Document rxoNQX8evy6EnoOBYBKRDR1VG
REPORT OF RCRA COMPLIANCE EVALUATION INSPECTION
At
Pella Corporation - Pella Operations 102 Main St.
Pella, IA 50219 (641) 621 - 6695
EPA ID Number: IAD005278502
On
June 21, 2022
By
Eastern Research Group, Inc.
For
U.S ENVIRONMENTAL PROTECTION AGENCY Region 7
Enforcement and Compliance Assurance Division
1.0 INTRODUCTION
At the request of the Enforcement and Compliance Assurance Division/Chemical Branch/RCRA Section (ECAD/CB/RCRA) of the U.S. Environmental Protection Agency (EPA) Region 7, Eastern Research Group, Inc. (ERG) conducted a Resource Conservation and Recovery Act (RCRA) compliance evaluation inspection (CEI) at Pella Corporations - Pella Operations (PC) in Pella, Iowa on June 21, 2022. The CEI was conducted under the authority of Section 3007(a) of RCRA, as amended. Throughout the CEI, data and information were collected to determine compliance with the applicable regulatory and statutory requirements. The inspection report and attachments present the results of the CEI.
2.0 PARTICIPANTS
Pella Corporation - Pella Operations: Peter Dahlgren, Senior Environmental and Safety Engineer
EPA Representative, ERG: Janosh Wolters, Energy Engineer Anshul Paripati, Chemical Engineer
3.0 INSPECTION PRECEDURES
After arriving unannounced at PC at approximately 07:50, I performed a drive-by visual inspection of the facility and took a photograph before beginning the inspection and did not note any areas of concern. The facility's main entrance has a security check in location prior to entering. I introduced myself and signed into the visitor's log. The security team contacted Mr. Peter Dahlgren, Senior Environmental Engineer who greeted us at approximately 08:00 at the main entrance. I introduced myself and presented my inspector credentials to Mr. Dahlgren and explained my reason for being on site is to conduct a RCRA CEI. Mr. Dahlgren led us to a table within the corporate office to begin the opening conference at approximately 08:10. I initiated the opening conference with Mr. Dahlgren as PC's representative. I presented Mr. Dahlgren with my business card, as well as the business card of the EPA Task Order Contracting Officer Representative, Mr. Trevor Urban. Mr. Paripati explained he has not obtained a RCRA credential and was observing the inspection for training purposes. I then presented a copy of RCRA Section 3007(a), which contains EPA's inspection authority. I explained my need to collect accurate information and presented them with a copy of Title 18 U.S. Code, Sections 1001 and 1002. I then presented Mr. Dahlgren with a copy of the Notice Regarding Proprietary/Confidential Business Information Submitted to or Collected by EPA in Connection with Inspections and reviewed PC's confidentiality rights. I informed Mr. Dahlgren that I would provide a Confidentiality Notice at the end of this inspection.
The inspection consisted of a discussion of facility operations, waste generation and waste management, a review of waste management records, and a visual inspection of the waste generation and management areas. Mr. Dahlgren provided a facility layout (see Attachment 1) and explained facility operations and locations of hazardous waste generation and management.
During the visual inspection of the facility, Mr. Dahlgren guided us throughout the facility in order to conduct thorough evaluations of the facility's satellite accumulation areas (SAAs) and central accumulation area (CAA). At the time of the inspection, the facility was operating 22 SAAs and one CAA. The facility also handles universal waste lamps and batteries in one area on site as shown on the facility layout. The universal waste storage area was visually inspected. PC does not use parts washers on site. I conducted an in-depth visual inspection of the SAAs, the CAA, the universal waste storage area, used oil storage area, and all manufacturing areas.
Nine photographs were collected as inspection documentation and are shown in Attachments 2 and 3. Information collected during the inspection is documented on the EPA Inspection Checklist (see Attachment 4). I followed the inspection procedures discussed in the RCRA CEI Standard Operating Procedure (No. 2321.01D), unless noted differently. At the conclusion of the inspection, I provided Mr. Dahlgren with a Confidentiality Notice, Receipt for Documents and Samples, and Notice of Preliminary Findings which he signed as acknowledgement of receipt (see Attachments 5, 6, and 7 respectively). No confidentiality claims were made by PC. The following inspection documents and compliance assistance handouts were left with PC:
RCRA Section 3007(a) Title 18 U.S. Code, Sections 1001 and 1002
2
Notice Regarding Proprietary/Confidential Business Information Submitted to or Collected by EPA in Connection with Inspections
Confidentiality Notice (Facility copy) Receipt of Documents and Samples (Facility copy) NOPF (Facility Copy) Instructions for Responding to a NOPF Security Awareness Commercial Motor Vehicle Transportation Security Planning EPA E-Manifest Fact Sheet U.S. EPA Small Business Resources U.S. EPA Publication, Managing Your Hazardous Waste U.S. EPA Publication, Managing Used Oil-Advice for Small Businesses PowerPoint Presentation, 2013 Solvent Wipes Final Rule Pollution Engineering Article, 10 Common Questions for Waste Generators Iowa Department of Natural Resources (IDNR) Waste Exchange Folder and P2 Brochures IDNR Management of Fluorescent Lamps for Businesses Information Sheets IDNR Aerosol Can Disposal for Businesses Information Sheet University of Northern Iowa Waste Reduction Center Information Card Solvent-Contaminated Wipes Final Rule Summary Chart
4.0 FINDINGS AND OBSERVATIONS
Facility Information and Operations
PC began operating in 1925 and currently employs approximately 2,850 people. The facility operates on a five-day, two shift schedule. Occasionally, certain employees are offered to work overtime on a Saturday if manufacturing demands must be met. The facility has a building footprint of approximately 1.2 million square feet. PC operations consist of manufacturing windows and doors for customers. The primary raw materials used are lumber, steel, aluminum coils, paint, and solvents. The major manufacturing or processing operations that generate waste streams include painting and manufacturing windows and doors. The following waste streams are produced: rust remover waste, sulfuric acid, still bottoms, solid wood preservative, lacquer waste, liquid waste paint, solid waste paint, paint related materials, electrical discharge machining filters, immersion cleaner waste, burn ash waste, LabPak waste, ink and cleaning. In addition; solvent contaminated wipes, wastewater treatment sludge, saw dust, glass, oily rags, aerosol can residuals, used oil, universal wastes, scrap metal, and general trash.
