273 Determination of Methanol in Body Ftutda. F. Stratton. Tech. Boil. Registry Med. Technologists 25, 179-183 (1955); Am. J. Clin. Pathol. 25, 1071-1075 (195TJ.
A preliminary Isolation by steam distillation Is followed by permanganate oxidation.
A color reaction (a then carried out with reduced fuchsia tor a qualitative test, or chromo
tropic acid (or a quantitative determination. Ethanol does not interfere with the methanol
determination.
-- Chem. Abate.
274 Determination of Trichloroethylene in Air by the Rayleigh Interferometer. R. E. Jaho. Analyst 80, 700-704 (1955).
The Rayleigh interferometer was used to detexmine the refractive index of samples
of air containing 0 to 3% trichloroethylene vapor. The readings are not linearly related to
the difference of refractivity between the two gases which are compared, but a simple calcu
lation gives a value which is related. The interferometer is a very convenient instrument
when a large number of determinations are to be made, but the high accuracy of the instru
ment is not fully utilized.
- Chem. Absts.
275 A Method for Removing Insecticide Residues of Wettable Powders from Sprayed Surfaces. F. Barlow. Boll World Health Organization 12. 359-364 (1955).
Sample surfaces of glass, unpointed plywood, and mud bricks were sprayed with a
75# DDT wettable powder. Adhesive tape carefully applied, removed, and analyzed tor labile
chlorine gave recoveries considered suitable for field studies for evaluation of residual DDT
on sprayed surfaces.'
-- Chem. Absts.
276 Some Principles of Airborne Dust Sampling. J. G. Dawes, B. A. Maguire, and D. L. Tye. Research Report No. 102, Safety, in Mines Research Establishment, Portobello St., Sheffield, England. 16 pp. (1954). SI. 00.
In dlls report the authors bring together the information they have collected con cerning the behavior of dust clouds in coalmines, in order that dust sampling may be economi cally performed and that the scope and limitations of the data it famishes may be appreciated. At distances greater than ten roadway diameters from the source of dust the airborne concen tration is substantially uniform over the cross-seetion of the roadway, and particles within the respirable range (0. 5-5 microns) do not deposit appreciably over distances np to 100 yards from the source. Short-term fluctuations are less important at a greater distance from the source. Fluctuations in dost concentration are large, and either large numbers of short-period samples or a continuous sample are required to give a reliable mean. The relation between the shift mean and the moan of peaks, the differences of-duxt concentrations between shifts, and the correlation between thermal precipitator and P.R. U. hand pump results are discussed.
-- Bull. Hyg.
277 Sampling and Analysis of Industrial Process Dost. K. Westlin and L. 1. Cserwonka. Am. lad. Hyg. Assn. Quart. 16, 283-292 (Dec. 1955).
A technique is described for collecting a dust sample suitable for both concentra tion determination and analysts. The most suitable filter medium was found to be a type AA flber-glass.of given size, denslty.and pad thickness, heated to about 600*F to remove bond ing material. The apparatus is described and illustrated. A null-balance type of sampling tube maintained sufficiently constant air velocity, which is essential. Sieving followed by elutriadonwas used in the size separations. Procedure tor washing filter pads, sieve pro cedure, dust dispersion, and pipette procedure are described. Other methods (or special purposes including dusts not suitable for wot recovery, and particles of very small size, are described and evaluated. A typical dust sampling and analysis problem is described. For most practical purposes the results obtained are apparently accurate. In some portions of the procedures, particularly in the size analysis, the methods become an art and not merely a mechanical procedure, ^Zfdfthe hill *nd patience of the analyst play a large part in the final accuracy of the results.