DEPARTMENT 246/259 1974 OrBRATIONS REPORT (Coni'd)
MAY
Biphenyl flowed at an improved pace throughout May.
Two Aroolor 1016 rune wore made mid-month utilizing "high" Mo.thy 1 biphenyl content biphenyl ns feedstock. . The 1016, ns well ns the Aroclor 12611 produced using the subsequent column bottoms, was in specification and saleable.
A 1400 gallon test blend of Aroclor 1489 (90% 1016, 10% MCS-1302) is being prepared at month's end. . Experiencing some difficulties in meeting suggested electrical specifications.
JUNE `
There was a Clj shortage most of the month. Lost 98 hours of chlorlnator production.
No shipments wore missed but department and warehouse inventories are very low on both Aroclor and Pyranol.
A safety platform was installed on the back of the montar trailer. Montar was dropped one time in 15 drums while the trailer was out of service.
The top of #1 Intermediate.storage tank was repaired after 5 nozzles corroded off. Started air sweep on fl and (12 Intermediate storages on 6/14.
A 15 drum shipment of Aroclor 1489 was made to Electric Utilities Company.
JULY
Department and Warehouse inventories of Aroclor and Pyranols wore near zero, except for 1016.
The column condenser was tested for leakage but test of 1504 static pressure did not show leak. The last 6 column runs averaged ~55 ppm on HjO.
Made 153 drums of Capacitor 21.
Lost 119 hours chlorination due to departments 213 and 217 being down.
Kan Cclays at reduced rote duo to chlorine shortage.
A now demister housing was installed on the blow Brink
tank.
,
MONS 055812
i^ir.ARTHBNT_2Afi/2 59.J.97.4_OJMSRAJ.1 LNS_.Rl.tqrr (Con t' A ) AllCUST
Department operated at reduced rotes throughout month due to chlorine allocution ond biphenyl flow. Roth areas hod improved at month's end. TCI! continued in short supply.
A now top was installed on (13 batch ehl.o r i on t o r and put into
service 8/20. HJphonyl was used sparingly ns 3254 feed stock due to refined residue shortage,
SErT.BMBJvH
An experimental Dow Monoch1 orobipheny1 run was performed 9/19 through 9/26. The 53M lbs. of product met all spc clfications. The production proceeded with minor difficulties, however, anticipated rates on the chlorinators and column were not fully realised,
.
Virgil. Drawl cy left the department 9/23, having been promoted to Department 276 Production Supervisor. Tom Carrico returned to the department 9/9 after recovering from minor 'surgery.
The chlorinators were down 24 hours 9/18 for plant steam repairs, and the week of 9/22 for the Acid Division turnaround. The chlorinators remain down at month's end due to Acid Unit repairs estimated to last 2-4 weeks. Department inventories are becoming critically low.
biphenyl yield was somewhat low for> the month. This is due
in part to holding the intermediate fraction of the Mono run
for future disposition. Further recoveries will occur as the
residues arc converted to 1254.
1
oc'iwi
.
Department 246 started up 10/3 ond ran 22 dny6 drowning the HC1
off-gas to the sewer due to continued Acid Division repairs.
Averago daily departmental PCI! losses during this period were at or
below normal levels. Operations have again been locked-ln to the
Acid Division since 10/26.
,
All material from the first Aroclor 1016 run since Monochlorobiphenyl production was in specification. 1016 Penta/Hexa content hns been higher than normal since mid-October. Visual inspection of the column 11/1 revealed some damage to the top two trays, doubtlessly contributing to this increase. Column operations have been modified slightly to alleviate this condition.
bill Crabtree became Department 246/259 Production Foreman effective 10/21. Tom Carrico participated in a cusLoincr relations visit to Heavy Duty, Goldsboro, N.C., 10/23-10/24.
Higher biphenyl yields for the month reflect the anticipated return on conversion of "Mono" residue to Aroclor 1254.
HONS 055813
NOJMHJMik
While Pyranol sales continue at an increased pace, Aroclor inventories ore at two year hif,h. Specification 1016 continues to be produced under slightly modified column operations. Elimi nation of the "boildovn" step has reduced the size of a column run by approximately 5 %.
One customer complaint wos received car of lncrtccn 54201-CM (1242 PPO) boston, reportedly had a high power reserve sample verified this.
during the month. A lank to Wes t Inghnuse, South factor. Anolysls of the
The 1016 column operated under a natural gos curtailment for most of the month. Improvements were made to the back-up fuel oil system to assure smooth operation throughout the corning months. The department had two visitors from the National Institute of
Occupational Safety and Health (N10SII) on 11/22. biphenyl yields continued high as "Mono" residue is reworked to Aroclor 1254.
.DECEMBER
,
1016 soles fell off drastically this month. The 1 M lbs. production represents a three year low. At the same time, the 1.8M lbs. of Aroclor 1242/1254 produced was a record high since going to a 5-day rate in May, 1972. Pyranols continued aL a high pecc.
The south deportment settling basin and trenches were cleaned
12/26. 54,200 lbs. of Monochlorobipheny 1 from the September/ October demonstration run was shipped to Dow 12/26.
HQU$ 055814
JL*..?.*. Boucher, .WOK______ __ _
January 31, 1974
STATUS OF 246/259 PROCESS SAFETY AUDIT
________ _ ____
Dale J. Schilllnger
Virgil Brawley Bob Eden bill Engman Gary Johnson
On 12/12/73 we reviewed the Aroclor Process Safety Audit job list. We completed four of twelve high priority Jobe in 1973 and plan to complete the re maining high priority jobs In 1974. Here is the job Hat Including status and group assigned responsibility for action.
GENERAL RECOMMENDATIONS:
1. Pressure alarm for N2 blanketing.
Statue: W.O. issued Oct. 11, 1973
Responsibility: Instrument Shop/Production
2. Give men additional protection when working on lean-to roof.
Responsibility: Maintenance
3. Check aluminum storage tank thickness on tops.
Status - Done (SIAM program)
SAFETY JOBS
1. Replace air unloading of Biphenyl with pump.
Priority: High
Statue: One of the unloading systems will be replaced.
Responsibility: TSD will provide estimate and design.
2. Equip West Biphenyl Feed Tank (1-702) with Flame Arrestor
Priority: Medium
Status/Responsibil1ty: Will be handled by Maintenance.
HONS 0558X5
STATUS OF 246/259 FROCESS SAFJXY.AILDLT
rage 2 1/31/74 WCK
S_AFKT_Y_ JOBS (Continued)
3. Install dip pipe on Biphenyl head tank (1-103)
Priority: Medium
Status: Remains to be done
Responsibility: Maintenance/Production
4. Cool biphenyl in catalyst mix tank (1-403)
Priority: High
Status: Production will look into putting socks on line tracers to prevent overheating.
5. Provide non-metallic funnel on 1-403.
Priority: High
Responsibility: Maintenance/Production
6. Vent catalyst mix tank to West biphenyl storage tank.
Priority: High
Statue - Maintenance will estlamte
Responsibility: Maintenance
7. Move catalyst mix tank pump to ground level.
Priority: High
Status: Design and estimate needed.
Responsibility: TSD will handle.
8. Provide alterations to the chlorine vaporiser vent system.
Priority: High
Status - Need specification for chlorine relief valve and project estimate.
Responsibility: TSD will handle.
9. Install relief valve in steam line after pressure regulator to protect against high chlorine temperature.
Status : Done .
HONS 055816
STATUS OF 246/259 PROCESS. SAFETY _AUDJT -........... .. ............'
Page 3 1/31/74 WGK
SAF15TV .jdW- (Con t ' d) 10. Drains for process pump - Items 121,122,123,124,125,127,325,
306,313 Priority! Medium Status! This Is in progress.
Responsibility: Maintenance/Production 11. Reduce high temperature alarm In chlorinator off-gae header
from 190*C to 150*C. Priority! High Status! Done 12. Check 02 intermediate tank top thickness, provide access platform. Priority! High Status: Thickness check, needs platform Responsibility: TSD 13. Turn vent discharge on 03 Still Receiver Priority: High Status: Done 14. Move start-stop button away from column pot circulating pump.
Priority: High Status: W.O. 70766 Issued to Electrical Shop Responsibility: Production/Maintenance E61 Shop
15. Reduce Montar Drum Handling Priority! High Status: Trailer purchased for handling Montars Responsibility: TSD/Production
HONS 05561?
STATUS OP 246/259 PR0C_E_SjL SAFETY AUDIT
SAFETY. JOBS (Con t' d) 16. Provide furnace controls on 02 Still
Priority; High Status: Project package Issued 1/30/74 Rea pone 1bi11ty : TSD/Ma1ntenance
Page 4 1/31/74 WCK
/tm
Kenneth E. Boucher Technical Services Department
HONS 035616
COMPANY
CONFIDENTIAL
1975 MANUFACTURING IMPROVEMENT PLAN
FOR
AROCLORS AND PYRANOLS
DEPARTMENTS 246 AND 259
Prepared By: fl .'ifta*; K, E. "Boucher
Issue Date:
3/5/75
APPROVED:
! . , ' /,. ./ ' A7T7 lEisr
}//;
'/
fa' C . *//)** i y f t.S RTT. Engm^n
'S' s'
G. X,"Geers
HONS 055819
&1SIR1MLLQN
B, C. Bosse
K. E, Boucher
w, P, Conant
,
C. N, Deubner
R. Eden
V!. C, Engman
R. Flint
G. J, Geers
R, L, Heider
H. J, Horner
.
G. L, Johnson
R. H. Kountz - FANA
VI, A, Kuhn - B3NA
A. E. Leisy
D, K, Lynch
R, H, Munch - TIB
C. Paton - B2SC
E. M. Potter - P2NK
VI. R. Richard - T3A
J. R, Savage - B2SL
G. , V'atson
HONS 055820
TABLE OF CONTENTS Summary ................................................................ 1 Detailed Work Plan..................................... 2 General Plan:
A. Capacity Requirements . . 7 B. Cost............................................................9 C. Cost Improvement............................ 9 D. Pollution Control .... 11 E. New Products.................................... 11 P. Process Control..........................11 G. Plant Improvement .... 12 H. Safety....................................................12 I. Energy Conservation ... 12
HONS 055821
MANUFACTURING IMPROVEMENT PLAN FOR AROCLORS AND PYRANOI.S DEPARTMENTS 246 AND 259
Page 1
1-75 WGK
SUMMARY
Based on the sales and use forecast of 12-31-74, the department will have adequate capacity in 1975. As in 1974 there remains the potential problem of excess volume of residue from MCS 1016 production versus sales needs for Aroclor 1254 which is produced from this residue.
Forecast for 1976 indicates a major reduction in the capacitor (MCS 1016) market. Some equipment time will be available. Monochlorobiphenyl is the prime candidate to utilize the equip ment as MCS 1016 production requirements decrease. Monochlorobi phenyl is a new product not used in the capacitor field.
There will be a tight capacity situation in 1976 if MCS 1016 sales remain at the 1975 forecast level and Monochlorobiphenyl sales approach 8?j pounds annual rate in 1976.
Major technical effort in 1975 will be directed towards:
1. Completion of the Monoohlorobiphenyl project.
2. Continued reduction of PCB losses to the environment.
3. Technical assistance to customers for PCB pollu tion control.
Total technical effort for 1975 is estimated at 28 man months of which 13 man months will be process engineering. Capital for defined projects comes to $408,000.
HONS 055822
MANUFACTURING IMPROVEMENT PLAN FOR AROCLORS AND PYRANOLS DEPARTMENTS 246 AND 259
Pace 2 1-75 WGK
WORK PLAN FOR 1975
Potential I tenBenefits
I. COST IMPROVEMENT
Replace steel demister tank with polyester
Reduce down time & main tenance
Capital (Rough)
$13,700
Priority*
TSD Manpower (Man Months) Process Other
Installation in 1975
0
1
Responsible
Prod, TSD, Maint
II. POLLUTION CONTROL
A. Continue study of PCB removal
B. Visit customers* plants to provide assistance
C. Install interlocks on column vent condenser
3 z co
o v a> f\J u>
Environmental control of PCB* s
Environmental control of PCB * s
Environmen ta1 control of PCB's
$5,000
Continued Evaluation
Design Com plete
Total
$5,000
3 1 0 4
Priority 1 - Design will he completed in 1975 Priority 2 - Desicn will he completed in 1975 mainpower permitting Priority 3 - Backlog
0 TSD, AR&D, Research
0 TSD
0 Maint
0
1 1
MANUFACTURING IMPROVEMENT PLAN FOR AROCLORS AND PYRANOLS DEPARTMENTS 246 AND 259
Page 3 1-75 WGK
WORK PLAN FOR 1975
TSD Manpower
Potential
Capital
(Man Months)
ItemBenefits(Rough)______ Priority*Process Other______Responsible
III. NEW PRODUCTS
A. Demonstrate isomerization and prepare project for Monochlorobipheny1
B. Install absorber for new MCS 1489 blend
C. Investigate selling MCS 1016 distilled residue
New sales, re duce fixed and budgeted costs from MCS 1016
$350,900
1
New sales
S 20,000 Undetermined
Reduce pro duction costs
make product more accept able to cus tomer
Investigate
3
1 1
* TSD, Prod, Research, Maint
2 TSD, Maint
0 Prod, Marke ting
Total
$370,000
'
11
HONS 0 5 5 8 2 4
Priority 1 - Design will be completed in 1975 Priority 2 - Design will be completed in 1975 manpower permitting
Priority 3 - Backlog
MANUFACTURING IMPROVEMENT PLAN FOR AROCLORS AND PYRANOLS DEPARTMENTS 246 AND 259
WORK PLAN FOR 1975
Pace 4 1-75 WGK
TSD Manpower
HONS 0 5 5 8 2 5
`Priority 1 - Design will be completed in 1975 Priority 2 - Design will be completed in 1975 manpower permitting Priority 3 - Backlog
MANUFACTURING IMPROVEMENT PLAN FOR AROCLOES AND PYRANOLS DEPARTMENTS 246 AND 25?
WORK PLAN FOR 1975
Potential
Capital
Pace 5 1-75 WGK
TSD Manpower (Man Months)
HONS 0 5 5 8 2 6
Priority 1 - Design will be completed in 1975 Priority 2 - Design will be completed in 1975 manpower permitting Priority 3 - Backlog
MANUFACTURING IMPROVEMENT PLAN FOR AROCLORS AND PYRANOLS DEPARTMENTS 246 AND 259
WORK PLAN FOR 1975
Item
Potential Benefits
Capital (Roucrh)
VII. ENERGY CONSERVATION
A. Improve furnace efficiency Reduce energy consumption
B. Reduce steam usage
Reduce energy consumption
Priority*
Pace 6 1-75 WGK
TSD Manpower (Man Months) Process Other
Resoonsible
k 0 Prod, Maint 1 0 Prod, Maint
Total
1% 0
Total Work Plan
12 3/4
15%
MONS 0 5 5 8 2 7
Priority 1 - Design will be completed in 1975 Priority 2 - Design will be completed in 1975 manpower permitting
Priority 3 - Backlog
MANUFACTURING IMPROVEMENT PLAN FOR AROCLORS AND PYRANOLS DEPARTMENTS 246 AND 259
Page 7 1-75 WGK
A, CAPACITY REQUIREMENTS
Forecasted sales of Aroclors and Aroclor blends, through 1984, are shown below. The figures wore obtained from the M1CC Production Plan dated 12-31-74. The forecast for Aroclors includes the Aroclor needed to make the var ious blends.
Sales and Use Forecast for Aroclor Department (Mlb/yr)
Product
1975
1976
1977
1979
1984
i) 1016 2) 1221
3) 1242 4) 1254 5) Monochlorobiphenyl
28.20 0.15 7.53
10.00 0
23.00 0
6.58 8.83 8.00
19.06 0
6.68 7.89 9.00
14.35 0
6.16 7.76 15.00
14.30 0
4.14 6.39 20.00
Sales and Use Forecast for Aroclor Blend (Mlb/yr)
Aroclor Blend
Aroclor Used
1975 1976 1977 1979
1) Inerteen 54201 CM
1242
7.46 6.52 6.61 6.10
2) Pyranol A-13B3B-3
1254
0.95 0.76 0.67 0.70
3) Inerteen 70/30
1254
5.65 5.01 4.67 4.51
4) Aroclor 1469
1016
0.09 0.45 0.45
0
1984 4.10 0.70 3.64
0
The following lists the present production capacity of the department.
Product
Capacity
1016
50.4 Mlb/yr
1221 1242 1254
21.6 Rlb/yr
Aroclor blends
20.3 Mlb/yr
MONS 053626
MANUFACTURING IMPROVEMENT PLAN FOR AROCLORS AND PYRANOLS DEPARTMENTS 246 AND 259
Page 8
1-75 WGK
A. (Cont'd)
Based on the Sales and Use Forecast of 12-31-74, the depart ment will have adequate capacity to meet expected demands for 1975. In 1976 the department will likely begin the pro duction of 8M lb/yr of Monochlorobiphenyl. To achieve this production the Monochlorobiphenyl project will:
1. Increase the continuous ehlorlnator capacity by providing larger Cl2 control valves.
2. Debottleneck the Aroclor column by removal of the . blanking strips.
3. Activate the II still to provide isomerization
facilities for converting Mono column residue into
Aroclor 1242.
-
4. Revamp the existing blow tanks to provide hold tanks for lime treatment of the Aroclor 1242.
5. Provide new central instrumentation for the Aroclor column to automate Monochlorobiphenyl distillation.
In specification Monochlorobiphenyl was produced in the September, 1974, department demonstration. Also, column still bottoms were collected to be used early in 1975 for a department demonstration of the manufacture of Aroclor 1242 from Mono residue. During the demonstration, only 60% of the column design capacity could be achieved due to severe vibration in the still pot as boil-up was in creased. Causes of the vibration are being investigated as the plant scope is being prepared.
The same equipment will be used for MCS 1016 and Mono-
chlorobiphenyl production. Equipment occupancy in 1976 is
given below:
Annual Month
Product
Capacity
Occupancy in 1976
MCS 1016
5.4 M lbs/mo.
4.3 mo. g 23M lb/yr
Monochlorobiphenyl 1.4 M lbs/mo. Total Occupancy
5.7 mo. e 8R lb/yr 10.0 months
HONS 055829
MANUFACTURING IMPROVEMENT PLAN FOR AROCLORS AND PYRANOLS
DEPARTMENTS 246 AND 259
Page 9 1-75 WGK
A. (Cont'd)
The 12-31-74 forecast for 1976 is considered conservative in that 1016 sales could continue at the 1975 level of 28.2 R lb/yr. In this case equipment occupancy would be 11.2 months. This would leave little time for product changeovers.
Another problem associated with making Monochlorobiphenyl is the residue disposal route. When making Mono, only Aroclor 1242 is made using the column residue. Likewise, when MCS 1016 is made, only Aroclor 1254 is produced from the column residue. There will bo few exceptions, other wise an imbalance may be produced causing additional production delays.
Analysis of equipment occupancy shows additional facilities for Monochlorobiphenyl may be needed in 1978.
Equipment Occupancy thru 1984 (Months)
Product 1016
Rate 5.4R 4/Mo.
1976 4.3
1977 3.5
1979 2.6
1984 2.6
Monochlorobiphenyl
1.4M I/Mo.
5.7
6.4 10^.1 14.3
Total Months
10.0
9.9 12.7 16.9
B. COST
The following is the budget total bulk production cost for 1975 as Of 8-26-74:
MCS 1016 Aroclors Pyranols
21.734/lb. 21.174/lb. 26.534/lb.
C. COST IMPROVEMENT
The existing steel demister blow tank will be replaced with polyester material to reduce maintenance cost and downtime.