4.2 RCRA Status
According to the Hazardous Waste Site Info Verification Report for Inspector (see Attachment 8), PC notified as a federal Large Quantity Generator (LQG) of D001, D002, D005, D006, D007, D008, D027, D035, D039, D040, F003, F005, F019, F027, F032 hazardous wastes. I asked Mr. Dahlgren to review the Hazardous Waste Site Info Verification Report for Inspector, which I provided prior to records review and visual inspection of the waste generation areas. Mr. Dahlgren stated the facility contact should be updated. Besides updating the facility contact, Mr.
3
Dahlgren stated the remaining information on the form was accurate to the best of his knowledge. After reviewing the records and walking through the facility, I determined that the facility is operating as a federal LQG of D001, D002, D005, D006, D007, D008, D035, D039, D040, D043, F003, F005, U019, and U220 hazardous wastes, a generator of used oil, and a small quantity handler (SQH) of universal waste. PC generates more than 1,000 kilograms of hazardous waste monthly based on a review of facility records, a visual inspection of process and waste management areas, and interviewing personnel. PC was previously inspected by EPA on April 18, 2017. The inspection led to a NOPF. The findings included: failure to have accumulation start dates visible for inspection on two hazardous waste accumulation containers, failure to close on hazardous waste accumulation container, failure to document annual RCRA training for an alternative emergency coordinator, and a failure to provide annual RCRA training for an emergency coordinator. I did not observe any repeat findings at the time of the inspection.
4.3 Facility Waste Streams and Management A Waste Stream and Waste Handling Table for PC is presented below. The table describes waste streams generated, generation process/rates, hazardous waste determinations, and on-site/off-site management. The rest of this page left blank intentionally.
4
WASTE
GENERATION HAZARDOUS WASTE ESTIMATED
ON-SITE
OFF-SITE
STREAM
PROCESS
DETERMINATION
GENERATION MANAGEMENT MANAGEMENT
#
RATE
1 Rust Remover Industrial cleaning D002, D006 (based on
1,848 pounds per 55-gallon containers Savannah Transport
(Waste profile station that cleans process knowledge and year
in SAAs before
Inc. in Topeka, KS
included in
maintenance tools knowledge of the product)
transferred to CAA (KS0000336891) to
Attachment 9) and facility
Rineco in Benton, AR
equipment
(ARD981057870) for
storage and transfer
2 Sulfuric Acid Battery waste
D002 (based on process Less than 20
55-gallon containers Savannah Transport
knowledge and knowledge gallons per year in SAAs before
Inc. in Topeka, KS
of the product)
transferred to CAA (KS0000336891) to
Rineco in Benton, AR
(ARD981057870) for
incineration
3 Still Bottoms
Distilling solvent D001, D007, D008, F003, 188,491 pounds 55-gallon containers Savannah Transport
(Waste profile (SDS of virgin
F005 (based on process per year
in SAAs before
Inc. in Topeka, KS
included in
solvent included in knowledge and knowledge
transferred to CAA (KS0000336891) to
Attachment 10) Attachment 11) of the product)
Rineco in Benton, AR
(ARD981057870) for
fuel blending
See Section 4.6 for more information on the facility's waste determination for this waste stream.
5 Solid Wood
Water protection D001 (based on process 35,000 pounds per 55-gallon containers Savannah Transport
Preservative and and bug protection knowledge and knowledge year
in SAAs before
Inc. in Topeka, KS
Mill Sludge
solvent sprayed of the product)
transferred to CAA (KS0000336891) to
(Waste profiles onto wood
Rineco in Benton, AR
included in
(ARD981057870) for
Attachment 12
fuel blending
and Attachment
13)
5
WASTE
GENERATION HAZARDOUS WASTE ESTIMATED
ON-SITE
OFF-SITE
STREAM
PROCESS
DETERMINATION
GENERATION MANAGEMENT MANAGEMENT
#
RATE
6 Waste Lacquer Cleaning
D001, D035, F003, F005 102,112 pounds 55-gallon containers Savannah Transport
(Waste profile equipment with (based on process
per year
in SAAs before
Inc. in Topeka, KS
included in
wipes/wiping
knowledge and knowledge
transferred to CAA (KS0000336891) to
Attachment 14) down paint booth of the product)
Rineco in Benton, AR
components
(ARD981057870) for
fuel blending
7 Liquid Waste Excess paint Paint (Waste profile in Attachment 15)
D001, D005, D007, F003, F005 (based on process knowledge and knowledge of the product)
21,919 pounds per year
55-gallon containers in SAAs before transferred to CAA
Savannah Transport Inc. in Topeka, KS (KS0000336891) to Rineco in Benton, AR (ARD981057870) for fuel blending
See Section 4.6 for more information on the facility's waste determination for this waste stream.
8 Solid Waste
Dried paint booth D001, D005, D007, F003, 3,659 pounds per 55-gallon containers Savannah Transport
Paint (Waste
filters, could
F005 (based on process year
in SAAs before
Inc. in Topeka, KS
profile included include rags
knowledge and knowledge
transferred to CAA (KS0000336891) to
in Attachment
of the product)
Rineco in Benton, AR
16)
(ARD981057870) for
energy recovery
See Section 4.6 for more information on the facility's waste determination for this waste stream.
9 Solid Paint
PPE and dried
Related
filters
Materials (Waste
profile included
in Attachment
17)
D005, D007 (based on process knowledge and knowledge of the product)
191,739 pounds per year
55-gallon containers in SAAs before transferred to CAA
Savannah Transport Inc. in Topeka, KS (KS0000336891) to Rineco in Benton, AR (ARD981057870) for energy recovery
See Section 4.6 for more information on the facility's waste determination for this waste stream.
