESA standard As a result welding samples should be taken and compared with proposed guidelines for total welding fumes When considering welding operations we also have to be aware of the various alloys and components used in welding applications For example at Sherwin you do a great deal of welding on stainless steel Stainless steel usually contains a significant percentage of chromium up to 30 and nickel up to 35 These two components of course are covered in the MESA standards as specific substances Consequently samples should be collected in order to evaluate an employee's exposure to the various metals released during the welding procedure Substance Individual components Zn etc. of welding fumes e.g. Fe Cr Ni Standard Depends upon component of concern Analytical Procedure Atomic Absorption Spectroscopy Detection limit varies with metal of concern Sampling Procedure Samples are to be collected by personal sampling pump using a polystyrene cassette holder containing a preweighed 0.45 micron Millipore membrane filter type HA cassette face cap on and small plug removed The cassette filter holder is attached to the rubber tubing by a cassette adaptor A flow rate of approximately 2 1pm is used it should be checked and adjusted as needed throughout the sampling period The sampling period should be of a 2 to 4 hour duration This will allow the collection of enough welding fumes to be detected by the analytical 1 technique Additional samples should also be collected continued B.002046 B.002046 Welding Fumes Sampling Procedure continued in order to fully evaluate the 8 hour time weighted average exposure for each job category The sampling device is attached to the worker's collar for the purpose of collecting a breathing zone sample With each batch of samples one filter should be for analysis which has been subjected to exactly same handling as the samples except that air has been drawn through it Label this as a blank submitted the not B.002047 PUMP CALIBRATION PROCEDURE The calibration setup for a personal sampling pump with a filter cassette or charcoal tube is shown in Figure XI Before starting the calibration procedure make sure that the sampling pump has been adequately charged Once this has been done assemble the sampling train as shown in Figure XI Turn pump on and moisten the inside of the one liter buret by immersing the buret in the soap solution and draw bubbles up the inside of the buret until they are able to travel the entire length of the buret without bursting Adjust the pump flow meter until the flow meter ball is at a particular numerical setting read at the middle of the ball Start a soap bubble up the buret and measure the time it takes the bubble to move up the graduated portion of the one liter buret Repeat the procedure at least twice average the results and calculate the flow rate by dividing the volume one liter by the time required for the soap bubble to traverse the distance This entire procedure should be repeated at several other ball settings for each type of sample to be collected i.e. membrane filters PVC filters charcoal tubes etc. The data for the calibration should include the volume measured the serial number of the pump and pump number date of calibration and the name of the person doing the calibration This data should be kept in a loose leaf notebook binder calibration checks should be performed at six month intervals and this data should replace the old calibration information B.002048 See (svet dungame Suidwegapeamemne oat BES ItE | pyiaste ) ie] ones 08 FOR(}einq SETUPsaa FOR 121 HLISVD YILTIa Pump Pump ONTIANVS IVNOSUAd YOd dLaS NOLVUEITY *T deog ~ IX 000) gundI sayeog fe US, Crt Pernt tet: 467-065 (2034 B.002049 bSs ecar.ee sre = re . EQUIPMENT LIST Recommend that you order the following equipment Millipore Corporation Ashby Road Bedford Massachusetts Tel 617 275-9200 01730 1 polystyrene cassettes package of 100 catalog # M 0000 3700 5 filter cassette holder adaptor aerosol adaptor catalog # XX62 000 04 1 membrane filters Type AA ctn catalog # MAWP 037 AO 1 membrane filters Type HA pkg catalog # HAWP 037 00 National Environmental Instruments Inc. Occupational Health Air Pollution & Safety P. O. Box 590 Warwick Rhode Island 02888 Tel 401 738 3710 Instrumentation , 55 model 31 pump with counter catalog # 2418875 0001 rechargeable Nicad battery pack - 4 cell catalog # 2418592 0001 . flow meter 1-4 liters catalog # 2418811 0001 flow meter 25-200 cc catalog # 2418756 0001 5 2 low flow valve assembly catalog # 2418861 0001 hose ten inches catalog # 2417220 0001 rubber cap catalog # 2418860 0117 comprehensive illustrated operation and service manual including exploded views and spare parts list catalog # 1138183 1 5 BDX 99 respirable dust lapel sampler catalog # 2418543 0001 Mine Safety Appliances Company 201 N. Braddock Avenue Pittsburgh Pennsylvania 15208 2 membrane filters Type FWS PVC pkg part # 625413 4 cellulose bands jar part # 625414 continued B.002050