HONS 055830
Page *0
PROJECT
Replace Blow Tank Penister
GROSS ANNUAL SAYINGS RATE
$ 9,300
1st JL 0
1975 COST IMPROVEMENT
2ad Q $2,500
3rd 0. $ 800
4th .& $ 3,100
UNBUDGETED CURRENT TEAR EXPENSE______
0
ESTIMATED CAPITAL REQUIREMENT
$13,700
EDC 9/1/75
ODDS or SUCCESS
952
HONS 055831
MANUFACTURING IMPROVEMENT PLAN
FOR AROCLORS AND PYRANOLS
DEPARTMENTS 246 AND 259
____
Page 11 1-75 WGK
D. _POLLUTION CONTROL
Monitoring and control ot PCB losses to the sewer will con tinue. Current losses from the Aroclor department and the incinerator are below the target of 1 l/day. Federal regu lations have not been promulgated as yet, but may be 0.541/day excluding background. Technical effort may be required to develop means to reach this level on a consistent basis if 0.54.(l/day becomes law.
TSD and Research will continue to evaluate various adsorption media for PCB removal from the department effluent. Such a study may prove useful in also finding ways to remove PCB's in effluent discharges from our Aroclor customers' plants.
At the request of the E1A (Electronic Industries Association), TSD 1b visiting each capacitor customer and obtaining the following samples for PCB content.
1. Samples of each plant's effluent.
2. Samples of the water used by each plant.
3. Samples of the body of water into which each plant discharges its waste streams.
Installation of a newly-designed temperature interlock for the Aroclor 1016 column vent condenser will be installed to further reduce the chance of discharging vapors containing PCB's to the atmosphere.
E. NEW PRODUCTS
In 1976, the department is expected to begin Monochlorobiphenyl production. The production of 8M Ib/yr of Monochlorobiphenyl should result in a cost divisor savings of $125,000/yr in the production of Aroclor 1016 by spreading the base for fixed and budgeted costs.
New capital may be needed to make MCS 1489 in the department. MCS 1489 is a blend consisting of 10% by weight Tolylxylsulfone mixed into Aroclor 1016.
F. _PROCESS CONTROL
Work may be needed in 1975 on altering the chlorine distribu tion among the four continuous chlorinators to reduce the amount of high boilers.
HONS 055832
MANUFACTURING IMPROVEMENT PLAN FOR AROCLORS AND PYRANOLS
DEPARTMENTS 246 AND 259
Pane 12 1-75
WOK
F. PROCESS CONTROL (Cont'd)
A cooperative effort between production and AR t D is needed to identify the cause of the change in the fluorescence color of Aroclor 1016. The General Electric Company of Hudson Falls noticed this change.
Hydrodechloriantion process now under study by Research is the dechlorination of Aroclor by catalytic hydrogenation to recover the Biphenyl value of the residue. Hydrodechlori nation appears to be the most promising use of the MCE 1016 distilled residue should loss of the 1242/1254 market occur. Major drawbacks to the hydrodechlorination route is the high capital ($1M +), and the generation of dissolved solids (NaCl). Further studies will be conducted by Research.
The column still fuel oil control system will be revised in 1975 to be capable of operating at various rates.
To reduce corrosion of the crude storage tanks, air blowing of the crude Aroclor 1142 has been resumed. Technical effort may be needed if increased PCB losses are caused by air blowing.
G. PLANT IMPROVEMENT
Two carryover projects are includedi
1. A project is needed to simplify the handling of bagged lime.
2. The area between the department and the railroad tracks Bhould be paved.
H. _SAFETY
Two safety items from the safety audit remain to be completed. In addition, two additional items have been added. They arei
1. Provide Biphenyl unloading pump.
2. Replace rupture disc on the chlorine vaporizer with a relief valve.
3. Install automatic Clj shut off on the chlorine header in case of an electrical failure.
4. Replace top of 42 intermediate storage tank and provide a platform.
MONS 055833
MANUFACTURING IMPROVEMENT PLAN FOR AROCLORS AND PVRANOLS
DEPARTMENTS 246 AND 259
Page 13 1-75 WGK
I. ENERGV CONSERVATION
To conserve energy, effort will be directed towards two i terns i
1. Improving the efficiency of the furnaces in the depart ment by changing the air throughput to obtain maximum flame temperature.
2. Reducing steam usage--an item which is being done on a plantwide basis.
MONS 055634
STANDARD MANUFACTURING PROCESS PYRANOLS & INERTEENS DEPARTMENT 259
(tb "7*-C
HONS 055734
MONSANTO COMPANY SPECIALTY PRODUCTS DIVISION
STANDARD MANUFACTURING PROCESS FOR
PYRANOLS, DEPARTMENT 259 1NERTEENS, DEPARTMENT 259
SUPERSEDES:
STANDARD MANUFACTURING PROCESS FOR THE MANUFACTURE OF PYRANOLS AND INERTEENS IN DEPARTMENT 259, DATED DECEMBER, 1970, AND ALL AMENDMENTS.
PREPARED BY: G. L. JOHNSON
APPROVED BY:
\
ISSUED: SEPTEMBER, 1979 COPY ^ OF \4
W.R. RICHARD, RESEARCH
c------- ' >i( ' Ui J. R. SAVAGE ,MAn()>^cTJR 1NG MANAGER
This process is the property of the Monsanto Company and the recipient le responsible for ite safekeeping. It contains confidential information of Monsanto Company which must not be reproduced, revealed to unauthorised persons or sent out side the company without proper authorization. Either retain in a secure file or return to the Standard Documents Department.
MONS 055735
DISTRIBUTION SHEET
1. TECHNICAL INFORMATION CENTER 2. TECHNICAL INFORMATION CENTER 5. RECORD CENTER 4. MANUFACTURING MANAGER 5. MANUFACTURING SUPERINTENDENT - W.G.K. 6. W.G.K. DEPARTMENT SUPERVISOR 7. W.G.K. TECHNICAL SERVICES DEPARTMENT 8. W.G.K. PROCESS RESEARCH 9. W.G.K. LIBRARY 10. D. DANNA - G.O. 11. D. DANNA 12. D. DANNA 13. EXTRA 19. EXTRA 15. EXTRA 16. EXTRA
MDNS 055736
AMENDING RECORD SHEET MOWS 055737
TABLE OF CONTENTS
SECTION 1 SECTION II SECTION III
SYNOPSIS OF PROCESS PROCESS FLOW SHEET PROCESS IN DETAIL
SECTION IV APPENDIX A APPENDIX B
APPENDIX C APPENDIX D APPENDIX E APPENDIX F APPENDIX G APPENDIX H APPENDIX I APPEND1X 0 APPENDIX K APPENDIX L APPENDIX M APPENDIX N
COMMENTS ON PROCESS EQUIPMENT LIST FINISHED GOODS AND RAW
MATERIAL SPECIFICATIONS PHYSICAL CONSTANTS UTILITIES PERSONNEL PACKAGING AND SHIPPING MATERIAL BALANCE PRODUCT LOSSES PROCESS CONTROL SAFETY AND TOXICITY BACKGROUND INFORMATION TIME CYCLE AND CAPACITY QUALITY CONSIDERATIONS MISCELLANEOUS
MQNS 055738
DEPARTMENT 259 - STANDARD MANUFACTURING PROCESS PYRANOLS. INERTEENS
Page 1 9/74
WGK
SECTION I
SYNOPSIS OF PROCESS
Pyranol and Inerteen are trade names used to designate mixtures of Aroclor and Trichlorobenzene (TCB). A chloride scavenger, phenyl glycldyl ether or Unox Epoxide 221, (EPON 4221) is also added.
Pyranols are used as a dielectric In electrical equipment (transformers), and particularly as a transformer cooling medium. The addition of TCB to the Aroclor Increases fluidity of the blend at only a slight expense to its electrical proper ties. Extreme care Is used In the production of Pyranol blends because the customer specifications are very stringent.
At the present time, three electrical grade blends are made. They ares
Common Name
Other Names
1. Inerteen 54201 CM 2. Inerteen 70/30
3. Pyranol A13B3B-3
Inerteen 100-42, 1242 PP0
Iner teen 54201 KA, 1254 PPO --
The proportion of components blended to manufacture the various blends are listed below:
Wt. X Product
TCB Aroclor 1242
Aroclor 1254 Unox Epoxide Clycidyl Phenyl
Ether
Inerteen 54201 CM
___ 100 -- --0.20
Inerteen 70/30
30 -70 -0.20
Pyranol A13B3B-3
40 --
60 0.125
'-
Primary chemical reactions are absent in the production of
these blends, The manufacturing steps are blending, earth
treatment and filtration, and packaging.
Blending Is a simple mixing operation. Small adjustments are necessary until proper specific gravity and refractive index are obtained. To improve electrical properties, a small amount of attapulgus earth nay be added to the blend and subsequently
filtered out. The electrical grade products are sold in tank cars, tank trallera, or In drums of 55 gallon and 5 gallon.
HONS 055739
DEPARTMENT 259 STANDARD MANUFACTURING PROCESS PY RANOLS, INERTEENS
Page 2 9/74 WCK
SECTION I - SYNOPSIS OF PROCESS (Continued)
The Pyranol trade name Is used by the General Electric Corporation and Inerteen by the Weatlnghouae Electric Corporation.
HONS 055740
DEPARTMENT 259 STANDARD MANUFACTURING PROCESS PYRANOLS. INERTEENS
Page 3 9/74 WGK
SECTION II
FLOW SHEETS
Flow eheete for the blending operations are highlighted
on the following department drawings, (Flow .diagrams
will follow when they become available. )
HONS 055741
DEPARTMENT 259 STANDARD MANUFACTURING PROCESS PYRANOLS, INERTEENS__________
III-l. 9/74 WGK
SECTION III
PROCESS IN DETAIL
A. BLEND CALCULATION
The first step in making a blend is to determine the batch size desired and the weight of each major component based on the percentages listed In Section I. Using these weights, and the known specific gravity and refractive Index of both the Aroclor and Chlorobenzene, the theoretical S.fi. and index of the blend Is calculated. This Is done simply by weighted averages. By trial and error, the ratio of the major components is shifted slightly, if necessary, so that both specific gravity and refractive index will be as near as possible to the middle of their respective specification ranges.
B. BLENDING
The major raw materials are pumped to the mix tank (#2, #3, or 04), the Chlorobenzene first. This Is to avoid the more viscous Aroclor from clinging to the walls and bottom of the tank. The mix tank contents are agitated for at least four hours after the major components have been added. The blend is heated to 90-100*C during this time. A 16 ounce control sample la taken for S.G. and index. If adjustments are needed, they are calculated in the same way as the original batch. Once S.G. and index are in spec., the chloride scavenger (glycldyl phenyl ether or unox epoxide) is added based on the total batch weight.
C. EARTH TREATMENT AND FILTRATION
After agitating for another 4 hours, a final sample of three 4-pint bottles is taken. If all analyses are in specification, and the power factor at 60 cycles is under 1,5% and the resistivity is at least 1500 x 109, then the product is ready for packaging. (These quality levels have been set within the department.) If this quality is not met, then 20-25 lbs. of attapulgus earth may be added to the blend, agitated for 4 hours, and circulated through a filter for 1-2 hours. Samples are taken and re-analyzed for electrical properties. This earth treatment step can be repeated as often as necessary. The 1.5% power factor and 1500 x 109 resistivity levels were set for efficiency of operation only (See Cl in "Comments on Process" section.) The critical analysis is the tank car analysis.
MONS 055742
DEPARTMENT 259 STANDARD MANUFACTURING PROCESS PYRANOLS,_IN_ERTEENS
111 - 2 . 9/74 WGK
SECTION 111 - PROCESS IN DETAIL (Continued)
D, PACKAGING
Ae an environmental preventive measure, heavier gauge drum's with special labeling were put into all Pyranol/ Aroclor service in early 1973-. The drums are of 16 gauge, double chime construction with an all yellow exterior. A silk screen, seven language logo-is printed on each drum. This warns the customer of the relative hazards of PCB's and Instructs them on proper handling and use. In addition, each product label indicates proper disposal method through Incineration at the Monsanto W.G.K. facility. See Appendix F for container sizes and product weights.
When shipping product via tank care or trailer, product samples are taken from the car or trailer and an analysis run. If a certificate of analysis Is requested, this la the one used. Drum samples are not taken, but merely Identified by lot numbers which correlates to a mix tank analysis. Ae a further step to reduce the potential of PCB's reaching the environment, bulk shipping via trailers is discouraged. The preferred method is by tank cars or drums.
During the drumming operation, a 4 pint grab sample is taken for appearance, moisture, and electrical properties only, and the drums identified by lot numbers which correlates to a mix tank analysis.
MONS 0557*3
DEPARTMENT 259 STANDARD MANUFACTURING PROCESS PYRANOLS, INERTEENS _________ _____
1V-1 9/74 WGK
SECTION IV - COMMENTS ON PROCESS
A. RAH. MATERIAL YIELDS
In calculating yields, the Aroclor yield is assumed to be 100% and the Chlorobenzene yield calculated on that basis. Therefore, minor losses will show up as Chlorobenzene yields less than 100%. Actual material losses are very small, an estimated 0.04%. Very email losses occur at the mix tank vents, leaking pumps, and In discarded filter cartridges. The only significant loss occurs when a tank car la over filled. A collection system and settling basin prevent this material from reaching the sewers and environment. A yield lose (but not a material loss) occurs when drums are filled to more than the indicated net weight.
Chlorobenzene yields do not necessarily reflect only the above mentioned losses. The yields also reflect the specific gravities snd refractive indices of the Chlorobenzenes and the Aroclora. This la because the finished product la made to meet certain specification ranges, not s certain weight ratio. Therefore, it is possible to have below 100% Chloro benzene yields even with no material losses. Likewise, yields over 100% can be legitimate and do occur.
Prior to 1974, tri-tetrachlorobenzene (TTCB) was used as a raw maierial in A13B3B blends rather than TCB. The use of TTCB in Pyranol blends was discontinued in late 1973 when the existing A13B3B-3 blend was developed.
B. CAPACITY
The rated monthly capacity of Dept. 259 for producing Pyranols is 1.69M lbs. The record level of production to date was In January, 1974, when 2*30M lbs. were produced. A more "normal" level is 1.0-1.3M lbe/mo. Past difficulties In obtaining an adequate supply of chlorobenzene have occasionally hampered production. Three mix tanks are available for making the three Pyranol blends. These tanks are also the only storage capacity, although the No. 10 storage tank has been used to provide temporary surge capa city for Inerteen 70/30 on occasion. The present uses ores 02 mix tank - A13B3B-3; 03 mix tank - 70/30; 04 mix tank 54201 CM.
ftONS 05574*
DEPARTMENT 259 STANDARD MANUFACTURING PROCESS PYRANOLS, INERTEENS
1 V-2. 9/74 WOK
SECT1 ON IV - COMMENTS ON PROCESS
B. CAPACITY (Cont'd)
A few minor points:
1. The mix tanks should be agitated and circulated while charging as well as afterwards to reduce actual blending time. If this 18 done, It was decided after evaluation that an in- line stationary mixer was not needed.
2. There are no problems in making a batch on top of a heel. At times this can be done advantageously in order to get to the next batch more quickly.
C. QUALITY
Quality is singularly the most Important consideration In the production of electrical grade blende. The production of off-grade blends has resulted in much controversy, extended correspondence, and chemical research. No attempt will be made to cover the entire scope of the quality prob lem. Some of the factors related to quality are discussed briefly
1. Electrical Properties - A rather arbitrary "mix tank spec!fleation" has been observed by the department for power factor 0 60 cycles and resistivity. This is a maximum of 1.5X power factor and a minimum of 1500 x 10 resistivity. This is more stringent than the formal plant specification because these two analyses must be in specification jjn the tank car. Normally these electrical properties drop when pumping from tank to tank, or tank to car. The reason for this la unknown, but the suspicion Is always contamination. It 18 also recognised that proper sampling is extremely Important.
2. Moisture - The moisture content of Pyranol and Inerteen batches can be reduced to 10-15 ppm by blowing the batches with N2 supplied by Dept. 246. In the blowing operation, the batch should not be heated above 100C for prolonged periods to prevent TCB vaporization losses. The vapori zation loss of sufficient TCB may throw the blend out of specification on specific gravity and refractive Index and require a TCB adjustment.
Pyranol8 and Inerteens have an affinity for moleture. Tanks and containers should be kept closed when possible.
HONS 055745
DEPT. 259 STANDARD MANUFACTURING PROCESS
PYRANOLS. INERTEENS
IV-3. 9/74 WGK
SECTION IV - COMMENTS ON PROCESS
C. QUALITY (Cont'd)
2. (Cont'd)
When a low moisture content has been achieved and the material Is to be drummed, a high temperature (120C140*0 Is better for maintaining the low H2O level than Is continued blowing with N2* It should be noted, however, that if the drums or cans are quite full at normal temperatures, at the higher temperatures the required net weights may be difficult to obtain.
3. Attapulgus earth tends to remove a small amount 1 scavenger In a batch. if a batch Is extensively earth treated after the scavenger has been added there should be a final re-analysis for the glye phenyl ether. The only known way of removing e; scavenger is by earth treatment or by lowering percentage by compositing a larger batch.
4. Chloride Scavenger - Many of the Inorganic chloride troubles of the past have been traced to the chloride scavenger. Tin tetraphenyl is no longer used as a chloride scavenger because the mixes would not pass the 0.1 ppm Inorganic chloride specification in many Instances. Unstable glycldyl phenyl ether has been responsible for off-grade Inerteen in the past. Inerteen batches with chloride concentrations as high as 0.30 ppm have been successfully treated to reduce the chloride concentration to 0.1 ppm by the addition of 10-20 pounds of Attapulgus earth to the mix tank and circulating the batch through the filter.
5. Raw Material Stability - During 1947, considerable difficulty was encountered producing Pyranols that would pass the 0.1 ppm specification on Inorganic chlorides. After extensive research work, the difficulty wae traced to the Instability of the raw material trichlorobensene.
6. Since roid-1973, the number 5 Porocel absorber has been used to upgrade TC6 prior to blending. An evaluation Is presently underway to determine if this practice has significantly Improved the properties of the final blends. There is some evidence that the frequency of earth treating batches has decreased since Porocel treatment of the TCB had begun.
0NS 055746
DEPARTMENT 259 STANDARD MANUFACTURINC PROCESS PYRANOLS, INERTEENS
IV-4 . 9/74 WGK
SECTION IV - COMMENTS ON PROCESS
C. QUALITY (Cont'd)
At the present time, so many variations in the final analysis are experienced that it is virtually impossible to track down where the electrical properties degrade. The variations are probably due to sampling variances, bottle contamination, atmospheric contamination in plant and laboratory, and personal analytical techniques.
MOtiS 05S?*?
APPENDIX A APPENDIX B
C D E F G H 1 J K L M N
EQUIPMENT LIST SPECIFICATIONS PHSYICAL CONSTANTS UTILITIES WORK SCHEDULE DRUM STOCK MATERIAL BALANCE PRODUCT LOSSES PROCESS CONTROL SAFETY AND TOXICITY BACKGROUND INFORMATION TIME CYCLE QUALITY CONSIDERATIONS MISCELLANEOUS
HOMS 055748
DEPARTMENT 259
PYRANOLS AND INERTEENS
APPENDIX A - EQUIPMENT LIST
item
.NOjl.
equipment name
equipment number
142 01 Blend Tank Motor
21-0779 52-56134
143 02 Blend Tank Motor
144 Blend Tank Pump Motor
21-1399 52-56134
52-02680 52-56409
145 Blend Tank Filter
152 05 TCB Stg. Tank 21-1310
153 05 TCB Stg. Tank 19-0929
Pump Motor
66-0856
154 03 Mix Tank Speed 21-03526
Reducer Motor
52-87054
52-56409
155 01 Mix Tank Pump 19-3172
Motor
66-2651
159 01 Mix Tank
21-01321 52-82562 52-56209
DESCRIPTION
Tank made by Graver. Dwg. E-862. Welded 6teel tank, 7' dla. x 7'high, dished heads 1/2", shell 3/8". All surfaces sprayed with .005" tine, then .003" tin. 2" xHy pipe coll. Cast bronze stirrer and bronze shaft. Test pressure of tank Is 600 hydo., coll ie 300 hydro, pressure. Capacity 2,000 gals.
