Document v6QrgnRdR67xd4zJv80VRO6dY

/.... Monsanto AROCLOR* HDK-1 Technical Data Sheet April 25, i960 .M DEVELOPMENT DEPARTMENT (S' MONSANTO CHEMICAL COMPANY ORGANIC CHEMICALS DIVISION ST. LOUIS 66, MISSOURI TO ASSIST YOU IN THE EVALUATION OF THE A6OVE PRODUCT, WE HAVE OBTAINED THE INFORMATION CON TAINED IN THIS BULLETIN FROM LITERATURE SOURCES AND PRELIMINARY INVESTIGATION IN OUR OWN LABORATORIES. WHILE WE BELIEVE THE INFORMATION IS ACCURATE, WE ASSUME NO RESPONSIBILITY AND DISCLAIM ANY LIABILITY INCURRED IN USING THESE DATA OR SUGGESTIONS. ONLY QUALIFIED TECHNICAL PERSONNEL SHOULD WORK WITH THIS PRODUCT UNTIL SUBSEQUENT STUDIES JUSTIFY ITS USE IN YOUR PROD UCTS OR PROCESSES. OBVIOUSLY NOTHING IN THIS BULLETIN SHOULD BE CONSTRUED AS A RECOMMEN DATION TO USE ANY PRODUCT IN CONFLICT WITH EXISTING PATENTS COVERING ANY MATERIAL OR ITS USE. Aroclor HDK-1 is a chlorinated biphenyl product, similar chemically to Monsanto's other Aroclor products in the 1200 series. It was developed to provide the electrical industry with an Aroclor product with a higher dielectric constant than is now available, and was designed to be com parable in all other respects to Aroclor 1242. Listed below is a com parison between the physical and electrical properties (typical) of Aroclor 1242 and Aroclor HDK-1. Form Aroclor 1242 Practically colorless mobile oil Aroclor HDK-1 Practically colorless mobile oil Color, APHA Scale Total Acid Number, Mg. KOH/g. 30 0.001 10 0.002 Inorganic Chlorides, ppm. NDA NDA Refractive Index at 25*C. 1.6249 1.6218 Pour Point, "C. Water, ppm. Distillation, *C., Corrected: 10$ (by weight) 90$ (by weight) Monsanto Stability Test, ppm. Cl -19 29 330 353 0,15 -20 35 322 3bl 0.18 Hydrolysis Stability Test, ppm. Cl 0.21 0.14 Flash Point - Cleveland Open Cup 348 - 356*F, 34o*F. Total Organic Chlorine, $ 42.0 40.0 * Trademark, Reg. U.S. Pat. Off. '.015066 TOWOLDMONOQ43782 Aroclor 1242 Aroclor HDK-1 Specific Gravity (by hydrometer) at 25 C. at 50*C. at 75C. at 100*C. 1.389 1.362 1.334 1.306 1.357 1.336 1.316 1.288 Viscosity at 100'F. at 130F. at 210*F. 17.2 cs 8.0 cs 2.5 cs 12.68 cs 6.26 cs 2.06 cs Dielectric Constant As A Function Of Temperature And Frequency: Aroclor 1242 Temp.*C. 60 cy., lkc. 10 kc. 100 kc. 100 4.90 4.90 4.90 4.90 50 5.52 5.52 5.52 5.52 25 5.85 5.85 5.85 5.85 0 6.20 6.20 6.20 6.20 -20 6.65 6.65 6.00 3.60 -25 6.80 6.40 4.00 3-00 -50 2.95 2.75 2.75 2.75 Aroclor HDK--1 Temp.*C. 60 cy. lkc. 10 kc. 100 kc. 100 5-55 5-55 5.55 5-55 50 6.31 6.30 6.30 6.30 25 6.77 6.76 6.77 6.77 0 7.34 7.34 7-36 7.36 -20 7.89 7.83 7.81 6.49 -25 8.04 7.96 7.84 5.36 -50 3.15 2.86 2.80 2.79 Power Factor As A Function Of Temperature And Frequency: Aroclor 1242 Temp.*C. 60 cy. lkc. 10 kc. 100 kc. 100 6.00 0.50 0.10 0.10 50 3.50 0.30 0.10 0.10 25 2.50 0.10 0.10 0.10 0 0.80 0.30 0.10 1.50 -20 0.40 3.00 19.00 25.00 -25 1.00 12.50 31.50 12.00 -50 5-50 1.00 0.40 0.30 -2- 0l50b6b TOWOLDMONOQ43783 Aroclor HDK-1 Temp.*C. 100 50 25 0 -20 -25 -50 60 cy. * 6.80 3.30 2.50 0.60 0.89 0.80 12.10 lkc. 0.80 0.20 0.10 0.30 0.32 1.30 2.90 10 kc. 0.10 0.10 0.10 0.10 3.28 7.00 0.60 100 kc 0.30 0.20 0.10 0.10 29.30 26.90 0.90 * One additional treatment with 1$ Attapulgus earth lowered the power factor to 1.4$ and raised the resistivity to 4600 x K>9 ohm-cm at 100G. Resistivity As A Function Of Temperature: Temp.*C. Resistivity (ohm-cm) Aroclor 1242 AroclorHDK-1* 100 1000 x 109 2,500 x 109 50 3800 x 109 14.000 x 109 25 7000 x 109 22.000 x 109 * Laboratory treated sample. Aroclor 1242 Dielectric Strength at 25*C. 40-45 KV Aroclor HDK-1 43 KV Toxicity Physiological properties of this material have not been determined. Animal toxicity data obtained with analogous compounds indicate that repeated and prolonged skin con tact should be avoided. Further, if the material is heated so that volatilization occurs, inhalation of vapors should be avoided. MMcE:eh 4/25/60 - 100 Attachments (2) 0150656 TOWOLDMONOQ43784 IC CO TOWOLDMONOQ43785 TOWOLDMONOQ43786 -5- PERCENT' POWER FACTOR , PERCENT POWER FACTOR