Document rxYZGQmw0RnNR70gr7ododX3r

MEDICAL DEPARTMENT BULLETIN Data Sheet EC-202 NEW PRODUCTS Final Environmental Compatibility Assessment As provided for in corporate procedures (D-II-8 in Manage ment Guide and Medical Department Bulletin EC-201) the division in the company responsible for a new product must obtain a final environmental evaluation before commercial ization. To obtain this evaluation, the individual responsible for the product reviews the Preliminary Environmental Compati bility Assessment (EC-201) form, consults the literature, obtains the best answers he can by consultation with others, and completes Data Sheet EC-202. He sends this to the Medical Director along with a statement of his principal sources of information, the intended product uses and a request for a final environmental evaluation with intent to commercialize. The Medical Director will respond as to the environmental acceptability, restrictions, or additional information needed, if any, or if unacceptable, the reasons why. DSW 588149 STLCOPCB4093485 2- - - (Cont. EC-202) Environmental Compatibility Assessment Scheme Instructions; Answer each question in turn, "yes" or "no". Each answer is provided with a directive concerning the question to be answered next; the logic of the scheme assumes that Ques tions skipped would be answered "no" and can thus be ignored. The last Question, No. 12, should be considered if it is decided to make and sell materials which are very useful but potentially dangerous to man or his environment. When applying this form, consideration must be given to the product Monsanto supplies, product impurities, as well as thefinal or end product that enters the environment. ITEMS 1 THROUGH 3 ARE TO ESTABLISH THE HAZARDS TO HUMANS OF PRODUCTS, PRODUCT IMPURITIES, BY-PRODUCTS OR MANUFACTURING AND DEGRADATION PRODUCTS. If Go to: 1. Is the material so physiologically inert that there need be no con cern about health hazards to Yes humans? No 4 2&3 2. a) Is the material toxic to per sons as a result of a single contact with high concentra tions? b) Is the material toxic to per sons at lesser concentrations following repeated or prolonged exposure? c) Is the material likely to be carcinogenic, teratogenic or mutagenic? 3. Recognizing the hazards to people, can procedures be devised for ' Yes 4 safe handling at reasonable cost? No -Do Not Sell ITEMS 4 THROUGH 6 ARE TO ESTABLISH IF CONSIDERATION HAS . BEEN GIVEN TO DISPOSAL, DEGRADATION PRODUCTS OF DISPOSAL AND ENVIRONMENTAL DEGRADABILITY. If Go to: 4. Can "closed-loop" disposal pro visions be developed for the product so it will never reach the environment? Yes NO 5 6 DSW 588150 STLCOPCB4093486 -3- (Cont. EC-202) If Go to: 5. Is it likely the degradation products from the "closed-loop" disposal system could be harm ful to humans? Yes -Recycle Degra dation Products to 2. Continue at 6. No 7 6. Is it likely that the product will degrade in the environment or in anv of the currently used disposal systems? Yes -Recycle Degra dation Products to 1. Continue at 7. No 7 ITEMS 7 THROUGH 10 ARE TO ESTABLISH HAZARDS OF PRODUCTS AND DEGRADATION PRODUCTS TO PLANTS, ANIMALS OR ECOSYSTEMS. 7. Is it probable that the product or degradation products are harmful to plants and animals at concentrations to which they are likely to be exposed? Yes No 8 9 8. Recocrnizinq the hazards to plants and animals, can proce dures be devised at reasonable costs to render the material innocuous? ^ Yes 9 No -Do Not Sell 9. Is it likelv that harmful secondary reaction products could be formed from the harmless parent material as Yes -Recvcle the a result of a chemical, bio By-product at 1 & chemical, or biological activity 7. Continue at 10. in the environment? No 10 10. Is there reason to suppose that the material could have dele terious effect on the ecosystem, e.g., through concentration in the food chain, antagonism, synergism, abiotic reactions, chelation or plain physical con centration even though the Yes -Recycle to 8. material was not directlv toxic Continue at 11. to the biota? No 11 11. Have procedures been devized to handle catastrophes in the production, storage, or trans portation of the product? Yes -Sell 12. Is it necessary to restrict sales to specific end uses? Dsvv588isi STLCOPCB4093487