Document v6VbOd5gOE6Mao3LQLM6Bx4ab
Monsanto
MONSANTO INDUSTRIAL CHEMICALS CO. 600 N. Imctbcgh Boulevard St. lOuij. Missouri 63166 Phone; (314) 694-1000
December 4, 1975
Dr. Eunice Moore Electrical Utilities Co. LaSalle, Illinois 61301
Dear Dr. Moore:
Vie have completed the analysis for PCB's in the air at your facility. Thermal desorption of the sample into a gas chromatograph and comparison with standards provided the qualitative and quantitative data. In the table are listed levels of PCB's found, with a detection limit of 0.1 pg/1 and accuracy of + 0.1 pg/1. The threshold limit value for PCB's (425 chlorTne) is 1.0 pg/1 and PCB's (545 chlorine) is 0.5 pg/1. We have been glad to provide you with this service and hope it meets your satisfaction.
Sincerely
ss Enclosure
cc: R. H. Munch
bcc: L. M. Chapman R. E. Keller
Dr. Martin W. Dietrich Senior Group Leader Applied Sciences
nl of Monsanto Ct o*nv
MQNS 092309
Location Plugging Area #1 Plugging Area #2 Press Department #3 Assembly Department #4 Impregnation Department #5 Winding Room #6 Plant Manager's Office #7 Standard #8
Aroclor 1016 1.7 pg/1 2.3 pg/1 0.4 pg/1 0.5 pg/1 0.7 pg/1 0.2 pg/1 ND < 0.1 ND < 0.1
Pump flow Sampling time Sample volume
88 ml/min 1-5 hrs. 5-30 liters
MONS 092310