6
WASTE
GENERATION HAZARDOUS WASTE ESTIMATED
STREAM
PROCESS
DETERMINATION
GENERATION
#
RATE
10 Electrical
Enclosed spark D007 (based on process 3,620 pounds per
Discharge
machining
knowledge and knowledge year
Machining
operation
of the product)
(EDM) Filters
(Waste profile
included in
Attachment 18)
11 Immersion
Cleaning
D039, D040 (based on
162 pounds
Cleaner (Waste maintenance parts process knowledge and
profile included for facility
knowledge of the product)
in Attachment equipment
(SDS included in
19)
Attachment 20)
See Section 4.8 for the facility's waste determination.
12 Burn Ash Waste Paint from
D007 (based on process 6,315 pounds per
(Waste profile automated hangers knowledge and knowledge year
included in
that is burned off of the product)
Attachment 21) hangers in oven
See Section 4.7 for the facility's waste determination.
ON-SITE MANAGEMENT
OFF-SITE MANAGEMENT
55-gallon containers in SAAs before transferred to CAA
Savannah Transport Inc. in Topeka, KS (KS0000336891) to Rineco in Benton, AR (ARD981057870) for incineration
Inside 6-gallon parts washer
Safety Kleen Systems Inc. in Denton, TX (TXR000081205) to Pioneer Tank Lines (MND044176113) in Afton, Minnesota to Safety Kleen Systems Inc. (ILD980613913) to Dolton, IL for incineration
55-gallon containers in SAA before transferred to CAA
Savannah Transport Inc. in Topeka, KS (KS0000336891) to Rineco in Benton, AR (ARD981057870) for energy recovery
7
WASTE STREAM # 13 LabPak
GENERATION PROCESS
QC laboratory testing
HAZARDOUS WASTE DETERMINATION
D001, D002, D003, D007, D018, U019, U220 (based on process knowledge and knowledge of the product)
ESTIMATED GENERATION RATE 48 pounds per year
ON-SITE MANAGEMENT
55-gallon container in CAA
OFF-SITE MANAGEMENT
Clean Harbors Environmental Services (MAD039322250) in Norwell, MA to Clean Harbors Aragonite LLC (UTD981552177) in Grantsville, UT for incineration
14 Barcode
Cleaning barcode D001, D007, D035, D043 329 pounds per
Cleaning Waste labeler during
(based on process
year
(Waste profile facility
knowledge and knowledge
included in
maintenance
of the product) (SDS
Attachment 22)
included in Attachment
23)
55-gallon containers in SAAs before transferred to CAA
Savannah Transport Inc. in Topeka, KS (KS0000336891) to Rineco in Benton, AR (ARD981057870) for fuel blending
See Section 4.10 for the facility's waste determination.
15 Solvent Contaminated Wipes
Wipes used for wiping off products
Excluded per 40 CFR 261.4(a)(26) - (based on process knowledge and knowledge of the product)
6,000 pounds per year
See Section 4.9 for the facility's waste determination.
5-gallon containers
MidWest Sanitation in Des Moines, IA to South Central Iowa Solid Waste Agency Landfill in Tracey, IA for landfill
8
WASTE STREAM # 16 Aerosol Can Residuals
17 Oily Rags
18 Used Oil
GENERATION PROCESS Puncturing RCRA empty containers
Wiping off oils and greases from maintenance tools
Facility maintenance of equipment
HAZARDOUS WASTE DETERMINATION
D001, D005, D007, F003, F005 (based on process knowledge and knowledge of the product)
ESTIMATED GENERATION RATE Less 5 gallons per year
Nonhazardous (based on process knowledge and knowledge of the product)
One 55-gallon container picked up weekly
Exempted (managed as used oil per 40 CFR 279)
One 55-gallo container every two months
ON-SITE MANAGEMENT
OFF-SITE MANAGEMENT
55-gallon container is added to liquid waste paint container in CAA
55-gallon container
55-gallon containers
Savannah Transport Inc. in Topeka, KS (KS0000336891) to Rineco in Benton, AR (ARD981057870) for fuel blending
Village Cleaners in Pella, IA for laundering (Invoice included in Attachment 24) Safety-Kleen Systems Inc. (MAD039322250) in Norwell, MA for recycling
19 Used Oil Filters Punctured and hot Exempted (managed as drained then added used oil per 40 CFR 279) to scrap metal
20 Scrap Metal
Facility operations
Excluded (based on management and process knowledge) recycled as scrap metal
Estimated that one 55-gallon container would be filled per year if not added to scrap metal container 40-yard container picked up once or twice a year
40-yard container 40-yard container
Rosenman's Inc. Steel Service Center in Ottumwa, IA for recycling
Rosenman's Inc. Steel Service Center in Ottumwa, IA for recycling (Invoice included in Attachment 25)
9
WASTE
GENERATION
STREAM
PROCESS
#
21 Universal Waste Facility
Lamps
maintenance
HAZARDOUS WASTE DETERMINATION
Exempted (managed as universal waste per 40 CFR 273)
ESTIMATED GENERATION RATE 600 - 800 lamps per year
ON-SITE MANAGEMENT
4-foot containers and 8-foot containers
OFF-SITE MANAGEMENT
A-TEC Recycling Inc. in Des Moines, IA (IA0000109827) for recycling
22 Universal Waste Facility
Exempted (managed as Two 55-gallon
55-gallon container Savannah Transport
Batteries
maintenance
universal waste per 40
containers every
Inc. in Topeka, KS
CFR 273)
six months
(KS0000336891) to
Rineco in Benton, AR
(ARD981057870) for
recycling
23 Wastewater
Facility
Nonhazardous (based on 9,000 pounds
55-gallon containers MidWest Sanitation in
Treatment
wastewater
process knowledge,
every three months
Des Moines, IA to
Sludge (Special treatment plant
knowledge of the product,
South Central Iowa
Waste
filter cake sludge and analytical testing)
Solid Waste Agency
Authorization
(Analytical report included
Landfill in Tracey, IA
(SWA) included
in Attachment 27)
for landfill
in Attachment
26)
24 Wastewater
Washing off parts Nonhazardous (based on Discharge 50,000 Discharged to
POTW in Pella, IA for
prior to painting process knowledge and
gallons per day
Publicly Owned
treatment
knowledge of the product)
Treatment Works
(POTW) in Pella, IA
25 Broken Glass
Facility operations and glass breaking from windows
Nonhazardous (based on process knowledge and knowledge of the product)
40-yard container picked up weekly
40-yard container
MidWest Sanitation in Des Moines, IA to South Central Iowa Solid Waste Agency Landfill in Tracey, IA for landfill
10
WASTE STREAM # 26 Saw Dust
27 General Trash
GENERATION PROCESS
Cutting of lumber
HAZARDOUS WASTE DETERMINATION
Nonhazardous (based on process knowledge and knowledge of the product)
ESTIMATED GENERATION RATE Unknown - not tracked
Facility operations
Nonhazardous (based on process knowledge and knowledge of the product)
Two 40-yard container picked up weekly
Remainder of page left intentionally blank.
