Document v6K73abO8VnEe9L7N44akQj2Y
ELEVATORS AND PLANT RAILWAYS
NOTE SPECIFICATIONS FOR HIGH PLATFORMS SERVING REFRIGERATOR CARS ARE 4 FT VER TICALLY FROM THE TOP OF THE RAILS AND 8 FT HORIZONTALLY FROM THE CENTERLINE OF THE TRACK. WHERE 8 FT HORIZONTAL CLEARANCE IS NOT AVAILABLE, HEIGHT SHOULD NOT EXCEED 3 FT-3 IN.
HIGH TENSION POWER LINE^
ADJACENT STRUCTURES
TO tOF ADJACENT MAIN LINE TRACK 15 FT MIN
TO iOF ADJACENT SWITCH TRACK 14 FT
ENGINEHOUSE DOORS
BUILDING DOORS, ADJACENT STRUCTURES, AND HIGH PLATFORMS
OK IF STANDARD CLEARANCE EXISTS ON OTHER SIDE OF TRACKS
LOW PLATFORMS
*3 FT-7 IN RECOMMENDED HEIGHT FOR AVERAGE CAR
TOP OF RAIL-
c
PLATFORMS OTHER THAN THOSE SERVING REFRIGERATOR CARS
Kg. 19-13 Clearances for stondard gouge tracks Specific requirements In each state should be checked (Drawing above is not to scale)
Bated on information mpplied by American Railway Engineering Auocietion (Enginea-mg Divmon, Aiiociation of American Railroadi)
10-25