Document v1BgwLpGK1zb6YV7q8aX6N1x9

oENT BY: 4- 2-83 : 9:13AM : BRADLEY AND MERRELL 13144210239:# 6/15 THE PROPER HANDLING OP AR0CLCR3 AM Tiffim MIXTURES IN THE ELECTRICAL INDOSTRY p. a. Benignus 12/1/5* Monsanto Chemical Co. Organic Div. Sales Dept. 800 N. Delmar Blvd. St. Louis* MO. ^TIFF'S EXHIBIT \ 'f' p r> r\ ACM 001611 WATER PCB-SD0000025953 SENT BY: 4- 2-83 : 9:13AM : BRADLEY AND MERRELL- 13144210239- 7/15 Introduction Chapter 1 Chapter 2 Chapter 3 Chapter 4 Chapter 5 Chapter 6 Chapter 7 Chapter 8 Chapter 9 INDEX The Proper Handling of the Aroclors and Their Mixtures in the Electrical Industry. Procedure for Unloading Tankcars of Aroclors and Their Mixtures. A. Description of the Cars. S. Procedure for Unloading the Cars. A. General Description of Storage Tanks. 8. Detailed Description of Storage Tanks. Gasketing and Pump pecking. Sampling. Laboratory Analysis and Procedure for Treating Aroclors and Their Mixtures. Test procedures. Typical properties. Earth Treatment of Aroclors and Their Mixtures in the Electrical Industry Prior to Use. Dermatology and Toxicology, Attachments Drawing No. 31-208^8, Dome Detail. Drawing No. 31-20847, The Tank Car. Drawing No. 9C-8170-5i The Horizontal storage Tank. Drawing No. D-13362, The Vertical Storage Tank. Drawing No. 9C-8248, The Breather. Drawing No. 9C-8278, The Varec Gauge. Drawing No. 9C-8178, The Unloading platform. Knnno?!7 ADM CO 1 81 2 WATER PCB-SD0000025954 SENT BY? ? f 4- 2-83 : 9:13AM ' BRADLEY AND MERRELL- 13144210239-S 8/15 I : I II } 1i i,nnon?8 A OH 00*217 WATER PCB-SD0000025955 atM tsr 4- 2-a^ : a-14AM : BKADLht AND MtRRtLL- iai4A2iu2aa^ a/15 v.nnnn?.9 ` <i ADH 002218 WATER PCB-SD0000025956 SENT tsr- 4- 2-83 3: HAM : BRADLEY AND MEKKELL 13144210239'. si 0/15 CHAPTER 9 CER-MATOLCCY AND TOXICCLCCY to the extent of 5^.* by weight) applied zo gauze ar.d placed In contact with the akin showed no primary irritancy cr sen sitization. The teats were conducted under competent medical supervision and the standard procedure recommended by :r3 . Louis Schwartz and Samuel M. peck. Reprint No. 2552, Public Health Reports, Vol. 59j No. 19 (April 28, 1944) was used. If Aroclors are spilled on the skin, the 3<in should be washed In the usual m.anr.er with soap solutions. If accidental burns occur from contact with hot Aroclors, the burn should be treated the sane as any ordinary bu; . Aroc icr adhering to the burned area need not be removed -.tedlately unless treatment of the burn demands It, In which case use scap and water or repeated washings with a vegetable oil. At ordinary temperatures Arcclors have nc: presented industrial toxicological prctler.s. If Aroclors are used at elevated temperatures ir. open systems, methods must be designed to exhaust ar.y vapors arising. Experimental work on animals indicarss that the auaxlnua safe concentrations of vapors In workrooms is in the range cf 0,5 to 1.3 milligram per cubic meter of air. This applies to all of the liquid Aroclors. Laboratory technique merely requires keeping zr.t hand3 73 ttnnonao AON 001865 WATER PCB-SD0000025957 M;N! BT- 4- 2~6B ; y i4AM BKAULLT AM) MtKKtLL-' lB14421U2By:sll/lo free of th liquid and handling It under a well ventilated hood. _ Localized or spot ventilation together with general work room exhaust 1b recommended for plant operations. When sampling tank cars, canvas gloves and safety glasses or goggles should be worn. No special clothing la required, but the worker's garments should be laundered at least weekly and changed In case Aroclor or Aroclor mixtures is spilled cn the clothes accidentally. If workmen are exposed to Aroclor vapors at relatively high levels, as may be the case when opening a heated capacitor Impregnating chamber, a respirator should be worn during these short Intervals. The many years of satisfactory ar.i safe use of a roc lors and their mixtures with chlorinated benzenes In the electrical Industry for impregnating capacitors and filling transformers has demonstrated the Industry's ability to handle these fluids without hazard to the workmen. It Is a simple natter and in line with good "housekeeping" and personal cleanliness