Document v6XG98Ye6DmJX8D5J7GrQq1dZ
r. Niagara Blower Company
Air Conditioning
NIAGARA FAN COOLER
Recommended for comfort cooling, process cooling for photo graphic films, laboratories, dairies, chemical and pharmaceutical plants, confectionery manufacturing, low temperature storage for fruits, meats, food products, fur storage vaults, etc. Gives com plete circulation of air at desired temperature with even tempera ture at all points. Saves space and weight. Refrigerant expands into, aluminum coils which save space and weight over steel pipe coil. Manufactured in seven sizes. See table for capacities.
Write for Bulletin 17 for engineering data.
NIAGARA DISK FAN COOLER
A dependable efficient aluminum cooler for
overhead suspension, saving floor space and
providing the efficiency of moving air cooling
for small storage areas, market coolers, etc.
Manufactured in seven sizes. See table for
capacities.
Niagara Fan Cooler '
Write for Bulletin 25 for engineering data.
Illustration of 3-fan unit.
Manufactured also in 1, 2 and 4 fan units.
NIAGARA COOLING COILS
Tested Cooling Coils as used in Niagara Fan Coolers and Air Conditioners are avail able encased in standard sizes for blast cooling
Niagara Diet Fan Cooler
Manufactured in 7 sizes including 2-fan unit.
installations, Seven sizes--20 in. and 30
in. widths. Steel coils in steel cases or Basic Rating* of Niagara Fan Coolers
aluminum coils in a lu mi num
Model No. R.P.M.
C.F.M.
H.P.
Basic Rating
Niagara Cooling Coils
cases are fur nished as re quired.
Write for Bul letin 16.
1N 2N
3N 4N
1W 2W 3W
1730 1730 1730
1730 1160
1160 1160
2040 3860
5220 7500 4060
7900 11,630
Va 23,400 1 45,850
l'/i 68,600 2 92,700
1 43,000 2 86,200 3 129;200
Basic Ratings--Niag ara Spray C oolers
Modd Fan Motor No. R.P.M. RP.
Pump Motor R.P.M. H.P.
Cu. Ft. Air
Per Min.
Basic Rating
Basic Rating* of Niagara Disk Fan Coolers
Model. Motor No. RP. R.P.M.
C.F.M.
Basic Rating
1 N 1730 1
1730 2
2 N 1730
1730 2
3 N 1730 2
1730 2
4 N 1730 3
1730 2
1 W 1160 iy2 1730 2
2 W 1160 3
1730 2
3 W 1160 5
1730 2
1850
3400
5000 6700
3650 7350
10,600
49,500
89,100 128,000 172,000
97,700 189,000
262.000
These ratings make no allowance for heat generated by motors
129
1218 1913
2215 1926
2230 2636
Vs Vs 1/6
- V* 1/6
Va 2>/z
1730 1730
1160 1160 1160
1160 1160
1100
1060 2850 2900
2770
2810 6000
6,100 10,800
12,200 15,400 20,300
28,100
52,000
Model No. 2636 is a dual fan with horizontal tubes. These ratings for ammonia only.
FACTORS FOR OBTAINING B.T.U. CAPACITY
Temperature of Refrigerant (Brine or Ammonia)
F. +50 + +40 +35 +30 +25 +20 + 15 +10
+5
0
-5 -10
70 65 60 55 50 45 40 35 30 25
20 15 10 5 0
.500 .625 .750 .875 1.000 1.125 1.250 1.375 .375 .500 .625 .750 .875 1.000 1.125 1.250 .250 .375 .500 .625 .750 .875 1.000 1.125 .125 .250 .375 .500 .625 .750 .875 1.000
.125 .250 .375 .500 .625 .750 .875 .125 .250 .375 .500 .625 .750
.125 .250 .375 .500 .625
.125 .250 .375 .500
.125 .250 .375
.125 .250
.125
1.500 1.375
1.250 1 125
1.000 .875 .750
,625
.500 .375
.250
.125
1.625 1.500 1.375 1.250 t 125 1.000 .875 .750 .625
.500 .375 .250 .125
1750 1.625 1.500
1.375
1.250 1.125
1.000 .875
.750 .625
.500
.375
.250 .125
1.875 1.750 1.625 1.500 1.375 1.250 1.125 1.000 .875 .750 .625 .500 .375 .250 .125
2.000 1.875 1.750
1.625 1.500 1.375 1.250 1.125 1.000 .875
.750 .625 .500 .375
.250
temperature and multiply by the basic rating from the table above. To select the Niagara Coolers with capacity to maintain a given room temperature, take from factor table the factor at
desired room temperature and refrigerant temperature. Then divide the required B.T.U. absorption by this factor which will give a required rating. The corresponding rating may be selected from the basic rating table.