Same as Item 142.
Durco Mark II-> Group II, as casing and Impeller (10-1/2"), Crane 9 mechanical seal. Lincoln 10 HP motor, 1800 rpm.
Alsop filter Model No. PAK 125-4, 316 bs, 6000 In filtration area, 840 In ^ volume.
Tank made by Leader Iron Works. C-609. 10' O.D. x 26' long on Str. side, dished heads, shell 1/2" head 9/16". Test of tank Is 600 and coll Is 3000 hydro pressure. All colls, supports, and inside surface sprayed with .005" zinc and .003 tin.
Taber submerged, vertical, centrifugal pump, model C-3, size 228. Pump Is 2-1/2 x 2 x 9, length is 138 inches. Base 3000 bronze casing and suction cover, bronze Impeller, and nickel/stcel shaft. Capa city Is 50 ppm $ 40* static head. Lincoln motor is 5 HP, 1445 rpm.
Alpha tank, 12'0" dla. x 22*0" high. Capacity Is 20,000 gallons. Mode of aluminum, see Dwg. TS-D-3011. Lighting agitator, Louis Allis 10 HP motor.
Durco, Model WHD2, 2 x 1-1/2 x 9.4/8; casing, cover and Impeller are alloy 20; capacity of 160 gpm @ 55' head. Motor le 1800 rpm.
Tank (Nooter), Dwg. D-6455, 14' O.D. x 10* high, 3/8" steel shell. Capacity is 13,000 gallons. Agitator motor is 7.5 HP, 1750 rpm.
MONS 055749
DEPARTMENT 239 - PVRANOLS AND 1NERTEENS
APPENDIX A - EQUIPMENT LIST
ITEM NO.
EQUIPMENT NAME
EQUIPMENT NUMBER
160 112 Mix Tank Pump Motor
52-02875 52-56409
162 06 TCB Stg. Tank 21-0868
163 06 TCB Stg. Tank 52-76527
Pump and Motor
52-56286
364 02 Mix Tank Speed Reducer Motor
165 03 Mix Tank Pump Motor
166 02 Mix Tank Filter
173 04 Mix Tank Filter
176 TCB and TTCB Unloading Pump Motor
178 04 Mix Tank Speed Reducer Motor
21-2621 23-4109 52-56259
52-02875 52-56409 15-0657
65-0769
52-77781
21-3656
179 04 Mix Tank Pump Motor
52-69960 52-56409
180 Filter at loading
-
dock 03, Track 10A
387 03 Mix Tank Filter
15-03338
DESCRIPTION
Durco 3 x 1-1/2 x 13/9.5, alloy 20 with external mechanical seal, motor la an Allis-Chalroers, 10HP, 1750 rpm.
Made by Graver, Dwg. E-4413, 8' ID x 25'6" long, horizontal and underground, internal eteam coil, capacity la 9500 gallons.
Vertical centrifugal pump, 2 x 1-1/2 x 990/9.0, length la 118 inches, cast iron casing, suction cover and Impeller, steel abaft. Lincoln motor Is 7.5 HP, 1740 rpm.
Steel tank, einc/tin lined, 10*6" I.T). x 23*0" high, capacity Is 14,800 gallons. Lightning mixer, 450 rpm, 3 bladed 18" impeller. Motor is 7.5 hp, 1800 rpm.
Same as Item 160.
Sparkler, 18*' diameter, 23 leaves, Model 18-S-23, all 304 ss construction.
Same as Item 166.
Blackmer, Model 3202, 2x2, all cast Iron construction, 5 HP motor.
Made by Missouri Boiler Co., 304 ss, 13'0" diameter, capacity of 20,000 gallons. Steam coll has 45 turns of 1-1/2" pipe. Lightning agitator is 18" in diameter and has 3 blades, 420 rpm. Motor is 10 HP, 1160 rpm.
Durco, 3 x 1-1/2, 13/9.5, Model A20.I, ductile iron casing and impeller, jacketed rear cover plate. Allis Chalmers motor Is 10 HP, 1750 rpm.
Same as Item 145
Same as Item 166.
HONS 055750
APPENDIX B SPECIFICATIONS
The following Is a list of the raw materials used for the manufacture of Pyranola and Inerteens. Specification sheets that are available are Included for the materials.
MATERIAL CODE
60200 61103 61325 81101 36100 19400 43101
RAW MATERIAL
Trlchlorobeneene Aroclor 1254 Unox Epoxide 221 Aroclor 1242 Glycidyl Phenyl Ether Attapulgus Earth Nitrogen
The following is a list of the finished products manufactured in Department 259. Specification eheete are Included.
PRODUCT CODE
PRODUCT
81110 81093 81096
Inerteen 54201CM Pyranol A13B3B-3 Inerteen 70/30
MONS 055751
> f................
Kj ununr id: ( Anniston RAW !'AT-Jt"C 1AL
SPliCIHSATION
TirooulTio..
mat ; ''i.-.i. c ci>r
r WC-A t; Ann. our tlTucT.vt
(1/13/6?
''
KP-Z21
U.IH. Ot <1 s.
A-2--6 W(/.K
27 A nr.
uf(`i.tr.M
Union Carbide
A.nj'RAVALS *tTCVi:V:TcT"----------
J. W. !<a_!un`
UUAi.IT V C C,WT AC.
n. Movers
G.W.Miller
$XX*^j!'rv> *
JO'iM-iiM-Bia .MTcVur
" Ummiom ANALVm
_____7/?J./fjh.................................. 1 - 16 or,. W M Bottle
f, KAfl AC r.n.n it
LIMIT 1
nigcior^n/st.iV/jr METHOD
U Nl< K !> rK1C T ED I \'F OR MA T ION
(10 Appca ranee
Clear liq., free from dirt fibers, or other contamination
'
13019
(K) Assay
88%, min.
13017
Color
150APHA, max.
i ooe-i
Total Free Chlorides
10 ppm, max.
13021
Refractive Index @25*C. Report
13020
Moistu re
0.1 %, ma x.
1062.0
Acidity
0.2 mg KOH/gm, max.
10087
Sp. Gr. @90/15. 5*C.
Report
13018
Supplier's certificate of analysis to'be sent on day of shipment to: Chief Chemist, Monsanto Co., Monsanto, 111,
OR Chief Chemist, Monsanto Co, , Anniston, Ala,
MONS 055752
no
. .... ; .
o <K4ir c>\: .`ic a*.a riv n KAW l/ATI-.niAL
SPliCinCATlON
II. H. Coj'.l i'V.'/k. McC'utchan
ti. U. l,oyv-r?o
SaESiUailM!.' tod
_______
Art c< i rc 11 v
2y
jjm/js.,
Hooker
.'.I'CIJOVAUS I'liTiTrircM-------------------
W. R. Richord
O.l * Ll V V COMI`101
R. M. Blowers
SSESiiikLkr-iilibi. C6U3OI.3
7yrfiTHaetr*M.cTur
1.1/20/C8 CHARACV f.niMtC
"
.AM.`.rroi`MrALlVi*
~`
_>,,r_5_tLt. .'"r.b.cxJtioillc'.s
LIMIT*
IMtHtOIV
~~ -
. S. Dhfui) t.fjr/C . f i ; MlTHOO
*
UNBKSTRICTSD INFORMATION
Color
APHA 15, max.
Condition
Clear
Sp, Or. @lb,5/l5.5c
1.46o - 1.J7T
Acidity (mg, KOH/g.)
0,014, max,
Moloture (HsO)
75 ppm,, max,
(H> Rofrr.ctivo Index @25C
1,5680 - 1.5715
Free Chlorides
0.10 ppm,, max.
Crystallising Point ,, 10C, max. Dielectric Strength 25C 30 KV, min,
Distillation Range (ASTM D-850,Modified)
(corrected for Stem and Barometric Pressure)
First Drop
50 by volume
205C, min, 210C, min,
50# by volume
213C, min.
90# by volume
215C, min.
Corronlon Tent, 6 hrs at
21CC Kith bright aluminum
foil Change In weight of A1
0.0#
Color
APHA 200, max.
Condition
Clear
Acidity (mg. KOH/g.)
0,014, max.
Freo Chlorides
0.10 ppm., max.
Monsanto Stability Test
0.5 ppm., max.*
Hydrolysis Stability Test 0.5 ppm., max,
Fire Point
Hone to boiling point
Fixed Chlorine
58.5#, min.
10105 10105
10100
10109 10620 10125 10118 1010',' 1160S 10108
10126
11503 12672 10123 10036
"livery other car can be over' 0,5 ppm but never over 1.0 ppm. Values over
0,5 ppm to be cleared in advance.
.
Certificate of Analysis required on the above properties - To be sent to the Chiof Chemist, W. 0. Krummrlch Plant to arrive on or before
rocoipt of shipment.
HONS 055753
J| */At M. eo,
I 43101 jvrv.'n--------
H AW MATERIAL SPECIFICATION
1....._\vok_ [7>ai t: r.i i tci i\ .Ji.
Sf.- I'cIvjw (3) Air Reduction Sales Co.
VsStrjcmJTT.1 -. ;\V , M.
y. w. i>.
.O.AL
AirnovALt 77.
7x711. Mills
01).: Ci.
KJ..M.________ ______ _ .1. A, S.
euALtt v cwnt.w. .hil Chn,iIn)
Ji-JLiU ......... ..................... . .........--
\V , J , Gi e.sliMiu
Grade - O. P. Special Nitrogen
VwiXtotYiru.' cm - . 2/18/65 ..........
AMiTLK fOH ArfAtr.,.
............... -
I.IMITI
Assay (1) Oxygen Hydrogen Dew Point
99. 9%, rnin. 0. 1%, max, 0% -76* t\
Nilrop.cn
A rgon Oxygen Carbon Dioxide Acetylene
------ i IMUCO v L, 1C. Hornbaek W.,,,SP
(7)
Typical Analysis 99. 78%
0. 12% 0. 1%
.00005% .00005%
(1) Nitrogen plus inert rare gases (2) Any analyses to be obtained from supplier on request.
(3) 213, 244, 246, 247, A-255, A-256, 259, 267, 270, 13-270 & 281.
HONS 055754
. .'.iv <.0 Ft A V/ MAT L! RIAL SFJi*Cli'10AVI0N
PKO<yftfMCNt
^-AMSLJLh'.
36 i 00 *" Ut WGK
Uiiwe 7it' t.
A - 2 46
"aATt'cT'MTcTi/ir'
luf'T'urn
7/.1.0/6<
Shell Chemical Co,
APPROVALS IlCII. AHCM
M. E. Gibbs OUAUTV CONTHCL (Chief Chewl>)
R. Blowers
CHEMICAL rpAMUlA
C91!]0O/
rnol w[. )SO,17 VJi* t i FiSm mYc5"u?
5/26/f'C
CHAAACIMUTIC
CUt-----CH-------- CHi ^C>
lAHMU VOH *M AL V111
1 x 16 ox, W.M. Bottle
IIIIU'.D to v
Uicjcjer son/St it:es
U NC LA SSI K; Jill') IN FOR MA T1 ON
(R) Sp. Gr. @20/206C, (R) Total Chlorine (as Cl ) GENERAL INFORMATION
1.105 - 1.115 40 ppm, max.
11,864 12,510
At the present time the material being supplied to WGK ior use in the manufacturing of Westinghouse Inertcen PPO, is a commercial Grade of Glycidyl Phenyl Ether. In addition to the 2 tests shown above, the supplier's specification lists:
Purity (Based on Epoxide Content, per cent by weight
. 98%, max.
--
Color
30 APHA, max.
--
The supplier's Technical Bulletin shows the following Physical Properties for the Refined Grade,
Boiling Point @ 760 mm. Melting Point Flash Point Refractive Index @20*C. Viscosity @20*C .
30*C,
245eC. 3,5eC, 175eF. 1.5314 7,05 cs. 4.88 cs.
11,862 11,861
11,863
Supplier's certificate of analysis to be sent on day of shipment to: Chief Chemist, Monsanto Co., Monsanto, 111,
fHJ Attulfn*
All ilhtr* "iilviif bv r*qu*( enFy.
HONS 055755
........ V ,
W, (i. Krui.-'i.irit h Plant RAW MATERIAL SPCCiriCATIOM
i'ii>huf i ion J VI. Uollpy
ii*oc iiinm uv J. Leyurle
oi:ni;i> ai oi'K'mum ion
wtO WGJ.C
Allup ul|;ua l.u'.JlIi 200/l)r
u.*imi nt p t.
246
2/3/6?.. APPnOVM. >
Mineral fcr. Chemical Phillip? Our;>,
Marvin E. O'bhr. IT v ea.j.er,, tChitt C Aft.iiiaO
R. Blowers
Ct I1MIC Al. l OHM'JL A
*l*4 riMMr* fi r or D/Pl/66
C HAN AC Y | ItllTIC
Clay
AMI'L* PON ANA 2 x 16 i>2. W.M I.IMI
Bottle s
IVSOCO V
Hlpuornnn/Tt'.t MKTMOO
UNRESTRICTED INFORMATION (R) Volatile Matter (at 950*C .) (R) Mesh Test:
Through USS 325
6- % 90%, min.
This material is not accepted without the supplie r's analysis of the above properties,
MONS 055756
Monsanto
Oil 0 A NIC CHEMICAL* DIVISION
W. G. Krummrich Plant FINISHED PRODUCT SPECIFICATION
*l\OUWt 1 ICM
A. tt. beisv
ALF.
C. Paton
Lam-isAor 1254 i:)'uu,oawetdcswX-;:..adgU. *C
W. G. K.
su&m___ f >M l> V III ncc/nc
A, lL81C1O.I'l J 040-
W. R, Richard
.h. Jv. Horner* CHEMICAL FOAM
Also called Pyranol 1476.
Lit'-_______
MOL *TT. Iufl'hlcoci *>r.c. OF
11/4/68
CHAHACTCnitTIC
UNRESTRICTED INFORMATION
IA."'Lt FOn ANALVIll
3 x 4 Pt. Amber Bottles
LIMIT*
iffueo *v
R. McCutchan/S.Shauiter
MCTHOO
(R) Color, APHA (R) Condition (K) sp. Gr. e 65/15.5C. (R) Acidity (mg. KOH/gm.) (R) Moisture (HjO) (R) Refractive Index @ 25C. (R) Inorganic (Free) chlorides
(R) Pour Point (R) Dielectric Constant
(60 cycles (? 100C.)
(R) Hydrolysis Stability Test (As Chlorides)
(R) Monsanto Stability Test (As Chlorides)
50, Max. Clear 1.495 - 1.505 0.010, Max. 3 5 ppm., Max. 1.6375 - 1.6415 0.05 ppm., Max. 7 - 12C. 4.25 - 4.55
1.0 ppm., Max.
0.5 ppm., Max.
10,084 10,084 10,114 10,087 10,020 10,125 12,741 10,115 T-2273
12,672
11,503
(R) Distillation Range (ASTM D-20, Corrected) 10% Distilled b y Wt.
50% Distilled by Wt. 90% Distilled by Wt.
366 - 378C, 371 - 383"C. 379 - 394"C.
10,117
Sulfates
Dielectric Strength 25c,
Flash Point
Fire Point
Vise. @ 210F.
Corrosion Test
(6 hrs. @ 210C. with bright
Aluminum Foil.)
Change in wt, of A1 (%)
A.C. Color, APHA
.
A.C, Condition
A.C, Acidity (mg, KOH/g.)
A.C, Inorganic (Free) Chlorides
None 35 KV, Min. None None 44 - 48
0.0 60, Max. Clear 0.010, Max. 0.05 ppm., Max.
12,169 11,605 10,123 10,123 10,086 10,126
10,084 10,084 10,087 10,118
Internal Customer
(R) Power Factor @ 100C., 60 cycles, Max.
Bulk Drums
0.5% 2.0%
1.0% 4.0%
T-2273
(HJ KiUttihf Analytic, All otbtu Analysed by ttqm st Only
CONTINUED PAGE 2
HONS 055757
Characteristics
GENERAL INFORMATION
Specific Heat i? 25C. Coefficient of Expansion (25 - 65C.) Fixed Chlorine
Limits
0.27 0.00066 cc/C 54.5 - 55.5%
Methods
HONS 055758
Monsanto
BftOANIC CHlMlCHl OlVIllON
W. G. "tumrorich Plant
FINISHED PRODUCT SPECIFICATION
*,ltfr&VMlN
A. E. Ecisv rrrn-------------------
C. Paton CLNCNM. fttICAIPUOM
t A! ; c J or 1242 , ttlc-cti leal
(ftiTTii'
moovict cooc
vWfHVi~
ALL8S1CO1D,0t 1
rndc " Tv<e~
i8alea, to 010.
9/8/72
1040-241-16-03
NClt A*C H
W, P. Richard 4U`in * COMrnoi (Chi./ Chm.U
H. J. Horner CHEMICAL r &n UULA
mol wt. lOMMIOII >PICI. t>r
(AM*IK FOR ANALVtO
i**vo V
10/22/69 CMANACTlftltTIC
3 x 4 Pt. Amber Bottles LIMIT*
UNRESTRICTED INFORMATION
R.McCutchan/S.Shaulter MB T MOO
(R) Color (AP11A (R) Condition (R) Sp. Gr. ? 25/15.5'C. <R) Acidity (mg. KOH/g) (R) Moisture (H^O) (R) Refractive index $ 25c.
(R) Inorganic (Free) Chlorides (R) Pour Point (R) Dielectric Constant
(60 cycles 6 100'C.)
4 0, Max.
Clear 1.381 - 1.392 0.010, Max.
35 ppm., Max. 1.6240 - 1.6260 0.05 ppm., Max.
-14*0. or lower 4.75 - 4.95
10,084 10,0S 4
10,114 10,087 10,620 10,125
12,741 10,115 T-2273
<R> Hydrolysis Stability Test (As Chlorides)
0.5 ppm., Max.
H672
(R) Monsanto Stability Test (As Chlorides)
0.4 ppm., Max.
11,503
*<R)
Distillation Range (ASTM D-20, Corrected) 10% Distilled by Wt. 90% Distilled by Wg.
Sulfates Dielectric Strength ? 25'c. Flash Point (CF)
Fire Point
325C., Min. 360C., Max.
None 35 KV, Min. 338 - 392 None
10,117
12,169 11,605 10,123 10,123
Corrosion Test (16 hours 8 210ftC. with bright
Aluminum Foil,) Change in wt. of A1 %
0.0
A.C. Color (APHA) A.C, Condition A.C. Acidity (mg. KOll/g.) A.C. Inorganic (Free) Chlorides Vise. @ 100F, (SUS)
60, Max. Clear 0.010, Max. 0.05 ppm., Max. 82 - 92
10,084 10,084 10,087
12,741 10,066
(R) Power Factor @ 100eC., 60 oyclos. Max.
Bulk Drums
(R) Roulint Anotytit, All cthtt$ Anolyttt by rtqucil Only
Internal customer
(TT5T-- TT5
T-2273
2.0
4.0
GENERAL INFORMATION - PAGE 2
*
HONS 055759
Characteristics
GENERAL INFORMATION
Specific Heat 0 25C. Coefficient of Expansion(25~65C.) Fixed Chlorine
SPECIAL CUSTOMER REQUIREMENTS
General Electric
Thermal Chemical Chlorides
Westinghouse
Ilydrolizable Chlorine (Westinghouse Stability Test)
Limits
0,30 0,00068 cc/C. 42.6 - 43,5%
Methods
0.65 ppm., Max. 1.0 ppm., Max.
