Document rxDEx34LoybjmoeYMXQv9Gm3q
Ventilators
W. F. Hirschman Co., Inc.
Le Roy, New York
Manufacturers of
EFFICO
Rotary Ball Bearing (Oil Flooded) Roof Ventilators
Product--Effico Fan Equipped Rotart Ball Bearing (Oil Flooded) Roof Ventilators (Patented).
Construction and Principle of Operation--Hie Effico rotating cowl exterior is covered by wind propelled blades; the interior by suction blades. There are no moving parts. The Effico shaft rotates on ball bearings, fitted with clock precision in solidly enclosed dust-tight and oil-tight housings, and is fiooded in inches of non-freesing oil (furnished by us); no oiling required for years (proven),
and the Effico is absolutely noiseless.
Great Air Volume Exhaust at Low Wind--All Efpicos will draw con
siderable air at a 1-tnile breeze (an apparent calm) without stack or heat assistance.
The 30-in. size will rotate (standing start) at 0.7-oz. pressure, Yi mile breeze. Cowl outlet is ova 50 per cent larger than its stack area which is ample, as no wind enters ventilator to gain the so-called siphonage effect. Suction fan is same size as
rotating cowl (note dimension chart). Thus each Effico is equipped with fan over 50 per cent greater in diameter than its stack area. Fan pulls air up stack at even the slowest turning movement and wind blowing across the outlet adds to its
efficiency.
-
Symmetry--The Effico has artistic lines and pleasing appearance. Lowest in
height of rotary ventilators by over 50 per cent average. Note dimension chart.
Weatherproofness--The Effico rotary ball-bearing ventilator operates during all kinds of weather--rain, ice. snow or sleet does not affect or hamper its exhausting. 'No drip pans or bird screens are needed.
Effico Rotary Ball-Bearing Ventilator Installation
Effico Standardized Ventilators
Gage of
Dimensions. In. A BC D
Galvanized Net Cop-
Steel
Weight per Code
E Cowl Base
02.
6 10
44>'A/?
51/2 11
13 16
201/?
26 26
26 26
10 18
14 Sheck 14 bachem
12 5 14 21% ?1
24 24
25 14 Scene
18 7 15/2 27 23 24 10 25 42 30
24 24
24 24
38 95
16 Saturn 18 Shake
Gage of
Dimensions, In.
Galvanized ` Net Cop
Steel
Weight per
A B C D E Cowl Base Lb. Oz.
30 12 27 36 12 31 42 19 37 48 19 40 54 19 44 60 19 48 66 ?5 53 72 30 57 84 30 58 % 30 63
52 32 62 - 32
68 43 76 43
86 43
98 43 I03V? 49
114 54 130 54
153 60
22
22 22
22 22
20
20 20 18
18
20 20 18 180 24 18 300 24 18 370 24 18 525 24 18 650
18 700 18 750 16 900 16 1025
Code
Sank Sergeant Serpent Serve Sham Shawl Sunk Shop Slave Shekel
Detail of Effico Rotary Ball-Bearing Ventilator
Capacities of Effico Rotary Ball Bearing Ventilators Cubic Feet of Air Exhausted Per Minute
Wind Ve Temperature difference in degrees Fahrenheit in building and outside
locity
mi. per 0 | 10 | 2D | 30 0 | 10 | 20 ] 30 0 | 10 | 20 | 30 hour
12-in. Ventilator
18-in. Ventilator
24-in. Ventilator
5 2951 3651 430 465 500 740 650 925 900 1325 1500 1590
10 14
342 432 500 520 755 970 1070 1135 1325 1725 1900 2025 40Cn 500| 530 580 990 1080 1160 1270 1600 2000 2200 2300
30-in. Ventilator
36-in. Ventilator
42-in. Ventilator
5 14001 20801 2386 2600 2075 3000 3375 3650 2770 4090 45501 4950
10 14
2100 2925 3050 3250 2960 3880 4275 4550 3975 5175 5700 6000 2560| 3200| 3175 3525 3645 4365 4750 4935 4900 6000 66001 6900
48-in. Ventilator
54-in. Ventilator
6U-in. Ventilator .
