Document vB9kO1VRn3xrrNJzm8XeD7VDq
FILE NAME Reynolds Metals RM
DATE 1975 Oct 1 DOC RM014
DOCUMENT DESCRIPTION Internal Inspection Results with Cover Memo for Sampling Program Procedures
4
INTRACOMPANY GN P 7 T
feBy ews sSe COR ESPONDENCE aw
et Pe)
ag.
co .
RHr ADE ty
FRR
ee ot
INTRACOMPANY CORRESPONDENCE
.
SE Rev. 1-6B
a
a
FROM
-- -- --
COPY
R. E. Bento-n GOB
G. L. Suffredini - Sherwin
M. Collavo R. D. Bird Dr. R. D. Gamble 19 Sherwin
Dr. J. M. MacMillan - EXO
DATE & SUBJECT
October 1 , 1975
SHERWIN INDUSTRIAL HYGIENE SAMPLING PROGRAM
Dear Lou
Enclosed please find the protocol for an Industrial Hygiene sampling program to be instituted at Sherwin at your request
Sampling information and analytical procedures are set forth
so that your staff can carry out the program on an house basis Details of the analytical techniques have already been sent to your Laboratory Director Bob Bird
As soon as the plant has acquired the necessary sampling equipment as specified in the sampling data sheets either Mac Cole or I will be glad to come to Sherwin and assist in a training program At that time the logistics of the sampling program and the regime to be followed can be
worked out
Please note that Mr. Featherston has not been copied on this report since I felt it more appropriate for you to discuss your plans for such a program with him
REB dlm Enclosures
Ronald E. Benton
B.002034
e
v 7 we +"
Ww a
Substance
Alumina dust total - nuisance dust
Standard hr time weighted average
15 mg
Excursion limit 22.5 m
Analytical Procedure
Gravimetric
Initial and final weights are obtained on conditioned
0.8 micron PVC membrane filters Filters should be
conditioned in an area where the weight change due to humidity will be kept at a minimum
Sampling Procedure -
Samples are to be collected by personal sampling pump using a polystyrene cassette holder containing a preweighed 0.8 micron PVC filter cassette face cap on and small plug removed The filter cassette holder is attached to the rubber tubing by an adaptor A flow rate of 2 liters per minute is to be used it should be checked and adjusted as needed throughout the sampling period of 2 hours duration Additional samples should also be collected in order to fully evaluate the eight hour time weighted average exposure for each job category The sampling device is attached to the worker's collar for the purpose of collecting a breathing zone sample
With each batch of samples one filter should be submitted for analysis which has been subjected to exactly the same handling as the samples except that air has not been drawn through it Label this as a blank
-
B.002035
Substance
Alumina dust respirable - nuisance dust
Standard
hr time weighted average 5 mg
Excursion limit 10 m
Analytical Procedure Gravimetric
Initial and final weights are obtained on conditioned
0.8 micron PVC membrane filters Filters should be con-
dtioned in an area where the weight change due to humidity
will be kept at a minimum
Sampling Procedure
Samples are to be collected by personal sampling pump using a polystyrene cassette holder containing a preweighed 0.8 ~ micron PVC filter The polystyrene cassette holder is inserted
into a standard 10 mm nylon cyclone with a sampling rate of 1.7 liters per minute Sampling rate 1.7 1pm should be checked and adjusted throughout the sampling period Samples
should be collected for two hour periods Additional samples
should also be collected in order to fully evaluate the eight hour time weighted average exposure for each job category The sampling device is attached to the worker's collar for
the purpose of collecting a breathing zone sample
samples With each batch of
ore filter should be submitted
for analysis which has been subjected to exactly the same
handling as the samples except that air has not been drawn
through it Label this as a blank
-
B.002036 B.002036
a ll
Substance Asbestos
Standard
hr time weighted average 5 fibers per cc of air greater than 5 microns in length
Excursion limit 10 fibers per cc
Analytical Procedure Samples should be sent to the Industrial Hygiene
Department in Richmond
Sampling Procedure Samples are collected using a personal sampling pump plus Millipore type AA membrane filters These filters will
come packaged in filter cassette holders from the company The cassette face cap is removed for open face sampling A flow rate of 2 1pm is used it should be checked and adjusted as needed throughout the sampling period A minimum of six minute samples should be
collected in order to document an exposure to asbestos
fibers The sampling device is attached to the worker's collar for the purpose of collecting a breathing zone sample With each batch of samples one filter should be submitted for analysis which has been subjected to exactly the same handling as the samples except that air has not been drawn through it Label this as a blank
B.002037
Substance
Bauxite dust total - nuisance dust
Standard
hr time weighted average
Excursion limit 22.5 mg
15 mg
Analytical Procedure
Gravimetric
Initial and final weights are obtained on conditioned
