Document rxDb7k6QB0gJBQVnDdqo2aEQJ

bcc (Re*. Mxr.) gP/SEff/OPP/Plle Dear Up. .: 1.1 Confirming our telephone conversation on concerning conversion of your Thermlnol" PR heat transrer system, I have enolosed literature on two possible replacement fluldB, Monsanto's Therminol 55 and 66. Thermlnol 66 has the higher maximum opera ting temperature (650F vs. 575*F). It Is, of course, your decision what produot or system you choose as a replacement for Thermlnol FR. SU00B3TBD CONVERSION STEPS 2.1 Based on our telephone conversation It appears that conversion of your system will require: (Refer to Conversion Bulletin for system requirements at heater and for cleanout) 2.2 We want to point out that unlike the Thermlnol PR products, Ther mlnol 55 and 66 are not classified as fire resistant heat trans fer fluids. Consequently, you should consider the use of protec tive devices to minimize any added fire risks. We suggest you oonsult with the Insurer of your property relative to this matter. 2.3 In order to protect Thermlnol (55-66) from oxidation, we suggest , the use of an Inert gas blanket on your expansion tank system to preclude air contact with hot fluid. The Inert blanket Is re quired only at tank temperatures above 120P. If you use a re circulating line to the expansion tank, this Bhould be valved closed during the normal system operation. 2.4 A snuffing device should be Installed on the combustion chamber of your (gas/oll) fired heater. Steam, oarbon dioxide or nitro gen may be used to extinguish a furnace fire caused by a heater tube rupture. The snuffing device may be activated by a high temperature switch In your furnace stack. 2.5 While both Thermlnol 55 and 66 are miscible with Thermlnol PR, we reoossnnd against adding either fluid to "top-up" an PR system except as an emergency measure for a brief period of time. Addition of Thermlnol 55 or 66 can cause the mixture to lose its fire resistant properties. Also, the useful life of Thermlnol 55 or 66 may be drastloally reduced by reaction with trace quanti ties of Thermlnol FR decomposition products. MQNS 095258 -2- 3Y3THM CUKM-OPT 3.1 When converting your system to Thermlnol ___, we suggest you tho roughly drain the Thermlnol PR. Plush the piping, equipment and expansion tank with Thermlnol 55 or a non-chlorlnated solvent and again drain Into leak-free drums. Zf Thermlnol 55 Is selec ted as the flush fluid. It Is advantageous to operate the system several days before draining to loosen and remove pipe scale. CRUM RgrPIW & DISPOSAL 3.25 We request you use return drums that meet DOT 17E Specification (55 gallon drums. 18 gauge minimum. 2 bung head; 5 gallon drums. 24 gauge minimum) to prevent leakage. The outside of the return drums should be free of fluid material and free of leaks. Cleanup or other costs affecting the carrier related to fluid leaking from drums will be charged to the shipper. 3.3 For return of drained Thermlnol PR fluid, (number) pre-addressed labels marked "disposal only" will be sent to you from W. Maddox In St. Louis. You will need to clearly Indicate the drum con tents on each label. 3.A5 When you have fluids for return, please contact W. Maddox (800) 325-3050 as to the fluid type, number of drums and any special Invoicing procedure you may require. Mr. Maddox will send you the necessary pre-addressed drum return labels which we request be used. 3.5 Confirming our telephone conversation of , concern ing the inolneratlon of (fluid type) fluids, we offer a 3^/pound Incineration service for Monsanto rca* fluids delivered to our Sauget, Illinois plant (Department 246). The series is Included In this group. We will charge 5^/pound to incinerate non-Monsanto fluids containing PCB If sent freight prepaid to our Sauget plant. Fluids containing in excess of Z% water are not aooeptable. We cannot handle solids (i.e. sawdust, rags, or sludge). We sug gest that you oheok local authorities and your own environmental department for a land fill approved for disposal of (fluid type). Our Sauget plant Is Instructed to refuse receipt of containers containing solids, and to return same to the sender at the sender's expense. MONS 095259 -35.0 A Thermlnol FR Conversion Bulletin iB attached to assist your conversion planning, 5.1 Wo suggest you plan your conversion as soon as possible. The Thermlnol PR fluids are no longer available and are not compa tible with other heat transfer fluids. 5.2 Thank you for your cooperation. Please feel free to contact me if you have any additional questions. Sincerely, Enclosures co: HONS 095260