ON-SITE MANAGEMENT
OFF-SITE MANAGEMENT
Conveyed directly over to neighboring business (American Wood Fibers)
40-yard container
Conveyed to American Wood Fibers to be remanufactured into various wood products
MidWest Sanitation in Des Moines, IA to South Central Iowa Solid Waste Agency Landfill in Tracey, IA for landfill
11
Less-Than-90-Day Hazardous Waste Accumulation Area
PC has one Less-Than-90-Day CAA on site, which is located outside of Area III as labeled on the facility layout (see Attachment 1). The CAA is a standalone structure that is used solely for storing wastes. I visually inspected the CAA and observed a total of six 55-gallon containers of paint related waste. In addition, I observed six 55-gallon containers of still bottoms, three 55gallon containers wood preservative waste, one 55-gallon container of burn ash waste, one 55gallon container of lacquer waste, and one 55-gallon container of waste paint (see Attachment 3, Photo 9). The facility managed all these containers as hazardous waste. All hazardous waste containers were closed, in good condition, labeled with the indication of the nature of the hazard, labeled with an accumulation start date, and labeled with the words "Hazardous Waste". The oldest accumulation start date observed was "6/2/2022" on a 55-gallon container of waste paint. June 2, 2022 is within 90 days from the time of the inspection. I observed adequate aisle space to allow for container inspections and access in the event of a spill. Mr. Dahlgren stated that if the facility were to have a spill, the floor inside the building would act as the secondary containment until the spill could be cleaned up. In addition, any incompatible wastes are stored on opposite sides of the building and are stored on secondary containment pallets. I observed spill control equipment, and related safety equipment within close proximity of the CAA. Operators handling hazardous waste are trained to use their twoway radio system in case of emergencies. I asked Mr. Dahlgren if the facility inspected the CAA. Mr. Dahlgren stated the facility inspected the CAA at least weekly and had weekly inspection logs.
During records review, Mr. Dahlgren provided inspection logs for the CAA. I reviewed the logs and determined the facility was adequately performing weekly inspections of the CAA. An example of a CAA log is provided in Attachment 28.
I did not note any issues or findings at the CAA during the inspection. However, I did note one finding regarding a previous CAA that was no longer in use. The CAA was previously located where SAA 15 was observed. See the end of Section 4.5 for more information on this finding.
Satellite Accumulation Areas
I observed 22 satellite areas during the visual inspection. The table on the next page shows the SAA name or location, waste type, volume of waste observed, and container type.
12
SAA #
1 2
3
4 5
6
7
8
9 10
11
12
13 14 15
16 17
18 19 20 21
22
SAA Name or Location
Waste Type
Area 1 Solvent Room Lacquer Waste
Area 1 Wood Treat Wood Preserver
Waste
Area 2 Maintenance Barcode Cleaning
Shop
Waste
Area 2 Lacquer Booth Lacquer Waste
Area 2 Southern Wall Wood Preserver
Waste
Area 3 Maroon Cell Wood Preserver
Waste
Area 3 Blue Cell Wood Preserver
Waste
Area 3 RTP Cell Wood Preserver
Waste
Area 3 South Door Lacquer Waste
Battery Charging
Sulfuric Acid
Station
Area 3 Wood Treat Wood Preserver
Area
Waste
Maintenance Paint Lacquer Waste
Booth
Maintenance Shop Rust Remover
EDM Operations
EDM Filters
Solvent Still
Solvent Wipes
(Butyl Acetate)
Vertical Paint Line Solid Waste Paint
Vertical Paint Line Solid Paint Related
Materials
Vertical Paint Line Lacquer Waste
Burn Off Oven
Burn Ash
Horizontal Paint Line Waste Lacquer
Horizontal Paint Line Solid Paint Related
Materials
Solvent Still
Still Bottoms
Volume of Waste
30 gallons 20 gallons
5 gallons
20 gallons 25 gallons
30 gallons
35 gallons
25 gallons
20 gallons 25 gallons
20 gallons
35 gallons
20 gallons 15 gallons 2 gallons
30 gallons 30 gallons
25 gallons 25 gallons 20 gallons 30 gallons
0 gallons
Container Type
55-gallon container 55-gallon container
55-gallon container
55-gallon container 55-gallon container
55-gallon container
55-gallon container
55-gallon container
55-gallon container 55-gallon container
55-gallon container
55-gallon container
55-gallon container 55-gallon container 5-gallon container
55-gallon container 55-gallon container
55-gallon container 55-gallon container 55-gallon container 55-gallon container
55-gallon container
During the visual inspection, I observed the 22 SAAs. An example photograph was taken for how a majority of the SAAs were observed during the visual inspection (see Attachment 3, Photo 3). I observed a 55-gallon container of tert butyl acetate waste being accumulated in SAA 20. The SAA 20 was located in the horizontal paint line. Based on how the facility manages the horizontal paint line room, they did not allow any devices that were not intrinsically safe inside the building. Therefore, I was unable to take a photograph of SAA 21. I visually inspected the 55-gallon container in SAA 21 and observed a "Flammable Liquid" placard but did not observe the words "Hazardous Waste" on the container. I asked Mr. Dahlgren why the 55-gallon
13
container was not labeled with the words "Hazardous Waste". Mr. Dahlgren stated the container should have been labeled with the words "Hazardous Waste" and immediately added a labeled with the words "Hazardous Waste" onto the container. Upon initial inspection of the 55-gallon container observed in SAA 21, I did not observe the container to be labeled with the words "Hazardous Waste", therefore, the following finding was left with the facility:
NOPF 1 - Failure to have the words "Hazardous Waste" on a SAA container. [40 CFR 262.15(a)(5)(i)].