0.8 micron PVC membrane filters Filters should be conditioned
ina area where the weight change due to humidity will be kept at a minimum
Sampling Procedure
Samples are to be collected by personal sampling pump using a polystyrene cassette holder containing a preweighed 0.8 micron PVC filter cassette face cap on and small plug removed The filter cassette holder is attached to the
rubber tubing by an adaptor A flow rate of 2 minute is to be used it should be checked and as needed throughout the sampling period of 2
liters per
adjusted
hours duration
Additional samples should be collected in order to fully evaluate the eight hour time weighted average exposure for each job category The sampling device is attached to the worker's collar for the purpose of collecting a breathing
zone sample
With each batch of samples one filter should be submitted for analysis which has been subjected to exactly the same handling as the samples except that air has not been drawn through it Label this as a blank
B.002038
Substance
Bauxite dust respirable - nuisance dust
Standard
hr time weighted average
Excursion limit 10 mg
Analytical Procedure
5 mg
Gravimetric
Initial and final weights are obtained on conditioned 0.8 micron PVC membrane filters Filters should be conditioned in an area where the weight change due to humidity will be kept at a minimum
Sampling Procedure
Samples are to be collected by personal sampling pump using a polystyrene cassette holder containing a preweighed 0.8 micron PVC filter The polystyrene cassette holder is inserted into a standard 10 mm nylon cyclone with a sampling rate of 1.7 liters per minute Sampling rate 1.7 1pm should be checked and adjusted throughout the sampling period Samples should be collected for four hour periods Additional samples should also be collected in order to fully evaluate the eight hour time weighted average exposure for each job category The sampling
device is attached to the worker's collar for the purpose of collecting a breathing zone sample
With each batch of samples one filter should be submitted for analysis which has been subjected to exactly the same handling as the samples except that air has not been drawn through it Label this as a blank
B.002039
Substance
Caustic sodium hydroxide
Standard
hr time weighted average
Excursion limit 4 mg
2 mg
Analytical Procedure
Atomic Absorption Spectroscopy Detection limit 0.02 ml Na
Sampling Procedure
Samples are to be collected by personal sampling pump using a polystyrene cassette holder containing a preweighed 0.45 micron Millipore membrane filter type HA cassette face cap on and small plug removed The cassette filter holder is attached to the rubber tubing by a cassette adaptor A flow rate of approximately 2 1pm is used it should be checked and adjusted as needed throughout the sampling period The sampling period should be of an 8 hour duration This will allow the collection of enough caustic to be detected by the analytical technique Additional samples should also be collected in order to fully evaluate the 8 hour time weighted average exposure for each job category The sampling device is attached to the worker's collar for the purpose of collecting a breathing zone sample
With each batch of samples one filter should be submitted for analysis which has been subjected to exactly the same handling as the samples except that air has not been drawn through it Label this as a blank
B.002040
Substance
Crystalline silica free silica
Standard
Respirable dust = 10 mg
% quartz + 2
Excursion limit variable
Analytical Procedure
ray diffraction
Initial and final weights are obtained on preconditioned
0.8 micron PVC membrane filters Filters should be
conditioned in an area where the weight change due to fluctuations in the humidity will be kept at a minimum
Sampling Procedure
Samples are to be collected by personal sampling pump using a polystyrene cassette holder containing a preweighed 0.8 micron PVC filter The polystyrene cassette holder is inserted into a standard 10 mm nylon cyclone with a sampling rate of 1.7 liters per minute Sampling rate 1.7 1pm should be checked and adjusted throughout the sampling period Samples should be collected for four hour periods Additional samples should also be collected in order to fully evaluate the eight hour time weighted average exposure for each job category The
sampling device is attached to the worker's collar for the purpose of collecting a breathing zone sample
With each batch of samples one filter should be submitted
for analysis which has been subjected to exactly the same
handling as through it
the samples
Label this
except that as a blank
air has not
been
drawn
B.002041
Substance
Hydrogen sulfide
Standard
hr time weighted average
Excursion limit 22.5 m
Analytical Procedure
15 mg
Absorption spectroscopy
Sampling Procedure
Samples are to be collected by personal sampling pump