12,722 T-221?
I MOMS 055760
Monsanto
OH 9 A NIC CHIMICAUl OlVIllON
W. G. Krummrich Plant FINISHED PRODUCT SPECIFICATION
Another.on mAU. E. 1I.eisv
C. Paton
9CNCAAL bOCRlRTION
Inerteen 70-30 Transformer Fluid nbTUzrwt
W. G. K. 6AYi iprievivi
AH8I1n0,98"
SaleB
,.253-
5/17/72
1050-210-16-03
AP.A.V ALA
TOTHTEh........................................... ................
OWU.ALITRY. CORNTiRcOhLa(Crdhllt
...
R. M..BlowersCH_I_M_IC_A_L_F_O_R_M_U_L_A________________
tURIMIDII
OF
7/10/69
Mixture
70* Aroclor 1254 30*Trlchlorobenzene
Plus 0.20* Gylcldyl Phenyl Ether
AM*LK AON AHALVai*
H*U0 OV
3 x 4 Pt. Amber Bottles R.McCutchan/S,Shau1ter
CHAAAC1AAIATIC
UNRESTRICTED INFORMATION
(R) Color (R) Condition (R) Sp. Gr. 0 15.5/15.5 C.
(R) Acidity (mg. KOH/g.) (R) inorganic Chloride (R) Viscosity 0 100F. (R) Dielectric Strength e 25'C. (R) Refractive Index 0 25C.
50 APHA , Max. Clear
1. 518 - 1.528 0. 014 , Max. 0. 05 ppm., Max. 58 - 62 sus 35 KV, Min.
1. 6163 - 1.6193
10,,084
10,,084 10,,114
10 ,087 12,,741 10,,086 11,,605 10,,125
(R) Distillation 1st Drop Below 270C. 90* by Wt.
(R) Pour Point (R) Moisture (!)jO)
(R) Fire Point (R) Glycidyl phenyl Ether
(R) corrosion Test 6 hrs. 0 210"C. with bright A1 foil Change in wt. of A1.
A.c. A.C. A.C. A.C.
Color Condition Acidity (mg, KOH/g.) Inorganic Chloride
(R) Dielectric Constant, 60 cycles, 100C.
200C. , Min. 35*, Max. 379 - 394C.
-30C., Max. 30 ppm., Max. None to boiling point. 0.18 - 0.22*
0.0*
10,117
10,115 10,620 10,123 11,865 10,126
200 APHA, Max. Clear 0.014, Max. 2.0 ppm., Max.
4.3 - 4.6
Internal Customer
10,084 10,084 10,087 12,741
T-2273
(R) Power Factor 0 100C., 60 Cycles, Max.
Bulk Drums
1.5* 2.0*
2.0* 4.0*
T-2273
(Rt Routine Anotyeis,
i'si Only
RONS 055761
Monsanto
W. C*. Krummrich Plant FINISHED PRODUCT SPECIFICATION
Inerteen 54201-CM
PLANT
1f. .. . 259
w. G. K.
rcrm81rs1is.1r-0'--------------- Sales
5/17/72
1050-216-16-02
.
pnoouc T ION
A. E. Leisy Mill
C. Baton eGHCNM. DCtCAIPTlON
nmwr------------------------------------------------------------------- ---e. Wu*iL,tr.Kv cionMr*O.Lch(Cahrd/ti_C_h__m__iti_)______________________________
R, M, Blowers
99.8% Aroclor 1242 0.2% Glycidyl Phenyl Ether
MCI. WT. |7('*P(DR *PIC*> OP
10/21/71
CHAP AC T rPIITIC
(R) Color, APHA.
AML( POP MUIVIII
i**ut6v
3 x 4 Pt. Timber Bottles H. McCutchan/S .Shaulter
LIMIT*
MT >i
60, Max.
10,034
tR) Condition
Clear
1U, M :M
iR) Sp. Gr. 0 25V15.5C.
1.381 - 1.392
10,114
<R) Acidity (Mg KOH/g.)
0.010, Max.
10,087
(R) Moisture, ppm.
35, Max.
10,620
(JU Refractive Index $ 25C.
1.6240 - 1.6260
10,125
(R) Inorganic (Free) Chlorides, ppm.
0.05, Max.
12,741
no pour Point, "C.
-17 or lower
10,115
(10 Distillation Range (ASTM D-20, corrected) )0% Distilled by weight. 0OSv Distilled by weight.
325c., Min. 360C., Max.
12,169
l IO Dielectric Constant, 00 cycles, 100oC.
4.75 - 4.95
T- 2 2 7 3
1 IO Dielectric Strength @ 25 c. 1 10 Fire Point
35 KV, Min. None to Boiling
11,605 10,123
uu Viscosity 0 lOO'T., SUS
82 - 92
10,086
IU) Glycidyl Phenyl Ether, %
0.18 - 0.22
11,865
<K) Corrosion Test - 6 hrs. 8 210C. with Bright A1 Foil
Change in wt. of Al foil, % Color, aPha Condition Acidity (Mg KOH/g.) Inorganic (Free Chlorides , ppm.
0.0 100, Max. Clear 0.010, Max. 0.05, Max.
Internal Customer
10,084 10,084 10,087
12,741
(1<) Power Factor @ 60 cycles, 100C. Bulk
li K.ibf'Nt' Aunlys n, A II
*A nuly * ft! ,
>(, brums
1.5% 2.0%
2.0% 4.0%
T-2273
HONS 055762
M66UCT COM MONSANTO INDUSTRIAL CHEMICALS COMfANY 810.93
161*' 6* ,6* | 259
Wm.G.Kruinmrlch Plant
TENTATIVE FINISHED PRODUCT SPECIFICATIONS mopiici l lteds Namti
1050-302-16-003 IPPUl 6AT( lUMDtmi (<. PA'IO
A/2*/74
HEW
anAtt
Transformer Pvranol A13B3B3 pacovm iC'ltmfroi NJ
Mixture 60X Aroclor 1254
40X TCB
ItMHI *6. A*AlVPI
EP-221
2x4 olnt amber bottles
A*A0VAt - pA tl CHIC* CMIUI,
II. J. Horner MAmVPAt'VAlNf W*I.
A. E . Lelsy MPA., MANI/PAt'lHtlAP
J.R.Savage HJftl """ "
R.H.Munch U*AA6DAVnCt'llMMAOw*ApMtAVtlO'MIMT
C.faton
..........
__ W.R.Ppa,aorta_________
Chinctirlitln
A.lret
LIMITS Mmuftctutlno
Unrestricted Sales
Method Number
(R) Color, APHA (R) Condition (R) Specific Cravlty 25/15.5`C (R) Acidity (mg KOH/gm) (R) Kolature (H0) (R) Rafractlva Index 25*C (R) Dielectric Strength 25*C (R) Vlecoelty 37.8'C (R) Pour Point (R) Active EP-221 (R) inorganic Chlorides (R) Power Factor 60 cycles100*C
'
3.0%, max. (Bulk)
3.02,max. (Drums)
150,max. Clear 1.495-1.510 0.014,max. 30 ppm,tssxa 1.6110-1.6120
35 KV.mln. 44-48 SV8 -38*C or lower
0.115-0.1352 0.10 ppm max. 5%, max.
10,084 10,084 10,114 10*087 io;62o 10,125 11,605 10,066
10,115 13,014 12,741 T-2273
5X, max.
(R) Corrosion Test
10,126
After heating with aluminum for 6 hra. at 210*C, the aluminum muet not be corroded elther.-on vleual or weight lnapectlon and
the Fyranjpjl ehould meet the followlng/ritpeclfleatlone*
Color, APHA Acidity, mg KOH/g Inorg.Chlorides, ppm
Condition
200 max.
0.014 max. 0.15 max. tentative Clear
10,084 10,087 12,741
10,084
(R) Routine Analysis, ell other analysed by request only.
' NOT*. O.J5tl \/74
ef thp
Cmaity *ne it r*r
vm enly. M mty not bp pUppppS without wrKWn pp*fpvpl by
MONS 055763
General Properties Not Included In the Specification Teats
Dielectric Constant, 100C,60 Hi (ASTM D924)
Burn Point (ASTM D92) Fixed Chlorine Coefficient of Thermal Expansion
(ASTMD1903) Distillation Range (ASTM D20)
Corrected for stem and barometric pressure
First Drop 352 552 652 ! 952
6.2-4.6
T-2273
None to boiling point 10,123
55.6 + 0.5
10,088
0.0007 cc./cc./*C
208eC,mln.
2479C,mln. 360"0,min. 365*C,mln. 380*C,oiin.
MONS 055764
Monsanto
ORGANIC CHEMICAL* OIVUICM
Anniston and Krummrich FINISHED PRODUCT SPECIFICATION
proouc t
>*! -Ann
INERTEEN 70-30 TRANSFORMER tbUID
A-2 16 Wf.K
l.ant Aimifcl on
,'MWVt\ COO Ann uT2--------------------------------------------
WCK
8)098 - WCK
SALKS
7/10/69
**<.(.' CODE
1050-210-16-03/09
API'N OVAL* fiF.**A*i'f h" '
J. W. Mollov
XuTS
W, E. Ault
OtHl.AAL Ot*CAII'TlON
J. Vf, Baker
4UAU1V lOMTSOl (Chl( ChttnlH)
R. Blowers
, W,
Chemical roim*
MlllOf
Mixture
70% Aroclor 1254
80% Trichlorobenaene
MOL Wt.
Plus
0,20% Phenoxypropene Oxide
amplk roft analvii*.
i#uto v
4/10/66
3x5 pt, Amber Bottles
Higgerson/Stites
CHARACTERIITIC
LIMIT
METHOD
UNRESTRICTED INFORMATION
(R) Color (R) Condition (R) Sp. Or. @ 15,5/15,5*C,
(R) Acidity (mg, KOH/g.) <R) Inorganic Chloride (R) Viscosity @ 100*F, (R) Resistivity @ 100*C,
ohm/cm
50 APHA, max. Clear 1,518 - 1.528
0.014 max. 0,05 ppm,, max.
58 - 62 SUS 500 x 109 min,
*R) Dielectric Strength @ 25*C, (R) Refractive Index @ 25 *C. (R) Distillation
let Drop
35 KV, min. 1.6153 - 1,6173
200*C,, min.
Below 270*C.
35%, max.
90% by wt.
..379 * 394*0.
(R) Pour Point
-30*C., max.
(R) Moisture (HjO)
30 ppm,, max.
(R) Fire Point
None to boiling pt.
(R) Phenoxypropene Oxide
0.18 - 0.22%
(R) Corrosion Test 6 hrs. @ 210*C. 0.0%
with bright A1 foil Change
in wt, of A1
'
AC Color
200 APHA, max.
AC Condition
Clear
AC Acidity (mg KOH/g,)
0.014, max.
AC Inorganic Chloride
2,0 ppm,, max.
10, 064 10, 064 10, 114 10, 087 12,741 10,066 11,607
11,605 10,125 10,117
10,115 10,620 10, 123 11,665 10, 126
10, 084 10, 084 10, 087 12,741
RESTRICTED INFORMATION
(R) Power Factor @ 60 cycles and 100 *C.
5.0%, max.
11,608
HONS 055765
Monsanto
OftOANIC CHCMlC Ati t>) VIltOH W. 0. Krummrich Plant
FINISHED PRODUCT SPECIFICATION
PRODUCTION A. E. Deisy
mtl
W. E. Ault OtNCRAL t>*CRPT ION
PHOO'M.
----1nerteen 4201-CM
vcitVf
PRODUCT COOK
UIC
W.G.K. STTTrfrrnrnrr
811.10 IALI* C66C
10/21/71 APPAOV AL*
1050-216-16-03
|o* r.
1 2S9
Sales
W. R. Richard OUACITV CONTROL (Chl$t Chtmltl)
P. M, Blowers CHtMlCAL PORMULA
M&L W7.
UPkRICOK* PtC*. OP NEW
CKAR ACT CRITTlC
IR) Color, APHA
99 ,8V. Aroclor 1242 0,2% Phenoxypropene oxide
f OR ANALVIII
IMUCO *V
3 x 5 Pt. Amber Bottles S. M. Shaulter/G. Stites
LIMIT*
METHOD
60 Maximum
10,084
UO Condition
Clear
10,084
(R) Specific Gravity @ 25/35,5C. 1.381-1.392
10,114
IK) Acidity (Mg KOH/g)
0.010 Maximum
10,08?
(R> Moisture, ppm
35 Maximum
10,620
(R) Refractive index 8 25c.
1.6240 - 1.6260
10,125
(R) Inorganic (Free) Chlorides, ppm 0.05 Maximum
12,741
(R) Pour Point, C.
(K) Resistivity, ohm-cm 500 VDC @ 100c. 0.1" Cap
-17 or lower 100 x 109 Minimum
10,115 11,607
IK) Distillation Bang (ASTM D-20,
corrected)
10% Distilled by weight
325C., Minimum
90% Distilled by weight
360C., Maximum
12,169
IK) Dielectric Strength @ 25&C.
35 KV, Minimum
11,605
(Rl Fire Point
None to Boiling
10,123
(K) Viscosity @ 100F., SUS
82 - 92
10,086
iKI Phenoxypropene Oxide, %
0.18 - 0.22
11,865
(HI Corrosion Test-6 hrs, 0 210C.
with Bright A1 Foil
Change In wt. of A1 foil, 1
0.0
Color, APHA Condition
100 Maximum Clear
Acidity (Mg KOH/g)
0.010 Maximum
Inorganic (Free) Chlorides, ppm 0.05 Maximum
10,L26
10,084 10,084 10,087 12,74]
(R> Rfi^iim i4nii/)i*. .// otheit AnofyttJ l-y <e<jur*t O i>
MONS 055766
APPENDIX C PHYSICAL CONSTANTS DATA SHEETS
This section contains physical and chemical data of the raw materials and finished products.
Time 0 3 days 7 days
DEGRADATION OF TCB
inorganic Chlorides
Dark
Sunlight
000004!t
.0000043:
.00000431
, 0005%
.0000043:
.001*
VAPOR PRESSURE OF PYRAN0L 1481 (obsolete) (75* Aroclor 1254, 25* TCB)
Temperature
Partial Pressure TCB
Partial Pressure Aroclor 1254
112 C 50 40 30 20
10 0
13.12 mm 0.76 O. 34 0.23 O.lll 0.057 0.027
0.039 mm 0.00051 0.00022 0.000086 0.000032
0.000011 0.0000036
Total Pressure Pvranol 1481
13.16 mm 0. 76 0.34 0.23 0.114 0.057 0.027
HONS 055767
60209 PHYSiCAL CONSTANTS OAT
c * ") iVnuX:'i'unALT6j;* ____ TR1CHL0R03ENZKN E____ _____ _
(Mixture of 1, 2, 3U, Z. 4T. C.B, 1 CTWPflTtT CY---------------------------------------------------- fbxvr- "
Hooltor Electrochemical Company |7-?.5-D7
*
NAI'.C
______
______ __________
l>!wu!.v>WrJ;']il_____ ___ __________________
taJijtitW________
...
lifilUjv;.CvJi 'jXMm______________________ Mte firti .rt_--m_________ .------------------
BslIteJi'llJ.lL.
----
(tailin'! Point i)____m__________________ ____
... - Clear colorless 280*0
______cS'.'CCJ>.tXiit'i_ -
_Rsu.l...................... . Kef. 1
"'Kef.'' X
----------
Ref. 2
Sia?tsiMo."..C!:i_________ ;_______________ (AjItlnsTfirJ______________________________
10*0, Max.
IksQ"
MmMI-------- .fTvnTrw-- r;m;:r:vrt-
'VefrT
Sjfcllic Gis.ilyji______ ____________________ I'uimds pet 67.1. if I S. 5 gC
CwHldtnl tl CxpiJirlon Gobi cal KC'linclivo l" 9:9.j?296 n 8
____
_i?.,.2_ . OO'OBf"
"I7S75-
Ref, 2 Ref. 1
feM'}.5!:2fi'!/st?'S!CA
______
itosM f___lOOMl____ ________________
ViscosityA...j) 0*_F
Su'LtO'M'-it'n.I@?!>.G _
&llSIlill(Jl!.tW......._____________ siwtunif lA-.y;*?:**.*:-. 2Jl1c___
1.100 Gen'.intoken 0. O'!9 Ccntirtoken
30T"9d yn es / c m ~___
Rcf._2_ 'Ref. 2
IKeOI
, 6025 grams/HOO Rratris 1UTTT
Sp.ijJbUUyJ!)___ ..______________
[IW.ll.PoM t'('(VM.-.OCU'.vt-lElH\ opt! 71 cu None______________ ___
tki'fM-c. Ill'll.'..
Jjone UE lo fcwlinp pt_,
___________ __
------- ----------------------------------
It6J.n!;i.S!''<iiiiylw!/ii5''`'ibl________________ ll,'.MLHtH jl.fjalsa...........................................
UIal.llKi.ci.Va__________________________ ije;.', ,i?5!C_________ ____ _____
5'l 'cf.j/g<ar.i___ '6720'...............
'
Cliil.ctLTf
________
cij.vm.pj. y.s_ _ __ _ _ _ _ _ _ _ _ _ ___ i.._
Cif}.ccj!u'.','.C;n.!l;n|________________________
J\e f, 2 Ref. 2
Ref, 2
Moi n lure c oiilc.'it_____________ Diet! II i'll: 071, n [;c J)econvnonition temperature" Pennit> coirecon (actor___
Isomer distribution_____ ___
, 0I>9, 'Max." "S*C,""Mair. Tncl 216 " I Sfl'6~+"rC'" ' . 65124 pci~~T*C
Mi nature 1, 2, ?frl. 2. 4
lRuejCr3'r
RefT2 Refrr
ReL.
RefeTcncee (TTXan"es Hencibrlok Ktfer cnccc'fa'PC^PMal>tir ,,
References fit Hooker Si>cc.iUf.iUlitSation
Tonicity (Oiw.
do
H0N$ 055768
HONS 055769
PHYSICAL CONSTANTS DATA
*uromwr...... * ....... ..
AKOCi-OK >i<n
`cowurGii --.................... . .......
_ ____ name............ --__________
[oi.muU.............. . . ......... .. ............ j^lu'ulM.Wci^iit. . . . . . . . . . . . . . . . . . . . . . .............
fo&MlA'lCC................... ... ......... ..... ......
BiJlw..r.p!ii5-
________
WIH# I'tiiil.tl. 3.. m...... -___ _______
Builif^ Pwdi.rt... mi............... ... ...... v.... g5i}in Poinl al__ m ___ .._ ....
CQDUIliiiriifpinl..... ......... ....... .........
I.'j;llj.l!f!nl-------- ------ -------
.. .TSASAI ..,,....
.Cia )': v. . ..............
457. ___ _____
.. Qfti.pjj t si.Mti; Lc . Oc....
>2S - !<;0 Q,
_
..IsTrisi C_______ ____
No'-cr.yA' all -,i\' (i
ck^~.y .c:i
,,.........JP.ytltl-.L,8Mt._______
XL.a.sa.-.j.l. Bui\_OP-.1
........,,rir>...........-.............. ....
SpstiJit.Cwily.i'.. .id (a.M._________
. 1.3 SC:........ ......... ........
1 .*..c.>................. l. }8j - I . >Q>
fill's jici Pci. tf . (?bf'C____ __ ______ il/50
_
CocrntjCM! cf E;5.; ('^C._______ _P...OCOlL.tJetAC..
hjgKiKtKjL__.................. ..
llllli I|C(I SptfilL'tl (Rfjrur.tt) ____________
UIPaVi(ilol^fuclniiii//(f/'^nrJj............. .....
