Spray Drying Sodium Metanilate
in s id e
STANDARDS
PtANT-61ianlm!S_iQrl^AREf4m~IiipJlSUILD!NG_Mft2-.1^3B
OUTSIDE STANDARDS
TECH.
EQUIP.
cm cm
pu r po s e o f t e s t : To determine whether sodium metanilate can be spray dried satisfactorily and economically.
s t a n d a r d in v o l v ed : Chambers Works Process for the Manufacture of Sodium Metanilate, approved May 17, 194$
d u r at io n o f TEST: About 500 lbs. of sodium metanilate will be dried during April and possibly another 1,500 lbs. in later months.
t es t d et ail s :
{INCLUDE SAFETY)
See attached sheet.
PREPARED BY:------------------------------------------------------ RESPONSIBLE FOR TEST:____................ .Bny.lea
--_
_____________________________________________________ ____ -.........................
APPROVED BY:
DATE DATE e&t e "
au t h o r ized s/a/CL.-L*. Richardson_______
DATE DATE
MU-17S*
DATE DATE
4~S~57
DATS
7 DATS
N32986
DUP050467675
TAg 5?~163
-2-
April 8, 1957
Test Details; (Include Safety}
1. Start v/ith the following conditions:
Slurry:
Temperattars of Slurry: Chamber 'Temperature: Drying Air Temperature: Atomizing Air Temperature:
35-50$ Solids (depending on , available starting material) Ambient 110Cd 250C
300C. (15 lbs. of atomizing
air per pound of slurry)
2q Dry slurry tarsier the above conditions for about an hour.
3. Follow the Instructions described in Exhibit B-2, B-3, B-4 and B-~5 for the establishment of optimum conditions, determina tion of drying rates, product testing and safety precaution as outlined in C.W.P.T.S, Report No. 555-P.
The initial conditions were established by preliminary spray
drying tests in the experimental Bowen Spray Dryer at Unit Process Laboratory,
Tests at Aso Laboratory have shown that dried sodium metanilate is neither explosive nor flammable .-under usual conditions.