using a midget impinger containing 10 ml of the absorbing solution and 5 ml of 95 ethanol controls foaming for approximately two hours The flow rate should be 1.5 1pm through the impinger with a sampling period of two hours If this time interval does not collect enough H2S for the analytical procedure the sampling time may be extended as necessary If a four hour sample does not collect enough H2S to be measured it may be assumed that the 8 hour time weighted average MESA standard will not be exceeded Additional samples should also be collected in order to fully evaluate the 8 hour time weighted average exposure for each job category The sampling device is attached to the worker's belt An absorption tube with a plug of glass wool is loosely inserted between the exit arm of the impinger and the pump in order to protect the pump from splash or water condensation
With each batch of samples one impinger should be submitted for analysis which has been subjected to exactly the same handling as the samples except that air has not been drawn through it Label this as a blank
B.002042
ae
im ne,
a
ate
Substance
Lime calcium oxide
Standard
hr time weighted average
5 m
Excursion limit 10 m
Analytical Technique
Atomic Absorption Spectroscopy
Detection limit 0.07 ml Ca
Sampling Procedure
Samples are to be collected by personal sampling pump using a polystyrene cassette holder containing a preweighed 0.45 micron Millipore membrane filter type HA cassette face cap on and small plug removed The cassette filter holder is attached to the rubber tubing by a cassette adaptor A flow rate of approximately 2 1pm is used it should be checked and adjusted as needed throughout the sampling period The sampling period should be of a four hour duration This will allow the collection of enough lime to be detected by the analytical technique Additional samples should also be collected in order to fully evaluate the 8 hour time weighted average exposure for each job category The sampling device is attached to the worker's collar for the purpose of collecting a breathing zone sample
With each batch of samples one filter should be submitted for analysis which has been subjected to exactly the same handling as the samples except that air has not been drawn through it Label this as a blank
B.002043
Substance Noise
Standard
hr time weighted average
Excursion limit none
90 dBA
Sampling Procedure
Noise exposure determinations are to be made using Dupont
audiodosimeters these have already been acquired by the
plant Dosimeter measurements integrate noise exposure over the entire work shift Consequently the sampling duration should be of an entire eight work shift The microphone is attached to the collar of the worker
just below the ear and the dosimeter is placed in the shirt pocket or clipped to the belt Exposure levels are determined by inserting the memory cell into the audiodosimeter readout and reading the level as a percentage
of the permissible exposure
B.002044 B.002044
Yea,
Substance
Solvents e.g. varsol xylene thinners etc.
Standard
Variable depending upon solvent of concern
Analytical Procedure
Samples should be sent to the Industrial Hygiene Department in Richmond
Sampling Procedure
Samples are to be collected by a personal sampling pump using an activated charcoal filled glass tube Immediately before sampling the ends of the tube should be broken so as to provide an opening approximately one half of the
internal diameter of the tube The smaller section of
charcoal is used as a back and should be positioned
nearest the sampling pump A flow rate of approximately
1 1pm is used it should be checked and adjusted as needed throughout the sampling period The sampling period should
be of a 2 to 4 hour duration Additional samples should also
be collected in order to fully evaluate the eight hour time
weighted sampling vertical
average exposure for each job category The
device is attached to the worker's collar in a
position for the purpose of collecting a breathing
zone sample
With each batch of samples one charcoal tube should be submitted for analysis which has been subjected to exactly the same handling as the samples except that air has not been drawn through it Label this as a blank
B.002045
aeaft we
s wo
WELDING FUMES
At the present time there is no specific MESA standard regarding welding fumes However such a standard has
been incorporated into the 1974 Threshold Limit Value Value
Book and will eventually be included as a MESA standard As a result welding samples should be taken and compared with proposed guidelines for total welding fumes When considering welding operations we also have to be aware of the various alloys and components used in welding applications For example at Sherwin you do a great deal of welding on stainless steel Stainless steel usually contains a significant percentage of chromium
up to 30 and nickel up to 35 These two components of course are covered in the MESA standards as specific substances Consequently samples should be collected
in order to evaluate an employee's exposure to the various
metals released during the welding procedure
Substance
Individual components Zn etc.
of welding fumes
e.g.
