Document v6BpQkGd2dgO1g9xO2Q36DXpw

1 PLAINTIFF'S EXHIBIT CAP-1799 l CAPCO PIPE COMPANY, INc\ | A Subsidiary of ASARCO Incorporated ASBESTOS CEMEOT PIPE ; : MATERrAt: SAFETY* DATA-SHEET?#^.. Ai// GENERAL INFORMATtONT TRADE NAME (COMMON NAME OR SYNONYM) CAPCO Asbestos Cement Pipe FGL PRODUCT CODE 0 CHEMICAL NAME Asbestos-Silica-Portland Cement Mixture < FORMULA Si02-3t^O*2Si02*2H20-Na20*Fe203*3FeQ*8Si02*H20-Cement MOLECULAR WEIGHT NOT APPLICABLE ADDRESS (No.. STREET, CITY. STATE AND ZIP CODE) Capco Pipe Company, Inc. P.O. Box j435 Birmingham, Alabama 35205 ? V- CONTACT PHONE NUMBER General Information - Department of Environmental Sciences DAY 801-262-2459 NIGHT 801-943-1754 First Aid Information - (Dr. C. H. Hine) DAY 415-777-2213 NIGHT 415-777-2214 Transportation Emergencies - CHEMTREC 800-424-9300 ISSUED DATE 3/14/83 REVISED DATE 3/14/83 ...................... * MATERIAL OR COMPONENT Asbestos (chrysotile, crocidolite) Silica (Si02) C.A.S. ft 1332-21-4 1480-60-7 WT. % PERMISSIBLE AIR CONCENTRATION 15-20 2 fibers/cc L0 fibers/cc - ceiling 30-35 10 % Si02 + 2 1 OSHA ACGIH OTHER Inhalation: No first aid is required for inhalation. Consult a physician if symptoms of chronic exposure develop. Skin or Eyes: Plush with plenty of water. If symptoms develop, consult a physician. CAPCO JEN 0004582 liDi. HAZARDS INFORMATION _______________ HEALTH______________ __ ______________________________________________________________________________ _ _____ c3ttOTicNinhalation of dust may cause silicosis or asbestosis with symptoms of labored / breathing, chest pains, weakness and chest tightness. ingestion " None reported. skin '` o Dermatitis may result from exposure to cement dust. "" EYES ` Eye irritation may occur from exposure to dust. MEDICAL CONDITIONS POSSIBLY AGGRAVATED ' ~ Diseases of the lungs. UNUSUAL CHRONIC TOXICITY " Lung and gastrointestinal cancers or mesotheliomas may occur. increases the probability of these diseases occurmg. j "~ Cigarette smoking................. FIRE AND EXPLOSION FLASH POINT C AUTO IGNITION NOT APPLICABLE TEMPERATURE OPENCUP CLOSED CUP NOT APPLICABLE UNUSUAL FIRE AND EXPLOSION HAZARDS C FLAMMABLE LIMITS IN AIR (% BY VOL.) NOT APPLICABLE None. Asbestos materials do not burn. E-. PRECAUTIONS/PROCEDURES*' FIRE EXTINGUISHING AGENTS RECOMMENDED NOT APPLICABLE FIRE EXTINGUISHING AGENTS TO AVOID NOT APPLICABLE SPECIAL FIRE FIGHTING PRECAUTIONS Use NIOSH/MSHA. approved self-contained breathing apparatus and full protective clothing if involved in fire. ENGINEERING CONTROLS Local exhaust ventilation is required for sawing , sanding, cutting, beveling or other ooeratiohs which generate dust to keep exposures below permissible exposure levels. Use wet methods where possible._____________________ NORMAL HANDLING Keep dust to a minimum during all handling. Wet methods should be used where possible. STORAGE General storage procedures acceptable. SPILL OR LEAK A clean-up procedure which minimizes exposure is required. Vacuuming is preferred. Place all material in closed containers. Do not_use_compressed air for cleaning. Use water or other dust suppressants where sweeping is unavoidable. SPECIAL: PRECAUTIONS/PROCEDURES/LABEL INSTRUCTIONS Signs and labels in work areas and for contaminated containers or equipnent may ba required under OSHA regulations. Medical examinations, monitoring, recordkeeping and hygiene facilities and practices specified by OSHA may na^b^ps{^,^p^|d; PERSONAL HYGIENE Practice area. Take 9 home. No tobacqo or food in work _ stion or inhalation. change clothes attend of shift. /Do'riot wear contaminated Do not use conpressed air for blowing dust off of clothes.