......
vi.wtib.*: ...ho. T,.... ............ ......... -A4=.JS..SUS._.......
Jteilly.*.. 19.0-Z,.. ... ----------- ._8A..9<LJiUS.............
Suiik*.1 mien... J?yr,t/* SJS.
...IS.JI_____ __ _____
ip m.... ..___________ __ _ _ . r.>L*..i,y..P. ._______ MlMUttk.JA.&.C.'ufii.. 49.C_____ A. ip. /j or' yy....
^DjlrJi J?j.r,,4i>je...... j|_J.Q ,`;C,._____ i.?.4...5. j.,/J 00_.ci.....
|Aw f t; <*.:..:. -. Jt.i 1 i . 5r).
M..U,..OE.-^r/......._.....
^SpC2.(:x.r,>.t:.a. --2?J A- SS..
M/.ih..oK7~7.I77.
lr
.. ' v _C<o.L. ,
i-i., . J hl:y
OP.-.j^ ...........
rish row `
iii c., <>.. c,..
fS'Pl'.'lT'l'''.
c.,o.t....
UpflPi.Ru.'-wi'a............................
(let! ..... .......... ....
ItertSISilllx
......
U'.iiiiUlP.f! cl..FPam.
uiwi ijpgt
/.am*___
^ficjlccd. vC.............
QlWyl.Ttv............ ........ .... ,,
CiMT: !.r;i............. .......... t|iccUy.M.CLidU......... ..........
..I PO Q. None-
61 .0,1^......
.........o4j*e..._._..........
Pr.-x
....... ...... .............. j Cj r;r .Iftyjj _
j-t'ini* Co* tioc*." )'y, c&l /
..........
<rn7 ?. Zlilo Z'&M1q71L
D o it r: < Cc" sift1 100 C.__
....................................... 60._?Yj.. -... 7 .i7:.^7i..7Z'7
*./vd. ... M..P. OJ'z
YLSLCl&t.rf-./ .>S.S.~--------------.jV/SCMS/rf., ...&/>__-_--_---_--_--_---_--_--_--_--_--_-- ,J ^Cf'M^c.i....^..A...i...t.:.L..(.i.!c...U'itL.
A-.PJl7.4.______ fi'.fiJg
/3fi+.................. 13..
4*6___ . . f .. .OP.-
NO 7 C: 7 hr * r t'olu ihoiJd not Af ttttas &A cutnet of S'.uo.M.nlo ChtnietJ Cv'iipmi) t t ttiuiltf A.r
MOWS 055770
.. .... PHYSICAL CONSTAlMTS DATA
_,,A|iQCLO!i,, J?H__________
^J\x! M 1)j!)j<-.M.:;.ry....i...... r_
' ___ NAME ........... t'otafai iycjtM_____ ____................... ...........................................
hvwrd------------------------------------
flopiiJlinii'jUfie'tierlf'.JMW.aJ'jirio*.._.._..R.a.I'.Ib_*____ MWliiMttJfttaLft___iinm________________ Mfivilki!s.(hi licC!-c_tp_l..._.._._.._.._._.__.._.._.
faccHIc OnHlf B5/i'-. 5 C.
LC'0o'iH--i-fiAci-cP--ni_(Cifri:-.?7'.'.)1<>i\ -<,.c:_-_f_Cc_.___
ii3llilii.W<* p____ ?.'.Pnlh______
jntra cdJp?ctr assfl...... .. . (M'l'.ii'X____
yjmEs.........Act. k____ yjos(ty..<-_________ .___
W/aJirlD._........llYM.s/p.ro. _
WSili.MlltiteyJMa.>. ?:.A___AL_s_?!_:_JM__ --oC--l.
X.;._
I'C/Tl:......--
o. .N-"-v fri,
_______________
___ __ __-XUIJUsCa________________
__ ii.PU.i_oi.l- iMazz.fcfsio>Rrii n
aef>A-AC__ __ _ .jen^-eSi__
Wor-crvV&t.lpl-ig__
1L..4!.93?8_^l_,5_-_0_*.______ _ ___ Rr.rx.v,.t.3=..;Jxira r<.!\A!'. y,n___ ___<,------- U'QLgVUJJl......... ........
_e,.ft(.'08.6..colac.LX__ .__
J<i3.TM_:i..339n ________ S^clJissltai llXi
-3.4-ttLl\Si
MlToA111.
.JniQl.'Uf JAp,i.iPl.cc
114 g. /ten cc
______
\ c. o. c.___
[.'.I.?. Miil'C............ .. .C.JKP. G.'tslif-CcKWsn
___________ Xteiio W,'>i|iw.(c(tAif/rUp-l_____
__ _______
Pl.Yf?,........ sal ton.----
Sifit'itHPlU/l!r.Tirto:"i,.i_it_!______@__Z:__C______
X-,; f._______________________
,iio:_v-__ _________
.1C __
Ct'iv.:v.pt)
jviK.QEi u\,--_
WSMSIili:*.!!i5!M.......... *----------P< !:,:i.r..c Hrv....qJOO...C.______
.5..3.34_________
Cc,lf------ ----------------------- ... I-TfcTfr- - - - - - - - rr.cz.'Zro.msr?p'fi.=_zzii
........ :"r`;c Co-
iOPuC. lehoi
'l o be j'-iKt Jcd_
RuCiCfZ ""7
TmMj; (Cm* /(r/i'liI';-//..
LM-ii.-ca'-t)..'.
HOT!:! Thn.r ririin thcmhl lull be rtlteitd rrlsidr rf llorirr'o Cbtmieol tompeay. Vst aditilionrt iV**la If i.' i 'miy.
MONS 055771
PHYSICAL CONSTANTS DATA
..... i'YKAKO:..... 14e 1 ( {.; I ')............... .........
KIM uD L t 0<1MUI A
Mlxt.ire 75% A roc lor 125-4
ttaoiirnur ... ..A., V' I-'?K'riK.i.i. ;'
............. .......i.^Z.
: ....
!
25 % Trlchlorobenicns
__ _____________ _
FfjinuK... ........................ ...............
iWociiliJMijil
.... . .____ ___ ____ ______________ .
tawraw........ - ...... --___ _______ J..^'.dtoi!ull7Xwi.mrii'il!t o.U. " * IjS>.*5* _*lp.A ..IV :* !_.... ..
#i* MU .&?*...........................-...... W!r< I'qiajI ..m......-------------------------
OiiJiJis.RcJnt.d.....job...... ... ............. ...... . BillL'is.rjL'lri..................... .... _....... .........
...... ..................
lieHu!j.Pwnl.,------ -- ------- ------------- - --------
feMlaiSW,,..._..............................................................--. .`.U5.25-_LI>25____
N'i'nfi'pS
......... -- ..........-................................
,. {PC___ ______________
Cttflitiwl c! Exp.'.itiM (20 iOOC)
...n.L(LO'Lc_c/,ciiyC..
iS'KiTUcfe.1!.__ ?5?!C_.n.J__ ............ Limu^ms___
irlTaKriilpw' iu;;i.flj .'.-1-1...... ......... ......... ....
lljl.r. Violc: Sp'..ct!in)(/l.r/t-.M.(| . ........ .......
YitMiitt.t______ if.O'.T___ ___________ :,,j.a.-.62.ms.__________
____________ _MkmUw............ ................................... .... - -
5.li4>i.liW|tjjCti'__________________________ SoliSilUlvIo_______ ______________ _______
VMJlilrw.... .. ....... ,.............................
Flo.'li Piiil l'FJUot-U Olt Polni.,C______ .C..Q..C____
l.k'i.P.lCt'.,)Kti.l_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
PJePl .(. Frii-i-`ipn.......... ............
fe'.-AlA li,).. . -....... i>!?!! pv'. l'.lf I fa' ............. -.......
UlCrUk-l.... --...............
$i!lkJ.lr.\____ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
('iM.Iw-PjVv____________ ___ C'l'-itrLPr.-.. ----- ----- ------- --- Ut.<sr.4lf.ilfi.(;":..'.'Jfl_____________
Rev rl^i'T __ _ _ _ _ _ _ _ .
..HoQe_.tQ.bomn?..
L -.r.i&:JC..or..lo.wjB.c,,......
__
______ ______________ |~ Cov.Uci MuUcalT>cBt,
NOTE? Thi'te dolu should nt>i lu ttlentrd vuftidt of
Chtrr.ieol Company C'it c.d'h'iturj thttit if
HONS 0557?Z
DEPT. 259 - STANDARD MANUFACTURING PROCESS
PYRANOLS AND 1NERTEENS
APPENDIX D - UTILITIES
The utility calculations are based on 1973 actual usages. 1973 monthly production averaged 1.1M lba.
The breakdown of utility usage by Individual equipment is only an estimate. The estimates are based on the total monthly usage of each utility as taken from the cost report, and the relative period of time that each Is operated.
___ ELECTRICITY - 440v, 3 phase, 60 cycle
ITEM NO.
EQUIPMENT MOTOR
MOTOR HP
PEAR LOAD KW___
MONTHLY USACE KWH
178 179
153 154 160 163 164 165 374
04 Mix Tank (74 Mix Tank Pump TCB Pump #3 Mix Tank 03 Mix Tank Pump TCB Pump 02 Mix Tank 02 Mix Tank Pump TCB Tank Car
Pump
TOTALS
10.0 10.0
3.0 7.5 10.0 7.5 7.5 10.0 5.0
--
70.5
8.8 8.8 2.6 6.6 8.8 6.6 6.6 8.8 4.4
--
62.0
2000 2000
250 3000 2000
250 3000 2000
500
--
15,000
In addition, 110V power is used for lighting and small miscellaneous equipment.
2. NITROGEN (Bulk) -- Because this cost is negligible, all N2 costs are charged to Aroclors.
USING ITEM NO. E0UIPMENT
NORMAL USE SCFH
PEAK USE MONTHLY
SCFH
USAGE. SCF
178 04 Mix Tank 154 Hi Mix Tank 164 02 Mix Tank
TOTALS
4 4 4 12
5 2000 5 2000 5 2000 15 6000
STEAM (80 pslg 9 325'F)
ITEM NO.
USING
NORMAL USE PEAK USE MONTHLY
EQUIPMENT M BTU/HR. M BTU/HR. USACE.
178 154 164
--
4 Mix Tank 03 Mix Tank 12 Mix Tank Drum Heater
& M1 a e .
TOTALS
500 500 500
50 --
1 550
750 750 750 100
-------
2350
200 200 200
40
--
640
HONS 055773
APPENDIX E WORK SCHEDULE
HONS 0 5 5 7 7 4
. ".
APPENDIX F
DEPT. 246 _AKOCJjORS DRUM "STOCK AROCLOR
PRODUCT Capacitor 21x520 12l|-2 EGX600 124 2 With Earth X600 1254 EGXCOO 1254 With Earth X600 54201 CE X600 Dlfenilo dorado (1016) X600 1016 X6C0 " Total Aroclors
GRADS 225 . 241 243 203 203
020
027 016
DATS....... . _
i ! |
-- i
I !
... _ _ L__
*
PVRANOI.S
A13B3B-3 X675 A13B3B-3 X60
302 302
70-30 X674
210
70-30 X60
210
54201 KA X674
217
54201 CM X600
216
54201 CM X55 100-42 X600
216 215
Difenilo Clorado (1242 PPO) X600
214
Inorteon 54201 K0 X550
218
Total Pyranolo
'1
r ii
i
' i'
i
i ! |
1
'
Total Aroclors Pyranols
MONS 055775
DEPARTMENT 239 - STANDARD MANUFACTURING PROCESS IY RANOLS AND INERTEENS APPENDIX G -- MATERIAL BALANCE A detailed material balance on Dept. 259 was not made because loesee In the process are negligible In terns of yield. Minor losses are discussed In Appendix H. TCB yields on Individual batches can be less than standard or over theory. This is due to the fact that blends are made and adjusted to a specific gravity range rather than by percent cooipos i t ion. (See "Yield" section of Comments on Process.) The attapulgus earth and nitrogen is used to upgrade the electri cal properties. They do not become a part of the finished goods.
MONS 055776
DEPARTMENT 259 - STANDARD MANUFACTURING PROCESS PYRANOLS, INERTEBNS
Page 1 9/74 WGK
SECTION 1
SYNOPSIS OF PROCESS
Pyranol and Inerteen are trade names used to designate mixtures of Aroclor and Trlchlorobensene (TCB). A chloride scavenger, glycidyl phenyl ether or unox epoxide 221,1s aloo added.
Pyranols are used as a dielectric in electrical equipment (transformers) and particularly as a transformer cooling medium. The addition of TCB to the Aroclor increases fluidity of the blend at only a slight expense to Its electrical proper ties. Extreme care la uaed in the production of Pyranol blends because the customer specifications are very stringent.
At the present time, three electrical grade blends are made. They eret
Common Name
Other Names
1. Inerteen 54201 CM 2. Inerteen 70/30 3. Pyranol A13B3B-3
Inerteen 100-42, 1242 ??0 Inerteen 54201 HA, 1254 PPO
--
The proportion of components blended to manufacture the various blends are listed below:
Wt. X Product
TCB Aroclor 1242 Aroclor 1254 Unox Epoxide Clycidyl Phenyl
Ether
Inerteen 54201 CM
---
100 ---
---
0.20
Inerteen 70/30
30
--
70
-0.20
Pyranol A13B3B-3
40
--
60 0.125
--
Primary chemical reactions are absent in the production of these blends. The manufacturing steps are blending, earth treatment and filtration, and packaging.
Blending la a simple mixing operation. Small adjustments are necessAry until proper specific gravity and refractive Index are obtained. To improve electrical properties, a small amount of attapulgus earth may be added to the blend and subsequently filtered out. The electrical grade products are sold in tank cars, tank trailers, or in drums of 55 gallon and 5 gallon.
HONS 055777
DEPARTMENT 239 - STANDARD MANUFACTURING PROCESS
PYRANOLS AND INERTBENS
APPENDIX H -- PRODUCT LOSSES
Estimated product losses In terms o f source are shown below:
Typical 12,000 Gal . % of Total 0/Yr. Based on
Batch (Gal.)
Produced
15M P Pvranols
1. Samples & Rinses
4,0
0.0332
5,000 lbs.
2. Filter Waste
0.5
0.004
600
3. Pump Leakage
0.25
0,002
300
4 . Spl11s
0.25
0.002
300
5. Fumes
0.25
0.002
300
TOTALS
5.25 gala.
0.0432
6, 500 lbs.
Discharge to Atmosphere
Based on the above estimate. Pyranol production losses to the atmosphere amount to about 300 lbs. of material per year
(source #5). This loss Is predominantly TCB, whose vapor pressure Is many, many times greater than the Aroclors It Is blended with. The estimate Is based on a minimal amount of mix tank vent sampling data.
Discharge to Sewers
Materials from sources
and 03 are currently collected In
drums for Incineration. Product from source P2 Is placed In drums and goes to an approved landfill. Spills are collected on
curbed concrete pad and directed to the northern departmental
settling basin. Here the heavier Pyranols are contained, pre
venting any Aroclors from reaching the sewers.
a
MONS 055776
DEPARTMENT 259 - STANDARD MANUFACTURING PROCESS PYRANOI.S AND INERTEENS APPENDIX I -- PROCESS CONTROL Three forme are Included In this section: 1. A table of process control variables. 2. A Pyranol batch sheet. 3. A daily transfer sheet (for all transfers made by Second
Operator.)
KEY VARIABLES 1, TCB Quality -- The certificate of analysis should be noted
before the material is used. If poor quality chlorobenzenes are used, poor blends result. In some cases the low quality blend can be upgraded, but in others It cannot. 2, Mix Tank Temperature -- In most cases the temperature should be 90-100*C. At lower temperatures high moisture content Is possible. At high temperatures (130C. and above) loss of the chlorobenzene may be great enough to throw the specific gravity or refractive index out of specification. 3, Use of Batch Sheets -- In a batch blending operation the only operating data available Is that which the operator records. Therefore, these records must be maintained properly. If the batch is in specification on the first analysis, the transfer data will be little used. When problems occur the raw data is indispensible.
MOWS 055779
f Uv*crip;ion of } r^riaor^r As It
5 70/30, A13C3B-3, and 5*201 Ol
Variable I Affects Safety.
or [Quality. Yield,
Pnr-t~ctcr [ P.itc. or Other <*)
Range for Best (Supervision
Known Process j Frequency of Perforcance ! Mon Storing
feasurexnt of Variable Frequency
Aroclor
1242 and
1254
analysis
Quality
[In specification At least gravity is checked be fore each a
Each finished lot of Aroclor
(See finish* specificktl
sheets).!
Interaction How
Vith Other Control
Yartables
Yaclablcs
Concents
Directly
task* adjust*
affects all jnencs vben
finished good?^accessary
analyses.
The reliability of Aroclor quality is very high. Therefore a specific gravity and refractive index check is the only required analysis prior to its use in a Pyranol (Znerteen) blend.
In specification S.C. 6 Index are checked on each shipaent.
Each
shipment
10114 10125
0.001 Directly
[Accept or
0.0002 affects all reject
finished good: shipaeat.
TCB Is supplied by Hooker. A certificate of analysis Is received with each shipment.
2. Y3v | (a) Mitcrial; Contents of Addition} tank before
| charging
(b>
Proportions of Major Conpocents
For different [products. the nix tank should ibe ewpty before charging identi cal p.v>dwets [can be built
a heel.
The ratios should he near those specified in the Standard Manufacturing Process - but not necessarily exactly.
Level indicator}
Each batch] Level gauges or aeter
Each Pyraool [Drus out six
has different tank before
chemical and baking new
physical
[batch.
properties
Momally a new atx is not aade on an existing keel. This is done only when drawing a tank empty would unduly delay the production of another Identical six (or other similar circum stances.)
BThe nost crit ual valve^ In relationship to the old
ical analyses
used In specifications (priot to 4/1/70)
are specific
rglng a
for loerteen PPO & A1383E, the
gravity and iix tank.
specific gravity had to be near
refraeriTe
Specific gra-j the lower Halt for these two
index. When rlties caa be products. 6 the refractive index
these are
averaged. Re-| near the upper limit. This
correct,
tractive indi-east specs, were difficult to
usually all ces caa be
achieve and TCB standard yields
other physicailJ averaged but were often not met.
analyses are wltb less
correct.
accuracy i
reliability.
HONS 055780
%
Process
Area >r Step
JO 2 (Con prder of
tinued)^k' ddltiOO
Description of Parasecer As It
Affects Safety. Quality, Yield, Race, <?r Other
Range for Best Perforaance
PTRAXOLS 70/30. A13B3B-3, nod 5*201 CM
Supervision Frequency of Monitorin*
Measureaem of Variable Freouencv Method
Rate
Add TCB first, then Aroclor.
Each batch
iach batch ty instruc :loo.
<d) reapentOTC
of raw
aaterials
Rate
<*>
[Agitation & (Circulation [during RM
[addition
Rate
100*C. in raw Once/aooth aterlal storage tanks.
Continuous n
2*C.
There should be agitation 4 circulation during raw aaterial addi tion.
Spot check only
Bach batch *7 physi cal check.
Interaction I'cw
Variables
Variables
Cor.-.vsts
A constant By instruc
gravity blend tion.
analysis will
be achieved
ore quickly
if the lighte
less viscous is added firs _
,
After gravity and index has been achieved, the soall percentage additives are added.
Affects pvepin ; Stuaa
tine and
pressure re
initial temp ducer
erature of
aix.
Will affect By operator
the total
training
batch cycle
tine.
3. Hlxlc; (a>
2, >3 Teaperature 4_#4_
Klx Tank:
Rate
90-lWC.
