Document v626banxZGEQqV6xkL14Bz3Y8

TOT AUTHORIZATION MQ. TJLrP-SZf.163 DISTRIBUTION: S. G. Ford, Orchem, Wilm. R J. Plunkett, Orchem, Wila. J, A. Kelson, Jackson Lab*) In Jackson Lab. Piles )Turn A. 0. Bradley, Adm. Bldg . R0 Hurka, Adm. Bldg. W. 0 Jewett, Adm. Bldg D* B Kirk, Methods & Stds. P Lanrsen, Miss* InC . J* T. Linster, P.T.S. Off .& Lab. (2) C. L. Richardson, Adm. Bldg. t it ; p- Spray Drying Sodium Metanilate in s id e STANDARDS PtANT-61ianlm!S_iQrl^AREf4m~IiipJlSUILD!NG_Mft2-.1^3B OUTSIDE STANDARDS TECH. EQUIP. cm cm pu r po s e o f t e s t : To determine whether sodium metanilate can be spray dried satisfactorily and economically. s t a n d a r d in v o l v ed : Chambers Works Process for the Manufacture of Sodium Metanilate, approved May 17, 194$ d u r at io n o f TEST: About 500 lbs. of sodium metanilate will be dried during April and possibly another 1,500 lbs. in later months. t es t d et ail s : {INCLUDE SAFETY) See attached sheet. PREPARED BY:------------------------------------------------------ RESPONSIBLE FOR TEST:____................ .Bny.lea --_ _____________________________________________________ ____ -......................... APPROVED BY: DATE DATE e&t e " au t h o r ized s/a/CL.-L*. Richardson_______ DATE DATE MU-17S* DATE DATE 4~S~57 DATS 7 DATS N32986 DUP050467675 TAg 5?~163 -2- April 8, 1957 Test Details; (Include Safety} 1. Start v/ith the following conditions: Slurry: Temperattars of Slurry: Chamber 'Temperature: Drying Air Temperature: Atomizing Air Temperature: 35-50$ Solids (depending on , available starting material) Ambient 110Cd 250C 300C. (15 lbs. of atomizing air per pound of slurry) 2q Dry slurry tarsier the above conditions for about an hour. 3. Follow the Instructions described in Exhibit B-2, B-3, B-4 and B-~5 for the establishment of optimum conditions, determina tion of drying rates, product testing and safety precaution as outlined in C.W.P.T.S, Report No. 555-P. The initial conditions were established by preliminary spray drying tests in the experimental Bowen Spray Dryer at Unit Process Laboratory, Tests at Aso Laboratory have shown that dried sodium metanilate is neither explosive nor flammable .-under usual conditions. CCG; nc DUP050467676