The remainder of SAA containers were labeled with the words "Hazardous Waste". During the visual inspection, I observed two SAA 55-gallon containers located directly next to each other in the vertical paint line area. Based on how the facility manages the vertical paint line room, they did not allow any devices that were not intrinsically safe inside the building. Therefore, I was unable to take a photograph of SAA 17 and SAA 18. However, the 55-gallon container in SAA 17 was placed within two feet of the 55-gallon container in SAA 18. The 55-gallon container in SAA 17 was accumulating approximately 30 gallons of toxic paint related material (PPE, paint booth filters) and was being managed as a D005, and D007 solid hazardous waste. The 55-gallon container in SAA 18 was accumulating approximately 20-25 gallons of Lacquer waste and was being managed as a D001, D035, F003, and F005 hazardous waste. I asked Mr. Dahlgren when these containers are moved out of the SAA locations. Mr. Dahlgren stated when a SAA container is full, it is moved within 72-hours to the CAA. I asked Mr. Dahlgren how the facility ensures no more than 55-gallons of hazardous waste is accumulated in this location. Mr. Dahlgren stated because the SAA containers were not accumulating the same type of hazardous waste, each container is allowed to accumulate no greater than 55-gallons. I explained to Mr. Dahlgren that 40 CFR 262.15(a) states "A generator may accumulate as much as 55 gallons of non-acute hazardous waste and/or either one quart of liquid acute hazardous waste listed in 261.31 or 261.33(e) of this chapter or 1 kg (2.2 lbs) of solid acute hazardous waste listed in 261.31 or 261.33(e) of this chapter in containers at or near any point of generation where wastes initially accumulate which is under the control of the operator of the process generating the waste, without a permit or interim status and without complying with the requirements of parts 124, 264 through 267, and 270 of this chapter, provided that all of the conditions for exemption in this section are met." Based on Mr. Dahlgren's statements, the facility appears to potentially accumulate more than 55-gallons of hazardous waste in what could potentially be considered one SAA. Therefore, the following finding was left with the facility:
NOPF 2 - Failure to accumulate no more than 55-gallons of hazardous waste in one SAA. [40 CFR 262.15(a)].
Despite the issues discussed above, all SAA containers were in good condition, closed, labeled with the indication of the nature of the hazard, and labeled with the words "Hazardous Waste" (with the exception of the 55-gallon container in SAA 21).
During the visual inspection of SAA 15, I observed the facility layout showed a "90-day Storage" area labeled as shown on Attachment 1. I asked Mr. Dahlgren if this area was a CAA. Mr. Dahlgren stated to the best of his knowledge, it is not currently managed as a CAA. I asked
14
Mr. Dahlgren when this area stopped being managed as a CAA. Mr. Dahlgren was unsure of when PC stopped using this CAA. I asked Mr. Dahlgren if the facility followed the requirements per 40 CFR 262.17(a)(8)(i)(a) and placed a notice in the operating record within 30 days after closure identifying the location of the unit (CAA). Mr. Dahlgren stated he did not know of this requirement. In addition, during records review, Mr. Dahlgren was unable to locate any notice that was placed in PC's operating record. Therefore, the following finding was left with the facility:
NOPF 3 - Failure to place a notice in the operating record within 30 days of closure identifying the location of the unit within the facility. [40 CFR 262.17(a)(8)(i)(a)].
I reviewed the management of the SAAs, and no additional issues or findings were noted.
Painting Operations/Distillation Column
The facility operates a horizontal and vertical paint line on site. The horizontal paint line refers to products that are painting horizontally. The vertical paint line refers to products that are painted vertically. Both paint lines are automated, and the facility uses a conveyor system with hangers to hang products that are painted.
Mr. Dahlgren explained that the facility flushes the automated paint lines as needed. The automated paint lines are hard pipe connected to a 500-gallon solvent tank. The 500-gallon solvent tank holds a mixture of reclaimed and virgin solvent of tert-butyl acetate. As lines are flushed, the solvent is hard piped back to the distillation unit. The purged solvent is first accumulated in a 415 gallon "dirty" solvent tank that is connected to the distillation unit. The distillation unit runs a batch process of approximately 100 gallons per batch. I visually inspected all hard piping lines from the automated paint lines back to entering the 415 gallon "dirty" solvent tank. During the visual inspection, Mr. Mark Bender, Pretreat Technician explained the distillation unit process. I asked Mr. Bender if the facility ever adds containers of purged solvent into the distillation unit or the "dirty" solvent tank. Mr. Bender stated the only way purged solvent can enter the distillation unit is from the hard piping that is connected to the paint lines that enter the 415 gallon "dirty" solvent tank. I asked Mr. Bender approximately how often the distillation unit is operating. Mr. Bender stated the distillation unit is almost continuously running during operating hours. The facility manages the "dirty" solvent sent for recycling under the closed loop exemption per 40 CFR 261.4(a)(8).
I asked Mr. Bender how often virgin solvent is purchased and how it is added to the process. Mr. Bender explained PC receives 300-500 gallons of virgin solvent weekly that is placed into a 500gallon virgin solvent tank that is located in the same area as the distillation unit. Mr. Bender explained the virgin solvent is added to the 500-gallon reclaimed tank that is connected to the distillation unit. Mr. Bender stated the distillation unit cannot reclaim enough solvent fast enough. As a result, PC is forced to add virgin solvent to the reclaimed tank weekly. Mr. Bender was not able to state the efficiency of the distillation unit but was aware that it was at least 75-80
15
percent efficient. Mr. Bender also explained that still bottoms are generated as a result of running the distillation unit. Mr. Bender explained that still bottoms are accumulated in a 55-gallon container directly under the distillation unit. At the time of the inspection, I did not observe a 55gallon container of still bottoms underneath the distillation unit. I asked Mr. Bender where the still bottoms were being accumulated. Mr. Bender stated the still bottoms drum was being moved to the CAA during the time of our visual inspection of the distillation unit. Based on how the facility manages the distillation unit room, they did not allow any devices that were not intrinsically safe inside the building. Therefore, I was unable to take a photograph of distillation unit.