Once/week
(b) IAgitation
Race - Quality
Agitator on, as Daily well as circu lating pmp.
ncContinuous
Each batch risual fcbeefc
2*C.
At lower te^- TIC set poini eratures. the at 95*C. lx tine wil) be longer.
Without agi By instruc
tation,
tion
thorough
ixing ij not
accooplisHed.
HONS 0 5 5 7 8 1
FTRASOLS 70/30. A13B3B-3. and 54201 Q1
Process Area ?r Step
3. (Con tinued)
<c>
Mixing Tla
Affects Safety, Quality, field. Rate, or Other
Range for Best Known Process Performsnee
Rate - Quality J4 hours after components are
Supervision Frequency of Monitoring
Measurement of Variable Frcovencr Method Accuracy
With Other Variables
Conerol Variables
Cocrents
Tine of RM charging ( tine of tanple taking is noted oo log sheet
Large batches Sasples for
nay trice
gravity and
longer before index are
co^lete
taken every
nixing is
4 hrs. until
accomplished. the results
are constant
A. Finis!
Goods Ad The follcprlag aaalyises are! tbe ones note Likely to be outt) of specif! cations:
justments
(when
<>
,
necessary Specific j Quality
Gravity and
Refractive
Specification
Each batch 10114 10125
Index
(b) Electrical buality prorertlee (Power Fac tor Resist!-} elty)
Specification {Each hatch
Each beech 11608 11607
<c) X Chloride Scavenger (Clyeidal l>*K-nyl ethei}
unor
Specification
Each batch 11.665 13,014
+ 0.001 + 0.0002
Gravity and index in-
crease or . decrease together.
For low gra> ty and index, add Aroclor. For high gravity or index add TCB. In most cir-
cunstaaces a d more of a normal component
only. If co ditions are such that the ddition of a di ferent Aroclor would be beneficial, these ay be added in small amounts with supervi ory permission.
Unknown
Related to
If in tbe ai tank a blvnj has a power
free chloride factor hig or than 1.52 (spec js 5.0i aax.)
the batch s earth treaced. One or more
buckets of attapulgus earth arc added
annually. he batch agitated for 2 hours
and then c rcvlatcd through a filter.
After 1 bo r the six is analyzed and fil-
trot Ion co' tiftued. The procedure is
repented i necessary.
0.0022
There Is some If not en^uR' scavenger is present, add mure. evidence that If ton Batch * present. earth treatment r_v
earth treat- Imtec tfw
i-a. at
A second i J tern.it ive
nwy revove
is f> b .iJd u lariivr batch -isin, K-S
sow chlorf Jv
s. .ie.-n, .-s . -
HONS 0 5 5 7 8 3
Process Area or See?
Variable
Parameter
4. {Con 1(d) tinued) |k2o
Description of Paraaeter As It Affects Safety, Quality, TIeld, Rate, or Other
Quality
PTRASOLS 70/30, A13B3B-3. and 54201..CT
Range tor Jest Known Process Perforoance
Supervision frequency of Monitoring
Measurement of Variable Freowencv Method Accuracy
Interaction With Other Variables
How Control Variables..
Specification ICadi batch [Each batch 10.620
+ 2.5 ppd Too each water nay
If water con lent is high, sparge with air or oitroj
lover elect
rical proper
ties.
K,lAI.A i. eLEN! IN A MIX TANK
Blend___________ _______ __ ___ l-c-t No._____ I>ate_______________________________ ___
Keep al ' drip pan', m lor pump sea];, anti packing p,>ands emptied Keep all drums ) ider st-lrers at a level that prevents spill ape Put. nothing out- proat:'. t in vaste and sample drums for Inciner
Mat oriul
From
Measurement
Tar.k
Before After
Number ?r inr>f or Transfer
Mix Tk. Measurement Before After Transfer Transfer
Operator
--
Original blend control sample time:
ResuIts Sp.Cr. .Ref.Ind.yiE
Material
From
rm.ient
Tank Bel ore After
Number Transfer Transfer
Mix lank
Results
Bel ore After
Transfer Transfer Sp.Cr. Ref.Ind. Vise
--
Rina) Samples taken by COMMENT!!.
time
results:
HONS 0 55T6<t
DEPT. 2U6
SECOND OPERATOR DAILY TRANSFER SHEET
BATE
PRODUCT
LOT FROM NIKBER TASK
MEASURE MEASURE OPERATE TO MEASURE MEASURE OPERATOR
B.P.
A. P.
'[ASK B.P.
A.P.
COMMENTS
HONS 055785
I
Dim. W6/D59
TltpHwrl TtmrJmi Urnlttl 'Ul.miliu
ftUM X0UH1
B1THUIL---------1
TBW5------------omlorxdi wa-----------------
rWRWAI/
rlir.tl.rl.llt.
fioiorj
lynptafti
first all
kia^llR) iulrutliM
OMEWSH-YELLOW
SKIN IRRITANT
0A$ VITO PUN0INT, R1 IRRITANT
IRRITATING ODOR.
RESPIRATORY CON*
IH EITHER LIQUID 0 i OtSTION.
QASE0V5 STATE, IT SEVERE EXPOSURE .
IS NON-PLAHHABJ WILL CAUSE DEATH.
AND NON-EXPLOSIVE. CONCENTRATIONS
OP 1000 PPM FOR
1/? HOUR TO I
HOUR CAN Si FATAL.
Rvrrou------- when emwiw monim
CAUSES COUOHINO, QUICKLY PROM AREA. APPLY
TANK CARS USE OAS MASK
DISCOMFORT IN THE SREATHINO AIR OR AJ IPICIAL
CHEST. HOARSE
RESPIRATION IF NOT flEATHIHO
AND OLOVES.
COUOH, NAUSEA,
OR HAVIKO DIFFICULT ' IN
AND VOMITINO.
BREATHINO. KEIF WA IN AND
P. EYE CONTACT - LYING DOWN IP FOSS! tt,t.
CAUSES SMARTING OIVI NAN 1-P OLASSI l OF
Att> IRRITATION.
MUM TO SETTLE STCH iCH.
3. SKIN CONTACT - BRONCHIAL DILATOR ( :lu
CAUSES LOCAL IRRI WILL ASS18T BREATH] to.
TATION AND/OR MINOR BURNS.
?. EYE CONTACT WITH WATER (LIDS
RI 01
SJ
FOR
15 M1NUTE8. 3. SKIN CONTACT ! irsK
WATER. mb
mu'i'ii Pi^ilU OH SOLID OPP-WHITB
8%tf.SS2?
MATSS-WUn 10 STRAW-COLORED LIQUID VKEN ABOVE 69*0.| KEDICINAL SWOT ODOR.
RESPIRATORY IRRI CAUSES SMART1N0 A
TANT. ESPECIALLY IRRITATION.
VAPORS FROM
P. INHALATION -
MOLTEN FORK.
CAUSES COUOHINO,
NORMAL LEVEL IN
CHOKtNO.
WOMUNO AREA SHOUI > >. SXXN CONTACT -
NOT BE ABOVE I M. ! CAUSES IRRITATION ip AIR (ABOUT O.P AND/OR BURNS. PPM). CAN ABSORB
THROUGH SKIN. WILL CAUSE TKERNAX
RINSE WITH WATER
euavrah..
2. REMOVE PERSON FRON AREA OF VAPOPU USUALLY THIS IS AD! QUATE. OZVE ADDI TIONAL BM8ATKIM0 AIR IF NEEDED, 3. SKIN - FLUSH WITH WATER.
DEFT. 2*6. WEAR OLOVIS AND
BASH, VIKE ORANULAR SOLID
VnTlAUUUiH!-----POWD0. OENVUTES HEAT IN OOWTAOT HltV MATER (SMKXM).
USR^VRWf, WOVN, POROUS. ZNERT ORANUUR
BURN WHIM MOLTEN. AND RESPIRATORY IRRXTANTfVERY LOt PROBABILITY OF BftCOMUG A HAZARD. CHW2TCXI BuRHB} EYX DAMAOll INHALATION IMU TANT.
HI IRRITANT 1 (FHYSIOAL. NOT frODCOALl
COUOHINO
WATER, OET OUT OF DUST.
CHWICAL BURNS TO SPBD IK MH9V1W
SKIN EITHER IN
FROM BODY IS MOST
SOLID FORM OR
IMPORTANT. FLUSH
SOLUTION.
WITH LAME QUANTIT IS
EYE DAMAOI - DUST OF WATER, REMOVE
OR SOLUTION CAN CLOTHING INCLUDING
CAUSE IRRITATION SHOES IF NECESSARY
OF'TKE EYES.
IF EYES AM AFFECT h
INHAUTION IRRI FLUSH WITH WATER F \
TATES THE NU00U8 13 MINUTES. IF LAR 1
KEW9RANES.
QUANTITIES AM
INHALED, ORIMC LARI I
QUANTITIES OF WATE
CALL DOCTOR IF IRK
TATION PERSISTS OR
ms AM AFFECTED. n nwiTA-fitw w TOWrmrww
FROM DUST
WATER.
BECAUSE IT ABSORBS WATER AND RELEASES HEAT. VET FERRIC CHLORIDE WILL NOT CATALYSE biphehtl cKLomwATiai. WEAR RUBBER OLOVES AM OOMUS.
wiaH HI MJi'llffKH
wmwuwi-- ARM XOTNUT... ' oas (B*)
POWDER.
[physical. NOT toiSALT :
FROM DUST.
WATER.
IS AN ixwr OAS. ERIATtOMO ONLY
NITROGEN WILL
CAUSE ASPRTOATIOH
HEADACHES, LOSS OF CONSCIOUSNESS,
FINALLY DEATH.
AIR. ADMINISTER OXYGEN OR BREATHIN'
AIR IF NECESSARY.
XW1B MUnUMTMI, PRUViH OOOD VENTILATION.
niuuinu"SSf
LIQUID, STROMO ORGANIC CN0OOAL ODOR.
INHALATION IRRI TANT,
CAUSES LOSS OF HAIR ON EXPIRI-
NENTAL ANIMALS. BURMXMO SENSATION
WHEN FUMES ARE
SOAP AND WATER] CHANOI CLOTHES IF
CONTAMINATED. OET OUT OF VAPORS.
mm*** LIQVXDi STRONO
TwoS)
OROANIC CHEMICAL
ODOR.
UWVlVlL phenyl itnn
VlSoOUl LIQUID
IKHUI
INHALATION IRRI TANT.
SKIN IRRITANT! CAN CAUSE 8IVIRB RASH.
9UH 1IUUTAITTI CAN CAUSE SEVERE RASH.
CAUSES LOSS OF HAIR ON IXPERIKDTTAL ANIMALS, BURHINO SENSATION WHIN FUMB8 ARE BREATHED.
OF CONTACTED AREA IF NOT REMOVED FROM SKIN.
SOAP AND WATBR] CHANGE CLOTHES IF CONTAMINATED. OET OUT OF VAPORS.
WAbH Thoroughly WITH SOAP AND WATER, REMOVE CONTAKIMATED CLOTHING. IF SYMPTOMS AM ALREADY PRESENT, REPORT TO DISPBUA! r.
OP CONTACTED ARIA
IP MW REMOVED FROM 8KIN,
WITH SOAP AND WATER, ABOVE
CONTAMINATED CLOTKZNO. IP SYMPTOMS AM
ALREADY PRESENT, REPORT TO DI8PBN6AP r.
viaN HI/BUK uuivks, III PWJl'WflUi
HONS 055786
ThpiftiMAl 'Hiurinui Ghtnlrsl lufimallM
paoe ?.
uni
IWMKIMAtH CARROUDCELORS
tktnrlirtillcl
. W. PRODUCTS! ' PURPLISH TO SUCK OPEILTYROLLIEQUUMID-L,IKB OHO0,DAO0NOW>DRWTL,AEIUVHDSHSHUDLOAISELT8SL; 0Y5LVTRHDAI
Iimri TINAHNATLA(HTOIOTNVAIRPRORIS). THERMAL BURNS.
'
tynpUmt
firit it!
CTIONUOOHTIONOB, RIERARTHITEA. ORETHDENRESTSHEARSMPAOLR Am
GET OUT OP VAPORS. WREAMSHOVAERAIAROTCOLOR AND TREAT AS ANY OTHER
BURN. BURN.
HCYHDLROOROIDEHE ,(KOL), 0KN0IOOLNNO-LRPYUUMSOMSOAROBRLAOESS.iIVEi READILY DISSOLVES AINN WACATIDER. TO PORN
TIARRNRADICTRTAE.NSTPCIRTHAOETMOEIRYCYEASL BURNS TO SKIN. TWAEHNXITEDPHLAROMCESLAIIDVENAEYSCEMKOSYMEDTBRAINLOESOSC 0A8.
TEIRHYRREOISTA.ATTS. IKOINN TAOND
NCTPWWOOLIAINUTNTHSDUETHRAITSWCIPSEPTAEOYE.TNREDESSRPAA1. RL5RWUERYISATE.HHPORT
\nrfmaaQM
sm AROOLOR l*?t
mim \im mINIi
J. LBHIIAQPTHUEEIRDN-WYSL!HSICTAKENLDO0AILSIKYOAM1 UNREAOTED SIPHDCfl TPHUASNHTHPOOSINETPRLOOWDUECRT wTnLHInQWAUTaID-AxWRSrE)ufCCloHxH1Lho0OmRlRwI,NI.N.A.A1 TvwCExHitDsLhOonoRorIsNanxAnouTnIsOsrNnuOo. iPreasi
EDTINHHETARANMLATATL(IOHBONUTRNIRVSA.UPOR! !B>
TTHAENRTM(ANLOBTUVRANPSO. RS) 1
J.TACRNEDOYDWWNKOEXTSTMOSHOEBAR, SRTIEWHPAEOTURRHTMEA.ALBURN. TINO TO aREAlHE. ARBNUEYDRNNOE. TSHSERASTHPEORRMAL
TWORREAREMSHAOOTVAEURATAESRAOOAPTNCOVYLOAORPOTHARNESRD. BURN. NASH AREA TO TRBREUMERAONTV. EAASRAONCYLOORTAHNEDR
RiimMovIrmui F.K,-t (CS" <>
WLIQTUHID-V) HBILMINDOSILO! P ACRKOLOCLROORISBNAZNIMDBS
FIMffJL rmiS'
Woi*o5
LIQUID) BLENDS OP
arocloKs, chloro
ObeTnHzEeRneQs.bYaCnIDdYL UPNHOEXNYELPEOTXHIDERE. OR
t
LIQUID) BLIND OP aOErTLHoYEcCRlIDo, RYLakPdHENYL
TTHAEHRTMAHLOBTUVRANPSO. RS) SOMEWHAT N0R1 AOIPRRHRROLOUCITILIBAOOTfRBfISE.NNOBZEETCNHAEAUSNSAER1 TANT (HOT VAPORS) TWSIBCTRHOEAH1REOM5LRIAPEOTOWMURRARSAHITMDEALIMETNMWBGMBVUEOOMT(ARAHSVEBAE.ONNVOEM] TTiMHAEJfRErM(AnltLOWTBUVRiAN'iPSrO.aRSr)r SOMEWHAT MORE ATISRRHCROEAICVTCLWAOHTROLISONBRIOBIEDISCTEHAUANSE
TRIENDONETSOS UBREPAOTRHE. aBnUyRNo. nra thermal
WASH AREA TO TRREMEAOTVEAASRAONCYLOORTAHNEDR BURN.
1
TRIENDONETSOS BARSEPAOTRHE.
WAIN AREA TO REMOVE AROCLOR AND
ABUNRYNO. THER THERMAL TBRURENA,T AS ANY OTHER
TRWABINUENUDYRONNtBO.ETTSffOHSWEBAR,1SRTIERHPAMEOTRRHTMEAA."L TBWRBREUAITMERSHAONBTV. AEWARASEORAOAFTNCOVLTOAPROOTHRANESRD.
usimn----------
VHIASNODOLUEDS UATWTXWDi IM WAmPRSEOIBRLAIDUTPUARTTEOASK. BOXrBCM.I
VREXSrPoIURATJOURUYAIMIXTANT) THERMAL BURN HAZARD. `
TCAOTUIQOKNIN! ST,HEIRRMRAIL BURN.
TsReEtAoTuAtSWANVY nOrTOHnEiRi BURN.
konilin) (MlrutlloAt WEAR RUBBER 0LOVES, EYE PROTBCTIC ACAAROVIRENOATIDP.AACXBTRWWEAHITETHNHINSINGKINHC.OOIITAUVASMPEIHOSBACSWODOTRT WEAR RUBBER OLOVES, EYE PROTBCTU
wkAh OLDVIS, ii rnvrmV*' VMAAOPHLOATENRNDS.tLEUWSEITHOLEOXVTERSE.MEEYECAPRREOWTSHOTl
MONS 055787
DEPARTMENT 259 - STANDARD MANUFACTURING PROCESS
PYRANOLS AND 1NERTEENS
APPENDIX J
SAFETY AND TOXICITY DATA
(Sections 1 & 11 of Appendix J refer to all of Dept. 246/259, only part of which te used to produce Pyranols/Inerteens.)
I. SAFETY EQUIPMENT
A. Fire Extinguishers
1. 2. 3. . 4.
Carbon dioxide - 1st floor, NE of lean-to Dry chemical - 1st floor, SE of lean-to Dry chemical - 2nd floor, west wall Dry chemical - 2nd floor, west wall
B. Gas Masks
1. 1st floor, on sprinkler house 2. let floor, outside west wall of repair room 3. 2nd floor, on west wall 4. Control room, east we-1 5. 4 th floor, on handrail by #1 chlorinator 6. 4th plat form, Aroclor column (2)
C. Scott Air Pak
1. Outside west wall of lean-to
D. Emergency Clothing
1. Box on 2nd floor, west wall
E. Safety Showers with Eye Mash
1. Batch department, 1st floor 2. Batch department, 2nd floor 3. Batch department, 4th floor 4. Continuous department, 1st floor 5. Continuous department, 2nd floor 6. Continuous department, 3rd floor 7. West side of tank farm (alarm in control room) 8. Control room (eye bath only).
MOMS 055768
DEPARTMENT 259 - STANDARD MANUFACTURING PROCESS
PYRANOLS AND 1NERTEENS
APPENDIX J
SAFETY AND TOXICITY DATA
II. SAFETY PRECAUTIONS AND DATA
A. Personal Safety Equipment:
Mandatory
Recommended
1. Hard hat 2. Safety glasses 3. Safety shoes
1. Rubber or canvas gloves 2. Goggles 3. Rubber overshoes
B. Fixe
None of the raw materials or finished products are fire hazards. Fire extinguishers are available in many areas throughout the department.
C. Toxicity (see next section).
D. Miscellaneous
There are many accidents that can occur which may be classified as health and safety hazards. These acci dents can result from steam leaks, product leaks, and other minor hazards normally present to some degree In a chemical plant.
E. Safety Record (Depts. 246/259)
1. Lost Time Accidents - last occurred on January 28, 1948.
2. Serious Injuries - the last two serious Injuries were
a. April 12, 1973 - Broken finger from dropped T/C lid.
b. February 15, 1972 - Finger laceration while working on T/C.
3. Minor Injuries - for the year 1973, there were two minor injuries, for an indices of 0.10 minor lnjurles/man/year In Departments 246/259.