Fe
Cr
Ni
Standard
Depends upon component of concern Analytical Procedure
Atomic Absorption Spectroscopy Detection limit varies with metal of concern
Sampling Procedure
Samples are to be collected by personal sampling pump
using a polystyrene cassette holder containing a preweighed 0.45 micron Millipore membrane filter type HA cassette face cap on and small plug removed The cassette filter holder is attached to the rubber tubing by a cassette
adaptor A flow rate of approximately 2 1pm is used it should be checked and adjusted as needed throughout the
sampling period The sampling period should be of a 2
to 4 hour duration This will allow the collection of
enough welding fumes to be detected by the analytical
1
technique Additional samples should also be collected
continued
B.002046 B.002046
Welding Fumes
Sampling Procedure continued
in order to fully evaluate the 8 hour time weighted average exposure for each job category The sampling device is attached to the worker's collar for the
purpose of collecting a breathing zone sample
With each batch of samples one filter should be for analysis which has been subjected to exactly same handling as the samples except that air has been drawn through it Label this as a blank
submitted the
not
B.002047
PUMP CALIBRATION PROCEDURE
The calibration setup for a personal sampling pump with a filter cassette or charcoal tube is shown in Figure XI Before starting the calibration procedure make sure that the sampling pump has been adequately charged Once this has been done assemble the sampling train as shown in
Figure XI Turn pump on and moisten the inside of the one liter buret by immersing the buret in the soap solution and draw bubbles up the inside of the buret until they are able to travel the entire length of the buret without bursting
Adjust the pump flow meter until the flow meter ball is at
a particular numerical setting read at the middle of the
ball Start a soap bubble up the buret and measure the time it takes the bubble to move up the graduated portion of the one liter buret Repeat the procedure at least twice average the results and calculate the flow rate by dividing the volume one liter by the time required
for the soap bubble to traverse the distance
This entire procedure should be repeated at several other ball settings for each type of sample to be collected
i.e. membrane filters PVC filters charcoal tubes etc.
The data for the calibration should include the volume
measured the serial number of the pump and pump number date of calibration and the name of the person doing the calibration This data should be kept in a loose leaf notebook binder calibration checks should be performed at six month intervals and this data should replace the
old calibration information
B.002048
See
(svet dungame
Suidwegapeamemne
oat
BES
ItE
|
pyiaste
)
ie] ones
08
FOR(}einq
SETUPsaa FOR
121
HLISVD
YILTIa
Pump Pump
ONTIANVS
IVNOSUAd
YOd
dLaS
NOLVUEITY
*T
deog ~
IX
000)
gundI
sayeog
fe US, Crt Pernt tet: 467-065 (2034
B.002049
bSs ecar.ee sre = re .
EQUIPMENT LIST
Recommend that you order the following equipment
Millipore Corporation
Ashby Road
Bedford Massachusetts Tel 617 275-9200
01730
1
polystyrene cassettes package of 100 catalog #
M 0000 3700
5
filter cassette holder adaptor aerosol adaptor
catalog # XX62 000 04
1
membrane filters Type AA ctn catalog # MAWP
037 AO
1
membrane filters Type HA pkg catalog # HAWP
037 00
National Environmental Instruments Inc.
Occupational Health Air Pollution & Safety
P. O. Box 590
Warwick Rhode Island 02888
Tel 401 738 3710
Instrumentation ,
55 model 31 pump with counter catalog # 2418875 0001 rechargeable Nicad battery pack - 4 cell catalog
# 2418592 0001
.
flow meter 1-4 liters catalog # 2418811 0001
flow meter 25-200 cc catalog # 2418756 0001
5 2 low flow valve assembly catalog # 2418861 0001 hose ten inches catalog # 2417220 0001 rubber cap catalog # 2418860 0117 comprehensive illustrated operation and service
manual including exploded views and spare parts
list catalog # 1138183 1
5
BDX 99 respirable dust lapel sampler catalog # 2418543 0001
Mine Safety Appliances Company
201 N. Braddock Avenue
Pittsburgh Pennsylvania 15208
2
membrane filters Type FWS PVC pkg
part # 625413
4
cellulose bands jar part # 625414
continued
B.002050