During records review, I observed the facility managing the still bottoms waste as a D001, D007, D008, F003, and F005 hazardous waste. I asked Mr. Dahlgren why the facility managed the still bottoms waste with the D007 and D008 waste codes. Mr. Dahlgren stated he believed the facility did this out of an abundance of caution but does not believe the still bottoms waste to be hazardous for D007 (chromium) or D008 (lead). The SDS for the solvent-based paint used on site is provided in Attachment 29. The SDS for the solvent used to flush paint lines is provided in Attachment 11. These SDSs both indicate that it appears the waste would not be hazardous for either D007 or D008. However, the waste profile for this waste stream is provided in Attachment 10 and indicates the waste is hazardous for D007 and D008.
In addition, the facility manages solid paint waste generated from paint booth equipment cleaning operations with the following EPA waste codes: D001, D005, D007, F003, and F005. Based on how painting operations occur on site and the types of paint used, it does not appear based on a records review that the paint waste would need to include D005 or D007. Mr. Dahlgren stated he believes the waste stream most likely does not need these waste codes, but the facility added them out of an abundance of caution. Solid paint related debris (PPE) was managed as a D005 and D007 hazardous waste per the waste profile in Attachment 16. Mr. Dahlgren stated the facility generates this waste by PPE waste for members that work in the painting line areas. Mr. Dahlgren stated the facility manages this waste with the hazardous waste codes out of an abundance of caution.
The facility manages excess paint waste with the following waste codes: D001, D005, D007, F003, and F005. I asked Mr. Dahlgren how this waste is generated. Mr. Dahlgren sated this waste is generated when excess unused waste paint from a painting operation is containerized into 55gallon containers. I asked Mr. Dahlgren if the paint was in contact with spent solvent. Mr. Dahlgren stated the excess paint would only be product paint that was waste because it was excess in the paint lines after a painting operation. The waste profile for this waste stream is provided in Attachment 15. The SDS for solvent-based paint used on site is provided in Attachment 29. I explained that based on how he described the waste to be generated and the SDSs reviewed, it appears the facility does not need to manage the waste as an F003 and F005 hazardous waste because it is not a spent solvent waste. Mr. Dahlgren stated he believes the facility manages the waste with all the EPA waste codes listed above out of an abundance of caution. Upon further
16
EPA review, a finding may be added for inadequate waste determinations. The facility appeared to be overclassifying multiple waste streams.
During painting operations, the facility uses a mineral spirits mixture which is referred to as lacquer in this report and at the facility. This lacquer is used to clean up dried paint off equipment or sprayed products. Mr. Dahlgren explained the facility uses rags during this process and manages these rags as a D001, D035, F003, and F005 hazardous waste. The waste profile is provided in Attachment 14. I observed lacquer waste in five SAAs throughout the facility.
Lastly, Mr. Dahlgren stated the facility does conduct smaller automated paint operations that use a water-based paint. These painting operations did not include the need of any hazardous solvents for cleaning. The SDS is provided in Attachment 30 as an example of water-based paints used on site.
I did not note any additional issues or concerns with the management and operation of painting operations on site.
Burn Off Oven
During the visual inspection, Mr. Dahlgren explained that hangers used to hold products conveyed through the automated paint lines accumulate dried paint after being run through the automated paint lines multiple times. Mr. Dahlgren stated the hangers are then placed into an oven located near SAA 19 as labeled on the facility layout (see Attachment 1). The dried paint drops to the floor of the oven which is then swept and put into a 55-gallon container in SAA 19. Mr. Dahlgren stated the paint is completely dried before entering the oven and has not come into contact with any solvents or other materials besides excess overspray from automated paint guns. At the time of the inspection, Mr. Dahlgren stated the facility was managing this ash waste as a D007 hazardous waste. The SDS for the solvent-based paint used in the painting operations is provided in Attachment 29. Mr. Dahlgren stated that to the best of his knowledge, this is the only solvent-based paint the facility was currently using. Based on this SDS of the paint and that the paint is completely dried prior to being burned, it appears the facility is managing a nonhazardous waste as a D007 hazardous waste. I explained to Mr. Dahlgren that the waste did not appear to be D007 hazardous waste. Mr. Dahlgren stated he did not believe the waste to be a D007 hazardous waste. He believed the facility was managing this waste as a hazardous waste out of an abundance of caution. I did not observe any additional issues or concerns with the management and operation of the burn off oven.
Immersion Cleaner
During the visual inspection, I observed an immersion cleaner in the maintenance shop as labeled on the facility layout (Attachment 1). The immersion cleaner appeared to be in good condition (see Attachment 3, Photo 7). Mr. Dahlgren explained the immersion cleaner is used to clean small maintenance tools or parts as needed. I asked Mr. Dahlgren what type of solution is
17
used in the immersion cleaner. During records review, Mr. Dahlgren provided the SDS for the immersion cleaner which is provided in Attachment 20. I reviewed the SDS and waste profile for the immersion cleaner (see Attachment 19). In addition, while reviewing manifests, I observed a manifest that included the shipment of immersion cleaner. The manifest observed is provided in Attachment 31. At the time of the inspection, PC was managing this waste as a D039 and D040 hazardous waste. I asked Mr. Dahlgren why the facility was managing this waste as a D039 and D040 hazardous waste. Mr. Dahlgren stated the facility was instructed by Safety Kleen, the company who services the immersion cleaner would not service the immersion cleaner waste unless it was managed as D039 and D040 hazardous waste. During the inspection, I did not observe anything on site that would generate a D039 or D040 hazardous waste. I explained to Mr. Dahlgren that based on the SDS, it appears the waste generated from this operation would be nonhazardous unless other hazardous materials are comingled with the immersion cleaner. Mr. Dahlgren stated the immersion cleaner waste would not become comingled with any hazardous materials based on the facility's use of the immersion cleaner. I did not observe any additional issues or concerns with the management and operation of the immersion cleaner.