MONS 055789
DEPARTMENT 259 - STANDARD MANUFACTURING PROCESS PYRANOLS AND 1NERTEENS
APPENDIX J
SAFETY AND TOXICITY DATA
III, TOXICITY
AROCLORS 1. Recommended Threshold Limit Value (T.V.L.)
a. Aroclor 1242 - 1.0 mg per cubic meter of air. (0.50 action level)
b. Aroclor 1254 - 0.5 mg per cubic meter of air. (0.25 action level)
2. Hazards and Control
a. Inhalation: Absorption is chiefly by inhalation. Coneentratlone in the workroom atmosphere should be maintained below the recommended levels. Where the chlorinated diphenyls are used at room tempera tures, the hazard of inhalation is considered slight or absent. When these materials are subjected to elevated temperatures, the process either should be completely enclosed or other adequate mechanical exhaust ventilation must be provided to reduce con centrations to safe levels.
b. Skin contact: Operations and handling procedures should be such as to avoid the possibility of pro longed or repeated skin contact. Contaminated clothing must be laundered before reuse.
c. Eye contact: Goggles or face shield should be used where there Is a possibility of liquid splashes.
3. Emergency Treatment: Skin surfaces exposed to chlorodiphenyls should be thoroughly washed with soap and water at once. If clothing has been contaminated, it should be removed promptly.
If exposure to a high vapor concentration occurs, as in the case of spills at elevated temperatures, the patient should be moved from exposure and kept at rest until seen by a physician. Oxygen should be administered if breathing is difficult.
Eyes contaminated with chlorodiphenyl should be Irrigated with water for at least 15 minutes and the patient should be seen by a physician.
HONS 055790
DEPT. 259 - STANDARD MANUFACTURING PROCESS PYRANOLS AND 1NF.RTF.FNS APPENDIX J (Cont'd) 111. TOXICITY (Contf d)
Special procedures: Persons who are regularly or repeatedly exposed to chlorodlphenyls should be examined periodically to detect early evidence of skin irritation and/or liver damage. Persons with known liver disease should not be exposed to repeated contact with the chlorodlphenyls.*
* The information in this section is from the Hygienic Guide Series published by the American Industrial Hygiene Association. The particular pamphlet is "Chlorodlphenyls", Jan.-Feb., 1965.
HONS 055791
DEPT. 259 - STANDARD MANUFACTURING PROCESS
PYRANOLS AND INERTEENS
APPENDIX J - SAFETY AND TOXICITY DATA (Cont'd)
III. TOXICITY (Continued)
The following toxic rating code will be used in describing the toxicity of these materials:
0 - none 1 - slight 2 - modera te 3 - high U - unknown
A. Biphenyl (Code 82601)
Threshold Limit Value (TLV for 8 hours) * 0.2 ppm or 1.0 Mg/M . Action Level * 0.1 ppm or 0.5 Mg/M .
1. Synonyms: Diphenyl
2. Description: White flakes or solid off-white mass somewhat pleasant odor.
3. Constants: Mol. Wt. 154.2; M.P. 69*C; B.P. 2550C; Density: .9910 75/4C.
4. Flash Point: 235F (C.C.)
5. Auto Ignition Temperature:1004F.
6. Toxic Hazard Rating: Acute Local: U Acute Systematic: Ingestion 3, Inhalation 3 Chronic Local: 0
7. Fire Hazard: Definitely when exposed to heat or flame; can react with oxidizing materials.
8. Fire Fighting: CO2 or dry chemical.
9. Formula: C6H5C5H5
10. Biphenyl vapors are irritating to the upper respiratory tract. Workers should not be exposed to vapor levels throughout their shift in excess of the threshold limit value of 1 milligram per cubic meter of air (or about 0.2 ppm). The compound, or organic solu tions of the compound can absorb through the intact skin; therefore, repeated skin contact should be avoided.
11. See Hygienic Guide Series on "Diphenyl".
M0NS 055792
DEPARTMENT 259 - STANDARD MANUFACTURING PROCESS
PYRANOLS AND INERTEENS
APPENDIX J SAFETY AND TOXICITY DATA (Cont'd)
111. TOXICITY (Cont'd)
B. Chlorine (Code 81059).
1. Description: Greenish yellow gas
2. Formula: CI2
3. Constants: Mol. Wt. 70.914; M.P. - 101*C; B.P. 34.5" Dens 1ty 1.47 0 0 * C.
4. Toxic Hazard Rating: Acute Local: Irritant 3; Inhalation 3; Acute Systemic: 0 Chronic Local: U Chronic Systemic: U T.L.V. - 1 ppm in air per 8 hour day. 0.5 ppm action level.
5. Toxicology: Chlorine Is extremely Irritating to the mucous membranes of the eyes and respiratory tract. It combines with moisture to liberate nascent oxygen and from hydrochloric acid.
Both these substances, if present in quantity, cause Inflammation of the tissues with which they come in contact. If the lung tissues are attacked, pulmonary edema may result. A concentration of 3.5 ppm produces a detectable odor; 15 PPM causes immediate Irritation of the throat. Concentrations of 50 ppm are dangerous for even short exposures. 1000 ppm may be fatal even when the exposure is brief.
Because of its intensely irritating properties, severe Industrial exposure seldom occurs as the workman is forced to leave the area before he can be seriously affected. In rases where this is impossible, the initial Irritation of the eyes and mucous membranes of the nose and throat is followed by cough, a feeling of suffocation and later pain and a feeling of constriction in the chest. If exposure ha6 been severe, pulmonary edema may follow with rales being heard over the chest.
6. Fire Hazard: Moderate -- can react to cause fire or explosion upon contact with turpentine, ether, ammonia gas, illuminating gas, hydrocarbons, hydrogen and powdered metals.
HONS 055793
DEPARTMENT 259
STANDARD MANUFACTURING PROCESS
PYRANOLS AND 1NERTEENS
APPENDIX J -- SAFETY AND TOXICITY DATA
III, TOXICITY (Cont'd)
B. 7, Explosion Hazard: Present by reaction with reducing agents.
8. Disaster Control? Dangerous; emits highly toxic tunes; will react with water to form toxic and corrosive fumes of HC1; is heavier than air - gas will hug the ground. People without adequate protection should go across wind until out of the affected area.
C. HC1 Off-Gas (Code 828.51)
1. Synonyms: Muriatic Acid, Chlorophydric Acid,
Hydrogen Chloride
-
2. Description: Colorless gas.
3. Formula: HC1
4. Toxic Hazard Rating: Acute Local: Irritant 3, Ingestion 3, Inhalation 3 Acute Systemic: U Chronic Local: Irritant 2 Chronic Systemic: II
5. TLV: 5 ppm in air foT 8 hour day. Action Level * 2.5 ppm
6. Toxicology: Hydrogen chloride is an Irritant to the mucous membranes of the eyes and respiratory tract. Concentration of 35 ppm causes Irritation of the throat after short exposure. Concentrations of 50 to 100 ppm are tolerable for one hour. More serious exposures result In pulmonary edema and often laryngeal spasm. Concentrations of 1000 to 2000 ppm are dangerous even for brief exposures. Mists of HC1 are considered less harmful than the anhydrous form since the droplets have no dehydrating effect.
7. See Hygienic Guide Series on "Hydrogen Chloride."
HONS 055794
DEPARTMENT 259 - STANDARD MANUFACTURING PROCESS
PYRANOLS AND INERTEENS
APPENDIX J - SAFETY AND TOXICITY DATA
111. TOXICITY (Cont'd)
D. Ferric Chloride (Code 33500)
T. L.V. of 1.0 Mg/M3 Action Level 0.5
,
1 . Deacription: Granular solid
2 . Formula: FeCl^ (Anhydrous)
3. Constants: Mol. Wt. - 166.22, Melting Pt sublimes solubility in H2O very soluble with heat rise.
4. Toxic Hazard Rating:
Acute Local: Irritant 1: Acute Systemic: U Chronic Local: Irritant 1
Chronic Systemic: U
Ingestion
1
5. Fire Hazard: There is no fire hazard under normal conditions, but it will emit toxic fumes at high temperatures.
6. Handling: Protect the skin with approved protective clothing, avoid the breathing of FeCl3 dust, wear
approved respirator with adequate cartridge, and protect the eyes with approved goggles. There are no storage regulations; however, it should be stored in a dry place as heat is released upon solution in water and dry ferric chloride will not catalyze the chlorination reaction.
E. Lime (Code 38800)(Calcium Oxide) T. L.V. 10 Mg/M^ Nuisance Dust
1. Description: Fine white or slightly Rray powder.
2. Formula: CaO
3. Toxic Hazard Rating:
Acute Local: Irritant 3; Ingestion 1, Inhalation Acute Systemic: Ingestion 2; Inhalation 3; Skin
Absorption 0.
Chronic Local: Irritant 3; Inhalation 3 Chronic Systemic: Ingestion 2; Inhalation 2}
Skin Absorption 0.
3
HONS 055795
DEPARTMENT 259
STANDARD MANUFACTURING PROCESS
PYRANOLS AND INERTEENS
APPENDIX J - SAFETY AND TOXICITY DATA
III, TOXICITY
E, Lime (Continued)
4. Toxicology i Has a caustic reaction and, therefore, la Irritating to the akin. As a dust It can cause dermatitis and irritation of the eyes and mucous membranes. It is a general nuisance type of dust.
5. FI re Hazard: None
6. Explosion Hazard: Virtually none.
7. Handling: Dust respirator, adequate protective
clothing, including rubber coated gloves, optional rubber full cover apron and full cover plastic goggles should be used when handling lime (dust). Adequate ventilation and dust removal equipment should be used In the handling area.
Lime is added to the stills to neutralize any liberated HC1 and prevent sublimation of the FeClj catalyst. It is handled in 500 bags.
F. Nit rogen (Code 43101)
TLV Simple asphyxiants. Oxygen content of air must be 18% or higher (equivalent to a partial pressure of 135 mm Hg.)
1. Description: Colorless gas.
2. Formula: N2
3. Constants: Mol. Wt. 28.02 ; M.P. - 210C; B.P. - 195.8*C; Density 1.2506 gr/liter at 0C.
4. Toxicity: None. In high concentrations, it is sn asphyxiant.
HONS 055796
DEFT. 259 - STANDARD MANUFACTURING PROCESS PYRANOLS AND INERTEENS
K- 1 .
APPENDIX K
BACKGROUND INFORMATION
Monsanto began producing Aroclors in 1929 and has been using the dame process In principle ever since. Specifications on Aroclor became more stringent with time. The Gen'eral Electric Company mixed some of the different Aroclors to form products with intermediate physical properties, and named the mixtures Pyranols. Later, Aroclor was mixed with Trichlorobenzene, tri-tetrachlorobenzene, toluene, butyl acetate and cresyl diphenyl to form pyranols with
special properties. As products with lower allowable free organic chlorides were required, chloride scavengers such as tin tetraphenyl, glycldyl phenyl ether and Unox Epoxide's were added to the mi x.
Pyranols at the present time, are formed by mixing Aroclor and Trichlorobenzene. Glycldyl phenyl ether and Unox Epoxide 221 ere
best chloride scavengers now known and are the only chloride scavengers used.
the
Monsanto's Aroclors, especially the chlorinated biphenyls including types 1242 and 1254, used alone or in combination with chlorinated benzenes, are commonly used dielectric materials of the ASKAREL class .
Askarel is a generic name referring to liquid dielectrics derived from halogenated aromatic compounds possessing excellent chemical and dielectric stability and fire resistance over the temperature ranges and operating conditions of transformers and capacitors In the electrical Industry. The electrical industry's use of these fluids have been in accordance with the General Electric Company's patents and developments.
Resulting from the wide use of these materials in the electrical
industry, trade names have been established to Identify them by
different manufacturers of electrical equipment. Listed alpha
betically, the trade names include "Chioroextol," Allis Chalmers;
"Diaclor," Sangamo Electric; "Dykanol," Cornell Dubiller; "Elemex,"
Line Materials; "Hyvol," Aerovox; "Inerteen," Westinghouee
Electric; "Noflamol," Wagner Electric; and "Pyranol," General
Electric Company.
.
The electrical and fire-resistant properties of Askarel type fluids have enabled them to capture a share of the market from the lower-coBt transformer oils.
MONS 05579?
DEPT. 259 - STANDARD MANUFACTURING PROCESS PYRANOLS AND INERTBENS APPENDIX L
L- 1 .
TIME CYCLE
The cost standayd capacity (1973 and 1974) of Dept. 259__for Pyranol la 1.7 M pounds per month, or approximately 20 M pounds per year. The production for 1973 was about 15.0 M pounds. Aside from raw material availability, storage facilities are the limiting factor in Pyranol production. There are no finished goods storage tanks, Tank cars are loaded and drums filled directly from #2, 03, or #4 Mix Tank.
Efficient use of equipment, manpower, and laboratory analysis would indicate that large batches should always be made. The pressure of time may dictate, however, that only a small batch be made, large enough for only one specific order.
The following table shows an approximate time cycle for a 12,000 gallon batch of Inerteen 70/30, or Pyranol A13B3B-3. A batch of Inerteen 54201 CM would take less time because it does not con tain trichlorobenzene.
TIME CYCLE
Step
70/30 or A13B3B-3
54201 CM
1. Charge Aroclor and Chlorobenzene 2. Blend major components
4 hrs. 4
2 hro . -
3. Sample for control and analysis
2
4. Adjust and re-analyze (if necessary) 0-6
-
-
5. Charge chloride scavenger 6. Blend total batch
11
33
7. Sample and final analysis
6. Earth treat and re-analyeis of
10 0-6
10 0-6
electrical properties (if
necessary)
TOTALS
24-36 hrs. 16-22 hrs
From this point on, the batch cycle is dependent upon how the product is packaged. Bulk shipments can be loaded at a rate of 35-50 GPM depending on filter condition. Drums (55 gallon) can be filled at a rate of 40-44 per man per shift.
If for any reason a tank car analysis is out of specification,
the product may have to be unloaded to the mix tank, reworked, analyzed, and reloaded.
HONS 055798
DEPT. 259
STANDARD MANUFACTURING PROCESS
M- 1 .
PYRANOLS AND 1NERTEENS
APPENDIX M
QUALITY CONSIDERATIONS
Pyranols and Inerteens are functional chemicals. Pyranols and Inerteena are used mainly as transformer fluids In the electri cal Industry. Qualities exhibited by Pyranols and Inerteens include excellent chemical and dielectric stability and fire resistance over the temperature ranges required of transformers and capacitors.
Pyranols and Inerteens are manufactured under very carefully controlled conditions In order to meet the strict and exacting
electrical requirements and properties. Good quality Aroclor la essential for producing high grade Pyranols. Any contemplated process change must be carefully evaluated before the actual change la made. Changes in product properties or off-grade products can extensively damage electrical equipment.
MGNS 055199
DEPT. 259
STANDARD MANUFACTURING PROCESS
PYRANOLS AND INERTEENS
APPENDIX N MISCELLANEOUS This section contains the following data: 1. Additional raw material information 2. References 3. 1974 Pyranol Cost Standard 4. 1973 Operations Report 5. Statue Report of Department 246 Safety Audit 6* 1974 Aroclor Manufacturing Improvement Plan
N- 1 .
MOftS 055800
DEPT. 239 - STANDARD MANUFACTURING PROCESS PYRANOLSAND 1NERTEENS
N- 2 .
APPENDIX N (Cont'd)
Raw Materials
1 1CB
TCB is received in tank car quantities from Hooker Chemical Company. The tank cars are sampled and analysed for specific gravity and index. The other properties are determined from the suppliers Certificate of Analysis. Cars are un loaded into a storage tank. Tank trucks are used to supply TCB during times of shortage of material.
2. Aroclor 1242, 1254
Received by pipeline from Department 246.
3. Glycldyl Phenyl Ether
Purchased from Shell Chemical Company in S5 gallon drums, 475 lbs. each.
4. Unox Epoxide (EP-221)
Purchased from Union Carbide in 55 gallon drums. Also known as ERL-4221.
5. Attaoulgus Earth
Purchased in 50 pound bags.
MONS 055801
DEPT. 259 - STANDARD MANUFACTURING PROCESS PYRANOLS AND INERTEENS APPENDIX N (Cont'd)
N- 3.
REFERENCES:
1. St. Louis Report No. 2072, Job No. 2-02-750.01 - 3428, May 4, 1958.
Title: Final Report on Aroclor Process Studies
Summary:
Purity of raw materials, catalyst concentration, reaction temperature, and rate of chlorination were the variables studied with respect to their Influences on the stability of the finished product
2. St. Louis Report No. 2420, Job No. 2-02-750.01 - 2681, January 8, 1960.
Title: Assistance to Sales and Development Departments on Aroclors, Biphenyl and related products.
Summary: Studies were made to measure physical properties and other data on the Aroclor series of compounds.
3. St. Louis Report No. 2540, Job No. 171-616, December 28, 1958
Title: The Effect of Prolonged Heat on the Electrical Properties of Aroclors.
Summary: Aroclors 1232, 1242, 2148 and 1254 were held at 130*C. The power factor was periodically measured.
4. E. E. Martin, Process Deacrlption for the Manufacture of Pyranols and Inerteens, W. C. Krumarich Plant, June, 1962.
5. P. G. Benignus, The Proper Handling of Aroclors and Their Mixtures in the Electrical Industry. St. Louis. Jan. . 1960.
HONS 055802
PRODUCTION COST STANDARD
[effective /-7
MATemA.il
7$DUPLICATE COLS.>4
INTO ALLCARDS
4-OS
/)77fl
6vS f\R7H
vSi-rtf/-/
.
EXP CL
PRODUCT
24-25 29-9) 7>voO
for fewi.
1
Wfl/qt. IM.U/K
as. 93330
f
CfitJ________
9
SUBSTlTUTADLt
ft 0LOC
roRM. * c PKC. u 0
E
MAT'L
STO. YIELD X
94-97 25-40 44 45
46-51 !52-59
\as 0
01
0`
10
0
0 j....
0
0!
0 23? 0
j !
<>w 0 0
! J
0!
0
r-AOr p ,H/M WK|, * Handling
10<m T*i*' Mi'U
Ar' f
SI ' 524
52)
sx
0 0 0 0 0 0
|
1
i } {
Total DvPnif/tM ' Nai Taial Mata.lali
STANDARD PER UNIT
c
54-57 ! 55-60 60 MS
: ova
RAW MAT'L STO UNIT PRICC
HANDLING STD UNIT PRICE
<1-64
65-69 o'iooo 06<SSD
1
1 J 1 s
1/32)
/ frU
1 1 | s 1'
!
11
! J
1
'S' 6*7/10 3SSSO
loasiini.
0.900/3
i
UNIT COST
OP 3
fe^L-. 0*b
\J
MAT'L
CODE
VSAOI LnioO
DATA
MATERIAL fZe
THCO- USAGE JCC / 47.
RACKET!
OatrailM PflU4l DATS lJHIETS CLASSIFICATION
I29
3 11 y.
S4
J AMOUNT
CSt/)hul Down
TMEO, to STD. on
7 1 TYPE PKO. too 23V 0 HWfl
STO LOS
ThEO LOS
\ ThEO/STD
NET LR/PKO 0<e U./Pkj. Nai Lk./Pallai 0-6.1 Ihi.'PtlMt
6 op b)<? US-_____
6 b sr 71? 7 Vo
ivoo iOSb 2 ?o
2 oc-o >960
Caii/Cfcarta aavar Pka. CRariaaevtr Call Pka. Rait Lki./Ma,
CONTAINER!:
Z^SZMmZ
Tv?W &0 ivtvt sr____
b!
~9<5o kio
9>/,
PRICE PEW CONT.
i/so
L\&m J>i3S35tL
CONT- COST/UHIT .SkJOlLfL-
PKC UNIT STD.
C B.R INFORMATION
u, 77
i^r
J&
J3Z
DOWNTIME SUMMARY
P'tCIII Clka*_____ l->*anOfy
____"h[a-i. T oil
On ........ .
IO
%^0 *.9x`5jlL ;2,l/rf\
TOT M.
73" ji____ _
2-.6L
1qs.o /.<-.