564
Niagara Blower Company
Air Conditioning
NIAGARA FAN HEATERS
For the heating and ventilating of large areas, industrial plants storage buildings, etc. Especially recommended for packing plants, dye houses and wherever ventilation is required Niagara Fan Heaters put the heat immediately where needed in the working zone, give quicker heating up to working temperatures, prevent cold floors, cold corners. Definitely built to the highest possible standards and to out-live other heating equipment. Niagara Fan Heaters have welded aluminum heating coils, welded frames, ball-bearing fan shafts and other improvements making for continuous, efficient service. Quiet in oper ation, they may be used to heat both office and industrial spaces. Ducts may be used for distribution to partitioned H rooms. See tables for capacities.
Write for Bulletin No. 14 for engi1 netting data.
'NIAGARA DISK FAN HEATERS
A most effective suspended heater.
Niagara Fan Healer
Lower resistance to air passage gives Illustration of 2-fan unit. Also manu
greater distance of discharge of warm
factured in 1, 3 and 4 fan units.
air, effectively heating larger areas .
and keeping the heat down in the working zone. Operates with lower
l discharge temperature, cuts down roof arid wall losses, diffuses heat
1 better at lower cost, with fewer heaters.
Writefor Bulletin No. SO for capacities and engineering data.
Niagara All Aluminum
DM Pan Heater NIAGARA ALUMINUM HEATING COILS
Designed for use with fan heating systems giving the advantage of
aluminum, light weight and resistance to corrosion to this service.
Manufactured in two widths 20 in. and 30 in. and in two types of three
lengths, each in each width giving a complete range of sizes. Good for
150 lbs. working steam pressure. Completely encased ready for piping
connections. Headers are cast aluminum welded by special process to
U-bend aluminum tubes. Write for Bulletins Nos. 20 and H.
Niagara Booster Heaters, similar in construction to Niagara Alufni-
num Heating Coils are used for reheaters to control room temperature
independently of the fan system.
Niagara Aluminum Healing Coils .
RATED OUTPUT CAPACITIES--Niagara Fan Heaters
Mode! No.
R.P.M.
Motor R P.
Cu. Ft. Air
Per Min.
Entering Air 60 F.
Entering Air 0 F.
Equivalent
5 lb. Steam
5 lb. Steam
Direct Rad.
at 5 lb. Steam
Outlet BTU Temp.F Per Hour
Lbs. Cond. Outlet. BTU Per Hour Temp. F Per Hour
Lbs. Cond. Per Hour
and 60 F. Entering Air
60 Cycle Motors
( 160N 1
1
860 1160
1730
f 860
260N {1
1160 1730
360N
80O
1160 1730
460N I00W
| { 1 ( |
ZWJU, ^[
___
--- 1
8i0 1160 1730
860 1160
860 1160
860 1160
Vs 1315 /* 1775 Vi 2175 7* 2500 % 3330 1 4000
M 3620 Vi 3970 m 5920 Va 4000 Va 5360 2 8000
\ 4340 1 4340
2 8680 2 8680
3 12,600 3 12,600
134 129 124
134 129 124
134 132 124
134 126 120
124 124
124 124
124.5 124.5
95,700 121,000 128,300
182,000 226,000 261,000
263,000 269,000 377,000
287,000 348,500 480,000
274,000 274,000
542,000 542,000
800,000 800.000
99 125 133
188 234 270
272 277 391
292 360 492
277 277
554 554
80S 808
565
100 128,000 133 94 165,000 171 87 188,000 (94
too 244,000 252 94 309,000 407 87 354.000 361
100 353.000 360 98 364,000 371 87 513,000 525
100 386,000 393 89 468,000 480 82 653,000 666
All steam pressures to 200 lbs. and entering air temperatures .. -- 20 to 160 F. are given in N. B. Co. Bulletin No. 3.
416 526 556
790 965 1135
1145 1170 1640
1250 1515 2085
1190 1190
2380 2380
3475 3475
-