Document rxgRp53yeOYMKyeyavJN1am4v

l C. H *T, C . ^ i , CO ~T~l*4 `jL/^V "c`> e.** $l p <*.a*t^* PCB'x: How Toxic? Polychlorinated biphenyls (PCB's) are recognized at ubiquitous environmental contaminants. In 197). this worldwide problem resulted in a decision by the Organization for Economic Cooperation and Development to control the use and disposal of PCB's (/). At present, both the U.S. and Canadian governments are preparing legislation for the control of toxic substance!. ' The concern over PCB's is based on two factors, namely their environmental SCIENCE. VOL. 1*2 persistence and iheir toxicity. Recent re sults. how ever, cast doubts on the latter. Bowes er at. D) observed concentrations of highly toxic polychlorinated dibenzofurans (PCDF's) ranging from 0.1 to O.S microgram per gram in all hut one of the North American PCB's (Aroclort Earlier studies by Vos or at. (J) h:id indicated that only PCB's manufactured in Japan (Kanechlor) and Europe (Clophen, Phenochlor) contained such impu rities. In addition. PCDF's and other by products were recently found In "pure" PCB isomers W). The toxicity of PCDF's exceeds that of PCB's by approximately four to six orders of magnitude. Their presence in PCB's has. therefore, significant bearing on toxicity studies on PCB's. com mercial mixtures, and isomer prepara tions alike. Yet. in only a small propor tion of the scientific reports on this sub ject is the problem of PCDF impurities in PCB's discussed. Obviously, the degree of this contamination is variable with the origin and prubably also w ith other de tails of the manufacturing processes. I strongly recommend, therefore, that in all future toxicity studies and for as many past studies as can be docu mented. precise information on the PCB's used (source, date or manufac ture, lot number, and so forth) be record ed. I further recommend that past experi ments for which such information is available be reevaluated in view of the strong possibility of the presence of PCDF's and their overriding toxic ef fects. Klaus L. E. Kaiser Environment Canada. Canada Centre for Inland Waters. Burlington. Ontario L7R 4A6 lilmm I. Ol|XnlZi:iun tor Ecwv-r.itr C.v.rff^l.wi *nJ CV vetarntt"4 rrr-'* tglraf lOl.fti fcn. U I cfr'rvnry iVJi.fr -! 2- G W Bc>ci M J MuiviUl. M. ft. LfcCjnp A. S. Kcnde. J. Af*c Chtm. 1). 1222 l!W>. J. J. C. Vm, h L- V*i ilef fcun. M C Ttn Kitevef Dr Bfiw. ft h D* Vt>. fi**/ Cs'-tmrf. ri'.urfrf. I. 6j> I G Vi)|, />ivt)fi, Hfrith Pr*\pr\:i. i1>? 11972* 4. U. Mkmi, O. (' A Art* Chrm IT J|?| D. C. {Ltukti*n\ i-M, IM 119-2l HONS 213560