________________ CAPCO JEN 0004583 ( PERSONAL PROTECTIVE EQUIPMENT .[respiratory protection A NIOSH/MSHA approved respirator for toxic dust is required if the permissible exposure level may be exceeded. EYES AND FACE Safety glasses recoirmended where the possibility of getting dust particles in eyes exists HANDS, ARMS, AND BODY ^ E\ill protective clothing such as coveralls or similar.whole body clothing, head coverings, gloves, and foot coverings is required if the permissible exposure limits may be exceeded, This protective clothing should not be worn home. Laundering should be provided. Contaminated clothing should be transported in sealed . labeled impermeable bags. OTHER CLOTHING AND EQUIPMENT NOT APPLICABLE MATERIAL IS (AT NORMAL CONDITIONS): LIQUID S SOLID BOILING POINT NOT APPLICABLE MELTING POINT NOT APPLICABLE SOLUBILITY IN WATER (% by Weight) GAS INSOLUBLE EVAPORATION RATE (Butyl Acetate = 1) NOT APPLICABLE (Ether = 1) APPEARANCE AND ODOR Light gray, odorless Various shapes and sizes SPECIFIC GRAVITY (H20 = 1) 1.77 pH NOT APPLICABLE % VOLATILES BY VOLUME (At 20 C) NOT APPLICABLE [fife ..REflCTlVITYDATAy STABILITY C UNSTABLE g STABLE CONDITIONS TO AVOID NOT APPLICABLE INCOMPATIBILITY (MATERIALS TO AVOID) NOT APPLICABLE HAZARDOUS DECOMPOSITION PRODUCTS NOT APPLICABLE HAZARDOUS POLYMERIZATION C MAY OCCUR g WILL NOT OCCUR CONDITIONS TO AVOID not applicable r> VAPOR DENSITY (AIR = 1) NOT APPLICABLE VAPOR PRESSURE (mm Hg at 20 C) (PSIG) NOT APPLICABLE CAPCO JEN 0004584. IKKlSSiS EPA HAZARDOUS SUBSTANCE? IT fl IF SO. REPORTABLE QUANTITY: YES NO - \ \\ If; # <' c WASTE DISPOSAL METHODS (DISPOSER MUST COMPLY WITH FEDERAL, STATE AND LOCAL DISPOSAL OR DISCHARGE LAWS) Dispose of asbestos material in accordance with EPA regulations 40 CER 61.20, National Emission Standard for Asbestos (Clean Air Act). All chips, cuttings and dust should be collected, placed in sealed bags, labeled and-iSisposed in an approved landfill. RCRA STATUS OF UNUSED MATERIAL: 40CFR Material should be considered a solid waste under RCRA and should be disposed c f 261 in accordance with EPA regulations 40 CER 257. - - PERMISSIBLE CONCENTRATION REFERENCES OSHA Regulation 29 CFR 1910.1001 . ,, OSHA regulations for airborne contaminants 29 CER 1910.1000 HAZARD INFORMATION REFERENCES "Documentation of the Threshold Limit Values," 4th Ed., ACGIH Patty's Industrial Hygiene and Toxicology, Vol. 2A, 3rd Rev. Ed., 1981 Hamilton,A. and Hardy,H., "Industrial Toxicology" 3rd ed., 1974 GENERAL ANSI Z9.2-1971, Fundamentals Governing the Design and Operation of Local Exhaust Systems ANSI Z88.2-1969, Practices,for Respiratory Protection American Water Works Association, Manual c-16 CAPOO Installation Manuals Asbestos Cement Pipe Producers Publications ( jfC. AODCnQNAE. INFORMATfONA Information (hazards, precautions, first aid, etc.) is abbreviated. More detailed information is contained in references found in Section J. CAPCO JEN 0004585