Document v1Xkk9eKoKx3vz8wpe5JbVMQE
FILE NAME: Asbestos Information Association (AIA)
DATE: 1975 Feb 26
DOC#: AIA002
DOCUMENT DESCRIPTION: Letter to the AIA from S. Holmes RE Insulation Hygiene Progress Report
Mr. J. Marsh.
Mr. R.H. Mereness,
Executive Director,
:
Asbestos Information Aasociation/NA,
1660 L Street N.W.,
Washington D.C.20036,
U.S.A.
26th February, 1975*
SHs/CMT Copy! JJV'RM.
Dear Bob,
Insulation Hygiene Progress Report -
Volume 6 No. 1
"
,
Thank you for sending me a copy of the above report, which I have read with considerable Interest.
The burden of the argument seems to be that dust measurements J Showing a low average level may be deceptive In insulation workers where exposure Is intermittent and may Include high peaks of short duration. As It is believed that disease nay be associated with these high peaks the validity of a , standard such as the 2 flbre/ml U.K. standard. Is called Into \ question.
For some considerable time now, I have talked about the
.
significance of high peak exposures and recommended that
safeguards to cover such situations should be built-in to
standards. In my evidence at the Public Hearing In Washington
in March 1972, I Included the following statement on the U.K.
standard:-
"It was realised from the beginning that the standard had certain limitations. The Information on which It was based was scanty and was drawn from a textile plant, where dust concentrations did not fluctuate widely. That It might be unwise to apply It to situations experiencing high peaks of concentration was recognised and it was reconrnended that the time/concentratlon concept should not be used above 10 flbres/cnP, because too little was known about the effects of high concentrations for short periods of time, which might Interfere with the normal lung clearance mechanisms."
Cont'd
i
ASDeatos imormation HSBoui.auaon/J'** Washington.
Again in my final recommendation I said the following: -
I "It ia my view that a sizeable part of the health
problem facing the asbestos industry today la due
to the effect of peaks of very high dust concentration, albeit only for short periods, . attending uncontrolled operations, such as are w L encountered in the Insulation industry. A iit.anrijirti which removes the worker from the effect of such peaks is probably more important than one which imposes unreasonably strict average levels."
I returned to the same argument in my paper entitled "Environmental Data in Industry" at the Lyon Conference in October 1972 where I said:-
"It is well known that the threshold limit value of 2 fibres/ml was calculated from the BOHS chrysotile standard, assuming an occupational exposure of 50 years. While this may be desirable for persons working full-time with asbestos,. it is probably too tight a standard for many asbestos users who handle the material only intermittently. Hie possible effects of intermittent high dust concentrations have already been referred to; it is therefore recommended .. that*. whatever threshold limit value (TLV) is stipulated (based on the average concentration over, say, 4 hours) exposure of the worker to peaks higher than five times the TLV (measured over 10 minutes) should be avoided."
3he Factory Inspectorate in the U.K. in operating the 1969
Asbestos Regulations have shown that they are aware of the
situation by saying that while the TLV based on a 4 hour
sample shall be 2 fibres/ml,levels above 12 fibres/ml, based
on a 10 minute sample are not permitted. If the situation
cannot be improved by tighter dust control, then the workers
must wear respiratory protection. Ihis is obviously directed
at the insulation industry and its effect is to prevent the
worker being exposed to these high peaks of concentration.
Surely this is better than pitching the average level very
low indeed to take into account the possible high peaks which
might occur.
'
'
I hope these corments will be of help to you and I am sending a oopy of this letter to John Marsh.
With kind regards,
.
Yours , sincerely
S. Holi^a^"^
/
4