American Society of Heating and Ventilating Engineers Guide, 1930 SELECTION OF FANS FOR VENTILATION Two important factors in selecting fans for ventilating systems are: efficiency (which affects the cost of operation) and noise. First cost and space available are secondary, The fans should be selected to operate at maximum efficiency without noise. Noise in a ventilating system is irritating and a cause for complaint. Fans must be selected of proper size in order to reduce it to a minimum. Noise may be caused by other factors than the fan, namely, high velocity .in the duct work, unsatisfac tory location of the fan room, improper construction of floors and walls and poor installation. Where noise is chargeable directly to the fan, it is caused either by excessive peripheral speeds, or the fan is of insufficient size. A noisy fan usually is one which is operated at a point considerably beyond maximum efficiency. Fig. 5. Characteristics of Fully Backward Curved Multiblade Fans For a given static pressure there is a corresponding outlet velocity and peripheral speed wherein maximum efficiency is obtained. If a fan be selected to operate, at this point, the cost of operation and the noise can be held within control. To aid in selecting fans as near as possible to. the point of maximum efficiency, there are listed for each static pressure, corresponding'outlet velocities and tip speeds which will give satisfactory results. The proper tip speed for a given static pressure varies with design of wheel and number of blades or vanes in wheel. .Lower outlet velocities than listed in Table 1 may be used, but care must be exercised to avoid selecting a fan for operation below its useful range. In exhaust ventilating systems where the air column moves toward the fan, noise due to the higher tip speeds and outlet velocities, will not be so readily transmitted back through the air column-to the building. 436 Chapter 26--Selection of Fans and Motive Power Therefore, higher outlet velocities, up to as much as 2,000 ft. per minute may be used, but this will be at the expense of increased power. Amply large fans should always be used for both exhaust and supply systems, as there may be and usually is leakage despite the most careful workmanship, necessitating the delivery of more air at the fans than is exhausted from or supplied through the openings in the various rooms. Long runs of distributing ducts, heaters, air washers, etc., usually are parts of any ventilating system where high static pressures are needed. Under such conditions it is practicable to select fans with higher outlet velocities and peripheral speeds since the duct system itself will tend to muffle objectionable air sounds. Fans with low outlet velocities should be used regardless of the static pressure, if connected with short ducts to register faces, on account of noise. Table X. Good Operating Velocities and Tip Speeds for Forward Curved Multiblade Ventilating Fans : Static Pressure In Inches op Water M % XA Vs K % l l\i l'A 1% 2 2 2A 3 Outlet Velocity Feet per Minute 1000-1100 1000-1100 1000-1200 1100-1300 1200-1400 1300-1600 1500-1800 1600-1900 - 1800-2100 1900-2200 2000-2400 2200-2600 2300-2600 2500-2800 . Tip Speed Feet per Minute 1520-1700 1760-1900 1970-2150 2225-2450 2480-2700 2660-2910 2820-3120 3162-3450 3480-3810 3760-4205 4000-4500 4250-4740 4475--4970 4900-5365 FANS FOR DRYING Both disc and centrifugal types of fans are used for drying work. Disc fans are well adapted to the removal of moisture-laden air when operating against low resistance and when handling air at low temperatures. Motors on these fans usually are of the fully-enclosed moisture-proof types so that saturated air or air containing foreign material will not injure the motors.. Unit heaters employing disc or propeller type fans are widely used in the drying field. In drying, disc or propeller fans may be used where not too much duct work is required and where air is to be delivered against pressure, since the noise developed from the high peripheral speed of these fans is not ordinarily objectionable in process work of this nature. Centrifugal fans or blowers of the multiblade type generally are selected to supply air for drying, as they are capable of delivering large volumes against all pressures with a minimum amount of power. Belt driven faris-usually are to be preferred to direct-connected fans as they make a more flexible and economical unit. Wherever drying is 437