HONS 055804
PPUCTIOH COST ST/.KDMTl'
\?y'vlSrfi(2.J&.!li}ms.uzJ>...-
pf.vjfii (Liv| toe OlV. j toe CCWl
'cri i.cuvr'/'-'?yj
J\\okai.
u-w u-?o _J^J jb8s3!e(.mu__ F/oto
juaSaLi5T
iujik inv.
cost
capacity cost wit
-
, '"
. ' ` KM'UUALt
ouruc/rn cols..4.;$ MTO ALLCARUS
CXP ct
PRODUCT
.. toe
RKO.
SUMTlTUTAOtt
%
c 0
MAT'D.
V0 r
STO. YIELD %
STANDARD
PEH UNIT
RAW MAT'L. IT 0, UNIT RfuC
c HAKOLlfiO n sto. umi rmet
jn; cut
. i-n
?6-J6 3?-3)
3-l-3> 3I-J0 J1 a
SI |STS5
JJ-S? |'5-i0 J3 il-!<
SS-S*
HJ-0-J-0-J . ,.e75
rr ft
U'.Ol LOit / J. C`/
-`frr.'T iiQjUV
S25. 4/iiS*? i.y/7g.~Ti-
0
ml- 0
w0 q?t 0
Utatixl-.
sr/nI'MhnA
`Id 'noti
` lo`,f:6o
1 '.............. US-o
60 'fioo
C,1 '.too
Us.-rno iliy//
! Si V?o
fW
. <msi II l5f.O
<tw wt(.i>s kfiam <*K It/oO
9?? 0
1
levs'- -
1Dlooo 1 CO/
'$&{.L '
su ci'>
` . >21 >/Sl&
.:
22 0 0
r i i
0 J_____________ 1
0i
0l
0i
fcW>
J
J 1 1
... 1
-
1
'P'^iro
j0X000 Irodno lolPiL \
on iii cAy<Jr
.-,.T
l
0 i1
j
I
0
} . 1 ..
1
i
0t
1 L_
Jimmie/},o mtii ....... &c_ XelML~
0
Wl 0
! 1
1 no
<s l/p.sob
1 lib!
' <\
rc;.
Teh
. v?s
ill 0
?0 MO
10 toil.
|JtS?0 IT/I/7S-
Afcrvt.r* Ilf*/.................. TV?
Pj^PiKbtH V)C7/1
h! ..*?.*
..
... tttf
..
<r
.
VJ03 m 0
rt>/co
1a 0
Vi'SF/
0
0
0
0
to boo
1
l 1 1
- -< -
10 MO?
.-. 10/1
1 OVD
! J
I
t/^S'3. '/3 W/oi
. 1 0 loan
' 06VSO
lor;*8!
\0*0t>n
,,,w<
liar
fafwt-i
'
0 li
0 !i
1 11
. .
0 i
0i 0J
i
!
1 . .71 1
:SVM? GliPnr, 1 ' fTH/rR.
/\r(otLl>rf
ll</1-
itrrnlW/.AMi CaV/l
rr>/.
tM
.
fits' VrfOO ftf) ' *101 cf>
enf
0
M. 0 /Cwi rti 0
rii 0 m 0
0
0
0
0
0
}
let),
J
bio 1 l
j 1 1
i J
l
lot
...
I .`ao_
1O/Q. 1OI.S1 OHO
1
t {
t 1
1________ 1- 1 !_____
.P UJi&lCL. lil/4
j/77?/
i 09000
_________ |26<2_J
Ofii. -'25
......... \Q?m.., \oxcoo
i nr
'lOTftl- i
JO 1 .Til
i ii
'iRrcto/i It/tl-
i.P/> />/(,
flrf /.Wl
Worrf.
"X 'iu
* .IVI
V/ote p/> tnr>/ o>r msX 'CGI
{',7 t';.**''>
Wf n*r\
r'f
0 0 0 0 0 0 i 0 0. c 0
; 90 I no
/o ieo
i l i i i
{ 1 !
VoSrAtf /C J2<j7
I fto
i
1
1
} ! 1
_______
/( 'I2T
<W7</& JL urn
\0b'/SO
"<VJ
_________iro-"c'/1
I* 0
_________ ilULtJUlJ. '-4
rnTHL\
IcV
" t ' 1 1 -
i 11
' 1_
U-
i i-- [____
MONS 055805
louucv'.cwi cc;v !.tai;p.m:I) iiv.j LOT I X'lV. I 1C
,_____
.H&X-ll-- .J3jluulcJ,~.....
......
<>? isLjvih iuiK mvV: : . COST $_ kr r/,
COST UNIT C.i. rr _
` UATCIUM.S
DUPLICATE COLS.-4.I5 INTO ALUARD*
exr CL
PRODUCT
. LOC
OM.' PKO.
$ l u
*U!* tri/T AOi. c
C MAV .
O 0
TO. YICLO 1
(T/NpAftO Ptl UNIT
RAW /.<A T *L . it o. uiiii pnicj;
c n
HANOUN6 no. uin'i f Rict
c:n
. 4>S
"?6-n "Tm ~
5S a
mm .-2lJ^z --0.1 &. J
45*51 l5MJ ___3-I-S7 ; 33-60 49 51*54 !
r,!/D< l.jrf,,
C//V
--
fund* Qio'iS mi/b
sr $0
n3 WT
m_____
_____c.
/ ___ L
I&CL till L(iC!(-0
A 0 0 0
_____VUM.
Jg!.S.Y7 J9. !Ar>t~
-
--
UMiml
</--& /1
*`/\ I'lfs
-
9 O 0
iii
* 1
-
Ao ! d2>3'
s? j1/*? S)33/
1
1
r
--
--!--
. i i
i-- i;
nl
0 0
1 i
1 i
0 i1
1
fi |
.
--
--
0 9 0
0
>ii i
.
1
-
..
1
s
i t1
i1
t
-- *
0 t1
i
0 it
Ii
0 t i
. .j *
0 i i 9 i ' 1
4 i--
0 0
t J
; i A
0 ll
li
i _j____
1
0 {} 0 i .{
t1
<
0 9
l___
i t
0J
ii i
0 _________i___
0 ii 9 i
1
0 i1
9 ii
1
..
0 9-
1
i `i
i i
Ji
0 1i 0 }
i
!
0 <i i
9 i\
--
1
i * ----
i-- i i
f r.
<r i 9 0t T-
9
i i
-
5
i
t i
i
. i
i_
0 Ji
, .1_____
1
0
9-
1*
;
i
}
Ji
>i
HONS 055806
DEPT. 2*6 - 197k OPERATIONS RZPOPT APCCLORS - 8lj.OO, 811.0*
. ", \
:EODUCTION - TCTAD ARCCL6'RsV*2 . l&M# r. 1^73) ` (38.9SS# in 1972) (*3-5M# in 1971) (*9,JB# in 1970) '
'
703TH
1 ,Ti 1 STB. ! was.
' * `i v ' -- ' j j { . J
; j;
1 MAT j JUTE f JULT ! AUG. ' SEPT. I OCT. j NOV. EEC.
ACTUAL
7628710 !'682932 17756762 26l22C5k 6^8 oqr-t.oAt 79l! 3,6^0.i^3.51? J.5G 2,39i,/3i3.6??.322iT ^7
>-
THEOJL5D
5623710 bS32932 !3756753 2612205! 3,695,9983.041,791 3,640,4413'31'15<? 2 304- 7313,699,322:3.367,415l 2, S32,2`
. .,
29-, 421,-391______ - -
!97(-p!
:_______ ~
liRODUCTICN - ABCCDOPS BP KIND
i7*9,|7 27 '2207263 12761015 i 1737832 7.4 33.164:2.092.2473.396,013^446062 1.303,7772,299,683:1.845,930'1 ,Q;?5. ;
.2*2
i 000*17 I 528225 ! 70*7221 32*730' 681,044- 442,401 670,333 j 648,125 235,674 7?0.6I'9; 723.319 969,8
:-25*_
1606956; 75732*; 6gl026l 21996213; 579,079; 507.140 824,538 1722,963 !
802,232 609,015; 792,966 ; g33 52,996
HONS 0 5 5 6 0 7
'PS CPST TTPLD ON BIPHEUTL Stc. 98.0% (1973 9S.9S) C1972 99.96} (1971 100.75%) ( 1970 100.41%)
j
:
j-------- ---r --- !--
j---------------!-----------1-------------- ;-------- ------- i-----------7------------------i-------------
:!
97.991 'p) ,sq; 99.51! 97.23: 96.79 ! 07.47 I 98.19 ; 99.25 `92.88 I 101.96 1 100.84 i 97,25
TIP!
07.00' 00.7*' 99.66; 99.19' 98.67 j 98.37 j 98.43 j 93.55 ] 98.08 ! 9S.48 j 98.69' I 98.59
AVERAGE QUALITY OF 12212 EG LOTS (1973 Av'g. on 18 Lots: (K18 pp~a;~ i~6~S~,~989~ x
~:c
0.20 1
_
0.38
0.7s| 0.27
0.33 ! 0.40
0.32
EZSISTIVTTT 136^60 !
_ 123*00 17C5*C<101,693 122,335 ; 32,705 49.825
-OVER FACTOR 0.27 !
:0. OF LOTS
21
_ 0
0-26
0.1^ I 0.309
2 ________g_ 2
0.489 '2
0.474
0.500 2- `
ip9; ~ 0.209%)]
0.26
0.21
188.550 113,350
0.276
0.186
1 -3
0.22 114.250
0-22 2
o.n 184,275
0.237
2
CTTA'
- 197- 0?LRA'iIGiv5
Pare 2
T ov MTS - 1076 T.OTS
(197 3 Avgs .
on
_____-
12 3
._ "
Lots:
*0.1.4/_p__p_n";
11o8-7r .0nn2-7T _x m10?' .;r0t.2?2?%?;
00..277'''' ''
DCTH :c
JATT. J i 0.12
- isisTivirr ` 1175C7
FBB* 0.136
2^2222
1 MAR. ! a??.. ! MAT l JUS5
i 0.152i 0.17 1 0.15 ! 0.176
|210223
1 t
_ 11 C-'c"
170,7*2 { 150,015
i orar { 0.16 ! 224,067
1 AtTG. ! 0.186 [223,842
1 SEPT. - OCT. | 0.13 ! 0.12
k.41,500 il7S,810
! SC7. 1 0.12
214,970
! DSC. ' | 0.11 `233.670
rOFER FACTOR 0.29 0.20 [
0.21 ! nod - 0.19 ! 0.22 i 0.21 j 0.217 I 0.19 1 0.21 ! 0.18
1 n ?>
r EFT/HEXA
i 0.189 0.170
o.izd 0.196 ! 0.26 [ 0.206 ! 0.25 ! 0.256 1 0.28 ! 0.34 ! 0.20
! 0.12
I i 1 1 !S 1 ! !!1 i
i Ov T- 11
12 i 15 !
.3* 12 [ 8
! ii - ! w
i8
1 12
[
!6
'I>`0R :irious
.(13 Minor injuries and 0 serious injuries in 1971) (5 xainor injuries and 1 serious injury in 1972) . a mfnor Iniurv and 1.serious injury.in 1973)
0
0!
11
0
! 0:
0t
l| 0 ol 0
0 ! n i0
!i i
ii i0
i iy 1
! '1 10
!0 ;o
UALITY COMRIAISTS ( Formal and Informal)
-J53SR
0
0!
c'
(is in 1973) (16 in 1972)
ol 0
2 i o-
i
J
io
1o
.. _ n 1 n'
HONS 055808
-Rsmw*rr. (1Q7R- o.m . 11.1*?: S.H. h 0: ASS. 5-6). (1972: O.T. 8.2%, E.H. 2.4%; ABS 6.3%)
~7`'r'T'Tvx?
in. 2
: lil.O ! ' 5.9
5-2 1
8.0
6.4 | 14.2 | 18.9 | 13.1 ! 13.2
t n.9
. .T. YTD 1XTRA HRS. H. TTD
iZi .2 2.2 2.2
C .2 :
21.1 !
11.1 12
7.1
! !
9.7 ! 3.8 ! 6.3 !
9.* 0.0 . 5-1
8.9 9.7 j 10.8 j 11.0 I 11.2
0.0 : 0.0 j
6.1
j
0.0
i j 10.2
4.4 ; 3.7
!
1
4.o ? 3.6
1 47
! 11.3 ! 5.3
1 4.4
;i 14.5 . j 11.5 .
i 1.5
i 4.2 .
3S. HRS. ____ 7-5
3-k
C.is
3.8 ' 5.9
1.9
5.1 f 8.3 i 6.i
8.1 ! 7.4 f 9.1
3S.KHS.TTD
7.5
5.5 i
3-7
3.7! 4.1
3.8
.4.0 j 4.5 I *-7 1 5.0
i 5.2 I
5.5
ROCLOR :^ENT0?Y(197R Average: '-Hose . 589M# , Dept. 1 195M#) (1972 Average: Whse. 701M?, Dept
1353Mff)
::-:ss.
IPT. .
?TAL
382885 525280! 53A080 isnoSd
719262 10122901 1292333 79'A
1 1 11021^7
1537570! lS26isi3
1205715
-567,60( 418.800 631,01oj 698,670 j 989,040 789,24C 594,480 1,384,382 912,49< 669,088 1,146,274 970,444 [ 376,272 1.294,12; L.661,942 536,450
.4*9,09< 1,087.88? 1,777,314 1,669,114 k,365,312 2.0S3.36: 2,256,422 1,929,662
i
DE?Tj .S^P1 OPE3ATIOSS KEPOHT
.-
'
'
--FY3A50LS (810.90)
'
*
! PRODUCTION - TOTAL'pYRAKCLS .flB.T7Se in 1973) (ll.ovi in 1972) (l<?.OS?i in 1971) fiv?x
mm
*
i
-iOuTH
1 JA5. ! FS3.
XAR. ! APR. i VAP ! JUSE ! JULY ''AUG. : SEPT. ! OCT. ! NOV. j DEC.
ACTUAL
12301323!1518=13! 1012667'! 739973l.22i.33S7' 5S0! 841,116 ;1,850,264 942,432 il.265,914:1,124.'TO2.1)'!,It
.`CHSDULED' -.CTUAL TTD
12301823:1313913' IOI2667' 73S973 1.22A.333 971 339 ! 84i>146 X85C,264942,432 il,265,9ld 1,124,702,071.15 !'230lS23-3620736-^663^03'5I103376'6.627.?ii 7.509 ,4' J* U;ia293.70aL1-236>1^ 12.502.05J3,626,730
: r E0D~r7T0N - PYBASOLS BY K~jr>
_2l2 ??0
0-30
--I3-B-3B-3 1439
> N037725: 1 527277!
>. !i 1
!;
^661^0j 726026: 12671.71
i ! i
1
381720' 119703!
211639' |
i 1 !
2=2910 557,34? ; 311 ono ' 540,660 884,980 376,390 '648,130 11S172! 563.212 : 492.288 ! 270.550 ,'800,464 1332,746 :542,4Z0'
379.540 945,52c 306,354 .,'781,666
(H39)i [
i-
(1,21s) 1oai : ' : 13,4291
-i
!
32,936 164,820 ;
S
1
232,796 73,314 1i J
i!
233.306 345.37* ij t ';
! !!!!!'
I
-I
I !
!
;
I i i i > III-!!
HONS 055809
/IBLDS (TC3 S td. =S-0 (1973 Actual 96.582)
:cb MO. "C3 YTP
1 07.es ! 102-37; 1 97.88 ! 9S.33>
97.10 08.08 : 98.81 06.75 !
!- | i !
j t t
1 .1 ii
98.68 9S.75
96.00 98.37
* .
' 100.43 . 96.36
0? ??
; 98.48 ; 98.14 i 98.07
f :70^.o" I 95.25
! i i -i
!ii ;
97.40 : 9S.23 ` j
;
!
0- 798.24
7YRANOL
! :n*ventory Y 19 74 Avera.se: Whse.
: .`KSE.
! 292575! 31171s;
:spt.
i 173686! 136729'!
325KJ. Dett. 217M#7 7879S11 50313^ 443.991
132568[ 121521 238.860
235,709 293,360
| 52,388 j 265,471 ; 283'.470 I 117,308 ' 454,848 ! 198.890
'X27.4S1 I369.9U
:ctal
! 731261! 7=3175! 1220519 0?766ri 632.851 ! 529.069 ' 169.696 j 720,319 i 432,360 1497,365
96.698
494
' ^
! 123.060 ' 225,72C
i 219,758 729.364
DUPAHTHKHT 8)l6/?59 '9V1' OPERATIONS REPORT
JANUARY
FKDKUARY
MARCH..
.
Department ?M suffered nearly 2o? downtime in January due to poor quality chlorine. Tills
resulted in some minor shipping delays and necessitated delaying the Aroclor scrubber
Installation until the week of February 18.
At month's end, chlorine quality had returned to near normal.
The ehlorlnators were down 30 hours 1/17 - 1/18 to clean a portion of the IIC.1 off-gas transfer line. A slight improvement was noted in the
chlorlnator 1IC1 back pressure afterwards.
Department 259 set an all time monthly Pyranol production record. Tho January production was 10.6?! greater than the previous high of October
1970.
Problems at the repair track necessitated drain
ing and cleaning two 12'I2 PPO tank cars in the
department for 1016 service. All properties were
within specification on these cars,
Overtime ran higher during the month to keep pace with tho increased product demand. Total Aroclor/
Pyranol inventory at month's end is at a four-year low.
The 11C1 scrubber column(proJect 8020) installation
was completed this month and started-up with only
minor problems. The installation and start-up
accounted for approximately 5 days of chlorlnator
downtime. The scrubber's efficiency will be de
termined next month.
'
R1phenyl availability was tight in February and expected to worsen in March, possibly resulting in Aroclor allocation. Minor chipping delays were suffered in February due to tank car inavallabllltics.
At month's end, instrument problems associated with
tho Densitrol were resulting in some chlorlnator
downtime.
'
Diphenyl was again short in March. The department operated at reduced rates throughout the month, but did not suffer any production outages os a result. Aroclor sales are on allocation and some tank car shipments are being short loaded.
MONS 055810
DtiPAKTMKNT 2i\6/2yj WfH OPERATIONS KKPOKT(Conl'd,)
Aroclor
quality prob]eme(thermal chemica)
chlorides and Monsanto Etal)i.U.ty)developod mid
month. The condition still exists, to a lesser
extent, at month's end. A program was developed
with plant AU&D to attempt to locate the source
ol' the instability problem.
Dcnsltrol instrument troubles cleared up the first week in March when the temperature compensater was "ftno-tuned". The department was down 2k hrs. 3/20 while the 11C1 line between Dept. 236 and Dept. 217 was Dowell cleaned. ffR nhlorlnator air exchanger was changed out 3/l0 with a slight Improvement noted in temperature control.
Tcst6 were made throughout March to demonstrate the
IIC.1 off-gas scrubber(project (i020) . The scrubber is performing as designed, however, this still does not permit Dept. 2<l6 to operate when Dept. 217 is off-line, Project h'138 to eliminate air blowing of crude Aroclor and reduce the water flow to the Bcwer will be in
stalled and started-up the first week in April.
The first tank trailer shipment of Pyranol 70/30 was made to Heavy Duty on 3/20. Modifications for their trailer are necessary before another shipment is made. The new Montar trailer was put into service 3/20.
The Aroclor 12514 stability problems cleared up by
April's end. The program to locate a cause eliminated
many potential sources, but failed to define a specific
cause.
.
'
Project M138 to eliminate air blowing and reduce sewer flows was started-up early April. Thus far the project is a success, although the total scoped water reduction was not realized. Corrosion to the intermediate storage tanks is being cloBely monitored.
Tire Acid Division turnaround J|/13-,l/2l) resulted in over 20# downtime for the month. Diphenyl continued in short supply, however the situation is expected to ease somewhat in May.
MONS 055611