to ixar elii the suggested and required precautions in all cases. jk F,000031 AOH 001866 WATER PCB-SD0000025958 sent by: 4- 2-83 : 9:HAM : BRADLEY AND MERRELL^ *^ 13144210239-12/15 , THE PROPER HANDLING : OF AROCLORS AND THEIR MIXTURES IN THE ELECTRICAL INDUSTRY --v-- Monsanto Monsanto Chemical Co. Organic Oiv. Sales Depf. 800 N. Twelfth Blvd. St. Louis, Mo. ADM 001266 P. G. BENiGNUS MAY ' ,9" IWM03? WATER PCB-SD0000025959 4- 2-83 : 9:14AM : BRADLEY AND MERRELL- 13144210239:#13/15 XNDEX Introduction Chapter 1 Chapter 2 Chapter 3 Chapter 4 Chapter 5 Chapter 6 Chapter 7 Chapter 9 Chapter 9 The Proper Handling of the Aroolora art Their Mixture* in the Slaetrioal Industry. Procedure for Unloading T*nkcars of Aroolora and Their Mixtures. A. Deeerlption of the Cars. B. Prooedure for Unloading the Cara. C. Dm* Ptctaglng Storage Tanka A. General Description of Storage Tanks. B. Detailed Description of Storage T*nke. Gasketing and Pump Packing. Stapling. Laboratory Analysis and Procedure for Treating Aroclors and Their Mixtures. Test Procedures. Typical Properties. Earth Treatment of Aroclors and Their Mixtures in the Electrical Industry Prior to Use. Dermatology and Toxicology. Attachmenta: Ho. 31-20848, Dome Detail. Bribing No. 31-20847, The Tank Car. Drawing Mo. 9C-3170-5* The Horizontal Storage Tank. Drawing Ho. D-I3362, The Vertical Storage Tank. Drawing Ho. 9C-o243, The Breather. Drawing No. 9C-8279, The Varee Oauge. Drawing No. 9C8l78, The Unloading Platform. ADM 001267 ehnflnas WATER PCB-SD0000025960 StJN I fc>Y: 4" ; a: 14AM tSKAULtT AiMJ MtKKtLL- lJi442iU23b--14/io t . CEAPTM 9 " DERMATOLOGY AMD TOXICOLOGY Skin patch testa using Aroolor 1254 (biphenyl Chlorinated to the extent of 54$ by weight) applied to gauze and placed in contact with the akin showed no primary lrrlteney or sensltlzatlon. Tha tests were conducted under competent medical supervision and the standard procedure recommended by Dri, Louis Sohwartz and Samuel M. Peek, Reprint Ho. 2552, public Health Reporta, Vol. 59, No, 19 (April 28, 1944) was used. If-Aroclors are spilled on the akin, the skin should be washed in the usual manner with aoap solutions. If accidental burns occur from contact with hot Aroclors, the burn should be treated the same as any ordinary burn. Aroclor adhering to the burned area need not be removed Immediately unless treatment of the burn demands It, In which case use soap and water or repeated washings with a vegetable oil. At ordinary temperatures Aroclors have not presented industrial toxicological problems. If Aroclore are used at elevated temperatures in open systems, methods must be designed to exhaust any vapors arising. Experimental work on animals indicates that the maximum safe concentrations of vapors in worteocoa is in the range of 1.0 to 2.0 milligram per cubic meter of air. This applies to all of the liquid Aroclors. 75 MWMWT0'' 001343 WATER PCB-SD0000025961 SILiM D1 i- z-oo , a-iO.-W) DKAULLI AiNU Mt.KKC.LL-1 1 JU^lU^S'-slo/lD Laboratory technique merely requlrea keeping the hands free of the liquid and handling it wider a wall ventilated hood, Loeiltxfd or spot ventilation together with general work room exhaust is recommsndtd for plant operations, Whan sampling tankcara, canvas gloves and safety glasses or goggles should bs worn, No spaelal clothing is required but the workera garments should bo laundered at least weekly and changed in eass Aroclor or Aroelor mixture is spilled on the clothes accidentally. If workmen are exposed to Aroclor vapors at relatively high levels# as may be the case when opening a heated capacitor Impregnating chamber# a respirator should be worn during these short intervale. , , Th many years of satisfactory and safe use of Area lore and thslr mixtures with chlorinated benzenes in the electrical industry for impregnating capacitors and filling transformers has dsoonstrated the industry's ability to handle these fluids without hazard to the workmen. It is a simple matter and in lino with good "housekeeping" and personal cleanliness to mrelti the suggested and required precautions In all cases. 76 A0M o 0OH Knnows WATER PCB-SD0000025962