Document v6wx6opD8Ej34JyNxwwOJkMNm
The Fulton Company
Valoes and Heating Specialties
No. 930 and No. 931 Temperature Regulator
For nearly all requirements where
liquids are heated by steam, and especially industrial uses. Regulators are regularly
furnished with a tempera ture range of 140 degrees
to 180 degrees Fahr.
Special regulators can be furnished with adjustment for 20 degrees above or
below the operating point for temperatures not lower than 20 degrees nor higher than 320 degrees Fahr.
No. 930 Regulator is
the same as No. 931, ex
cept that it has lever and
weight method of adjust
ment instead of spring
type shown. The extreme
sensitiveness, positive ac
tion and simplicity of these regulators have
placed them in a class by themselves, and
made them applicable in hundreds of ways.
No. 931 Regulators are furnished regularly
in sizes from
to 2Y" inclusive, and
the No. 930 Regulator in sizes from to
8"-inclusive.
Upon application, a chart will be fur
nished showing size of regulator for any
given condition.
Ask for Chart and Bulletin TR 3
No. 932 Temperature Regulator
Detachable Tube Type: This is the
latest development in self-contained reg ulators. This regulator, is composed of three distinct and separable units. These
units are made so
that each may be separately removed or replaced for repairs as the case may be.
If the flexible tubing should become dam aged or broken, the
power transmitting unit may readily be replaced by loosening
two lock nuts, and the repair part slip ped in to` place. The operation is similar
to No. 930 and No. 931 instruments.
Ask for Bulletin TR 3
which supplies heating coil can be run past
the point where regulator bulb is installed.
Made in valve sizes Y" to 1Y". AH valves are double-seated balanced type, with bronze discs and seats.
Ask for Bulletin TR 3
Sylphon Regitherm
The most powerful room thermostat on the market. Requires no electricity,
compressed air or clockwork to operate. Responds to slight changes
in temperature of air and is used to control valves, dampers and shutters. Works smoothly, never
by jerks and is noiseless in operation. Requires no
attention. Standard range 60 degrees to 80 degrees Fahr. It is largely used in
offices and industrial plants. Small and neat in appearance, being 6" wide by 7W
long.
Ask for Bulletin RR 3
The Ja-Nar Radiator Cover
Made of fine furniture steel, lined with heat insulating material. Completely
covers hot water and steam radiators. Can be installed in old homes as easily as in new. Furnished in light or dark oak,
mahogany,walnut and various tinted enam els, or to match any interior wood-work.
Furnished in three types: 1st, Auto
matic Temperature Control; 2nd, Man
ually Operated Temperature Control; 3rd, Uncontrolled Type.
The controlled type Ja-Nar Radiator cover is equipped with a thermostatic de vice which opens or closes the shutters to
regulate the heat sent out into the room. This is absolutely automatic in operation and can be set to operate at any.comfort-
able temperature desired.
No. 933 Temperature Regulator
Direct Connected Type: Valve mount
ed directly on thermostatic bulb. For hot water storage tanks in hotels, office build- . ings, apartment houses, restaurants, clubs,
etc. Adapted for use when steampipe
Ask for Pamphlet on the Ja-Nar
"Specification Data*'--Send for our "Specifications of Value" which gives.com plete engineering data in regard to the above products.
340
Valves
Gorton & Lidgerwood Co.
96 Liberty St., NEW YORK, N. Y. 1917 Fisher Building, CHICAGO, ILL.
Steam and Hot Water Heating Boilers; Quarter Turn Packing Lock Radiator Valves; Single Pipe Vapor Heating System.
HEATING BOILERS
.The Gorton Boilers are of steel, built according to the A. S. M. . Boiler Code. They are of the vertical tube type, selfcontained, require no brick setting. They are self-feeding, insuring a steady supply of heat for ten to twelve hours with one firing. They are built for both steam and hot water systems.
RADIATOR VALVES
The disc is made of'a mineral composi tion; is not affected by steam or water. The disc and seat are both ground to perfect taper surface. This combination is proof against corrosion, wedging, cut ting, abrasion and leaking.
Reference to the illustration shows the valve has a full pipe size, unobstructed, straight passageway. This permits a free rapid passage of steam or water through the valve unrestricted by friction, giving a quicker flow than in ordinary valves. This permits the use of a valve one size smaller than required when using
the' ordinary valve.
SCHEDULE OF GORTON VALVE SIZES
STEAM HEATING, SINGLE PIPE
CONNECTION
Radiators up to 25 ft......... .......% in. Valve
From 25 to 60 ft--......................1 in. Valve
From 60 to 100 ft.................. l)i in. Valve
From 100 to'200 ft... ..............in. Valve
vapor and vacuum heating, two
PIPE CONNECTIONS
Radiators up to 90 ft............... in. Valve
From 90 to 180 ft.--................. % in. Valve
From 180 to 360 ft... ..................1 in. Valve From 360 to 540 ft... ..............1 in. Valve From 540 to 720 ft... ..............*n* Valve
The Gorton Quarter Turn Packing Lock Radiator Valve is applicable for all Steam, Vapor, Vacuum and Hot Water Heating Systems. It is made throughout
HOT WATER HEATING
Use the regular size of Valves, accord ing to the System installed.
The Gorton Quarter Turn Packing
of the best materials obtainable. It has Lock Valve is made in both the Straight
the following advantages:--
It is quick opening, a turn of the wrist or a touch of the foot opens or closes it, a quarter turn of the lever is all that is
way and Angle patterns. Where a corner
or offset valve is required, the Straightway Valve is used and connection made to it with a street elbow at any angle desired.
needed. This tends to coal economy. Be
SINGLE PIPE VAPOR SYSTEM
cause of its easy operation women will The full opening in the valve, combined
shut off a radiator to cool a room.
with the shape of this opening, allows the
The valve is made tight by means of a ball shoulder on valve stem seating in a
ground opening in the under side of bonnet,
like the seat of a safety valve. What slight wear may occur only tends to produce a better bearing surface. This is supple mented by soft but firm packing rings,
forced and locked into the groove in valve stem by a gland forced down by the pack
ing box nut. This combination insures a
tight valve, and one that wilt remain tight.
.
water of condensation from the radiator to
flow along the bottom of the valve without interfering with the inflow of steam or vapor. This enables vapor to circulate
through the eotire system at low pressure.
The Gorton Air Relief Valve gives easy, rapid and xomplete clearance of air at
vapor pressure. These two features, the Gorton Supply Valve and the Gorton Air
Relief Valve, give a Single Pipe Vapor System that has proven a great success.
341