Document v16wLYGMowprwgrnk9m2mJ0Y8
ELECTRONICS____ HYDRAULICS_____ HE AT TRANSFER_____ LUBRICATION NUCLEONICS____ SONICS_____ COOLANTS_____ DIELECTRICS:
Monsanto Specialized Fluids and new FluiDesign Service can help you benefit from
Conventional fluids (water, oil) impose well-known restrictions on engineer ing designs. Heat, radiation, fire hazard, shear, electrical requirements, extreme pressure, friction--all cause problems--limit you in design flexibility, in imaginative thinking, in new ideas.
Monsanto's specialized synthetic fluids--chemically tailored to minimize many design restrictions in power transmission, lubrication, heat transfer, insulation, cooling--make new and improved designs practical. Spawned by advances in specialized fluid properties and broadening of fluid functions-- a renaissance in engineering concepts is starting now. These specialized fluids open new design opportunities for your exploration.
Monsanto's new FluiDesign Service--established to help you meet your needs best from the capabilities of some thirty specialized fluids--can give you valuable guidance at the outset of your design exploration and engi neering planning. For example, the next two pages provide you with the FluiDesign Service Report, "Dielectric Fluids for New Electrical and Electronic Uses." Among the twelve fluids described, one or more may allow you to engineer your next design for better performance, less weight, smaller size, or lower cost.
o
0508965
" TOWOLDMON0048056 WATER PCB-00035275
From Monsanto FluiDesign Service...
DIELECTRIC FLUIDS FOR MEW ELECTRICAL
AMD ELECTROMIC USES
Monsanto can supply you with a scries of dielectric liquids that offer the optimum combination of proper ties for liquid cooling and insulation. Many of the fluids described below are now used commercially in capac itors, transformers, "miniaturized" electronic packages, cables, ampli fiers, solenoids, thermostats, com puters, and circuit breakers.
Examples:
A. In electrical equipment such as transformers, Monsanto's askareltype fluids offer a series of fireresistant dielectrics. These fluids make a firesafe liquid-fill insulation for equipment that then may be located in operating areas without special precaution or costly shielding.
B. As impregnants for premiumquality capacitors, high dielectric Monsanto fluids permit a substantial decrease in capacitor size---about 5060%--compared to oil-impregnated
Dietoclrlc Fluids
OS-59
Cootanol 35
Properties
Dielectric Strength, 25C, 60 cps, 0.1.................
Dielectric Constant, 25C, 1000 cps.................
Volume Resistivity, ohm-cm, 25C.....................
Power Factor, % 1000 cps, 25C.................
Viscosity, C$ --65F .................................. 100F .................................. 210F ..................................
Pour Point, F.........................
Boiling Point, F 760 mm. Hg.....................
Fire Point, F Cleveland Open Cup . . .
Thermal Conductivity
Blu/hr/ft/fta/F..............
Specific Gravity (?t25/25C.............................
Coefficient Thermal Expansion, per F . . . .
44KV 2.46 (10'cps) 6.7xl0> 0.006 (106cps) 1380 6.8 2.2 <-85 >700 435 0.077 0.88 0.00046
47 KV
....
.... ....
934 6.5 2.2 <-85 >600 430 0.079 0.89 0.00047
Coolanol 45
27KV 2.2 (106cps) 9xl0io 0.4 (106cps) 2400 12.2 3.95 <-85 >700 430 0.080 0.89 0.00048
Arodor 1221
35 KV 4.5
>5x101* <0.1
4.6 <1.8
34 527 349 0.067 1.18 0.00039
Arocior 1232
--
35KV 5.4
>5x10'* <0.1
6.9 <1.8
-32
554 460 0.063
>0 -*
O'
ion
1.26
0.00040
60-OMC-2766 Electronics, Week of November 14; Machine Design, November 24, 1960 and January 5, 1961.
..................
TOWOLDMON0048057
WATER PCB-00035276
capacitors. Because their dielectric constants arc closer to those from the capacitor paj>cr itself, they help achieve a more evenly distributed dielectric stress than is possible with mineral oil. C. Monsanto's coolant-dielectrics dissipate heat and operate liquidcooled power packs, magnetrons, traveling wave tubes, klystrons with precise temperature control. Liquid cooling with these dielectrics j>ermits miniaturization of electronic com ponents, conserves size and weight. These social synthetic fluids are
also lubricants, and the single fluid can double as the hydraulic-fluid
activator for tuning mechanisms as well as the coolant for the elec tronic unit.
This schematic circuit (at left) shows how Coolanol 45 liquid cools a klystron. Pumped around the collec tor, Coolanol 45 absorbs surface heat from the tube wall and carries it away for dissipation in the heat exchanger.
Check the fluids shown for applica tion in equipment you are using or developing. Monsanto can supply you with a dielectric fluid for vir tually any electrical or electronic application, can be most helpful in guiding you in the early design stages of equipment that will require a liquid dielectric.
A sample of the fluids shown will be sent to you for evaluation on request. Please specify the particular fluid that interests you and state the nature of the application so that pertinent details can be sent you. For further information on available fluids, request a copy of FluiDesign Service's FLUID DATA FILE.
Monunlo Chemical Companj Oifanlc Chemical! Diiiiieit FluiDeiijn Sereice, Dept Hiit Jt leuli (S. Miauurl
--
Aroelor 1242
Aroelor 1248
Aroelor 1254
Aroelor 1260
Biphenyl
HB-40
Santowox R
35KV 5.8
>5xl0> <0.1
35KV 5.6
>5xl0i2 <0.1
35KV 5.0
>5xl0n <0.1
35KV 5.0
>5x1012 <0.1
35KV 2.5
> 1x10*2 <0.1
35KV 2.65
>5xl0i <0.1
35KV 2.58
>lxl0i <0.1
17.2 45.3 46.4
2.5
3.2
6.14
75"
2 20 50 88
0.98
29" 3.9
156 -13 293
617 644 689 714 491 683 687
>610
>640
>662
698
255
385
460
0.058
0.057
0.054
0.051
0.076
0.072
0.063
1.38
1.45
1.54
1.62
0.984
1.002
0.955
0.00038
0.00039
0.00037
0.00037
0.00050
0.00041
0.00052
oducts Engineering, November 21 and December 26; Electrical Manufacturing, November and December, 1960.
r*-0
O'
o o
..............
TOWOLDMON0048058 WATER PCB-00035277