Document rxYZGQmw0RnNR70gr7ododX3r
MEDICAL DEPARTMENT
BULLETIN
Data Sheet EC-202
NEW PRODUCTS
Final Environmental Compatibility Assessment
As provided for in corporate procedures (D-II-8 in Manage ment Guide and Medical Department Bulletin EC-201) the division in the company responsible for a new product must obtain a final environmental evaluation before commercial ization. To obtain this evaluation, the individual responsible for the product reviews the Preliminary Environmental Compati bility Assessment (EC-201) form, consults the literature, obtains the best answers he can by consultation with others, and completes Data Sheet EC-202. He sends this to the Medical Director along with a statement of his principal sources of information, the intended product uses and a request for a final environmental evaluation with intent to commercialize. The Medical Director will respond as to the environmental acceptability, restrictions, or additional information needed, if any, or if unacceptable, the reasons why.
DSW 588149
STLCOPCB4093485
2- -
-
(Cont. EC-202)
Environmental Compatibility Assessment Scheme
Instructions;
Answer each question in turn, "yes" or "no". Each answer is provided with a directive concerning the question to be answered next; the logic of the scheme assumes that Ques tions skipped would be answered "no" and can thus be ignored. The last Question, No. 12, should be considered if it is decided to make and sell materials which are very useful but potentially dangerous to man or his environment. When applying this form, consideration must be given to the product Monsanto supplies, product impurities, as well as thefinal or end product that enters the environment.
ITEMS 1 THROUGH 3 ARE TO ESTABLISH THE HAZARDS TO HUMANS OF PRODUCTS, PRODUCT IMPURITIES, BY-PRODUCTS OR MANUFACTURING
AND DEGRADATION PRODUCTS.
If Go to:
1. Is the material so physiologically
inert that there need be no con
cern about health hazards to
Yes
humans?
No
4 2&3
2. a) Is the material toxic to per sons as a result of a single contact with high concentra tions?
b) Is the material toxic to per sons at lesser concentrations following repeated or prolonged exposure?
c) Is the material likely to be carcinogenic, teratogenic or
mutagenic?
3. Recognizing the hazards to people,
can procedures be devised for '
Yes
4
safe handling at reasonable cost? No -Do Not Sell
ITEMS 4 THROUGH 6 ARE TO ESTABLISH IF CONSIDERATION HAS . BEEN GIVEN TO DISPOSAL, DEGRADATION PRODUCTS OF DISPOSAL AND ENVIRONMENTAL DEGRADABILITY.
If Go to:
4. Can "closed-loop" disposal pro visions be developed for the product so it will never reach
the environment?
Yes NO
5 6
DSW 588150
STLCOPCB4093486
-3- (Cont. EC-202)
If Go to:
5. Is it likely the degradation products from the "closed-loop" disposal system could be harm ful to humans?
Yes -Recycle Degra dation Products to 2. Continue at 6. No 7
6. Is it likely that the product will degrade in the environment or in anv of the currently used disposal systems?
Yes -Recycle Degra dation Products to 1. Continue at 7. No 7
ITEMS 7 THROUGH 10 ARE TO ESTABLISH HAZARDS OF PRODUCTS AND DEGRADATION PRODUCTS TO PLANTS, ANIMALS OR ECOSYSTEMS.
7. Is it probable that the product or degradation products are harmful to plants and animals at concentrations to which they are likely to be exposed?
Yes No
8 9
8. Recocrnizinq the hazards to
plants and animals, can proce
dures be devised at reasonable
costs to render the material
innocuous?
^
Yes
9
No -Do Not Sell
9. Is it likelv that harmful
secondary reaction products
could be formed from the
harmless parent material as
Yes -Recvcle the
a result of a chemical, bio
By-product at 1 &
chemical, or biological activity 7. Continue at 10.
in the environment?
No 10
10. Is there reason to suppose that
the material could have dele
terious effect on the ecosystem,
e.g., through concentration in
the food chain, antagonism,
synergism, abiotic reactions,
chelation or plain physical con
centration even though the
Yes -Recycle to 8.
material was not directlv toxic Continue at 11.
to the biota?
No 11
11. Have procedures been devized to handle catastrophes in the production, storage, or trans portation of the product?
Yes -Sell
12. Is it necessary to restrict sales to specific end uses?
Dsvv588isi
STLCOPCB4093487