Solvent Contaminated Wipes
Mr. Dahlgren stated the facility generated solvent contaminated wipes on site. The facility purchases disposal rags that are used throughout the facility. Wipes are usually used to clean off final products to remove imperfections. Mr. Dahlgren stated the facility would use tert butyl acetate for these cleaning operations. Mr. Dahlgren stated the wipes do not contain free liquids when entering the 5-gallon containers that accumulate solvent contaminated wipes throughout the facility (see Attachment 3, Photo 2). Mr. Dahlgren stated rags are added to general trash containers at least once every 180 days. I asked Mr. Dahlgren how the facility ensures wipes are removed from the 5-gallon accumulation containers and added to general trash at least once every 180 days. During records review, Mr. Dahlgren provided the facility's SOP for the management of solvent contaminated wipes which is included in Attachment 32. I explained to Mr. Dahlgren that the state of Iowa does not allow for any hazardous waste to be disposed of at a landfill. Mr. Dahlgren stated his coworkers and himself need to address the issue of potentially sending a federally exempted hazardous waste to a landfill in the state of Iowa. I thoroughly reviewed the requirements set forth in 40 CFR 261.4(b)(18) and documented the facility's compliance in the EPA Inspection Checklist (see Attachment 4). I did not observe any issues or concerns with the management and generation of solvent contaminated wipes on site.
Barcode Cleaning Waste
During the visual inspection, Mr. Dahlgren explained the facility generates ink and cleaning solution waste when cleaning off barcode scanners on site. The waste profile used for this waste is provided in Attachment 22. The SDS is included in Attachment 23. The facility was managing this waste as a D001, D007, D035, and D043 hazardous waste. I asked Mr. Dahlgren how this waste is generated. Mr. Dahlgren stated the barcodes are wiped with a disposable wipe and excess ink comes off. I asked Mr. Dahlgren why the waste was managed with the D007 and
18
D043 waste codes. Mr. Dahlgren stated he was unsure. I explained to Mr. Dahlgren that based on a review of the SDS and how the waste is generated, it does not appear to be a D007 or D043 hazardous waste. Upon further EPA review, a finding may be added for an inadequate waste determination. I did not observe any issues or concerns with the management and generation of barcode cleaning waste on site.
Aerosol Can Residual Waste
During the visual inspection, I observed one 55-gallon container inside the facility's CAA that accumulated aerosol can residual waste. The facility was managing this waste as a D001, D005, D007, F003, F005 hazardous waste. Mr. Dahlgren explained the facility uses aerosol cans until they are RCRA empty but still punctures the cans out of an abundance of caution. The waste is eventually comingled with liquid paint waste and shipped off site at least once per year. I did not observe any issues or concerns with the management and generation of aerosol can residual waste on site.
Universal Waste Accumulation Area
PC manages universal waste lamps directly inside the eastern entrance door to Area IV as labeled on the facility layout (see Attachment 1). I observed two 4-foot containers and one 8-foot containers of universal waste lamps (see Attachment 3, Photo 5). All three containers were labeled "Universal Waste Lamps". The earliest accumulation start observed was "3/17/2022" on the 4-foot container of universal waste lamps. In addition, PC manages universal waste batteries next to the facility's CAA as labeled on the facility layout (see Attachment 1). At the time of the inspection, I did not visually observe a container accumulating universal waste batteries on site. Mr. Dahlgren stated a 55-gallon container is placed next to the CAA which accumulates universal waste batteries as needed and is picked up by the same hazardous waste vendor PC uses. Mr. Dahlgren estimated approximately two 55-gallon containers are shipped off each year, approximately every six months. Mr. Dahlgren believed a shipment had just recently occurred.
I reviewed the management of all universal waste storage areas throughout the facility and no issues or findings were noted.
Wastewater
PC generates wastewater waste during pretreatments for products to be painted. PC has an onsite wastewater treatment plant (WWTP). Mr. Dahlgren explained the facility manages filter cake waste in a supersack that has a volume of approximately 74 cubic feet (see Attachment 3, Photo 8). Mr. Dahlgren stated PC has conducted analytical sampling to manage the filter cake waste from the on-site WWTP as a nonhazardous waste. The filter cake sludge is not generated from processes such as chromating, phosphating, metal coloring, and/or immersion plating. Therefore, it does not appear the F019 waste code would apply to this waste stream. The analytical study was conducted to allow PC to send filter cake off site under a SWA. The SWA is included in Attachment 26. The analytical report is included in Attachment 27. Mr. Dahlgren
19
stated PC had an agreement with the local POTW but could not provide me with a copy of the agreement at the time of the inspection. I asked Mr. Dahlgren what type of pretreatment solutions are used during pretreatment cleaning operations. Mr. Dahlgren stated PC uses a generic pretreatment cleaner, an aluminum adhesion solution to allow paint to better adhere to products. In addition, an aluminum coating is used on products. The SDS for the generic cleaner, aluminum adhesion solution, and aluminum coating are provided in Attachment's 33, 34, and 35, respectively. I did not note any issues or findings regarding the management of wastewater or WWTP filter cake during the visual inspection.
Used Oil
At the time of the inspection, I did observe used oil being accumulated in 55-gallon containers (see Attachment 3, Photo 6). The used oil container was closed, in good condition, labeled "Used Oil". Mr. Dahlgren explained that facility maintenance of equipment generates used oil. Mr. Dahlgren stated approximately one 55-gallon container is generated every two months. The used oil is hauled off site by Safety-Kleen Systems Inc. (MAD039322250) in Norwell, MA for recycling. Mr. Dahlgren stated used oil filters are punctured and hot drained before being added to scrap metal containers. An example of an invoice for used oil picked up is provided in Attachment 36.
I did not note any issues or findings regarding used oil management during the visual inspection.
Other Regulatory Requirements
Preparedness, Prevention, and Emergency Requirements - Safety and emergency equipment were present and in satisfactory condition in areas throughout the facility, including the hazardous waste CAA and SAAs (as noted in Section 4.4 and 4.5 of this report). Appropriate arrangements and coordination were made with necessary State and local emergency agencies.