5 10
36501 5300 6000 6500 4580 6600 76001 8200 5700 8300 9400 10200 5300 7100 7600 8100 6625 8625 960010000 8280 10900 12000 12700
14 6445 8050 8900 9200 8000 I000( 11000*11600 10000 12600 13800 14500
72-in. Ventilator
84-in. Ventilator
5 8200 11800 13000 14800 11000 16300 16500 20000
"Effico"
10 11900 15500 17000 18300 16300 21600 23600 25000 The Highest De
14 14400 18000 19800 20800 19600 25000 27000 28500 veloped Ventilator .
Above capacities are guaranteed and conservative. They are based on official test made at Carnegie Institute of Technology, Pittsburgh, Pa., and a great many by ourselves on special and regular installations.
506
Ventilators
The Iona Ventilator Company, Inc.
2821 W. Dauphin St.
PHILADELPHIA, PA.
Designers and Manufacturers of Ventilators for 20 years
"XIT" and "IONA" Ventilators Adapted to Factories, Schools, Theatres, Hospitals. Public and Farm Buildings.
"XIT" VENTILATORS
Vent
Size In.
Out
side Dia. In.
Gauge Height Iron
In. or
Meta]
Approx.
Finished Weights
Lbs.
Gauge Cop
per Oz.
List Prices
Four basic principles are incorporated in the de sign and construction ol "XIT" Ventilators:
1. Largest area of vertical exits from head. 2. Greatest total exit area from head. 3. No external air can enter ventilator head. 4. Principle of action or
6 IOV4 8V,
7 IW7 10'/,
8 141/4 11
9 I6>/, 12
10 16
13'/,
12 2l'/z liV,
14 25
16#
15 26'/, 17
16 28V4 18'/,
18 30
191/2
20 34 22'/,
22 39/, 24
24 43 26
26 46 28
28 50 i30
30 54 32
32 57 34
34 60 36
36 40
64
71V.
31% 42
42 77 45
44 79 48
48 86 51
54 97 57
60 107 63
66 118 69
72 129 75
26 26
26 26 24
24 24 24
22 22 22
22 22
22 22 22
22 22 22 20
20 20
20 18 18 16
18
5 6
8 10
12 16 28 31
34 43
50 55 61
84 105
131 146 160 178
238 275
305 350 615 757
880 980
16 $ 12.00
16 14.00
16 16.00 16 18.00 16 20.00
16 24.00
16 28.00 18 30.00
18 32.00
18 36.00
18 40.00 18 44.00
18 48.00
20 52.00 20 56.00 20 65.00
20 80.00
20 100.00
20 120.00 20 180.00
20 190;00
20 200.00 20 240.00 24 300.00 24 360.00 24 420.00 24 480.00
suction is like that of chimney or stack, which is
EXHAUST DATA CARD OF "XIT" VENTILATORS
doubled by a second or
internal band, making two points of suction, always to
the lee side of head thereby greatly increasing action
Terns. Wind
Inside Velocity and Mi. per Outside Hour
12
Cubic Feet of Air Through Ventilator per Hour
14 16
18 20
21 | 30
36 . 40 | 48
through ventilator. Guaranteed exhaust and
storm proof.
Liberal discounts. Damper and base prices
70 70 70 70"
70"
3 5
10 15
20
20.546 27,783 24.460 33.075 54.244 46,305 47.941 64,827 67.117 90.757
36,352 45,960 43.27q 54,714 60.53d 79.599 84.750 III,438
U8.650l156.013
50.604 60.480 84,672 118.540 165.9561
81.8111127.008 193.287 97.036] 151.200 218.198 125.850211,680 305.477
176,190296,352 427.667 246.666(414.892 598.733
225792 268.800 376.320
526,840
737,587n
326.044 388.147 543.405
760.767
,065.073
on request.
Increase in velocity of wind over five miles, increases exhaust 8 per cent per mile.
Higher inside temperature increases exhaust 1 7-10 per cent per degree.
In elevation over 25 feet, exhaust increase varies as square root of height.
IONA" VENTILATORS
507