I reviewed the preparedness, prevention, and emergency requirements and no issues or findings were noted.
Contingency Planning Requirements - The contingency plan (see Attachment 37) was in a binder and was reviewed while on site. The contingency plan included a complete emergency evacuation plan, a list of emergency response equipment and describes their capabilities. The plan also included emergency response procedures, emergency coordinators and contact information. In addition, the facility had a preparation quick reference guide that was also reviewed while on site. The quick reference guide is provided in Attachment 38. The contingency plan and quick reference guide were most recently revised on February 27, 2018.
I continued reviewing the contingency plan and noted the facility submitted the contingency plan to local emergency response agencies including the local police department, fire department, and hospital. I reviewed the entire RCRA contingency plan and no issues or findings were noted.
20
Personnel Training Requirements - Personnel are to be trained to perform hazardous waste duties, and new employees are to be trained within 6 months of start. The training, at a minimum, must be designed to ensure personnel at PC are able to manage hazardous waste relevant to the positions in which they are employed and respond effectively to emergencies by familiarizing them with emergency procedures, emergency equipment, and emergency systems, including:
1. Procedures for using, inspecting, repairing, and replacing facility emergency equipment 2. Communications and alarm systems 3. Response to fires or explosions
Upon reviewing the hazardous waste training employees of PC receive, I determined the training to be sufficient. Mr. Dahlgren stated annual refresher trainings are tracked via attendance sheets. Mr. Dahlgren showed me the attendance sheets doing records review. In addition, employees complete a short quiz after the training is completed. I reviewed all employees who manage hazardous waste and emergency coordinators to ensure all personnel receive an annual hazardous waste refresher training. I determined all emergency coordinators and employees who require annual refresher training were up to date on their trainings. Examples of quizzes are provided in Attachment 39.
I reviewed the personnel training requirements, and no findings were noted.
Manifest and Land Disposal Restriction (LDR) Requirements - PC maintained records of manifests on site at the time of inspection dating back three years. PC generated approximately 120 manifests over the last three years. I reviewed all 120 hazardous waste manifests. A manifest of immersion cleaner and a LabPak shipment and corresponding LDR forms are provided in Attachment 31 and 40, respectively as examples.
I observed no additional issues or findings during this inspection. However, further EPA review may add findings.
5.0 SUMMARY OF FINDINGS
Upon initial inspection of the 55-gallon container observed in SAA 21, I did not observe the container to be labeled with the words "Hazardous Waste", therefore, the following finding was left with the facility:
NOPF 1 - Failure to have the words "Hazardous Waste" on a SAA container. [40 CFR 262.15(a)(5)(i)].
I observed two SAA 55-gallon containers located directly next to each other in the vertical paint line area. Based on Mr. Dahlgren's statements, the facility appears to potentially accumulate more than 55-gallons of hazardous waste in what could potentially be considered one SAA. Therefore, the following finding was left with the facility:
21
NOPF 2 - Failure to accumulate no more than 55-gallons of hazardous waste in one SAA. [40 CFR 262.15(a)].
During records review, Mr. Dahlgren was unable to locate any notice that was placed in PC's operating record for the closure of a previously used CAA. Therefore, the following finding was left with the facility:
NOPF 3 - Failure to place a notice in the operating record within 30 days of closure identifying the location of the unit within the facility. [40 CFR 262.17(a)(8)(i)(a)].
I observed no additional issues or findings during this inspection. However, further EPA review may add or remove findings.
Janosh
Digitally signed by Janosh Wolters
W___o__lt_e__r_s_______1_0:_22_:5_1_-_04_'0_0_' _____ Date: 2022.08.19
Janosh Wolters
Energy Engineer
Date: August 19, 2022
CANDACE
Digitally signed by CANDACE BEDNAR
Date: 2022.08.19 15:11:08 -05'00'
_B_E__D_N__A__R_____________________
Amber Whisnant
Section Chief
ECAD/CB/RCRA, EPA Region 7
Date: _________________
Attachments: 1. Facility Layout (1 page) 2. Pella Corporation - Pella Operations Photolog (1 page) 3. Pella Corporation - Pella Operations Photos (9 photos/10 pages) 4. EPA Inspection Checklist (36 pages) 5. Confidentiality Notice (1 page) 6. Receipt for Documents and Samples (1 page) 7. Notice of Preliminary Findings (1 page) 8. Hazardous Waste Site Info Verification Report for Inspector (1 pages) 9. Rust Remover Waste Profile (5 pages) 10. Still Bottoms Waste Profile (5 pages) 11. Flushing Solvent SDS (9 pages)
22
12. Mill Sludge Waste Profile (5 pages) 13. Wood Preserver Waste Profile Real (5 pages) 14. Waste Lacquer Waste Profile (5 pages) 15. Liquid Waste Paint Waste Profile (5 pages) 16. Solid Waste Paint Waste Profile (5 pages) 17. Paint Related Material Waste Profile (5 pages) 18. EDM Filters (5 pages) 19. Immersion Cleaner Waste Profile (5 pages) 20. Immersion Cleaner SDS (15 pages) 21. Burn Ash Waste Profile (5 pages) 22. Ink Waste Profile (7 pages) 23. Ink SDS (18 pages) 24. Laundered Rags Receipt (1 page) 25. Scrap Metal Vendor Information (1 page) 26. SWA for WWTP Sludge (1 page) 27. WWTP Sludge TCLP Analytical (7 pages) 28. CAA Inspection Log (1 page) 29. Solvent Based Paint SDS (17 pages) 30. Water Based Paint SDS (10 pages) 31. Immersion Cleaner Manifest (2 pages) 32. SOP Solvent Contaminated Wipes (1 page) 33. Pretreat SDS (7 pages) 34. Aluminum Adhesion SDS (6 pages) 35. Prewash Aluminum Coating (7 pages) 36. Used Oil Invoice (2 pages) 37. Contingency Plan (57 pages) 38. Quick Reference Guide (11 pages) 39. RCRA Training Record Quizzes (5 pages) 40. LabPak Manifest (4 pages)
23
Attachment 7, Page 1 of 1